iba Solutions For Life Sciences www.iba-lifesciences.com MAGSTREP TYPE3” XT BEADS – magnetic Strep-tag purification at its best! Product information Strep-tag Magnetic beads for high demands ! high specificity – low background – even for elution by boiling high binding capacity high affinity for Strep-tag

Upload: dinhdat

Post on 13-Jun-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ag trep type3” Xt beadS - bertin-bioreagent.com€œtype3” XT Beads 2 ml 2-1040-050 Buffer BX; Biotin Elution Buffer (5x) e information: ep-tag.com. Mag. Strep “type3” XT Beads

iba Solutions For Life Sciences

www.iba-lifesciences.com

MagStrep “type3” Xt beadS– magnetic Strep-tag purification at its best!

Product information

Strep-tagMagnetic beadsfor high demands !

high specificity – low background

– even for elution by boiling

high binding capacity

high affinity for Strep-tag

vsouverain
Texte tapé à la machine
Tel: +33 (0)139 306 036 [email protected] bertinpharma.com
vsouverain
Texte tapé à la machine
Distributed by:
Page 2: ag trep type3” Xt beadS - bertin-bioreagent.com€œtype3” XT Beads 2 ml 2-1040-050 Buffer BX; Biotin Elution Buffer (5x) e information: ep-tag.com. Mag. Strep “type3” XT Beads

GFP

-Strep-

tag

www.iba-lifesciences.com

IBA GmbH Rudolf-Wissell-Str. 28 · 37079 Goettingen · Germany · Phone +49 551 50672-0 · Fax +49 551 50672-181 · [email protected] IBA US Distribution Center 1328 Ashby Road · Olivette · MO 63132 · USA · Phone 1-877-IBA-GmbH (1-877-422-4624) · Fax 1-888-531-6813 · [email protected]

Vers

ion

PI83

-01-

0001

Product information

Cat. No.

2-4090-002 MagStrep “type3” XT Beads 2 ml2-1040-050 Buffer BX; Biotin Elution Buffer (5x)

More information:www.strep-tag.com

MagStrep “type3” XT Beads are Strep-Tactin XT coated ferri-magnetic spheres with the following characteristics:

high binding capacity (1 – 3 nmol/μl beads, corresponding to 30 – 90 μg of a 30 kDa protein) very low non-specific protein binding due to improved coating

flexible elution conditions, under denaturing conditions by boiling in SDS gel loading buffer or under native conditions with biotin

high affinity for Strep-tag – due to new Strep-Tactin XT

These characteristics lead to very good purification results (see Fig.1) and make the MagStrep “type3” XT beads a superior tool for small scale purifications with high demands on protein purity.

GFP

-Strep-

tag

Crude bacterial extract before purification

Fig 1: Purification of GFP-Strep-tag fusion protein from crude bact. extract using MagStrep “type3” XT beads (Protein purification analysis was performed with an Agilent Bioanalyzer 2100 system instead of SDS-PAGE)

Native purification using buffer BX for elution

GFP

-Strep-

tag

Strep-

Tact

in X

T

Denaturing purification using sample buffer and boiling for elution

Purity >95%

Purity >95%

Due to specific binding properties of the beads even the elution by boiling leads to highly pure proteins (GFP peak at ~28kDa ignoring Strep-Tactin XT peak)