Advantech Fieldbus I/O System
I d t i l A t ti GIndustrial Automation Group
Fieldbus Solution -- Industrial Ethernet
Global Industrial Ethernet
EtherCAT, 4%
POWERLINK, 11%
Other, 5% 4%
11% 4%www.ethernet-powerlink.org www.ethercat.org
EtherNet/IP, 30%
www odva org
Modbus TPC/IP, 22%
30%www.odva.org
PROFINET, 28%
22%www.modbus.org
S IMS R h 2010
22%28%
www.profibus.com
Source: IMS Research, 2010
Advantech Remote I/O on Ethernet
ctFa
mily
Protocols
mFa
ctor
derin
g
FormFactor
Hardware &Specifications
/TC
P
t/IP
ET
ed al B
us
ar lots
ules
hain
mp
rver
P2P ve
r
Pro
duc
Form
Ren
MO
DB
US
/
Eth
erN
et
PR
OFI
N
Cer
tifi e
AP
AX
Loca
Mod
ula
Rac
k/ S
l
I/O M
odu
Dai
sy C
h
Wid
e Te
Web
Ser
GC
L &
P
.NE
TD
ri
√ √ADAM-5000/TCP √ 4 26 √ADAM-5000LTCP √ 8 26 √
ADAM-6000 √ √ 10 √ √ √ADAM 6000 √ √ 10 √ √ √ADAM-6100EI √ √ √ 7 √ADAM-6100PN √ √ √ 7 √
ADAM-6200 √ √ 7 √ √ √ √APAX-5070 √ √ √ 32 10 √
√ √ √ √ 32 10 √APAX-5070 √ √ √ √ 32 10 √APAX-5070 √ √ √ √ 32 10 √DMU-3000 √ √ 1 √DMU 3000 √ √ 1 √
Reduce Complex I/O Wiring
The disadvantage for long distance direct I/O wiring– Signal decay and interference– Difficult on deployment
Difficult on fault diagnosis– Difficult on fault diagnosis– Difficult on maintain and upgrade
One Cable from controller to collect data Simple and Tidy
Rack vs. Modular
Racks are used where there is a higher density of sensors and actuators in close physical proximity; such as valve p y p y;manifolds or an array of proximity sensors.Modules are used to for connecting a few points of I/O such
h ddi t k li ht t hias when adding a stack light to a machine.
High Density, fewer Node ID / IP required
Easy Connection & flexible
Can Racks and Modules be Mixed?
EKI-2525Un managed 10/100
EthernetPROFINETto Control Yes!Un-managed 10/100
Switch
ADAM-6117PNLevel Sensors ADAM-6117PN
Level SensorsAPAX-5071PROFINETPROFINET
CommunicationCoupler
Valve Manifold
What about EtherNet/IP?
EKI-2548I
EthernetEtherNet/IPto Control Yes!EKI-2548I
Managed10/100 Switch
/w IGMP Snooping
ADAM-6117EILevel Sensors ADAM-6117EI
Level SensorsAPAX-5072EtherNet/IPEtherNet/IP
CommunicationCoupler
Valve ManifoldIGMP
Snooping?
IGMP Snooping
IGMP means Internet Group Management ProtocolsIGMP means Internet Group Management Protocols.
IGMP snooping means listening to the IGMP communications being passed through a switch The switch must be “managed” to have thispassed through a switch. The switch must be managed to have this feature and when enabled, will automatically optimize IGMP communication.
The primary objective of IGMP snooping is to filter Multicast transmissions. Implicit connections use multicasting, which means the speed and efficiency of the I/O related communication is significantly i dincreased.
The significance of this is more reliable determinism allowing the term “real-time” to be used in conjunction with the I/O messagingreal-time to be used in conjunction with the I/O messaging.
Simple, It just works
Ethernet Ethernet
WebOPCIP ControlLogix
Eth t T NA-B
ControlLogix ControllerRemote I/O EtherNet/IP
Implicit ConnectionEthernet Tag Namebased protocol
ControlLogix Controller(Scanner)
Implicit Connection(Adapter)
CIP, or Common Industrial Protocol, is the name of the family of protocols under the auspices of ODVA. The ControlLogix Tag Name protocol is not under ODVA but is communicated in a satndard CIP packet and is usedunder ODVA but is communicated in a satndard CIP packet and is used by ControlLogix 5000.
Siemens will also Work
Ethernet Ethernet
WebOP SimaticS7 Ethernet Protocol
SiemensS7 Controller
Remote I/OPROFINET
The ADAM-6100 and APAX-5071 Series Ethernet based remote I/O modules are designed to work as slave remote I/O to a controller. odu es a e des g ed o o as s a e e o e /O o a co o e
APAX I/O Concept
SpeedThe speed of transmission of Ethernet is the single most significant factor for the acceptance of Ethernet as a viable network supporting remote I/O.
10BASE-T 1990 Ethernet 10 Mbit/s10BASE T 1990 Ethernet 10 Mbit/s100BASE-TX 1995 Fast Ethernet 100 Mbit/s1000BASE-T 1999 GigE 1,000 Mbit/s10GBASE-T 2006 10 GigE 10 Gbit/s100 GbE 2010 100 Gbit/s
Keeping pace with Moore’s Law.
1 000 bits = 1 kbit1,000 bits = 1 kbit1,000 kbit = 1 Mbit1,000 Mbit = 1 Gbit1,000 Gbit = 1 Tbit,
Eth t t d t i i tiC t Eth t t h l i d t i i tiThe Determinism Obstacle
Ethernet was not deterministic.Current Ethernet technology is deterministic.
Collision
Hubs are not deterministic, they only support half-duplex Ethernet.Switches are full duplex, faster, and more efficient, so that collisions do not occur. At only 10 Mbps networks are prone to collisions.Ethernet today is deterministic within its bandwidth.
Speed and DeterminismThe delivery van must be fast and reliable enough to deliver a packet under the worst predictable conditions. The deterministic condition is that it must reach its
destination by noon every day.y y y
PacketDeli erPacket
Deli erPacket
D liDeliveryDelivery Delivery
Van arrives at 9:00 amVan leaves at 8:00 amVan leaves at 9:30 am Van arrives at 11:30 am
S it h d k th Eth t bl t t “ l ti ” I/O B t it h d
Switches Add LatencySwitches do make the Ethernet able to support “real-time” I/O. But, a switch does
not simply pass a communication packet through, it processes the packet to varying degrees, and this takes time.
An old rule of thumb was 3 – 4 – 5.
RealReal--time Ethernet I/Ostime Ethernet I/Os-- ADAMADAM--6000EI & ADAM6000EI & ADAM--6000PN Series6000PN Series
Feature: Daisy-chain Connection
Each ADAM-6100 module has built-in Ethernet switches toEach ADAM 6100 module has built in Ethernet switches to allow Daisy-chain connectionHelping improve scalability of I/OSaving wiring cost
legacylegacy
Feature: Ethernet-based Configuration Tool
ADAM NET Utilit b dl d ith h ADAM 6100 d lADAM.NET Utility comes bundled with each ADAM-6100 moduleHelping set, configure and test ADAM-6100 modulesMaking the modules ready for PLC systems before runningMaking the modules ready for PLC systems before running
legacylegacy
Feature: 2,500 VDC Isolation Protection
Isolation between power supply input/outputIsolation between power supply, input/output, and Ethernet communicationMaking sure the operation of each module won’t be affected by others
legacylegacy
Feature: 2,500 VDC Isolation Protection
Three mounting ways:Three mounting ways:- Wall Mounting- DIN-rail Monuting
Pi b ki- Piggybacking
legacylegacy
ADAM-61/6200 SeriesADAM-61/6200 Series
ADAM-6100EI Series ADAM-6100PN Series ADAM-6200 Series TypeADAM-6100EI Series ADAM-6100PN Series ADAM-6200 Series Type
ADAM-6117EI ADAM-6117PN ADAM-6217 8 x Analog In
ADAM-6118EI ADAM-6118PN ADAM-6218 7x Thermocouple
ADAM-6124EI ADAM-6124PN ADAM-6224 4 x Analog Out
ADAM-6150EI ADAM-6150PN ADAM-6250 7/8 x Digital In / Out
ADAM-6151EI ADAM-6151PN ADAM-6251 16 x Digital In
ADAM-6156EI ADAM-6156PN ADAM-6256 16 x Digital Out
ADAM-6160EI ADAM-6160PN ADAM-6260 6 x Relay OutADAM 6160EI ADAM 6160PN ADAM 6260 6 x Relay Out
High Density Remote I/Os High Density Remote I/Os g yg y-- APAXAPAX--5070 Series5070 Series
Expand I/O in Existing Project
Main Control System with Existing Fieldbus Protocolg
APAX‐5070 APAX‐5071 APAX‐5072 APAX‐5073Coming soon
CouplerCoupler
Coming soon
POWERLINK, 11%
Other, 5%
EtherCAT, 4% , 0 , 0
Up to 32 I/O module with Flexible topology
EtherNet/IP,
30%
ModbusTPC/IP,
22% p gyPROFINET
, 28%
22%
Key Feature: Flexible Topology APAX I/O APAX I/O
Consume only one node
APAX I/O
ID / IP from Controller
Ethernet Switch
APAX I/OAPAX-507x
Remain real-time performance Benefit: Decrease coupler number
(Fewer IP address used)
Key Feature: Daisy-Chain Connection
Two LAN ports support both line and star topologyB fit S i t ll ti tBenefit: Save installation cost
Key Feature: Fail Safety Value (FSV)
APAX-5000 Output Modules (DO, AO) Support.Output Channel Become Pre-defined Value While Loosing Connection with Control System
Key Feature: Alarm Function
User can configure specific input channels’ value to trigger specific h l loutput channels as alarm
Total 16 alarms availableBenefit: Enable APAX-507x intelligence featureBenefit: Enable APAX 507x intelligence feature
Featured IO Modules
High Density I/OAI/O: 12 channels DI/O: 24 channelsAI/O: 12 channels, DI/O: 24 channelsSave installation space and cost
Hot-Swap I/OInsert/remove modules without shutdown systemSave operation cost
Flexible Range for Analog ModulesFlexible Range for Analog ModulesEach channel configured with different rangeSave stock cost Ch0: 10 VSave stock cost
Ch2: K-type T/C
Ch1: 4 ~ 20 mA
Ch0: 10 V
APAX-IO Modules, Easy and Friendly
Friendly Design for Installation and Debugging
Hot Swappable Cl TppI/O Module Design
Clamp Type Terminal Block
Easy Identification by Color-matched Connector
Writable Label with Wiring InformationConnector Information
Completed IO Modules Offering
AI AO DI DI/O DO
APAX-5017, 5017H APAX-5028 APAX-5040 APAX-5045 APAX-5046
RelayCounterAI PWM
APAX-5060APAX-5080APAX-5013, 5018 APAX-5082