ademco v120 user manual

58
VISTA-120 Security System User Guide * N5943-8V2 9/98 ®

Upload: -

Post on 28-Mar-2015

123 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Ademco V120 User Manual

VISTA-120Security System

User Guide

*

N5943-8V2 9/98

®

Page 2: Ademco V120 User Manual

– 2 –

TABLE OF CONTENTS

SYSTEM OVERVIEW.................................... 3A Partitioned System................................ 3Zones.................................................... 3Fire Protection......................................... 4Burglary Protection .................................. 4Alarms................................................... 4Memory of Alarm...................................... 4Speed Keys (Macros) ............................... 5Using Schedules...................................... 5Device Timers ......................................... 5Accessing other partitions (GOTO command) 5Master Keypad Operation.......................... 6Self-Help Feature ..................................... 6Phone Access & Voice Response ............... 6

FUNCTIONS OF THE KEYPADS ...................... 7ENTRY/EXIT DELAYS.................................. 10DISPLAYING ALL ZONE DESCRIPTORS ......... 10CHECKING FOR OPEN ZONES...................... 11BYPASSING PROTECTION ZONES................ 12

Quick Bypass ........................................ 13Displaying Bypassed Protection Zones ....... 13

ARMING PERIMETER ONLY (STAY) ............... 14ARMING PERIMETER ONLY (INSTANT)........... 15ARMING ALL PROTECTION (AWAY) ............... 16ARMING ALL PROTECTION (MAXIMUM).......... 17DISARMING AND SILENCING ALARMS........... 18USING KEYSWITCHES ................................ 19CHIME MODE............................................. 20ACCESS DOOR CONTROL............................ 21PANIC KEYS.............................................. 22

SPEED KEYS (MACROS) ............................. 23USING #70 RELAY MENU MODE.................... 24VIEWING CENTRAL STATION MESSAGES...... 25SECURITY CODES & AUTHORITY LEVELS...... 26

Duress Code.......................................... 26Quick Arming......................................... 26Authority Levels..................................... 27To Add A User ........................................ 29To Change A User's Code......................... 31To Delete A User..................................... 31

ACCESSING OTHER PARTITIONS................. 32GOTO Command .................................... 32Global Arming ........................................ 32Master Keypad Operation......................... 32Common Area Operation .......................... 34How User Codes Affect the Common Area.... 35

USING SCHEDULES.................................... 36Delaying The Closing Time........................ 36Temporary Open/Close Schedules............. 37Programming Temporary Schedules ........... 38

PROGRAMMING DEVICE TIMERS ................. 40TESTING THE SYSTEM................................ 42FIRE ALARM SYSTEM ................................. 43TROUBLE CONDITIONS............................... 44MAINTAINING YOUR SYSTEM ...................... 46QUICK GUIDE TO SYSTEM FUNCTIONS ......... 48SUMMARY OF AUDIBLE NOTIFICATION ......... 51INSURANCE CREDIT REQUEST FORM ........... 53ADEMCO LIMITED WARRANTY ..................... 56EVENT LOGGING COMMANDS .............. Tearout

Page 3: Ademco V120 User Manual

– 3 –

SYSTEM OVERVIEWGeneral Congratulations on your ownership of an Ademco Partitioned

Security System. You've made a wise decision in choosing it, forit represents the latest in security protection technology today.Ademco is the world's largest manufacturer of security systemsand millions of premises are protected by Ademco systems.

This system offers you three forms of protection: burglary, fireand emergency. To realize the system's full potential, it isimportant that you feel comfortable in operating it. Your systemconsists of at least one keypad which provides full control ofsystem operation, various sensors which provide perimeter andinterior burglary protection, plus a selected number of strategicallyplaced smoke or combustion detectors designed to provide earlywarning in case of fire.

The system uses microcomputer technology to monitor allprotection zones and system status, initiates alarms andprovides appropriate information for display on the keypad(s)used with the system. Your system may also have beenprogrammed to automatically transmit alarm or status messagesover the phone lines to a central alarm monitoring station.

A PartitionedSystem

Simply stated, a partitioned system shares one physical alarmsystem among different users, each with their own requirements.For the most part, you as a user need not know about otherusers and their structure in the system, but from time to time, youmay see display messages which indicate the system is in useby another user. Do not be concerned, this is normal. Refer to theACCESSING OTHER PARTITIONS section for additionalinformation.

Zones Your system's sensing devices have been assigned to various"zones." For example, the sensing device on your Entry/Exit doormay have been assigned to zone 001, sensing devices onwindows in the master bedroom to zone 002, and so on. Thesenumbers will appear on the display, along with an alphadescriptor for that zone (if programmed), when an alarm or troublecondition occurs.

Page 4: Ademco V120 User Manual

– 4 –

SYSTEM OVERVIEWFire Protection The fire protection portion of your security system (if used) is

always on and will sound an alarm if a fire condition is detected.Refer to the FIRE ALARM SYSTEM section for importantinformation concerning fire protection, smoke detectors andplanning emergency exit routes from your house.

BurglaryProtection

The burglary protection portion of your system must be turned onor "armed" before it will sense burglary alarm conditions. Yoursystem provides four modes of burglary protection: STAY,AWAY, INSTANT and MAXIMUM, and even allows you toBYPASS selected zones of protection while leaving the rest ofthe system armed. The system also provides a CHIME mode, foralerting users to the opening and closing of doors and windowswhile the system is disarmed. Refer to the other sections of thismanual for procedures for using these features.The following table lists the four different arming modes and theresults of each.

Arming Features For Each Arming ModeMode Exit Entry Perimeter Interior

Delay Delay Armed ArmedAWAY Yes Yes Yes YesSTAY Yes Yes Yes NoINSTANT Yes No Yes NoMAXIMUM Yes No Yes Yes

Alarms When an alarm occurs, both the keypad and external sounderswill sound, and the keypad will display the first zone causing thealarm. If your system is connected to a central monitoring station,an alarm message will also be sent. To stop the alarm sounding,simply disarm the system.

Memory of Alarm When an alarm condition occurs, the keypad displays the numberof the first zone that caused the problem, and displays the typeof alarm (ex. FIRE, ALARM). To view any other zones thatsensed an alarm during the same incident, press the ✴ key. Thedisplay will cycle through these zones once, stopping again onthe first zone to sense the alarm. The display remains until it iscleared by disarming the system (see DISARMING THESYSTEM section).

Page 5: Ademco V120 User Manual

– 5 –

SYSTEM OVERVIEWSpeed Keys

(Macros)The system can store 4 strings of up to 32 keystrokes perpartition, which can be activated anytime by simply pressing the"A" , "B", "C", or "D" key. This feature can be used to make iteasy to perform a complicated procedure (such as going toanother partition to bypass a zone), or it can be used to simplifyan everyday, repeated procedure. Refer to the SPEED KEYSsection for procedures for using this feature.

Using Schedules Your system may have been programmed with schedules forautomatically arming, disarming and activating various devicesand/or performing other system functions at predetermined times.Users can modify some of these schedules by manually delayinga closing time, using temporary schedules, or by programmingspecial user schedules. Refer to the USING SCHEDULESsection for scheduling related procedures.

Device Timers The system provides up to 20 "timers" which can be used tocontrol various devices, such as lights or appliances. Thesetimers are similar in concept to the individual appliance timers thatmight be purchased at a department store. The devices that canbe controlled are programmed into the system by the installer.Up to 16 of these devices can be programmed. Refer to thePROGRAMMING DEVICE TIMERS section for procedures.

To AccessAnother Partition(GOTO Command)

Each keypad is assigned a default partition for display purposes,and will show only that partition's information. But, if the user isauthorised, a keypad in one partition can be used to performsystem functions in another partition by using the G O T Ocommand. Note that only those partitions authorised andprogrammed by the installer can be accessed in this manner.To GOTO another partition, enter your security code, then press✱ followed by the desired partition number (1-8).

The keypad will remain in the new partition until directed to go toanother partition, or until 120 seconds has elapsed with nokeypad activity. Entering partition number 0 will return the keypadto its original partition.

Page 6: Ademco V120 User Manual

– 6 –

SYSTEM OVERVIEWMaster Keypad

OperationA "Master" keypad is one on which the status of all 8 partitions isdisplayed simultaneously. A user can get more information abouta certain partition by simply entering ✱ + the desired partitionnumber (1-8). To log on to the "Master" partition (9) using theGOTO command, a user must have access to all partitions.

Self-Help Feature Abbreviated user's instructions are built into the system that canbe easily viewed on the alpha keypad's message displayscreen. This feature will prove particularly useful if this manual isnot conveniently accessible when you need to perform a systemprocedure with which you are not familiar.

To view the abbreviated instructions:Simply press and hold down the function key of interest untilthe description starts to appear (about 5 seconds) and thenrelease it.

Refer to the FUNCTIONS OF THE KEYPAD section fordescriptions of each key function.

Phone Access &Voice Response

Capability

Your system may include a 4285 VIP module that will permit youto access the system via a Touch-tone phone, either on-premises or by call-in when away. The phone access feature willenable you to do the following:

• Receive synthesized voice messages over the telephoneregarding the status of the security system.

• Arm and disarm the system and perform most functioncommands via the telephone, with voice confirmation providedafter each command entry.

• Control 4204 relays/Powerline Carrier devices through the #70Manual Relay Activation mode.

Complete information regarding the use of this feature is providedin a separate manual entitled PHONE ACCESS USER'SGUIDE, which accompanies the 4285 VIP module.

Page 7: Ademco V120 User Manual

– 7 –

FUNCTIONS OF THE KEYPADSGeneral

IMPORTANT: If thekeypad beeps rapidly

upon entering thepremises, it indicates

that an alarm hasoccurred during your

absence. LEAVEIMMEDIATELY and

CONTACT THE POLICEfrom a nearby safe

location.

Your keypads allow you to control all system functions. Thekeypads feature a telephone style (digital) keypad and a 2-line,32 character, alphanumeric Liquid Crystal Display (LCD) whichshows the nature and location of all occurrences. These keypadscan display system messages in the local language. Abbreviateduser's instructions can also be displayed (see Self Helpparagraph in the SYSTEM OVERVIEW section). These keypadscan also be programmed with custom zone descriptors. Keypaddisplay back lighting is programmable to always stay on or tolight only when a key is pressed, then turn off a few minuteslater.

The keypads also feature a built-in sounder which will soundduring alarms and troubles. It will also "beep" during certainsystem functions, such as during entry/exit delay times, duringCHIME mode, and when depressing keys to arm and disarm thesystem (to acknowledge the key press). These sounds can beoptionally suppressed in some of your keypads (so as not todisturb other users of the system). Ask your installer if this hasbeen done.

Page 8: Ademco V120 User Manual

– 8 –

FUNCTIONS OF THE KEYPAD

1. ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD).Displays protection point identification andsystem status, messages, and userinstructions.

2. OFF KEY: Disarms the burglary portion ofthe system, silences alarms and audibletrouble indicators, and clears visual alarmtrouble after the problem has been corrected.

3. AWAY KEY: Completely arms bothperimeter and interior burglary protection bysensing an intruder's movements throughprotected interior areas as well as guardingprotected doors, windows, etc. Late arrivalscan enter through an entry delay zone withoutcausing an alarm if the system is disarmedbefore the entry delay time expires.

4. STAY KEY: Arms the perimeter burglaryprotection, guarding protected doors, windowsand other perimeter protection points, andsounds an alarm if one is opened. Interiorprotection is not armed, which allowsmovement within your house without causingan alarm. Late arrivals can enter through anentry delay zone without causing an alarm ifthe system is disarmed before the entry delaytime expires.

5. MAXIMUM KEY: Arms in manner similarto AWAY mode, but eliminates the entry delayperiod, thus providing maximum protection. Analarm will occur immediately upon opening anyprotection point, including entry delay zones.

6. TEST KEY: Tests the system and alarmsounder if disarmed.

7. BYPASS KEY: Removes indiv idualprotection zones from being monitored by thesystem. Displays previously bypassedprotection zones.

8. INSTANT KEY: Arms in manner similar toSTAY mode, but turns off the entry delayperiod, offering greater security while insideand not expecting any late arrivals. An alarmwill occur immediately upon opening anyperimeter protection point, including entrydelay zones.

9. CODE KEY: Allows the entry of additionaluser codes that can be given to other users ofthe system.

10. CHIME KEY: Turns on & off the CHIMEmode. When on, any entry through a protecteddelay or perimeter zone while the system isdisarmed will cause a tone to sound at theKeypad(s).

11. READY KEY: When depressed prior toarming the system, the keypad will display allopen protection zones within the keypad'shome partition. This key is also used to displayall zone descriptors that have beenprogrammed for your system, by holding thekey down for at least 5 seconds.

12. # KEY: Permits ARMING of the systemwithout use of a security code ("Quick Arm", ifprogrammed).

13. KEYS 0-9: Used to enter your individualsecurity access code(s).

14. READY INDICATOR: (GREEN) Litindicates that no zones are open, while unlitindicates one or more zones are open.

15. ARMED INDICATOR: (RED) Lit when thesystem has been armed (STAY, AWAY,INSTANT or MAXIMUM).

16. INTERNAL SOUNDER: Source of audibleinternal warning and confirmation sounds, aswell as alarms (see "Summary of AudibleNotifications").

17. A-B-C PANIC KEYS: Refer to the PANICKEYS section for descriptions of these keys.

Page 9: Ademco V120 User Manual

– 9 –

1 2 3A

4 5 6B

7 8 9C

* 0 #D

OFF AWAY STAY

MAX TEST BYPASS

INSTANT CODE CHIME

READY

READYARMED

PANIC

A

B

C

D

OFF AWAY STAY

MAX TEST BYPASS

INSTANT CODE CHIME

READY

1 2 3

654

8 97

0* #

1 5 2 3

4

10

9

7

6

11 13

12

8

17

16

14

15

LOCATION OF DEDICATED PANIC KEYS.KEY A, B, C, or D USED AS SPEED KEY (if programmed)

IMPORTANT!: When using the keypad to enter codes and commands,sequential key depressions must be made within 3 seconds of oneanother. If 3 seconds elapses without a key depression, the entry isaborted and must be repeated from its beginning.

Page 10: Ademco V120 User Manual

– 10 –

ENTRY/EXIT DELAYSGeneral

InformationYour system has preset time delays, known as exit delay andentry delay. Whenever you arm your system, exit delay givesyou time to leave through the designated exit door without settingoff an alarm. Exit delay begins immediately after entering anyarming command, and applies to all modes of arming protection. Ifprogrammed, a slow beeping will sound throughout the exit delayperiod, becoming more rapid during the last 5 seconds of thedelay period.

Entry Delay gives you time to disarm the system when youreenter through the designated entrance door. But the systemmust be disarmed before the entry delay period ends, or an alarmwill occur. The keypad will beep during the entry delay period,reminding you to disarm the system. You can also arm the systemwith no entry delay at all by using either INSTANT or MAXIMUMarming modes. These modes provide greater security while onthe premises or while away for extended periods of time. Seeyour installer for your delay times.

DISPLAYING ALL

ZONE DESCRIPTORSUsing the ✱

READY Key

The Alpha Keypads can also display all the zone descriptors thatare programmed in your system. The abbreviated instructions forthe R E A D Y key will appear first, followed by the zonedescriptors. Displaying all descriptors is useful when you need toknow the zone number of a particular zone, as when bypassingzones.

The "Disarmed-Ready to arm" message must be displayedbefore zone descriptors can be displayed.

READY

Press the ✱ key and hold down for at least 5 seconds.

Page 11: Ademco V120 User Manual

– 11 –

CHECKING FOR OPEN ZONESUsing the ✱

READY Key

Before arming your system, all protected doors, windows andother protection zones should be closed or bypassed (seeBYPASSING section). Otherwise the keypad will display a "NotReady" message. Using the READY key will display all zonesthat are faulted, making it easier for you to secure any openzones.Note that your installer can set up your system to allow you toarm the system even though an exit route i s faulted at the timeof arming. The exit route must be closed by the time the exitdelay expires, or the system will go into alarm.

The installer can also program your system to NOT go into alarmif an exit route is still open at the end of the normal exit delay time,but instead will automatically bypass the faulted zone and armthe rest of the system. This may prevent false alarms when people are slow to close an exit route door(s).Check with your installer to determine the options programmed inyour system.To show faulted zones:

DISARMED - PRESS✴ TO SHOW FAULTS

Note: Keypads also light a green LED if allprotection zones are secure. If not lit, thesystem can only be armed if the zones thatare NOT READY are on the exit route.Otherwise, zones that are NOT READY mustbe made secure or bypassed.

READY

1. Do not enter security code, but simply press ✱ key.

FAULT 005 FRONTUPSTAIRS BEDROOM Typical fault display

2. DISARMEDREADY TO ARM

The "Ready" message will be displayed†

when all protection zones have beeneither closed or bypassed.

† NOTE: All or part of this message may bereplaced by a customised messageprogrammed by the installer. Bear this in mindwhenever the instructions indicate that the

"DISARMED" or "READY" message will bedisplayed.

Page 12: Ademco V120 User Manual

– 12 –

BYPASSING ZONESUsing the 6

BYPASS KeyThis key is used when you want to arm your system with one ormore zones intentionally unprotected. Bypassed zones areunprotected and will not cause an alarm when violated while yoursystem is armed. All bypasses are removed when an OFFsequence (security code plus OFF) is performed. Bypasses arealso removed if the arming procedure that follows the bypasscommand is not successful.

To Bypass aZone:

1. Enter the security code. Then press BYPASS [6] and enterthe 3-digit number(s) of zone to be bypassed (ex. 005 forzone 5).

2. BYPASS 007 FRONTUPSTAIRS BEDROOM

Typical bypassmessage

All bypassed zones wil l besequentially displayed when you arefinished entering the number of zonesto be bypassed. The console will thendisplay a bypass message as areminder that one or more zones isbypassed.

3. DISARMED BYPASSREADY TO ARM

Arm the system as usual when thekeypad displays the "ready" to armmessage. Bypassed zones areunprotected and will not cause an alarmwhen violated while your system isarmed.

Notes: 1. All system zone bypasses are removed when anOFF sequence (security code + OFF) is performed.

2. An option can be provided by your installationcompany that will allow zones to be bypassedwhen the system is armed. Bypass(es) can thenbe removed while the system or partition remainsarmed by repeating the same command sequenceused to bypass the zone(s).

Page 13: Ademco V120 User Manual

– 13 –

BYPASSING ZONES

Quick Bypass: Your system allows you to easily bypass all open (faulted)zones without having to enter zone numbers individually.

Note: All bypasses are removed when an OFF sequence(security code + OFF) is performed.

To use the Quick Bypass feature:BYPASS

1. Enter your security code and press 6 then press # .

2. All bypassed zones will be sequentially displayed as whenbypassing individual zones (described previously).

DisplayingBypassed Zones

Used to determine what zones have been previously bypassed.Bypassed zones can be displayed only when system isdisarmed.

BYPASS

1. Enter your security code and press 6 .

2. Wait for all bypassed zones to be sequentially displayed.

Page 14: Ademco V120 User Manual

– 14 –

ARMING PERIMETER ONLY(With Entry Delay ON)

Using the 3STAY key

Use this key when you are staying home, but might expectsomeone to use the entrance door later.

When armed in STAY mode, the system will sound an alarm if aprotected door or window is opened, but you may otherwisemove freely throughout the premises. Late arrivals can enterthrough the entrance door without causing an alarm, but theymust disarm the system within the entry delay period or an alarmwill occur.

Close all perimeter windows and doors before arming (seeCHECKING FOR OPEN ZONES section)

STAY

1. Enter your security code and press 3 .

2. ARMED ***STAY***ZONE BYPASSED

The keypad will beep three times and willdisplay the armed message.

Note: "ZONE BYPASSED" in this displaysimply indicates that the interior zones ofprotection are not armed when usingSTAY mode.

NOTE: Failure to close an open exit route zone before the exitdelay time ends may result in that zone being automaticallybypassed or in alarm, as a function of how your system wasprogrammed by the installer. Consult your installer for theconfiguration of your system.

Page 15: Ademco V120 User Manual

– 15 –

ARMING PERIMETER ONLY(With Entry Delay OFF)

Using the7 INSTANT Key

Use this key when you are staying home and do not expectanyone to use the entrance door.

When armed in INSTANT mode, the system will sound an alarm ifa protected door or window is opened, but you may otherwisemove freely throughout the premises. The alarm will also soundimmediately if anyone opens the entrance door.

Close all perimeter windows and doors before arming (seeCHECKING FOR OPEN ZONES section)

INSTANT

1. Enter your security code and press 7 .

2. ARMED *INSTANT*ZONE BYPASSED

The keypad will beep three times and willdisplay the armed message.

Note: "ZONE BYPASSED" in this displaysimply indicates that the interior zones ofprotection are not armed when usingSTAY mode.

NOTE: Failure to close an open exit route zone before the exitdelay time ends may result in that zone being automaticallybypassed or in alarm, as a function of how your system wasprogrammed by the installer. Consult your installer for theconfiguration of your system.

Page 16: Ademco V120 User Manual

– 16 –

ARMING ALL PROTECTION(With Entry Delay ON)

Using the2 AWAY Key

Use this key when no one will be staying on the premises.

When armed in AWAY mode, the system will sound an alarm if aprotected door or window is opened, or if any movement isdetected inside the premises. You may leave through theentrance door during the exit delay period without causing analarm. You may also reenter through the entrance door, but mustdisarm the system within the entry delay period or an alarm willoccur.

Close all perimeter windows and doors before arming (seeCHECKING FOR OPEN ZONES section)

AWAY

1. Enter your security code and press 2 .

2. ARMED **AWAY**YOU MAY EXIT NOW

The keypad will beep twice and will displaythe armed message.

Note: The "YOU MAY EXIT NOW" portionof the message disappears when exitdelay expires.

NOTE: Failure to close an open exit route zone before the exitdelay time ends may result in that zone being automaticallybypassed or in alarm, as a function of how your system wasprogrammed by the installer. Consult your installer for theconfiguration of your system.

Page 17: Ademco V120 User Manual

– 17 –

ARMING ALL PROTECTION(With Entry Delay OFF)

Using the4 MAXIMUM Key

Use this key when the premises will be vacant for extendedperiods of time such as vacations, etc., or when no one will bemoving through protected interior areas.

When armed in MAXIMUM mode, the system will sound an alarmif a protected door or window is opened, or if any movement isdetected inside the premises. You may leave through theentrance door during the exit delay period without causing analarm, but an alarm will be sounded as soon as someonereenters.

Close all perimeter windows and doors before arming (seeCHECKING FOR OPEN ZONES section)

MAXIMUM

1. Enter your security code and press 4 .

2. ARMED *MAXIMUM*YOU MAY EXIT NOW

The keypad will beep twice and will displaythe armed message.

Note: The "YOU MAY EXIT NOW" portionof the message disappears when exitdelay expires.

NOTE: Failure to close an open exit route zone before the exitdelay time ends may result in that zone being automaticallybypassed or in alarm, as a function of how your system wasprogrammed by the installer. Consult your installer for theconfiguration of your system.

Page 18: Ademco V120 User Manual

– 18 –

DISARMING

AND SILENCING ALARMSUsing the

1 OFF KeyThe OFF key is used to disarm the system and to silence alarmand trouble sounds. See "SUMMARY OF AUDIBLENOTIFICATION" section for information which will help you todistinguish between FIRE and BURGLARY alarm sounds.

IMPORTANT: If you return and the main burglary sounder is on,DO NOT enter the premises, but call the police from a nearbysafe location. If you return after an alarm has occurred and themain sounder has shut itself off, the keypad will beep rapidlyupon entering, indicating that an alarm has occurred during yourabsence. LEAVE IMMEDIATELY and CONTACT THE POLICEfrom a nearby safe location.

To disarm the system and silence burglary or fire alarms:OFF

1. Enter your security code and press 1 .

DISARMEDREADY TO ARM

2. The Ready message will be displayed (if no alarms haveoccurred while armed) and the keypad will beep once toconfirm that the system is disarmed.

Memory of Alarm The keypad displays the zone number and type of alarm for anyzone that has an alarm condition. These messages will remaindisplayed until cleared by a user. If an alarm has occurred, notethe zone number displayed on the keypad and repeat step 1above to clear the "Memory of Alarm" and restore the Readymessage display. If the Ready message will not display, go tothe displayed zone and remedy the fault (close windows, etc.). Ifthe fault cannot be remedied, notify the alarm agency.

If the system was armed when the alarm occurred, repeat step 1twice: once to disarm the system, a second time to clear thedisplay.

Page 19: Ademco V120 User Manual

– 19 –

USING KEYSWITCHESGeneral Your system may be equipped with a spring loaded keyswitch

for use when arming and disarming. A red and green light on thekeyswitch plate indicate the status of your system as follows:

Green Light: Lights when the system is disarmed andready to be armed (no open zones). If thesystem is disarmed and the green light is off, itindicates the system is not ready (one or morezones are open).

Red Light: Lights when system is armed or memory ofalarm exists.

Lit Steady: System is armed in AWAY mode.

Slow Flashing: System is armed in STAY mode.

Rapid Flashing: Memory of alarm; an alarm has occurred .Arming To arm in the AWAY

mode, turn the key to theright for 1/2 second andrelease. Keypads will beeptwice and the red light willstay on steady.

To arm in the STAYmode, turn the key to theright and hold for longer than3 seconds, then release.Keypads will beep threetimes and the red light willflash slowly.

GREEN RED

Disarming To disarm the system, turn the key to the right and release. Ifan alarm has occurred, the red light will be flashing rapidly(memory of alarm).

OtherKeyswitches

Other keyswitches may be fitted on a partition by partition basis.These keyswitches do not use spring loaded key locks. A key isinserted at an OFF position and turned to an AWAY positionwhere the key is removed. Disarming is achieved by inserting thekey and returning the lock to its original vertical position. Thesekeyswitches may or may not be used with status LEDs toindicate partition status.

Page 20: Ademco V120 User Manual

– 20 –

CHIME MODEUsing the 9 Key Your system can be set to alert you to the opening of a door or

window while it is disarmed by using CHIME mode. Whenactivated, three tones will sound at the Keypad whenever aprotected perimeter door or window is opened, and the NotReady message will be displayed. Pressing the READY keywill display the open protection points.Note that Chime mode can be activated only when the system isdisarmed.

1. To turn Chime Mode on, enter the security code and press 9 .

CHIME MODE ON The CHIME MODE ON message willappear for about two seconds thendisappear. To display this message again(to determine whether chime mode is onor off), simply press and hold down theCHIME key for 5 seconds.

2. To turn Chime Mode off, enter the security code and press 9 again.

CHIME MODE OFF The CHIME MODE OFF message willappear for about two seconds thendisappear. To display this message again(to determine whether chime mode is onor off), simply press and hold down theCHIME key for 5 seconds.

Page 21: Ademco V120 User Manual

– 21 –

ACCESS DOOR CONTROLGeneral

InformationYour system may be set up such that a locked access door (suchas in a lobby) can be unlocked using a keypad command. Askyour installer if this has been done in your system.

There are four access door commands as follows:

1. Quick UnlockEnter your security code and press 0 . The door will unlockfor 2 seconds.

2. Timed Unlock of Assigned DoorEnter your security code + [#] 73. The door will unlock for theperiod of time programmed by the installer (using the ACSsoftware).

3. Timed Unlock of User Selected DoorEnter your security code + [#] + 74. A prompt will display forthe specific access point to be unlocked and whether it is anentry or exit door. The selected door will unlock for a specificperiod of time programmed by the installer (using the ACSsoftware).

4. Unlock of User Selected Door with Selected FunctionEnter your security code +[#] + 75. A prompt will display forthe specific access point to be unlocked and a desiredfunction: 1-Grant, 2-Protect, 3-Bypass. "Grant" temporarilyunlocks the door to allow access. "Protect" causes the door tounlock only when a valid access is received. "Bypass"permanently unlocks the door to allow continuous access.

Page 22: Ademco V120 User Manual

– 22 –

PANIC KEYS(FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE

ALARMS)Using

Panic KeysYour system may have been programmed to use special keycombinations to manually activate panic functions. The functionsthat might be programmed are Silent Emergency, AudibleEmergency, Personal Emergency, and Fire. See your installer forthe function(s) that may have been programmed for your system.

Active Panic Functions(your installer should note which

function(s) is active in your system)Keys Zone Function1 and ✱ 9953 and # 996✱ and # 999

A* 995B* 999C* 996

* May be assigned to Speed Key Functions.

To use a paired keypanic function, simplypress both keys of theassigned pair at thesame time. If yourkeypad(s) have letteredkeys for panic functions,press the designatedkey and hold down for atleast 2 seconds toactivate the panicfunction.

A silent emergency sends a silent alarm signal to the centralstation, but there will be no audible alarms or visual displays.

An audible emergency sends an emergency message to thecentral station (if connected) and will sound a loud, steady alarmat your keypad and at any external sounders that may beconnected (ALARM plus a zone number would also bedisplayed).

A personal emergency alarm sends an emergency message tothe central station (if connected) and will sound at Keypads, butnot at external bells or sirens. (ALARM plus a zone numberwould also be displayed)

A fire alarm sends a fire alarm message to the central station andwill uniquely sound external bells and sirens (FIRE plus a zonenumber would also be displayed).

Page 23: Ademco V120 User Manual

– 23 –

SPEED KEYS (MACROS)General

InformationThe "A", "B", "C", and/or "D" key can each be used to activate astring of commands up to 32 keystrokes (depending on installerprogramming). These commands are known as a macro and arestored in the system's memory. Typical Speed Key functionsinclude:

• Seldom used but repeatable sequences.• Arming sequences that involve first bypassing certain zones

before arming.• Relay activation sequences.

Defining Enter your user code + [#] + [x] (where x is the A, B, C or D key)and hold the [x] key down until the following appears:

ENTER SPEED KEY "D"existing sequence displayed

Enter up to 32 keystrokes. A speed keysequence can include differentcommands. Press the "D" key toseparate different commands.

For example, you may want to perform the following sequence.GOTO partition 2................... Enter *2Bypass zones 010 & 011...... Press bypass [6], then the zone

numbers 10 & 11Arm in maximum mode............. Press maximum [4] keyReturn to partition 1 ................ Enter *1

To program this sequence, type the following :

*2 D 6010011 D 4 D *1 D D

Note that the "D" key is pressed after the "2," the last "1" and the"4," separating the different commands. Press "D" twice tocomplete the entry and exit.

NOTE: When defining speed key sequences, do not use the [#] keyto represent Quick Arming. The system uses the code entered at theprompt to initiate commands in a speed key sequence. The systeminterprets the use of the [#] key in a speed key sequence as itsdesignated function only.

Executing Press and hold down the appropriate lettered key (about 2 seconds)until the following prompt appears:

ENTER USER CODE✴✴✴✴

Enter your user code. The definedspeed key sequence will beginautomatically.

Page 24: Ademco V120 User Manual

– 24 –

USING #70 RELAY MENU MODEGeneral

InformationYour system may be set up so that certain lights or other devicescan be turned on or off by using the #70 command from either akeypad or a telephone keypad (if 4285 VIP module is used). Askyour installer if this has been done in your system.To activate relays from a keypad, enter 4-digit security code +[#] +70. Follow the keypad prompts described below.To activate relays using a telephone and 4285 VIP module,first dial the 2-digit phone access code. When the systemacknowledges the access, enter 4-digit security code + [#] + 70.The following prompts/voice responses will begin.

ENTER DEVICE NO.00=QUIT 01

Voice: "ENTER DEVICE CODE NOW"

Enter the 2-digit number of the device to beactivated.Note that if an invalid number is entered, thesystem will simply ask you to reenter thenumber.

NN DEVICE IS OFFHIT 0=OFF , 1=ON

Voice: "voice descriptor DEVICE nn ON/OFF.FOR voice descriptor ON ENTER 1, FOR voicedescriptor OFF ENTER 0"

Press 0 or 1 to turn the device off or onrespectively."nn" represents the 2-digit device numberand voice descriptor is the relay voicedescriptor programmed by the installer.

NN DEVICE IS OFFHIT THE "✴" KEY

Voice: "voice descriptor DEVICE nn ON/OFF. TOEXIT ENTER 00 NOW"

From a keypad, press ✴ to continue. TheENTER DEVICE NO. prompt will appear.From a telephone keypad, enter 00 toexit, or enter the next relay number to beprogrammed. The current on/off state of thatrelay will be annunciated as describedabove. Alternatively, if 6 seconds elapseswith no key depression, the 4285 VIPmodule will annunciate the "ENTER DEVICECODE NOW" message.

Page 25: Ademco V120 User Manual

– 25 –

VIEWING CENTRAL STATION

MESSAGESGeneral

InformationUsers of the system may periodically receive messages on theirdisplay screens from their monitoring agency or installer. When amessage is waiting to be viewed, the message shown below willappear.

MESSAGE. PRESS 0FOR 5 SECS.

1. Press and hold down 0 key for 5 seconds.

2. The message could take up to four screens to display all theinformation available.

Page 26: Ademco V120 User Manual

– 26 –

SECURITY CODES

& AUTHORITY LEVELSGeneral

InformationAt the time of installation, you were assigned an authority leveland a personal four-digit security code, known only to you andyours. The security code must be entered when arming anddisarming the system. The authority level defines the systemfunctions that you can perform.

As an additional safety feature, other users that do not have aneed to know your code can be assigned different securitycodes, and each user can be given a different authority level.Users are identified by "user numbers", which are assigned whenassigning a user's security code.

All codes can be used interchangeably when performing systemfunctions within the limits of each code's authority level (a systemarmed with one user's code can be disarmed by another user'scode), with the exception of the Operator Level C code. SeeAUTHORITY LEVELS section on the following page for detailedinformation regarding user authority levels.

If more than 20 key presses are made within a 15 minute periodwithout entering a valid command sequence, the system willignore all subsequent key presses for the next 15 minutes.

Duress Code This feature is intended for use when you are forced to disarm orarm the system under threat. When used, the system will actnormally, but can silently notify the central station of yoursituation, if that service has been provided. The duress code ispre-assigned by the installer during installation (auth. level 6).

Important: This code is useful only when the system isconnected to a central station.

Quick Arming Note that if "Quick Arming" was programmed by the installer, the# key can be pressed in place of the security code when arming

the system. The security code must always be used to disarmthe system, however.

Page 27: Ademco V120 User Manual

– 27 –

SECURITY CODES

& AUTHORITY LEVELSAuthority Levels Authority levels define the system functions a particular user can

perform. Depending on the authority assigned to you, there arecertain system functions you may be prohibited from performing.In summary, there are six authority levels, each having certainsystem restrictions as shown below.

Level 1 Master: Can perform all system functions in assignedpartitions, and can add, delete, or changeManager and Operator users. Master codesare added by the Installer.

Level 2 Manager: Can perform system functions in assignedpartitions, and can add, delete, or changeOperator level users.

Level 3 Operator A: Can perform system functions in assignedpartitions, but cannot add or delete otherusers.

Level 4 Operator B: Same as Operator A, except Operator Bcannot bypass zones of protection.

Level 5 Operator C: Can arm the system in assigned partitions, butcannot disarm the system unless the systemwas armed with this code. This code is typicallyassigned to someone who has the need toarm/disarm the system only at certain times(such as a baby-sitter).

Level 6 Duress: Can arm and disarm the system, but alsosends a silent panic alarm to the centralstation, if that service is connected.

To view your authority level and system capabilities:1. Enter your code + ✱ + ✱ .2. The keypad will display the partition(s) that you are

authorised to operate, and your user number and authoritylevel in each partition.

Page 28: Ademco V120 User Manual

– 28 –

SECURITY CODES

& AUTHORITY LEVELSGeneral Rules onAuthority Levels

and Changes

• A user may not delete or change the user code of the SAME orHIGHER authority than which he is assigned.

• A user may only ADD users to a LOWER authority level.• A user may assign access codes only to those partitions to

which the user adding the code has access. (ex. a user withaccess to only partition 1 cannot assign codes in partition 2.)

• The only way to assign a user's authority level is by using the"Add A User" procedure. To change a user's authority level,that user must first be deleted, then added again.

• A user can only be DELETED or CHANGED from within thepartition he is assigned.

• User numbers must be entered as 3-digit entries. single digituser numbers must be preceded by two zeros (example, 003,004, etc.). Security codes are entered as 4-digit numbers.

• Before assigning a security code, be sure it does not conflictwith any DURESS code.

Note: When adding, changing or deleting users, all other alphakeypads in that partition will display "User Edit Mode – PleaseStand By", and key depressions (except Panic) at thosekeypads will be ignored. Panic key depressions will cause analarm and terminate user entry.

To Exit User EditMode

You can exit any of the user edit modes described on thefollowing pages at any time by doing the following:

1. Press either ✱ or # , or don't press any key for 10 seconds.

2. System returns to normal mode.

Page 29: Ademco V120 User Manual

– 29 –

SECURITY CODES

& AUTHORITY LEVELSTo Add a User IMPORTANT: Temporary users should not be shown how to

use any system function they do not need to know (e.g.bypassing protection zones).

CODE

1. Enter Master or Manager code and press the 8 key.

2. Enter the new user's 3-digit User Number (002-150).

3. Enter 4-digit security code for that user. The following promptswill appear.

ADD NEW USER?0 = NO , 1 = YES

Enter 1 to add a new user code. Entering0 will change the existing user's code tothe code entered in step 3. See ChangingA User's Code section.

USER NUMBER = 003ENTER AUTH.LEVEL

Enter the authority level, 1-6, for this userwithin this partition.

1=master 4=operator B2=manager 5=operator C3=operator A 6=duress code

ACCESS GROUP?ENTER 0-8

This prompt will appear if accessschedules havbe been programmed.Enter the user's access group number (1-8) if this user should have limited access tothe system. Enter 0 if no access groupshould be assigned.

RF BUTTON ?0 = NO , 1 = YES

This prompt will appear if a 5800 seriesbutton transmitter has been supplied andhas not yet been assigned to a user. Press1 if a button transmitter will be assigned tothis user. Otherwise press 0.

ENTER BUTTON ZN #(001-128)

If assigning a button transmitter, thisprompt will appear. Enter the button'szone number (see your installer for zonenumber).

Page 30: Ademco V120 User Manual

– 30 –

SECURITY CODES

& AUTHORITY LEVELSTo Add a User

(continued)MULTI-ACCESS ?0 = NO , 1 = YES

If you as a user have access to otherpartitions, the keypad will prompt for abilityof this new user to access (GOTO) thosepartitions. Press 0 (NO) or 1 (YES). If no,the system activates this user code andexits “Add a User” mode. If yes, thekeypad prompts for the Global Arm optionfor this user.

GLOBAL ARM ?0 = NO , 1 = YES

Press 1 (YES) if this user will be allowed totry to arm more than one partition at thesame time. Press 0 if this user will arm onlyhis assigned partition.

PART.2 - SHOP?0 = NO , 1 = YES

The keypad now prompts for the user’saccess to the next partition (see GOTOcommand). Again press 0 or 1. If yes, thesystem will automatically assign a usernumber for use in that partition and willprompt for the authority level and globalarm option for this user within the partition(see previous steps).

PART. 1 ✴ WHSEUSER 003 AUTH=3G.

When all partitions have been displayed,the keypad will scroll through thepartition(s) to which access has beenassigned, and will display the usernumber, authority level and global armoption for each. The “G” after the authoritylevel indicates that the global arm feature isactive for this user in the displayedpartition. The "✴" indicates the partitionfrom which this user can be changed ordeleted. The "." at the end of the secondline indicates that this user sendsopen/close reports. Open/close reportingis automatically active for any users addedby you, if you have open/close reportingactive.

Page 31: Ademco V120 User Manual

– 31 –

SECURITY CODES

& AUTHORITY LEVELSTo Change aUser's Code

CODE

1. Enter Master or Manager code and press the 8 key + usernumber to be changed.

2. Enter the new code for that user.

ADD NEW USER?0 = NO , 1 = YES

The system will recognize that the usernumber is already in use and will promptwhether or not this is a new user. Enter 0 tochange the existing user's code to the codeentered in step 3.

USER 002 CHANGEDSUCCESSFULLY

The system will confirm that the change isallowed based on authorization level, andif so, will put the new code into effect.

Note that if changing one’s owncode, the system will prompt for the newcode to be reentered. This preventsaccidentally changing one's own code.

To Delete a UserCODE

1. Enter Master or Manager code and press the 8 key + UserNumber to be deleted.

2. Enter Master or Manager code first entered.

OK TO DELETE0 = NO , 1 = YES

The system will recognize that the Usernumber is already in use and will prompt toconfirm that it should be deleted. Press 0(NO) or 1 (YES).

USER CODEDELETED

If yes, that user's code will be removed fromall partitions to which it was assigned, and allauthorization levels and other informationabout that user will be deleted. Note that auser can only be deleted from the partition inwhich it was first assigned, and can only bedeleted by a user with a higher authoritylevel. A User's security code cannot bedeleted by oneself.

Page 32: Ademco V120 User Manual

– 32 –

ACCESSING OTHER PARTITIONS(GOTO Command and Global Arming)

To AccessAnother Partition

Each keypad is assigned a default partition for display purposes,and will show only that partition's information. But, if the user isauthorised, a keypad in one partition can be used to performsystem functions in other partitions by using the G O T Ocommand. Note that only those partitions authorised andprogrammed by the installer can be accessed in this manner.

To GOTO another partition: READY

1. Enter your security code, then press ✱ + partitionnumber (0-9).Entering partition number 0 will return the keypad to its originalpartition.

2. LOG-ON TO AAAAPART. X COMPLETE

The keypad will remain in the new partitionuntil directed to go to another partition, oruntil 2 minutes has elapsed with nokeypad activity.AAAA = alpha descriptor programmed bythe installerX = partition number

Global Arming The Global Arming option may have been programmed for useby some users. If Global Arming was enabled for use with yoursecurity code, a keypad prompt (message) will appear afterpressing one of the arming function keys (STAY, INSTANT,AWAY, MAXIMUM, OFF). Follow the keypad prompts to continuearming the system. See your installer for detailed instructions onthe use of this feature.If global arming does not apply to your security code, use theprocedures described in the following pages.

Master KeypadOperation

A "Master" keypad is one that reflects the status of the entiresystem (Partitions 1-8) on its display. This is useful because iteliminates the need for a security officer in a building to have to"log-on" to various partitions from one partition's keypad to findout where an alarm has occurred.A description of a typical display follows:

S Y S T E M 1 2 3 4 5 6 7 8S T A T U S R R N N A ✴ B

Page 33: Ademco V120 User Manual

– 33 –

ACCESSING OTHER PARTITIONSMaster Keypad

Operation(continued)

The status of each partition is directly below the partition numberon the display. Possible status indications include:

A = Armed Away M = Armed MaximumS = Armed Stay I = Armed InstantR = Ready N = Not ReadyB = Bypassed/Ready ✴ = Alarm Memory/Trouble present

To obtain more information regarding a particular partition, enter ✴+ [Partition No.] (i.e., ✴4). This will allow viewing only of thatpartition. In order to affect that partition, the user must log on witha code that has access to that partition. Also, in order for a userof any partition to log onto the "Master" partition (Partition 9) toview the status of all partitions, that user must have access to allpartitions. Otherwise, access will be denied.The following is an example of what would be displayed for afault condition on Zone 2 (Loading Dock Window) on Partition 1(Warehouse) when logging on from a keypad on Partition 9:

WHSE DISARMEDHIT ✴ FOR FAULTS

This is the normal display that appears at Partition 1's keypad(s).Pressing ✴ will display:

F A U L T 00 2 L O A D I N GD O C K W I NDOW

Additional zone faults will be displayed one at a time. To displaya new partition's status, press ✴ + [Partition No.]. This willdisplay the status of the new partition.The "Armed" LED on a Master keypad will be lit only if allpartitions have been armed successfully. The "Ready" LED willbe lit only if all partitions are "ready to arm."The sounder on a Master keypad will reflect the sound of themost critical condition on all of the partitions. The priority of thesounds is as follows:

A. Pulsing fire alarm soundsB. Steady burglar alarm soundsC. Trouble sounds

The sounder may be silenced by pressing any key on theMaster keypad.

Page 34: Ademco V120 User Manual

– 34 –

ACCESSING OTHER PARTITIONSCommon AreaOperation

When an installation consists of a partition shared by usersof other partitions in a building, that shared partition may beassigned as the "common area" partition for the system. Anexample of this might be in a medical building where thereare two doctor's offices and a common entrance area.This option employs logic for automatic arming anddisarming of the common area. Partitions may be set toaffect and/or attempt to arm the common area. This will affectthe way the common area will react when arming ordisarming activity occurs in another partition.Partitions set to affect the common area will cause thefollowing to occur:

a. When the first partition that affects the common area isdisarmed, the common area will also be disarmed.

b. The common area cannot be armed unless every partitionselected to affect it is armed.

c. Arming the last partition that affects the common area willnot automatically attempt to arm the lobby.

Partitions set to arm the lobby will cause the following tooccur:

a. When the first partition that affects the common area isdisarmed, the common area will also be disarmed.

b. The common area cannot be armed unless every partitionselected to affect the lobby is armed.

c. Arming the last partition that is programmed to arm thecommon area will automatically attempt to arm the commonarea. If any faults exist in the common area partition, oranother partition that affects the common area is disarmed,the common area cannot be armed, and the message"UNABLE TO ARM PART" will be displayed.

The following chart sums up how the common lobby partition will operate.Partition Partition Arms Disarms when Attempts to arm Can be armed ifAffects Common Area partition disarms when partition other partitionsCommon Area arms disarmed

NO NO NO NO YESYES NO YES NO NOYES YES YES YES NONO YES ---ENTRY NOT ALLOWED---

Page 35: Ademco V120 User Manual

– 35 –

ACCESSING OTHER PARTITIONS

How User CodesAffect the CommonArea

Codes with "Global" ArmingIf your code is given "global arming" when it is defined thekeypad will ask "Arm all?" or "Disarm all?" whenever youtry to arm or disarm the partitions you have access to froman alpha keypad. This allows you to pick and choose thepartitions to be armed or disarmed, and so eliminates the"automatic" operation of the common area. Keep in mind,however, that if attempting to arm all, and another "affecting"partition is disarmed, you will not be able to arm the commonarea, and the message "UNABLE TO ARM COMMONAREA PART" will be displayed.

Codes with "Non-Global" ArmingIf arming with a non-global code, or if arming with a globalcode from a non-alpha keypad, the common area partitionoperation will be automatic, as described in the previoustable.

Other Methods of Arming/Disarming

When arming or disarming a partition that affects and/or armsthe common area in one of the following manners, commonarea logic remains active:• Quick-Arm• Keyswitch• Wireless Button• Wireless Keypad

Page 36: Ademco V120 User Manual

– 36 –

USING SCHEDULES

Delaying theClosing Time

Your system's programmed schedules may automatically arm thesystem at a predetermined time. In the event a user must stay onthe premises later than usual, users with master or managerauthority levels can manually delay the automatic arming (closing)time up to 2 hours.To delay the closing time

1. Enter your security code (master or manager authoritylevels only).

2. Press the # key, followed by 82.3. A menu prompt will be displayed, asking for the number of

hours of delay.

CLOSING DELAY?HIT 0-2 HOURS

Enter the desired number of hours ofdelay, 1 or 2. The system willautomatically exit this mode after entry.

Note that the delay is from the scheduled closing time ,not from the time the command is entered.IMPORTANT: The selected delay cannot be reducedonce it is set. A 1 hour delay can be increased to 2 hours,though.

4. The system will automatically send a message to the centralstation informing them that the programmed schedule hasbeen changed.

Page 37: Ademco V120 User Manual

– 37 –

USING SCHEDULES

TemporaryOpen/Close

Schedules

Temporary schedules allow you to override the normal schedulesprogrammed by the installer. Temporary schedules can be ineffect for up to one week, and take effect as soon as they areprogrammed.Schedules are comprised of an arming (closing) time window anda disarming (opening) time window. A time window is simply adefined period of time, at the end of which arming or disarming willoccur.

Before programming a temporary schedule, use a worksheetsimilar to the one below to plan your schedule. This will make iteasier when actually programming the schedule.

Arm/Disarm Mon Tue Wed Thu Fri Sat SunWindowsDisarm Window

Start Time HH:MMStop Time HH:MM

Arm WindowStart Time HH:MMStop Time HH:MM

Page 38: Ademco V120 User Manual

– 38 –

USING SCHEDULESProgramming

TemporarySchedules

Temporary schedules only affect the partition from which it isentered. Temporary schedules can be reused at later datessimply by scrolling (by pressing #) to the DAYS? prompt(described below) and activating the appropriate days. Thisshould be considered when defining daily time windows. Notethat only users with authority level of manager or higher canprogram temporary schedules.

To program temporary schedules:1. Enter your security code.2. Press the # key followed by 81.3. The following prompts will appear.

MON DISARM WIND.07:45AM 08:45AM

The cursor will be positioned on the tensof hours digit of the start time forMonday's disarm window. Enter thedesired hour. Press * to move to theminutes field. The minutes are enteredin the same manner. The AM/PMindication is changed by hitting any key,0-9, while the cursor is under the letterA/P position. Repeat for the stop timeentry. Press the * key to move to thearming window for Monday.Press # to move to the next screendisplay without making changes.

MON ARM WINDOW07:45AM 08:45AM

The cursor will be positioned on the tensof hours digit of the start time for the armwindow. Repeat the previous steps toenter the start and stop time for Monday'sarming window.

Page 39: Ademco V120 User Manual

– 39 –

USING SCHEDULES

ProgrammingTemporarySchedules

(continued)

TUE DISARM WIND.07:45AM 08:45AM

After the windows for that day havebeen completed, the system will promptfor disarm and arm time windows for thenext day. Repeat the procedure for alldays of the week.When all of the days have beencompleted, the system will ask whichdays are to be activated.

DAYS ? MTWTFSS HIT 0-7 X X

This is the prompt that actually activatesthe temporary schedule, and allows thetemporary schedule to be customisd to aparticular week's needs. To select thedays which are to be activated, enter thedesired number 1-7 (Monday = 1). An"X" will appear under that day, indicatingthe previously entered schedule for thatday is active. Entering a day's numberagain will deactivate that day. Pressing 0will turn all days on/off.The temporary schedule will only be ineffect for the days which have the letterx underneath them. As the weekprogresses, the days are reset to thedeactive state.When completed, press * to exit thetemporary schedule entry mode.

Page 40: Ademco V120 User Manual

– 40 –

PROGRAMMING DEVICE TIMERSGeneral

InformationDevice timers consist of an ON time & an OFF time, and selecteddays of the week in which they are active. There are up to 20timers that can be used to control various devices, such as lightsor appliances. Your installer will have programmed theappropriate devices into the system (up to 16 devices can beprogrammed).Each timer controls a single device (designated as an outputnumber) that you select. For example, timer 1 might be set to turnthe porch lights on at 7:00pm and turn them off at 11:00pm. Timer2 might turn on the air conditioner Monday-Friday at 4:30pm tocool the premises before you arrive at 5:00pm, and turn it off at10:00pm when you are retiring for the night. If desired, differenttimers can control the same device. For example, timer 2 could beused Monday-Friday as in the previous example, and timer 3could be set to turn the air conditioner on and off at different timesSaturday and Sunday.

To enter the device timer menu mode:Enter your security code, then press the # key followed by 83.

OUTPUT TIMER # ? 01-20,00=QUIT 01

Up to 20 timers can be programmed. Eachtimer is identified by a number 1-20. Enterthe desired timer number to be programmed(1-20). Press * to accept entry.

06 07:00P 11:45P

PORCH LITE 04

If that timer number has already beenprogrammed, a summary screen will appear.In this example:

06 = Timer #04 = Output Device # affected by this timerPORCH LITE = Output Descriptor for Device 407:00PM = Start Time;11:45PM = Stop Time

Press * to continue.

See your installer fordevice numbers. 00 ENTER OUTPUT#

00

Enter the desired output device number (1-16). As the number is entered, the device'sdescription will appear.

To delete a previously programmed timer,enter 00 as the output number.

Page 41: Ademco V120 User Manual

– 41 –

PROGRAMMING DEVICE TIMERS00 ON TIME ? 00:00 PM

Enter the time you want the device turnedon using 00:01 - 11:59 format. When thedisplay shows the desired time, press the *key to move to the AM/PM field. Press anykey 0-9 to change the AM/PM indication.Enter 00:00 if this timer is not being used toturn something ON for the days selectedbelow. (ex. using one timer to turn lights onone day and using another timer to turnthem off on another day).

00 OFF TIME ? 00:00 PM

Enter the time you want the device turnedoff using 00:01 - 11:59 format. When thedisplay shows the desired time, press the *key to move to the AM/PM field. Press anykey 0-9 to change the AM/PM indication.Enter 00:00 if this timer is not being used toturn something OFF for the days selectedbelow. (ex. using one timer to turn lights onone day and using another timer to turnthem off on another day).

00 DAYS? MTWTFSSHIT 0-7 X X

Select the days on which the device is to beactivated by entering 1-7 (Monday = 1). An"X" will appear under that day, indicating theoutput for that day is active. Entering a day'snumber again will deactivate that day.Pressing 0 will turn all days on/off. Theoutputs will only be in effect for the dayswhich have the letter x underneath them. Asthe week progresses, the selected days arereset to the inactive state, unless thepermanent option is selected (next screenprompt). When completed, press * tocontinue.

00 PERMANENT ? 0 = NO, 1 = YES 0

Answering 1 (yes) means the system willcontinue executing this timer on acontinuous basis. An answer of 0 meansexecute each day's output only once.

Page 42: Ademco V120 User Manual

– 42 –

TESTING THE SYSTEM(TO BE CONDUCTED WEEKLY)

Using the5 TEST Key

Note that no alarmreports will be

sent to the centralmonitoring station

while the systemis in Test mode.

The TEST key puts your system into the Walk Test mode, whichallows each protection point to be checked for proper operation.1. Disarm the system and close all protected windows, doors,

etc. READY should be displayed.TEST

2. Enter your security code and press the 5 key.3. The external sounder should sound for 3 seconds and then

turn off. If the sounder does not sound, it may be due to dialercommunication activity. Wait a few minutes and try again. Ifthe sounder still does not sound, CALL FOR SERVICEIMMEDIATELY.

4. The keypad will sound a single beep every 15 seconds as areminder that the system is in Test mode. Each time aprotection zone is faulted (opened), the keypad should beepthree times. If the sounder does not sound, CALL FORSERVICE IMMEDIATELY.

5. Open and close each protected door and window in turn andlisten for three beeps. The identification of each faultedprotection point should appear on the display.

6. Walk in front of any interior motion detectors (if used) andlisten for three beeps as movement is detected. Theidentification of the detector should appear on the displaywhen it is activated. If a problem is experienced with anyprotection point (no confirming sounds, no display), CALLFOR SERVICE IMMEDIATELY.

7. Follow the manufacturer's instructions to test all smokedetectors to ensure that all are functioning properly. Theidentification of each detector (or the zone number of the zoneassigned to the detector) should appear on the display wheneach is activated.

8. When all protection points have been checked, there shouldbe no zone identification numbers displayed. If a problem isexperienced with any protection point (no confirming sounds,no display), CALL FOR SERVICE IMMEDIATELY.

9. Turn off Test mode by entering the security code andpressing the OFF key.

Page 43: Ademco V120 User Manual

– 43 –

FIRE ALARM SYSTEM(IF INSTALLED)

General Your fire alarm system (if installed) is on 24 hours a day,providing continuous protection. In the event of an emergency,the installed smoke and heat detectors will automatically sendsignals to your Control/Communicator, triggering a loud,interrupted sound from the Keypad. An interrupted sound willalso be produced by optional exterior sounders. A FIRE messagewill appear at your Keypad and remain on until you silence thealarm.

In Case Of FireAlarm

1. Should you become aware of a fire emergency before yourdetectors sense the problem, go to your nearest Keypad andmanually initiate an alarm by pressing the panic key pairassigned as FIRE emergency (if programmed by the installer)and hold down for at least 2 seconds.

2. Evacuate all occupants from the premises.3. If flames and/or smoke are present, leave the premises and

notify your local Fire Department immediately.4. If no flames or smoke are apparent, investigate the cause of

the alarm. The zone descriptor of the zone(s) in an alarmcondition will appear at the Keypad.

Silencing A FireAlarm

1. Silence the alarm by entering your code and pressing theOFF key. To clear the display, enter your code and press theOFF key again.

2. If the Keypad does not indicate a READY condition after thesecond OFF sequence, press the READY key to displaythe zone(s) that are faulted. Be sure to check that smokedetectors are not responding to smoke or heat producingobjects in their vicinity. Should this be the case, eliminate thesource of heat or smoke.

3. If this does not remedy the problem, there may still be smokein the detector. Clear it by fanning the detector for about 30seconds.

4. When the problem has been corrected, clear the display byentering your code and pressing the OFF key.

Page 44: Ademco V120 User Manual

– 44 –

TROUBLE CONDITIONSTypical Trouble

Displays

*Note that zonenumbers 601-632,800-831, 988, 990,& 997 represent

problems which arenot user

serviceable. CALLFOR SERVICEIMMEDIATELY.

**Not all systemsemploy wireless

transmitters.

The word C H E C K or T R B L on the Keypad's display,accompanied by a rapid "beeping" at the Keypad, indicates thatthere is a trouble condition in the system.To silence the beeping sound for "check" conditions, pressany key.

1. A display of "CHECK" or "TRBL" accompanied by adisplay of "CALL SERVICE" indicates that a problem existswith the system that eliminates some of the protection. CALLFOR SERVICE IMMEDIATELY.

2. A display of "CHECK" or "TRBL" accompanied by adisplay of one or more zone descriptors indicates that aproblem exists with those zone(s)*. First, determine if thezone(s) displayed are intact and make them so if they are not.If the problem has been corrected, the display of the zonedescriptor(s) and "CHECK" or "TRBL" should appear. If not,key an OFF sequence (Code plus OFF) to clear the display.If the display persists, CALL FOR SERVICE IMMEDIATELY.

3. A display of "COMM. FAILURE" at the Keypad indicatesthat a failure has occured in the telephone communicationportion of your system. CALL FOR SERVICEIMMEDIATELY.

4. A display of "SYSTEM LO BAT" accompanied by a onceper minute "beeping" at the Keypad indicates that a lowsystem battery condition exists. CALL FOR SERVICEIMMEDIATELY.

5. A display of "LO BAT" and a zone descriptor, accompaniedby a once per minute "beeping" at the Keypad indicates thata low battery condition exists in the wireless transmitter**displayed. CALL FOR SERVICE IMMEDIATELY.

6. A display of "MODEM COMM." i ndicates that the control ison-line with the central station's remote computer. The controlwill not operate while on-line.

If the problem has been corrected, enter the [Security Code]plus [OFF] twice to clear the display.

Page 45: Ademco V120 User Manual

– 45 –

TROUBLE CONDITIONS7. A display of "HSENS" and a zone number indicates that a

smoke detector has a high sensitivity level, which may causefalse alarms. The detector is probably dirty and should becleaned or replaced.

8. A display of "LSENS" and a zone number indicates that asmoke detector has a low sensitivity level. Detectors with lowsensitivity might not detect a smoke condition. The detectorshould be cleaned or replaced.

Power Failure If the message "AC LOSS " is displayed, the Keypad isoperating on battery power only. If only some lights are out onthe premises, check circuit breakers and fuses and reset orreplace as necessary. CALL FOR SERVICE IMMEDIATELY ifAC power cannot be restored.

SERVICING INFORMATIONYour local Ademco dealer is the person best qualified to serviceyour alarm system. Arranging some kind of regular serviceprogram with him is advisable.Your local Ademco dealer is:Name: Address: Phone:

Page 46: Ademco V120 User Manual

– 46 –

MAINTAINING YOUR SYSTEMTaking Care ofYour System

The components of your security system are designed to be asfree of maintenance as possible. However, there are some thingsyou can do to make sure that your system is in reliable workingcondition.1. Test your system weekly.2. Test the system after any alarm occurs (see TESTING THE

SYSTEM).Replacing

Batteries inWireless Sensors

Wireless sensorsmay not have been

used in your securitysystem

Each wireless sensor in your system has a 9-volt or 3-voltbattery. The system detects a low battery in any wirelesssensor, including smoke detectors, the optional personalemergency transmitter, and the optional portable wirelesskeypad. (A low battery in a portable wireless keypad is detectedas soon as one of its keys is pressed, and the keypad willdisplay 000.)Alkaline batteries provide a minimum of 1 year of operation, and inmost units and applications, provide 2–4 years of service. Actualbattery life will depend on the environment in which the sensor isused, the number of signals that the transmitter in the sensor hashad to send, and the specific type of sensor. Factors such ashumidity, high or low temperatures or large swings in temperature,may all lead to the reduction of actual battery life in an installation.

If you have a low battery in a wireless sensor, a lowbattery message is displayed on the keypad.

In addition, a battery-operated smoke detector with a low batteryalso emits a single "chirp" sound once approximately every 20-30 seconds, identifying itself as the smoke detector with the weakbattery. If you do not replace a smoke detector's low battery, thesmoke detector may sound continuously, as if there were a firealarm.Note: The low battery message comes on as a warning thatbattery replacement in indicated sensor(s) is due within 30 days.In the meantime, the sensor(s) causing the low battery indicationis still fully operational.Important: Use only batteries recommended by your installeras replacement.

Page 47: Ademco V120 User Manual

– 47 –

MAINTAINING YOUR SYSTEMSilencing Low

Battery WarningTones at the

Keypad

The keypad’s warning tones can be silenced by performing anOFF sequence (code plus OFF key), but the Keypad's lowbattery message display will remain on as a reminder that youhave a low battery condition in one or more of your sensors.When you replace the weak battery with a fresh one, the sensorwill send a "good battery" signal to the control as soon as thesensor is activated (opening/closing of door, window, etc.),causing the low battery display to turn off. If the sensor is notactivated, the display will automatically clear withinapproximately 1 hour.

Routine Care • Treat the components of your security system as you would anyother electrical equipment. Do not slam sensor-protected doors orwindows.

• Keep dust from accumulating on the keypad and all protectivesensors, particularly on motion sensors and smoke detectors.

• The keypad and sensors should be cleaned carefully with a drysoft cloth. Do not spray water or any other fluid on theunits.

IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS

In the event of telephone operational problems, disconnect thecontrol by removing the plug from the RJ31X phone wall jack. Werecommend that your certified installer demonstrate disconnectingthe phones on installation of the system. Do not disconnect thephone connection inside the control/communicator. Doing so willresult in the loss of your phone lines. If the regular phone workscorrectly after the control/communicator has been disconnectedfrom the phone lines, the control/communicator has a problem andshould be returned for repair. If upon disconnection of thecontrol/communicator, there is still a problem on the line, notify thetelephone company that they have a problem and requestprompt repair service. The user may not under any circumstances(in or out of warranty) attempt any service or repairs to thesystem. It must be returned to the factory or an authorisedservice agency for all repairs.

Page 48: Ademco V120 User Manual

– 48 –

QUICK GUIDE TO

SYSTEM FUNCTIONSFUNCTION PROCEDURE COMMENTSCheck Zones Press [✱] To view faulted zones when system not

ready.Display All Press and hold [✱] Displays all alpha descriptors programmedDescriptors for 5 seconds by installer.Arm System Enter code Arms system in mode selected.

Press arming key desired (AWAY, STAY, INSTANT,

MAXIMUM)Disarm System Enter code Disarms system and silences alarms.

Press OFF [1]Bypass zones Enter code Bypassed zones are unprotected and will

Press BYPASS [6] not cause an alarm if violated.Enter zone numbers to bebypassed (use 3-digit entries)

Quick Bypass Enter code Bypasses all faulted zones automatically.Press BYPASS [6]Press [#]

Chime Mode Enter code Keypad will sound if doorsPress CHIME [9] or windows are violated while system

disarmed.Test Mode Enter code Sounds alarm sounder and allows sensors

to be tested.Press TEST [5]

View Messages Press and hold [0] for at least Message from central station will appear.5 seconds.

View User Enter user's code Displays partitions & authorityCapabilities Press [✱] + [✱] levels assigned to the user.

Page 49: Ademco V120 User Manual

– 49 –

QUICK GUIDE TO

SYSTEM FUNCTIONSFUNCTION PROCEDURE COMMENTSGOTO Partition Enter security code Allows a user at one keypad to perform

Press [✱] functions in another partition,Enter partition number (1-8) if that user is authorisd to do so.0 returns to default partition

Add a User Enter master/manager code Master & Manager level users can addPress CODE [8] users to the system, each with its ownEnter new user's user number code and authority level.Enter code for that userAt prompt, enter authority forthat user in this partition (1-5)Follow prompts, 1=Yes, 0=No

Change a user's Enter master/manager code Master & Manager level users can changeCode Press CODE [8] their own or other users' codes.

Enter user's 3-digit numberEnter new code for that userPress 0 (No) at prompt.

Delete a User Enter master/manager code Master & Manager level users can deletePress CODE [8] users.Enter user no. to be deleted A user can only be deleted by a user withEnter master/manager code higher authority level.Press 1 (Yes) at prompt.

Self-Help Press and hold any function Will display abbreviated instructions for thekey for at least 5 seconds. key pressed.

Page 50: Ademco V120 User Manual

– 50 –

SUMMARY OF AUDIBLE

NOTIFICATION(ALPHA DISPLAY KEYPADS)

SOUND CAUSE DISPLAYLOUD,INTERRUPTED*Keypad & External

FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed.

LOUD,CONTINUOUS*Keypad & External

BURGLARY/AUDIBLEEMERGENCY ALARM

ALARM is displayed; descriptor of zone in alarm is alsodisplayed.

ONE SHORTBEEP(not repeated)Keypad only

a. SYSTEM DISARMb. SYSTEM ARMING ATTEMPTWITH AN OPEN ZONE.c. BYPASS VERIFY

a. DISARMED/READY TO ARM is displayed.b. The number and descriptor of the open protection zone isdisplayed.c. Numbers and descriptors of the bypassed protection zonesare displayed (One beep is heard for each zone displayed).Subsequently, the following is displayed: DISARMEDBYPASS Ready to Arm

ONE SHORTBEEP(once every 15seconds) Keypadonly

SYSTEM IS IN TEST MODE Opened Zone identifications will appear.

ONE BEEP every60 sec. Keypad only

LOW BATTERY AT A TRANSMITTER LO BAT displayed with description of transmitter.

TWO SHORTBEEPS Keypadonly

ARM AWAY OR MAXIMUM ARMED AWAY or ARMED MAXIMUM is displayed. RedARMED indicator is lit.

THREE SHORTBEEPSKeypad only

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYSTEMIS IN CHIME MODE.c. ENTRY WARNING**

a. ARMED STAY ZONE BYPASSED or ARMED INSTANTZONE BYPASSED is displayed. Red ARMED indicator is lit.b. CHIME displayed, descriptor of open protection zone will bedisplayed if the [✱] key is pressed.c. DISARM SYSTEM OR ALARM WILL OCCUR isdisplayed.

RAPID BEEPINGKeypad only

a. TROUBLEb. AC POWER LOSS ALERT***c. MEMORY OF ALARM

d. SYSTEM LOW BATTERYe. LAST 5 SECONDS OF EXIT DELAYWARNING

a. CHECK displayed. Descriptor of troubled protection zoneis displayed.b. AC LOSS displayed (may alternate with other displays thatmay be present).c. FIRE or ALARM is displayed; descriptor of zone in alarmis displayed.d. SYSTEM LOW BATTERY is displayed.e. ARMED AWAY or ARMED MAXIMUM is displayed,along with You May Exit Now .

SLOW BEEPINGKeypad only

a. ENTRY DELAY WARNING**

b. EXIT DELAY WARNING(if programmed)

a. DISARM SYSTEM OR ALARM WILL OCCUR isdisplayed. Exceeding the delay time without disarming causesalarm.b. ARMED AWAY or ARMED MAXIMUM is displayedalong with You May Exit Now

* If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.** Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

Page 51: Ademco V120 User Manual

– 51 –

WARNING!THE LIMITATIONS OF THIS ALARM SYSTEM

While this system is an advanced design security system, it does not offer guaranteed protection againstburglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject tocompromise or failure to warn for a variety of reasons. For example:• Intruders may gain access through unprotected openings or have the technical sophistication to bypass

an alarm sensor or disconnect an alarm warning device.• Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices

will not work without power. Battery operated devices will not work without batteries, with dead batteries,or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC powersupply is cut off for any reason, however briefly.

• Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarmreceiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if ametal object is moved into the path.

• A user may not be able to reach a panic or emergency button quickly enough.• While smoke detectors have played a key role in reducing residential fire deaths, they may not activate or

provide early warning for a variety of reasons in as many as 35% of all fires. Some of the reasons smokedetectors used in conjunction with this System may not work are as follows. Smoke detectors may havebeen improperly installed and positioned. Smoke detectors may not sense fires that start where smokecannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors.Smoke detectors also may not sense a fire on another level of a residence or building. A second floordetector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors havesensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors maynot always warn about fires caused by carelessness and safety hazards like smoking in bed, violentexplosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits,children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of thesmoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning toallow all occupants to escape in time to prevent injury or death.

• Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed intheir installation manual. Passive Infrared Detectors do not provide volumetric area protection. They docreate multiple beams of protection, and intrusion can only be detected in unobstructed areas covered bythose beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors,closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting orspraying of any material on the mirrors, windows or any part of the optical system can reduce theirdetection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambienttemperature of protected area approaches the temperature range of 32°C to 40°C the detectionperformance can decrease.

Page 52: Ademco V120 User Manual

– 52 –

WARNING!THE LIMITATIONS OF THIS ALARM SYSTEM

(continued)• Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are

located on the other side of closed or partly open doors. If warning devices sound on a different level ofthe residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms.Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, airconditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, maynot warn hearing-impaired people or waken deep sleepers.

• Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may beout of service or temporarily out of service. Telephone lines are also subject to compromise bysophisticated intruders.

• Even if the system responds to the emergency as intended, however, occupants may have insufficienttime to protect themselves from the emergency situation. In the case of a monitored alarm system,authorities may not respond appropriately.

• This equipment, like other electrical devices, is subject to component failure. Even though this equipmentis designed to last as long as 10 years, the electronic components could fail at any time.

The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequatemaintenance. This alarm system should be tested weekly to make sure all sensors and transmitters areworking properly.Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not asubstitute for insurance. Homeowners, property owners and renters should continue to act prudently inprotecting themselves and continue to insure their lives and property.We continue to develop new and improved protection devices. Users of alarm systems owe it to themselvesand their loved ones to learn about these developments.

Page 53: Ademco V120 User Manual

– 53 –

OWNER'S INSURANCE PREMIUMCREDIT REQUEST

This form should be completed and forwarded to your homeowner's insurance carrier for possible premiumcredit.

A . GENERAL INFORMATION:Insured's Name and Address: _________________________________________________________

__________________________________________________________

Insurance Company: __________________________________ Policy No.: ____________________

ADEMCO's VISTA-120

Type of Alarm: Burglary Fire Both

Installed by: _______________________________________ Serviced by: _____________________ name name

______________________________________ ______________________ address address

B . NOTIFIES (Insert B for Burglary, F for Fire, where appropriate):

Local Sounding Device__________ Police Dept.___________ Fire Dept. __________ Central Station ________________

Name and Address: _________________________________________________________________

C . POWERED BY: A.C. With Rechargeable Power Supply

D . TESTING: Quarterly, Monthly, Weekly, Other

continued on other side

Page 54: Ademco V120 User Manual

– 54 –

OWNER'S INSURANCE PREMIUMCREDIT REQUEST (cont.)

E . SMOKE DETECTOR LOCATIONS: Furnace Room Kitchen Bedrooms Attic

Basement Living Room Dining Room Hall

F . BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door A l l Exter ior

Doors 1st Floor Windows All windows Interior Locations

All Accessible Openings, Including Skylights, Air Conditioners and Vents

G . ADDITIONAL PERTINENT INFORMATION:_________________________________________________________________________________

_________________________________________________________________________________

_________________________________________________________________________________

_________________________________________________________________________________

Signature:____________________________________________________ Date:_______________

Page 55: Ademco V120 User Manual

– 55 –

INDEX4285 VIP module ................................ 6, 24AC LOSS ............................................. 45Access another partition ......................... 32Access door ......................................... 21Add a user ............................................ 29Ademco dealer ...................................... 45Alarm .................................................... 4Armed ................................................... 4Audible emergency ................................ 22Authority level ....................................... 26Authority levels ................................ 27, 28Away ...................................... 4, 16, 19, 32Burglary ................................................. 3Burglary protection .................................. 4Bypassing ............................................ 12Call service .......................................... 44Change a user's code ............................. 31Check.................................................. 44Chime ............................................... 4, 20Closing time .......................................... 36Code ................................................... 29Comm. ................................................. 44Delaying the closing time ......................... 36Delete a user ........................................ 31Descriptors .......................................... 10Device timers ..................................... 5, 40Disarm ................................................. 18Duress code ......................................... 26Emergency ............................................. 3Entry delay ........................................... 10Entry/exit ............................................... 3Exit delay ............................................. 10Exit user edit mode ................................ 28Fire ............................................. 3, 22, 43Fire emergency ..................................... 43Fire protection ......................................... 4Global arming ........................................ 32GOTO ............................................ 30, 32GOTO command ...................................... 5Instant ........................................ 4, 15, 32

Keypads ................................................ 7Keyswitch ............................................ 19LO BAT ................................................ 44Low battery .......................................... 46Low battery warning ............................... 47Maintenance ......................................... 46Maximum ..................................... 4, 17, 32Memory of alarm ................................. 4, 18Not ready ............................................. 11Off ............................................ 18, 32, 43Open zones .......................................... 11Open/close schedules ............................ 37Panic keys ........................................... 22Partitioned security system ....................... 3Partitioned system ................................... 3Personal emergency .............................. 22Quick arming ........................................ 26Ready ....................................... 11, 20, 43Ready key ....................................... 10, 11Replacing batteries ................................ 46Schedules ......................................... 5, 36Security code ....................................... 26Security codes ...................................... 26Sensing devices ...................................... 3Silence the alarm ................................... 43Silent emergency ................................... 22Stay ....................................... 4, 14, 19, 32System lo bat ........................................ 44Temporary schedules ........................ 37, 38Temporary users ................................... 29Test key .............................................. 42Time window ......................................... 37Trouble condition ................................... 44User edit mode ...................................... 28User numbers ....................................... 26User's instructions ................................... 6Wireless sensor .................................... 46Zone bypassed ..................................... 14Zone descriptors ................................... 10

Page 56: Ademco V120 User Manual

N5943-8V2 9/98

ADEMCO ONE YEAR LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries andaffiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its security equipment (the"product") to be free from defects in materials and workmanship for one year from date of original purchase,under normal use and service. Seller's obligation is limited to repairing or replacing, at its option, free ofcharge for parts, labor, or transportation, any product proven to be defective in materials or workmanshipunder normal use and service. Seller shall have no obligation under this warranty or otherwise if the productis altered or improperly repaired or serviced by anyone other than the Seller. In case of defect, contact thesecurity professional who installed and maintains your security equipment or the Seller for product repair.This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE ARENO EXPRESS WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIEDWARRANTIES, OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THISPRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR APARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEARFROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, INCLUDINGBUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE BROUGHT WITHIN 12MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL SELLER BE LIABLE TO ANYONEFOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHERWARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVENIF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Some states donot allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental orconsequential damages, so the above limitation or exclusion may not apply to you.Seller does not represent that the product may not be compromised or circumvented; that the product willprevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will inall cases provide adequate warning or protection. Buyer understands that a properly installed andmaintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring withoutproviding an alarm, but it is not insurance or a guarantee that such will not occur or that there will be nopersonal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FORANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCTFAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY ORINDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE,REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASEEXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVEREMEDY AGAINST SELLER. This warranty gives you specific legal rights, and you may also have otherrights which vary from state to state. No increase or alteration, written or verbal, to this warranty isauthorised.

®

165 Eileen Way, Syosset, NY 11791Copyright © 1997 PITTWAY CORPORATION

Page 57: Ademco V120 User Manual

Side A of N5943-8V2

EVENT LOGGING PROCEDURES

General Information

The system has the ability to recordvarious events in a history log whereineach event is recorded in one of fivecategories (listed below), with the timeand date of its occurrence. The EventLog holds up to 224 events, with theoldest event being replaced by thelogging of any new event after the log isfull. Using an alpha keypad, the EventLog can be viewed one category at atime, or can display all events, regardlessof category (ALL EVENT LOG). Thesystem also allows selection ofdisplaying the COMPLETE log, or onlythose events occurring since the lastinstaller service (RECENT). In addition,events in the other partitions can beviewed by users authorised to accessthose partitions. Note that events aredisplayed in chronological order, frommost recent to oldest.

To Display The Event Log

1. Enter CODE + [#] + [6] + [0]

2. Select the display mode.RECENT: Displays only thoseevents occurring since last installerservice.COMPLETE: Displays completeevent log (up to 224 events).Press the desired key, 0 or 1. ENTER 0 = RECENT 1 = COMPLETE

3. Select the partition, 0-8.Enter the partition number for thepartition whose events are to bedisplayed.

Entering 0 (NO) will display allpartitions' events.

SCAN LOG BY PART 0=NO 1-8=PART #

Page 58: Ademco V120 User Manual

Side B of N5943-8V2

EVENT LOGGING PROCEDURES (cont'd)

4. Use the [3] & [1] keys (for next andprevious categories respectively) todisplay the categories of events.Press [8] to select a category anddisplay the first event. Press [8] again foreach subsequent event.Shows burglary alarm occurred in zone 3(003) of partition 1 (P1), at 12:02AM onJanuary 1.P1 01/01 12:02AM Typical EventBURGLARY 003 Log Display

After the last event has beendisplayed, the END OF EVENT LOGmessage appears for a few seconds, thenthe system automatically displays theRECENT/COMPLETE mode selectscreen again (see step 2).

5. To EXIT the Event Log:Press [✱] at any time.

ALARM EVENT LOG Typical CategoryTYPE CCC UUU Select Screen

ALARM EVENT LOGDisplays time and date for zones that haveeither caused an alarm or have been restoredin the selected partition.CHECK EVENT LOGDisplays time and date for zones that havecaused a trouble or supervisory condition inthe selected partition.BYPASS EVENT LOGDisplays time and date for zones that havebeen bypassed in the partition.OPEN EVENT LOGDisplays time, date and user number for eacharming and disarming of the system for thepartition selected.SYSTEM EVENT LOGDisplays time and date for system problems,such as AC Loss, low battery, etc., regardlessof partition.ALL EVENT LOGDisplays all categories of events inchronological order.

See your Installer foradditional information

concerning the event log.