afw teledyne l38010 1 of ic 01 brown … afw teledyne 01 brown engineering, inc. a teledyne...

26
/3 AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of IC James J. Vouglitois Exelon Nuclear (Oyster Creek) P.O. Box 388 US Route 9 Forked River, NJ 08731 Report of Analysis/Certificate of Conformance 03/24/2009 LIMS #: Project ID# Received: Delivery Date P.Oa# Release # 3DG#: L38010 EX001-3ESPOC-06 03/16/2009 04/06/2009 01000298 REL.#00010 This is to certify that Teledyne Brown Engineering - Environmental Services located at 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested and documented samples, as received by the laboratory, as specified in the applicable purchase order. This also certifies that requirements of applicable codes, standards and specifications have been fully met and that any quality assurance documentation which verified conformance to the purchase order is on file and may be examined upon request. I hereby certify that the above statements are true and correct. Keith Jeter - /- Operations Manager Cross Reference Table Client ID Laboratory ID Station ID (if applicable) OY-W-7 L38010-1 OY-W-7 OY-W-9 L38010-2 OY-W-9 OY-W-I0 L38010-3 OY-W-10 OY-W-12 L38010-4 OY-W-12 OY-W- 13 L38010-5 OY-W-13 OY-W-14 L38010-6 { OY-W-14 OY-W-15 L3810-7 IOY-W-15 OY-W-I 6 " L38010-8 I OY-W-16 Page 1 of 6 • ,/

Upload: vonhu

Post on 14-Jul-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

/3

AfW TELEDYNE01 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38010 1 of IC

James J. VouglitoisExelon Nuclear (Oyster Creek)P.O. Box 388US Route 9Forked River, NJ 08731

Report of Analysis/Certificate of Conformance

03/24/2009

LIMS #:

Project ID#

Received:

Delivery Date

P.Oa#Release #

3DG#:

L38010

EX001-3ESPOC-06

03/16/2009

04/06/2009

01000298 REL.#00010

This is to certify that Teledyne Brown Engineering - Environmental Services locatedat 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested anddocumented samples, as received by the laboratory, as specified in the applicable purchase order.

This also certifies that requirements of applicable codes, standards and specificationshave been fully met and that any quality assurance documentation which verifiedconformance to the purchase order is on file and may be examined upon request.

I hereby certify that the above statements are true and correct.

Keith Jeter - /-Operations Manager

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-W-7 L38010-1 OY-W-7OY-W-9 L38010-2 OY-W-9OY-W-I0 L38010-3 OY-W-10OY-W-12 L38010-4 OY-W-12

OY-W- 13 L38010-5 OY-W-13

OY-W-14 L38010-6 { OY-W-14OY-W-15 L3810-7 IOY-W-15OY-W-I 6 " L38010-8 I OY-W-16

Page 1 of 6 • ,/

Page 2: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

,A&V hTELEDYNE0 ~ BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38010 2 of 10

Cross Reference TableClient ID Laboratory ID Station ID (if applicable)

OY-W-20 L38010-9 OY-W-20OY-MW-1A-2A L38010-10 OY-MW/T-1A-2A

OY-W-24 L3801 0-11 OY-W-24OY-W-31 138010-12 OY-W-31OY-CST-9 L38010-13 OY-CST-9

Method Reference Numbers

Matrix Analysis Method Reference

WG j H-3 (DIST) EPA 906.0

This report shall not be reproduced or distributed except in its entirety.

Page 2 of 6

Page 3: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 19:02 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38010Exelon Nuclear (Oyster Creek)

EX001-3ESPOC-06

Sample ID: OY-W-7 Collect Start: 03/11/2009 10:20 Matrix: Ground Water (WG)Station: OY-W-7 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-1

Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3(DIST) . 2011 -3.93E+01 1 1.11E+02 I 1.87E+02 pCi/L 10 1 ml 1 03/23/091 60 1 M I UI I

Sample ID: OY-W-9 Collect Start: 03/10/2009 13:02 Matrix: Ground Water (WG)Station: OY-W-9 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-2

So# Activity Uncertainty Run Aliquot IAliquot 1 Refer-ence ICount [Count ICountRadionuclide SOP# -Conc 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3 (DIST) I 2011 -1.84E+01 [ 1.12E+02 i.86E+02 pCi/L I. 1 10 1 ml 1 [ 03/23/091 60 1M [U - Y1Sample ID: OY-W-10 Collect Start: 03/10/2009 11:58 Matrix: Ground Water (WG)

Station: OY-W-10 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-3

Activity Uncertainty t Ru1 Aliquot Aliquot Reference J Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

H-3(DIST) 1 2011 1 -6.76E+01 I 1.IOE+02 1 1.89E+02 I pCi/ 1 10 1 ml n 1 1 03/23/091 60 1 M I U [_I_ _

Sample ID: OY-W-12 Collect Start: 03/10/2009 14:27 Matrix: Ground Water (WG)Station: OY-W-12 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-4

0 Activity UncertaintT Run Aliquot Aliquot Reference Count Count 1CountRadionuclide SOP# Cone 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

-3 (DIST) 20 -4.05E+01 1 1.08E+02 1.82E+02 I pCi/L 1 10 1 ml 1 03/23/091 60 f M I U I [-

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis coHigh = Activity concentration exceeds customer reporting value unless otherwise notedSpec MDC exceeds customer technical specification oL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 3 of 6

0

Page 4: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 1M:02 -BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38010Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-W-13 Collect Start: 03/10/2009 14:09 Matrix: Ground Water (WG)Station: OY-W-13 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-5

Sop#ucid Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOI Cone 2 Sigma MDC Units IVolume Units Date Date Time IUnits Flog Values

H-3 (DIST) I 2011 7-T4.38E+01 1.05E+02 I 1.77E+02 pCi/L I 10 I ml F 03/23/091 60 I M I U ISample ID: OY-W-14 Collect Start: 03/11/2009 08:43 Matrix: Ground Water (WG)

Station: OY-W-14 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-6

Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # I Volume Units Date I Date I Time Units Flag Values

H-3 (DST)I 2011 -1.38E+01 I1. 12E+02 I 1.86E+02 Ipi/L ____ 1 ml I F 03/23/091 60 IM iI IV]Sample IH: OY-W-15 Collect Start: 03/11/2009 09:41 Matrix: Ground Water (WG)

Station: OY-W- 15 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LAMS Number: L38010-7

Radionuclide SOP# Cone 2 Sigma MDC Units # Volume Units J Date Date Time Units Flag Values

H-3 (DIST) 2011 -7.24E+01 1.06E+02 1.83E+02 I pCi/L 10 i ml I 03/23/091 60 1 M I U I [I[Sample ID: OY-W-16 Collect Start: 03/10/2009 15:35 Matrix:' Ground Water (WG)

Station: OY-W-16 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMSNumber L38010-8

Radonclde ol Atiity Uneraity DCUnts Run Aliquot Aliquot Reference Count Count jcount FlgVueRadionuclide SOP# Cone 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

H-3 (DIST) 11 1 2.20E401 I 1.09E+02 1.78E+02 pCi/L 10 I ml 03/23/091 60

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum WU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma **** Results are reported on an as received basis O

Hh AHigh Activity concentration exceeds-customer reporting value unless otherwise notedSpec MDC exceeds customer technical specification 0L = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text'indicates reportable value. 0 O~~~Page 4 of 6 -v

Page 5: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis Aro TELEDYNE03/24/09 18:02 BROWN ENGINEERING, INC.

A Teledyne Technologies Compeny

L38010Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-W-20 Collect Start: 03/10/2009 14:40 Matrix: Ground Water (WG)Station: OY-W-20 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38010-9

So# Activity jUncertainty fRun Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

t-3 (DIST) T 201i -I -2.34E+00 1 1.15E+02 1.89E+02 pCi/L I 10 ml 1 1 03/24/091 60 F M T'U I ISample lID: OY-MW-1A-2A Collect Start: 03/11/2009 10:30 Matrix: Ground Water (WG)

Station: OY-MW-1A-2A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-10

Activity Uncertainty Run Aliquot Aliquot Reference Count Count ConRadionuclide SOP# Conc 2 Sigma MDC Units # n Volume Units Date Date Time Units Flag Values

H-3 (DIST) I 201i 2.08E+01 1.15E+02 1.871-E02 pCi/L I I 10 I ml I 03/24/091 60 I M { U I ISample ID: OY-W-24- Collect Start: 03/10/2009 10:51 Matrix: Ground Water (WG)

Station: OY-W-24. Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L3 8010-11

Activity Uncertainty [Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP#. Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3 (DIST) T 2011 " 8.19E+01.1 1.17E+02 1.84E'+02 pCi/L 1 I 10 1 ml [ 03/24/091 60 I M [U I [ 1Sample ID: O.Y-W-31 Collect Start: 03/10/2009 15:56 Matrix: Ground Water (WG)

Station: OY-W-31 Collect Stop: Volume: -Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-12

Activity Uncertainty Run Aliquot 1Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

0-3 (DIST) .. 2011 1.82E+01 I 1.13E+02 1 1.84E+02 pCi/L 10 ml 03/24/091 60 1 M U I • I

Flag ValuesU = Compound/Analyte not detected or. less than 3 sigma No = Peak not identified in gamma spectrum+ Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis 00High Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification u ot

L = Low recovery MDC - Minimum Detectable ConcentrationH - High recovery Ua

Bolded text indicates reportable value. Page5 of 6PH

0j

Page 6: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis03/24/09 18:02

L38010Exelon Nuclear (Oyster Creek)

EX001-3ESPOC-06

TELEDYNEP'• BROWN ENGINEERING, INC.

A Teledyne Technologies Company

James J. Vouglitois

Sample ID: OY-CST-9 Collect Start: 03/11/2009 15:33 Matrix: Ground Water (WG)Station: OY-CST-9 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38010-13

SOP# Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Con 2 Sigma MDC Units , Volume Units Date Date Time Units FlagValues

P-3 (DIST) 2011 1.68E+02 1.21E+02 I 1.82E+02 pCi/L 10 ml - 03/24/091 60 1 M FU J

Flag ValuesU =+U*

HighSpec =

L =H

Compound/Analyte not detected or less than 3 sigmaActivity concentration exceeds MDC and 3 sigma; peak identified(gamma only)Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigmaActivity concentration exceeds customer reporting valueMDC exceeds customer technical specificationLow recoveryHigh recovery

No = Peak not identified in gamma spectrumYes = Peak identified in gamma spectrum**** Results are reported on an as received basis

unless otherwise noted

MDC - Minimum Detectable Concentration

t.-I

CI

0

0

0

Bolded text indicates reportable value.Page 6 of 6

Page 7: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

A%6W TELEDYNE01 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38010 1 of IC

James J. VouglitoisExelon Nuclear (Oyster Creek)P.O. Box 388US Route 9Forked River, NJ 08731

Report of Analysis/Certificate of Conformance

LMS #:

Project ID#Received:

Delivery Date

P.O.#:

Release #

3DG#:

03/24/2009

L38010

EX001-3ESPOC-06

03/16/2009

04/06/2009

01000298 REL#00010

This is to certify that Teledyne Brown Engineering - Environmental Services locatedat 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested anddocumented samples, as received by the laboratory, as specified in the applicable purchase order.

This also certifies that requirements of applicable codes, standards and specificationshave been fully met and that any quality assurance documentation which verifiedconformance to the purchase order is on file and may be examined upon request.

I hereby certify that the above statements are true and correct.

Keith Jeter - d -1Operations Manager

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-W-7 L38010-1 OY-W-7

OY-W-9 L38010-2 OY-W-9OY-W-10 L38010-3 OY-W-10

OY-W-12 L38010-4 OY-W-12

OY-W-13 L38010-5 OY-W-13OY-W-14 t 3006OY-W-14

OY-W-15 L38010-7 OY-W-15OY-W-16 [ L38010-8 OY-W-16

Page I of 6

Page 8: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

AV k-,W TELEDYNE?' BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38010 2 of 10

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-W-20 L38010-9 OY-W-20

OY-MW-IA-2A L38010-10 OY-MW-1A-2AOY-W-24 L38010-11 OY-W-24

OY-W-31 L38010-12 OY-W-31

OY-CST-9 L38010-13 OY-CST-9

Method Reference Numbers

Matrix Analysis Method Reference

Wo H-3 (DIST) EPA 906.0

This report shall not be reproduced or distributed except in its entirety.

Page 2 of 6

Page 9: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE32 9'2BROWN ENGINEERING, INC.

ID3124109 19:02 A Teledyne Technologies Company

L38010Exelon Nuclear (Oyster Creek)

EX001-3ESPOC-06

Sample ID: OY-W-7 Collect Start: 03/11/2009 10:20 Matrix: Ground Water (WG)Station: OY-W-7 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L3 80 10-1

Activity Uncertainty 1 Run Aliquot Aliquot Reference Count Count Count1Radionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3 (DIST) I-2011 [ -3.93E+01 I 1.I1E+02 I 1.87E+02 I pCi/L I I 10 - ml Ib03/23/091 60 I M lTFU" I 'Sample ID: OY-W-9 Collect Start: 03/10/2009 13:02 Matrix: Ground Water (WG)

Station: OY-W-9 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-2

Activity Uncertainty C Run Aliquot Aliquot[ Reference Count Count Count1Radionuclide soP# Cone 12 Sigma MDC Units I# Volume I Units Date Date Time Units Flag Values

H-3 (DIST) I 2011 --1.84E+01 I 1.12E+02 I 1.86E+02 I pCi/L I.. 1 10 I ml 1 03/23/091 60 I M I U ISample ID: OY-W-10 Collect Start: 03/10/2009 11:58 Matrix: Ground Water (WG)

Station: OY-w-10 Collect Stop: Volume:.Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-3

ActivityjUncertainty 1Run Aliquot IAliquot Referenc Count Count CountRadionuclide SOP# Cone 2 Sigma. # VoUnits nits Date Date Time Units Flag Values

H-3 (DIST) I 2011 I -6.76E+01 I 1.10E+02 I 1.89E+02 pCi/L I I 10 I ml 1 1 03/23/091 60 U M I U_____Sample ID: OY-W-12 Collect Start: 03/10/2009 14:27 Matrix: Ground Water (WG)

Station: OY-W-12 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-4

Activity Uncertainty Run Aliquot Aliquot. Reference Count ,Count CountRadionuclide SOPn Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3(DIST) 2011 I -4.05E+01 [ 1.08E+02 I 1.82E+02 I pCi/L [ I 10 I ml 1 03/23/091 60 6 M [ U I [

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum UjU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis 0oHigh = Activity concentration exceeds customer reporting ialue unless otherwise noted HSpec = MDC exceeds customer technical specification oL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery .

Bolded text indicates reportable value. 0Page 3 of 6

..0

Page 10: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:02 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38010Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-W-13 Collect Start: 03/10/2009 14:09 Matrix: Ground Water (WG)Station: OY-W-13 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38010-5

Radionuclide SOP#N Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3 (DI'ST) 1 2011 -4.38E+01I 1.05E+02 1.77E+02 pCi/L I 1 10 1 ml I 03/23/091 60 1 M U ISample ID: OY-W-14 Collect Start: 03/11/2009 08:43 Matrix: Ground Water (WG)

Station: OY-W-14 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-6

S Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC 7 Units # Volume Units Date Date Time Units Flag Values

H-3 (DIST) I 2011 I -1.38E+01I 1.12E+02 I 1.86E+02 1 pCi/L I I 10 I ml I 1 03/23/091 60 1 M I U ISample I): OY-W-15 Collect Start: 03/11/2009 09:41 Matrix: Ground Water - (WG)

Station: OY-W-15 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-7

Activity Uncertainty Run Aliquot IAliquot Reference Count Count CountRadlonuclide SOP# Cone 2 Sigma MDC Units 0 j Volume Units Date Date Time Units Flag Values

H-3 (DIST) -20"11 -7.24E+011 1.06E+02 1.83E+02 I pCi/L I 0 I ml [ 03/23/09[ 60 [ M USample ID: OY-W-16 - Collect Start: 03/10/2009 15:35 Matrix: Ground Water (WG)

Station: OY-W-16 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-8Activity c Uncertainty sRu Aliquot Aliquot Reference Count Count Count

Radionuclide SOP# Conc 2 Sigma MDC Units __ Volume Units Date Date Time Units Flag Values

H-3 (DIST) I 2011 I 2.20E+01 I 1.09E+02 I 1.78E+02 I pCi/L I I 10 mi ] I 03/23/091 60 I M 1 U I I I

Flag ValuesNo=PanoietfednU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MEIC and 3 sigma **** Results are reported on an as received basis c0High - Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification 0.L = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 4 of 6

H-.

Page 11: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE "03/24/09I BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38010Exelon Nuclear (Oyster Creek)

James J. Vouglitois EXOO I-3ESPOC-06

Sample ID: OY-W-20 Collect Start: 03/10/2009 14:40 Matrix: Ground Water (WG)Station: OY-W-20 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-9

Activity Uncertainty MRun Aliquot Aliquot Reference count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units N Volume Units Date Date Time Units Flag Values

-3 (DIST) 2011 1 -2.34E+00 115E+02 1.89E+02 I pCiL I 10 ml 1 03/24/091 60 1 M - U- I ISample ID: OY-MW-IA-2A Collect Start: 03/11/2009 10:30 Matrix: Ground Water (WG)

Station: OY-MW- IA-2A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-10

S Activity ,UncertaintyI Run Aliquot Aliquot Reference Count Count CountRadionuclide P Cone 2 Sigma C Units # I Volume Units Date Date Time Units Flag Values,

H-3 (DIST) - 2011 1 2.08E+01 I 1.15E+02 I1.87E+02 1 ii/L ý ,10 I ml 1 03/24/091 60 F M I U ISample ID: OY-W-24 Collect Start: 03/10/2009 10:51 Matrix: Ground Water (WG)

Station: OY-W-24 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-11

RdouldSO# Activity TUn-certainty M CUis Run Aliquot Aliquot Reference ICount Count Count gVleRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units FlagValues

H-3 (DIST) 1201 F7 8.1913+01 1.17E+02 1.84E02I- pCi/L I 10 I ml 1 F 03/24/09 60 F M I USample ID: OY-W-31 Collect Start: 03/10/2009 15:56 Matrix: Ground Water (WG)

Station: OY-W-3 t Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-12

Sp Activity U erinyRun Aliquot Aliquot Reference Count Count CountRadionuclide SOPN Cone 2 Sigma MDC Units # Volume Units Date I Date Time Units Flag Values

4-3 (DIST) 2011 .82E+01 1 1.13E+02 1.84E+02 pCi/L -10 I ml 1 03/24/091 60 F M U _____

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum W.* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma **** Results are reported on an as received basis 00High = Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification 0L = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery tnBolded text indicates reportable value. 0

Page 5 of 6

H=

Page 12: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis03/24/09 18:02

L38010Exelon Nuclear (Oyster Creek)

EX001-3ESPOC-06

TELEDYNEP9 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

James J. Vouglitois

Sample ID: OY-CST-9 Collect Start: 03/11/2009 15:33 Matrix: Ground Water (WG)Station: OY-CST-9 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38010-13

Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3 (DIST) 2011 1,68E+02 1.21E+02 1.82E+-02 pCi/L 10 ml 03/24/ 6 M U

Flag ValuesU =+ -

U* =

High =Spec =L =

H

Compound/Analyte not detected or less than 3 sigmaActivity concentration exceeds MDC and 3 sigma; peak identified(gamma only)Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigmaActivity concentration exceeds customer reporting valueMDC exceeds customer technical specificationLow recoveryHigh recovery

No = Peak not identified in gamma spectrumYes = Peak identified in gamma spectrum**** Results are reported on an as received basis

unless otherwise noted

MDC - Minimum Detectable Concentration

1-j

0~

0

Bolded text indicates reportable value.Page 6 of 6

Page 13: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

4Vj, TELEDYNE04 BROWN ENGINEERING, INC.

A Teladyne Technologies Company

2508 Quality LaneKnoxville, TN4 37931-3133865-690-6819

L38009 1 of 1

James J. VouglitoisExelon Nuclear (Oyster Creek)P.O. Box 388US Route 9Forked River, NJ 08731

Report of Analysis/Certificate of Conformance

03/24/2009

LIMS #: L38009

Project 1D# EX001-3ESPOC-06

Received: 03/16/2009

Delivery Date 04/06/2009

P.O.A: 01000298 REL#00010

Release #3DG#:

This is to certify that Teledyne Brown Engineering - Environmental Services locatedat 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested anddocumented samples, as received by-the laboratory, as specified in the applicable purchase order.

This also certifies that requirements of applicable codes, standards and specificationshave been fully met and that any quality assurance documentation which verifiedconformance to the purchase order is on file and may be examined upon request.

I hereby certify that the above statements are true and correct.

Keith JeterOperations Manager

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-LW-3 f L38009-1 OY-LW-3OY-LW-4 L38009-2 OY-LW-4OY-SW-2 L38009-3 OY-SW-2OY-W-2B L38009-4 OY-W-2BOY-SW-3 L38009-5 OY-SW-3OY-W-3A L38009-6 OY-W-3AOY-W-2A L38009-7 OY-W-2AOY-11-2A L38009-8 OY-iW-2A

Page I of 7

Page 14: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

,4Vk0 TELEDYNE'•1 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38009 2 of 1:

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-SW-I L38009-9 OY-SW-I

OY-MW-15K-IA L38009-10 OY-MW-15K-1A

OY-MW-16D L38009- I1 OY-MW-16DOY-MW-II-IA L38009-12 OY-MW-II-IA

OY-DWS L38009-13 OY-DWSOY-W-2 L38009-14 OY-W-2OY-W-3 L38009-15 OY-W-3OY-W-4 L38009-16 OY-W-4

OY-W-4A. L38009-17 OY-W-4AOY-W-4B L38009-18 OY-W-4BOY-W-5 L38009-19 OY-W-5OY-W-6 L38009-20 OY-W-6

Method Reference NAmbers

Matrix Analysis Method Reference

WG H-3 (DIST) EPA 906.0

TseT H-3 (DIST) EPA 9060

This report shall not be reproduced or distributed except in its entirety.

Page 2 of 7

Page 15: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38009Exelon Nuclear (Oyster Creek)

EX001-3ESPOC-06

Sample ID: OY-LW-3 Collect Start: 03112/2009 09:47 Matrix: Ground Water (WG)Station: OY-LW-3 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-1

Activity Uncertainty iRun Aliqo Alqo Reference Count on onRadionucide SOP#f Couc 2 Sigma Units # Volume Units Date Date Time Units Flag Values

(-3(DIST) 207 6.54E10+00 1.17E+02 1.92E+02 I pCi/L 1 10 1 ml F03/23/091 80 - M I U - TSample ID: OY-LW-4 Collect Start: 03/12/2009 09:40 Matrix: Ground Water (WG)

Station: OY-LW-4 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-2Activity Uncertainty Run -Aliquot Aliquot Reference ICount Count Count

Radionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

f---3(01ST) I 201l 1.72E+01 1 1.16E+02 1.89E+02 I pCiiL 1 10 - ml 03/23/091 80 1 M I U ISample ID: OY-SW-2 Collect Start: 03/09/2009 13:56 Matrix: Surface Water (WT)

Station: OY-SW-2 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-3

Activity Uncertaint Run Aliquot Aliquot Reference Count Count CountRadionuelide SOP#~ Coc 2 Sigma MDC Units # Volume Units Date Date Time Units Flag values

H-3(DIST) 2011 I -7.61E+01 I 1.13E+02 1.91E+02 pCi/L I 10 I ml I 03/23/09! 80 I M U I

Sample [D: OY-W-2B Collect Start: 03/10/2009 11:42 Matrix: Ground Water (WG)Station: OY-W-2B Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38009-4

Radionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3-1ST) ! 2011 2.58E+0 1 1. 16E+02 I 1.89E+02 pCiIL 10 I ml f 03/23/09 80 1 M I U!

Flag ValuesU = Compound/Analytc not detected or less than 3 sigma No - Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum tDU* - Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis 0High = Activity concentration exceeds customer reporting value unless otherwise noted oSpec MDC exceeds customer technical specification I'DL = Low recovery MDC - Minimum Detectable ConcentrationH = High recoveryWBolded text indicates reportable value. 0

Page 3 of 7

Page 16: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE34910BROWN ENGINEERING, INC.

03/24109 18-01 A Teledyne Technologies Company

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-SW-3 Collect Start: 03/10/2009 14:27 Matrix: Surface Water (WT)Station: OY-SW-3 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-5

"u F .Activity Uncertainty C Run Aliquot I Aliquot Reference Count Count Count F V

Radionuclide "SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

P-3 (DIST1) 2011 3.60E+01 1.15E+02 1.86E+02 pCi/L 1 10 I ml 1 "1 03/23/091 80 1 M i U 1Y TSample ID: OY-W-1A Collect Start: 03/10/2009 10:25 Matrix: Ground Water (WG)

Station: OY-W-lA Collect Stop: Volume:Description: Receive Date: 03116/2009. % Moisture:

LIMS Number: L38009-6

Activity Uncertainty FRun Alqo lqot F Reference Cut1Con onRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Tine Units Flag Values

H-3 (DIST) 2011 T-4.ioE+01 1. 13E+021 1.90E+02 f pCi/L I 10 ml 03/23/091 80 1 M USample ID: OY-W-2A Collect Start: 03/10/2009 11:05 Matrix: Ground Water (WG)

Station: OY-W-2A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-7

RActivity IUncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma M C Units # Volume Units Date Date Time Units Flag Values

-3 (DIST) 2011 I -6.55E+01 1 1.1OE+02 -1.86E+02 I pCi/L I I 10 mT l 1 103/23/091 80 1 M IU ' ISample ID: OY-11-2A Collect Start: 03/10/2009 13:40 Matrix: Ground Water (WG)

Station: OY- 11-2A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-8

Radionuclide SOP# Cone 2 Sigma MDC Units N Volume Units Date Date Time Units Flag Values

-3 (DIST) ... 2011 I 2.65E1+01 1.19E+02 1.94E+02 1 pCiiL K1 10 ml 1 03/23/091 80 I M I U I

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma *** Results are reported on an as received basis 00High = Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification WL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 4 of 7

Ha

Page 17: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A TeedyaoTechnologies Company

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-SW-I Collect Start: 03/11/2009 12:38 Matrix: Surface Water (WT)Station: OY-SW-I Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-9

Activity 'Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide S P# Conc 2 Sigma MDC Units #n Volume Units Date Date Time Units Flag Values_ _ _ _ _ _ _ _ _ _ _ _ _ _ Ji __ __ _ _ _

-3 (DIST) T 2011 -6.38E+01 1.07E+02 1.81E+02 pCi/L 1 10 ml T 1 03/23/09 80 7 M .- U ISample ID: OY-MW-15K-1A Collect Start: 03/10/2009 11:34 Matrix: Ground Water (WG)

Station: OY-MW-15K-IA Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-10

Activity Uncertaintyf Run Alquot I Aliquot Reference Count Count CountRadionuclide SOP# Colnc 2 Sigma MDC Units i#n Volume Units, Date Date Time Units Flag Values

R-3 (DIST) i 2-011- 4.57E+01 1.18E+02 1.92E+02 F pCi/L I 10 1 ml 1 03/23/091 80 1 M IU I I ISample ID: OY-MW-16D Collect Start: 03/10/2009 13:10 Matrix: Ground Water (WG)

Station: OY-MW-16D Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-1 1Activity Uncertainty Run Aliquot Aliquot Reference Count Count Count

Radionuclide SOP# Conc 2 Sigma MDC Units n Volume Units Date Date Time Units Flag Values

H-3 (DIST) 2011 6.57E+01 l 1.16E+02 ' 1.86E+02 pCi/L I[0 10 I ml 03/23/09F 80 1 M U ISample ID: OY-MW-1I-1A Collect Start: 03/10/2009 14:05 Matrix: Ground Water (WG)

Station: OY-MW-11-IA Collect Stop: Volume:Description:. Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-12

I n n un Aliquot Aliquot Reference ount Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

.{-3 (DIST) 2011 8.08E+01 1.20E+02 1.92E+02 1pCi/ 10 ml 03/24/09 80 M U7

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum WU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis 00High = Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification u t oL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery Ul

Bolded text indicates reportable value. 0Page 5 of 7

Page 18: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis 7 TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A Teledyne Technolooies Compasny

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-DWS Collect Start: 03/11/2009 13:15 Matrix: Ground Water (WG)Station: OY-DWS Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-13

Sop# Activity Uncertainty M Run Aliquot Aliquot Reference Count Count CountRadionuclide O Cone 2 Sigma MDC Units N Volume Units Date Date Time Units Flag Values

R-3(DIST) - 201i -6.58E+00 1.17E+02 1 1.93E-+-02 pCi/L I 1 10 1 ml I 03/24/091 80 1 M IU I [T

Sample ID: OY-W-2 Collect Start: 03/10/2009 15:25 Matrix: Ground Water (WG)Station: OY-W-2 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-14

Ra cActivityi. Uncertainty Run Aliquot Aliquot Reference Count Count CountIRadionuclide Conc 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3 (DIST) 12011 1 -3.48E+01 I 1.15E+02 1.92E+02 1 pCi/L 1 [ 10 1 ml 1 03/24/091 80 1 M I U I ISample ID: OY-W-3 Collect Start: 03/10/2009 10:18 Matrix: Ground Water (WG)

Station: OY-W-3 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-15

Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

H-3 (DIST) -201 8.89E+0L ! 1.20E+02 I 1.91E+02 pCiL ! I 10 I ml ! !03/24/091 80 1 M I U I

Sample ID: OY-W-4 Collect Start: 03/10/2009 10:52 Matrix: Ground Water (WG)Station: OY-W-4 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-16

Activity Uncertainty Run Aliquot Aliquot Reference Count 1 CountRadionuclide SOP# Cone 2 Sigma MDC Units N Volume Units Date Date Time Units Flag Values

- .DS 2011 9.15E+01 1.18E+02 I 1.87E+02 pCi/L I - 10 1 ml I IT03/24/091 80 [ M I U I

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(ganuna only) Yes = Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma *** Results are reported on an as received basisHigh - Activity concentration exceeds customer reporting value unless otherwise noted ,Spec = MDC exceeds customer technical specification oL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value.Page 6 of 7

Page 19: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE0/401:0BROWN ENGINEERING, INC.

03124/09 18:01 A Teledyne Tachlinoogies Company

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-W-4A Collect Start: 03/11/2009 11:11 Matrix: Ground Water (WG)Station: OY-W-4A Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38009-17

Activity Uncertainty [I Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units 4 Volume Units Date Date Time Units Flag Values

--3(DIST) f 2011 4.25E+01 1.15E+02 1.87E+02 I pCi/L 1 I 10 1 ml 1 03/24/091 80. M UI Sample 1D: OY-W-4B Collect Start: 03/11/2009 11:01 Matrix: Ground Water (WG)

Station: OY-W-4B Collect Stop:. Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-18

Activity Uncertainty IRun Aliquot Aliquot Reference Cot Cunt CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3(DIST) I 2011 9.22E+01 1.19E+02 1.89E+02 pCi/L 1 10 1. ml 1 [ 03/24/091 80 f M USample 1D: OY-W-5 Collect Start: 03/11/2009 08:58 Matrix: Ground Water (WG)

Station: OY-W-5 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-19

Activity Uncertint1T Run Aliquot Aliquot Reference Count icount CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3(1-1ST) I 20-11 -1.05E+01 1.11E+02 1.84E+02 pCi/L I 10 I ml T 1 03/24/091 80 1 M I U I ISample I): OY-W-6 Collect Start: 03/11/2009 09:25 Matrix: Ground Water (WG)

Station: OY-W-6 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-20

Activity Uncertainty T Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3 (DIST) 2011 V2.39E+01 1 I7E-02 1.91E+02 T pCi/L [ 10 1 ml 1 1 03/24/091 80 I M I U I I

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma \ No - Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gammna only) Yes - Peak identified in gamma spectrum WU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis 00High = Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification roL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 7 of 7

Page 20: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

1206,TELEDYNEN BROWN ENGINEERING, INC.

ATeledyne Technologies Coparny

2508 Quality LaneKnoxville, TN 37931-3133865-690-6819

L38009 1 of 1

James J. VouglitoisExelon Nuclear (Oyster Creek)

P.O. Box 388US Route 9Forked River, NJ 08731

Report of Analysis/Certificate of Conformance

LIMS #:

Project ID#

Received:

Delivery Date

P.O.#:-,Release #

3 DG#:

03/24/2009

L38009

EX001-3ESPOC-06

03/16/2009

04/06/2009

01000298 REL.#00010

This is to certify that Teledyne Brown Engineering - Environmental Services locatedat 2508 Quality Lane, Knoxville, Tennessee, 37931, has analyzed, tested anddocumented samples, as received by the laboratoryi as specified in the applicable purchase order.

This also certifies that requirements of applicable codes, standards and specificationshave been fully met and that any quality assurance documentation which verifiedconformance to the purchase order is on file and may be examined upon request.

I hereby certify that the above statements are true and correct.

Keith Jeter "6/ -Operations Manager

Cross Reference Table

Client ID Laboratory ID Station ID (if applicable)OY-LW-3 L38009-1 OY-LW-3OY-LW-4 I L38009-2 OY-LW-4

OY-SW-2 ] L38009-3 OY-SW-2OY-W-2B i L38009-4 OY-W-2B

OY-SW-3 L38009-5 OY-SW-3

OY-W-lA L38009-6 OY-W-lA

OY-W-2A! L38009-7 OY-W-2A

OY-11-2A 1 L38009-8 OY- 11-2A

Page I of 7

Page 21: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

• j6 TELEDYNE' ' BROWN ENGINEERING, INC.

A Teledyne Technologies Company

2508 Quality LaneKnoxville, TN 3793 1-3133865-690-6819

L38009 2 of 1'

Cross Reference Table

Client ID Laboratory ID Station ED (if applicable)OY-SW-l L38009-9 OY-SW-1

OY-MW-I5K-IA j L38009-10 OY-MW-15K-1AOY-MW-16D I L38009-11 OY-MW-16D

OY-MW-1I-IA L38009-12 OY-MW-1I-IAOY-DWS L38009-13 OY-DWSOY-W-2 L38009-14 OY-W-2OY-W-3 L38009-15 OY-W-3OY-W-4 L38009-16 OY-W-4OY-W-4A L38009-17 OY-W-4AOY-W-4B L38009-18 OY-W-4BOY-W-5 L38009-19 OY-W-5OY-W-6 L38009-20 OY-W-6

Method Reference Numbers

Matrix Analysis Method Reference

HWG -3 (DIST) EPA 906.0WT H-3 (DIST) EPA 906.0

This report shall not be reproduced or distributed except in its entirety.

Page 2 of 7

Page 22: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis q TELEDYNE03/24/09 18:01 v BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38009Exelon Nuclear (Oyster Creek)

EXO0 1-3ESPOC-06

Sample ID: OY-LW-3 Collect Start: 03/12/2009 09:47 Matrix: Ground Water (WG)Station: OY-LW-3 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-1- Activity IUncertainty Run Aliquot Aliquot Referene Con Count COun

Radionuclide Conc 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

H-3(DIST) I 2011 6.54E+00 [ 1.17E+02 1 1.92E+02 pCi/L I 10 1 ml 03-/23/09 80 M iU I ISample I0: OY-LW-4 Collect Start: 03/12/2009 09:40 Matrix: Ground Water (WG)

Station: OY-LW-4 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-2Activity Uncertainty Run Aiquot Aiquot Reference Count Count 1 Count

Radionuclide L .SOP# Cone 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

H-3 (DIST) - 2011 .1.72E+0l 1.16E+02 1.89E+02 I pCi/L I 1 10 I ml1 03/231091 80 1 M I U ISample ID: OY-SW-2 Collect Start: 03/09/2009 13:56 Matrix: Surface Water (WT)

Station: OY-SW-2 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-3Activity Uncertainty Run Aliquot Aliquot Reference Count Count Count1

Radionuclide SOP# Conc 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

-3(DIST) 121 -7.61E+01 1 1.13E+02 1.91E+02 pCi/L I T 10 1 ml 03/231091 80 M USample ID: OY-W-2B Collect Start: 03/10/2009 11:42 Matrix: Ground Water (WG)

Station: OY-W-2B Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-4Activity Uncertainty f Run Aliquot Aliquot Reference Count Count Count 1

Radionuclide SOP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units J Flag Values

H-3 (DIST) 1-2011 I 2.58E+01 1.16E+02 i.89E+02 f pCi/L 1 1 10 1 ml 1 1 03/23/091 80 1 M I U I I I

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* - Compound/Analyte-not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma *** Results are reported on an as received basis 0•High Activity concentration exceeds customer reporting value unless otherwise notedSpec = MDC exceeds customer technical specification I'DL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery W

Bolded text indicates reportable value. 0Page 3 of 7

1-..•

Page 23: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A Teledyne Technologies Compeny

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-SW-3 Collect Start: 03/1012009 14:27 Matrix: Surface Water (WT)Station: OY-SW-3 Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-5

Activity Uncertainty MD .is Run Aliquot IAliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units Volume Units Date Date Time Units j Flag Values

R-3 (DIST) 2011 3.60E+01 1.15E+02 1.86E+02 pCi/L I i 10 I ml I 03/23/091 80 UM iY "'FVSample ID: OY-W-1A Collect Start: 03/10/2009 10:25 Matrix: Ground Water (WG)

Station: OY-W-1A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-6

s Activity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Coc 2Sma Units Volume Units Date Date Time Units Flag Values

H-3-(DIST) I 2011 - 4.1OE+0 I 1.13E+02 I 1.90E+02 I pCi/L 1 I 10 I ml I I 03/23/091 80 I M I U ISample ID: OY-W-2A Collect Start: 03/10/2009 11:05 Matrix: Ground Water (WG)

Station: OY-W-2A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-7

. o# Activity ýUncertainty [Run IAliquot Aliquot I Reference ICount Count ICountRadiouciide SP Con 2LSigma MDC Units Volume Units Date Date Time J Units Flag Values

R-3 (DIST) 21 -i-1 -6.55E+01 I 1.I1E+02 I 1.86E+02 pCi/L I I 10 I ml I I 03/23/091 80 U M U ISample ID: OY-11-2A Collect Start: 03/10/2009 13:40 Matrix: Ground Water (WG)

Station: OY-1-2A - Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-8

I Activity Uncertainty Run Aliquot Aliquot Reference I Count Count 1 CountRadionuclide SOP# Conc 2 Sigma MDC Units N Volume Units Date Date Units Flag Values

A--3-(DST) 02I-- 2.651+01 [ 1.19E+02 I 1.94E+02 pCiIL I I 10 1 ml 1 I 03/23/091 80 1 M I U I T7

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis coHigh = Activity concentration exceeds customer reporting value unless otherwise noted oSpec = MDC exceeds customer technical specificationL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 4 of 7

Page 24: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE02010BROWN ENGINEERING, INC.

03/24/09 18:01 A Teledyne Technologies Company

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-SW-I Collect Start: 03/11/2009 12:38 Matrix: Surface Water (WT)Station: OY-SW-I Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-9

Activity Uncertainty Run Aliquot I Aliquot Reference Count Count CountRadionuclide SOP Conc 2 Sigma MDC Units u4 Volume Units Date Date Time Units Flag Values

0-3 (DIST) 20-11-' [-6.38E+01 II 1.07E+02 I 1.81E+02 I pCi/L 1 . 10 ml 1 03/23/091 80 I M I FU" I FSample ID: OY-MW-15K-IA Collect Start: 03/10/2009 11:34 Matrix: Ground Water (WG)

Station: OY-MW-15K-1A Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-10

So# Activity jUncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide Cone j 2 Sigma MDC Units a Volume Units' Date Date Time Units Flag Values

-3 (iST) [2011 I4.57E+01 i.18E+02 1.92E+02 pCOEL I I 10 1 ml I I 03/23/091 80 I M I U I I JSample ID: OY-MW-16D Collect Start: 03/10/2009 13:10 Matrix: Ground Water (WG)

Station: OY-MVW-16D Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-11

Radionuclide SON Con c 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

F-3 (DIST) - 2011 f6.57E+01 I1.16E+02 F 1.86E+02 F pCi/L I 10 nil 1 03/23/091 80 I M I U I ISample ID: OY-MW-11-1A Collect Start: 03/10/2009 14:05 Matrix: Ground Water (WG)

Station: OY-MW-1I-IA Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-12

# Activity UncrtintyUn Run I Aliquot Aliquot Reference Count Count CountRadionuclide SOP Cone 2 Sigma MDC Units Volume Units Date Date Time Units Flag Values

-3 (DIST) I 2011 I 8.08E+01 1 1.20E+02 1 1.92E+02f pCi/L I 1 10 I m2 1 03/24/091 80 1 M UTI U 1

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum C')U* = Compound/Anaiyte not detected. Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis OHigh = Activity concentration exceeds customer reporting value unless otherwise notedSpec = MDC exceeds customer technical specificationL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery trl

Bolded text indicates reportable value. 0Page 5 of 7

I-.,

Page 25: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A Teledyne Technologies Company

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-DWS Collect Start: 03/11/2009 13:15 Matrix: Ground Water (WG)Station: OY-DWS Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-13

RdouieIActivity Uncertainty Run Aiquot Alquot Reference iCount Count CountRadionuclide SO# Cone 2 Sigma MDC Units # Volume Units Date .....Date Time Units Flag Values

H-3 (DIST) 2011 -6.58E+00 1.17E+02 I 1.93E+02 pCi/L 10 ml [ 03/24/09R 80 M U T I ISample ID: OY-W-2 Collect Start: 03/10/2009 15:25 Matrix: Ground Water (WG)

Station: OY-W-2 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LEMS Number: L38009-14Activity Uncertainty Run Aliquot Aliquot Reference Count Count Count

Radionuelide _SOP# Cone '2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

f-3 (DIST) 2011 -3.48E+01 1. .15E+02 7 1.92E+02 I pCi/L 10 ml 03/24/091 80 1 M I U ISample ID:. OY-W-3 Collect Start: 03/10/2009 10:18 Matrix: Ground Water (WG)

Station: OY-W-3 Collect.Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-15Activity Uncertainty . Run Aliquot Aliquot Reference Count Count Count

Radionuclide SOP# Cone 2 Sigma MDC Units u Volume Units Date Date Time Units Flag Values

H-3 (DIST) 21- I 8.89E+01 1.20E+02 1.91E+02 1 pCi/L I 10 ml I 03/24/091 80 1 M' I U ISample ID: OY-W-4 Collect Start: 03/10/2009 10:52 Matrix: Ground Water (WG)

Station: OY-W-4 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-16

d Activity Uncertainty Run I Aliquot Aliquot Reference Count Cou CountIRadionuclide SOP Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

13 (_DIST) I -20 1 9.I1E+01I 1.18E+02 I 1.87E+02 pCi/L I I. 10 I ml 103/24/091 80 I M U I .

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrum twU* = Compound/Analyte not detected' Peak not identified, but forced activity concentration exceeds MDC and 3 sigma * Results are reported on an as received basis coHigh - Activity concentration exceeds customer reporting value unless otherwise noted 0Spec = MDC exceeds customer technical specification oL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery

Bolded text indicates reportable value. 0Page 6 of 7

Page 26: AfW TELEDYNE L38010 1 of IC 01 BROWN … AfW TELEDYNE 01 BROWN ENGINEERING, INC. A Teledyne Technologies Company 2508 Quality Lane Knoxville, TN 37931-3133 865-690-6819 L38010 1 of

Report of Analysis TELEDYNE03/24/09 18:01 BROWN ENGINEERING, INC.

A Teladyne Techaoagies Compa

L38009Exelon Nuclear (Oyster Creek)

James J. Vouglitois EX001-3ESPOC-06

Sample ID: OY-W-4A Collect Start: 03/11/2009 11:11 Matrix: Ground Water (WG)Station: OY-W-4A Collect Stop: Volume:

Description: Receive Date: 03/16/2009 % Moisture:LIMS Number: L38009-17

Activity Uncertainty R Aliquot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units # N Volume Units Date Date Time Units Flag Values

•I-3 (DIST) 2011 4.25E+01 '1.15E+02 1.87E+02 F pCi/L 1 10 W ml 1 03/24/091 80 1 M 1 USample H1): OY-W--4B Collect Start: 03/11/2009 11:01 Matrix: Ground Water (WG)

Station: OY-W-4B Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-18

Radionuclide OP# Cone 2 Sigma MDC Units # Volume Units Date Date Time Units Flag Values

T-3( •-ST) I 201 i 9.22E+01 1.119E+02 1.89E+02 pCi/L 10 1 ml 03/24/09 80Sample ID: OY-W-5 Collect Start: 03/11/2009 08:58 Matrix: Ground Water (WG)

Station: OY-W-5 CollectStop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

L1MS Number: L38009-19

IActivity Uncertainty Run Aliquot Aliquot Reference Count Count CountRadionuclide SOPM Conc 2 Sigma MDC Units 4 Volume Units Date Date Time Units Flag Values

-3(DIST) 2011 1.IIE+02 ( 1.84E+02 pCi/L I 1 10 ml I 03/24/091 80 W M I USample ID: OY-W-6 Collect Start: 03/11/2009 09:25 Matrix: Ground Water (WG)

Station: OY-W-6 Collect Stop: Volume:Description: Receive Date: 03/16/2009 % Moisture:

LIMS Number: L38009-20

Activity Uncertaint Run Aiot Aliquot Reference Count Count CountRadionuclide SOP# Cone 2 Sigma MDC Units u Volume Units Date Date Time Units Flag Values

ýR--3 (FDIST) - 2011 7 2.39E+01 7 1.17E+02 1.91E+02 I pCi/L I 1 10 1 ml 1 03/24/091 80 I M I U - I ] 1

Flag ValuesU = Compound/Analyte not detected or less than 3 sigma No = Peak not identified in gamma spectrum+ = Activity concentration exceeds MDC and 3 sigma; peak identified(gamma only) Yes = Peak identified in gamma spectrumU* = Compound/Analyte not detected. Peak not identified, but forced activity concentration exceeds MD and 3 sigma * Results are reported on an as received basis 0oHigh = Activity concentration exceeds customer reporting value unless otherwise noted OSpec = MDC exceeds customer technical specification WL = Low recovery MDC - Minimum Detectable ConcentrationH = High recovery -1Bolded text indicates reportable value. 0

Page 7 of 7