agilebox solusi data center untuk pemerintah
TRANSCRIPT
ZTE ICT Solution
"Jadikan Ruang Server Menjadi Data Center"
By PT. GOMEDS NETWORK
KONDISI SAAT INI
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
D a t a A d a l a h S e b u a h A s e t
Agilebox All-in-One Cabinet
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
T e k n o l o g i T e r b a r u M i k r o D a t a C e n t e r
Agilebox Cooling System
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
S i s t e m p e n d i n g a n y a n g t e r i n t e g r a s i d a l a m C a b i n e t
Agilebox Fire Extinguishing System
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
Sistem pemadam kebakaran yang terintegrasi dalam Cabinet
Agilebox Specifications
Cabinet unit
42U standard cabinet (1 Unit) 600 mm x 1200 mm x 2000 mm
Door contact (4 Unit) When the temperature in the cabinet is too high, the front door and rear door can open automatically. Each door has two door contacts.
Internal sensors (1 Set)
1. Temperature and humidity sensor
2. Smoke sensor
3. Access control: dry contact output and door opening alarm
PDU (1 Unit) Dedicated PDU vertically installed at the back of the cabinet
Cooling unit 5 KW (1 Unit) Split-type air conditioning system (indoor unit and outdoor unit), electrical heating compensation device, DC frequency-conversion compressor, and N+1 redundancy fans.
Control unit: Security management module (1 Packet)
1. Monitoring air conditioner operation data
2. Monitoring the UPS, dry contact output
3. Monitoring external temperature and humidity sensor
4. Monitoring the smoke sensor
5. Monitoring the access control, dry contact output, and door opening alarm
6. Monitoring the buzzer, dry contact output
7. Monitoring the data reporting display screen
8. Monitoring the upper computer
9. 7” screen
Power distribution module (1 Set) The power distribution module is installed inside the air conditioner, providing a main power supply for the server cabinet and air conditioner. The SPD is optional. The UPS bypass switch (UPS switch and bypass switch are interlocked) is available by default.
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
Agilebox Specifications
Optional Peripheral Module
UPS 6 KVA (1 Unit) Rack-mounted UPS
Storage battery (16 Pcs) 12 V-100 AH
Enhanced audible and visual alarm (1 Set) Enhanced audible and visual alarm signaling device
Water leak detection (1 Set) Strap water leak detection rope
Camera + NVR (1 Set) Two cameras + 1 NVR with the interface interconnecting with the video monitoring platform of the equipment room
Cabinet-scale fire fighting system (1 Set) Cabinet-scale fire fighting system (FM-200)
Access control (1 Unit) Finger print and card identification access control system
Control unit : Security management module (1 Packet)
1. Monitoring air conditioner operation data
2. Monitoring the UPS, dry contact output
3. Monitoring external temperature and humidity sensor
4. Monitoring the smoke sensor
5. Monitoring the access control
6. Monitoring the buzzer.
7. Monitoring the data reporting display screen
8. Monitoring the upper computer
9. 7” screen
10. Monitoring the storage battery (battery tester is needed)
11. Monitoring the power
12. Monitoring fire protection
Battery testing module (1 Unit) Collecting 12-V battery voltage, resistance, and temperature
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
Agilebox Specifications
Optional IT devices
Rack-mount server (2 U)
Low-cost server
Two R4300 G2 E5-2620 V2 processors (6-core, 2.10 GHz including the cooling fin), four 16G DDR3-1600 memory chips, four R4300 G2 600GB SAS 2.5" hard drives 10krpm, and one dual-port gigabit network card (electrical port)
Ethernet switch (1U)
48 10/100/1000Base-T Ethernet ports, two gigabit Combo ports (10/100/1000Base-T Ethernet port or 1000Base-X SFP port)
Two fixed 1000Base-X SFP ports
Server Aplikasi SIMDA Optional
Server Aplikasi eMonep/eRenger Optional
Server Aplikasi LPSE Optional
Server Aplikasi SIMPEG Optional
Server Aplikasi eHealt Optional
Server CCTV Optional
Server VoIP Optional
Server Video Conference Optional
Server – Server eGovernment Lainnya Optional
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
Agilebox eGovernment Concept
VPN LAN
E1/SIP Trunk
eFax
Call Center Video Phone Cloud
Desktop UC&C Client
T700
KAB/KOTA DATA CENTER
IPPhone
VPN LAN
E1/SIP Trunk INTERNET
eFax
Call Center Video Phone Cloud
Desktop UC&C Client
T700
PROVINSI DATA CENTER
IPPhone
INTERNET
INDONESIA DATA CENTER
ISP
INTRANET
Untuk Informasi & Penawaran Harga eMail [email protected]
Phone 085342737722, 081241116789
ZTE UC&C Product Achievements
Vietnam, Railway
Co.
Philippines , ATI LAOS, LTC, ETL
Singapore, J NISSI
Kazakhstan, ASTEL Mongolia,
BOLDSOFT
Somalia, Somalia
Telecom
Franch, Intelware
UK , Touchline video
Spain, GTI, DIODE
Portugal, GTI-PT, Ditrs-IT
Venezuela, CADAFE, MOH
Uruguay, Ministry of the
Interior Argentina, SeteTec
Zambia, ZESCO
Ethiopia, MOCB,
MOE, ICT Congo, CCT
Angola , P&T
Institute
Botswana, MOT
Egypt, GAEB
Papua
New
Guinea, MOE
Sudan, DATANET
Nigeria, NSS
Equatorial Guinea, MOT
America, KY Technologies, Redfort Networks, China Telecom United
Stated Branch , etc.
Columbia, EMCALI
Mexico, 4IP, GDC, SEESA
Brazil, BlackIT, NVT
Mozambique, MOE
Libya, GPTC
Saudi Arabia Myanmar,
Asia World , JCCS
Services 50+ countries and regions, with over 150,000 video conferencing terminals shipped worldwide
Norway, Avkom, Easymeeting Russia, China Bank Branch Softtronic
Australia , NextGen
Indonesia, SMI
© ZTE Corporation. All rights reserved
10
Terima Kasih
wwwen.zte.com.cn