additional information dme design project 2007-1 updated 10/29/07
Post on 20-Dec-2015
214 views
TRANSCRIPT
WheelchairSide View
5.5”
The user has a limited range of
motion to deploy the comm board
~3” from back of tray
Invacare Torque SP Storm Series Wheelchair
3.5”
11”
1.125”
Client’s knees
WheelchairSide View(cont)
11”floor to bottom
of rail
30”floor to tray
3” inboard of edge of tray, < ½”
clearance behind bar at front (where it says “TORQUE”,
~ first 3”) no clearance beyond
this
6” inboard of edge of tray, ¼”
clearance behind
8”tray to foot
rest support bar
6” above tray obstructed by miscellaneous
clips and straps
6” clear
Push Arm Detail
3.5” from edge of tray to push arm
Other information
• The user is left-handed• The user likes the color pink• The wheelchair model can be found here.• The following slides contain some information from
the original communication board senior design team
• Commercial devices the team investigated for comparison can be found here.
• If you need other information, please contact Dr. DeBartolo!
Device Mounting Decision Matrix
Selection Criteria Weight
Ease of manufacture (team) 5%
Ease of design (team) 5%
Integratable with current chair 10%
Difficulty to push off (customer) 25%
Ease of removal (ARC) 5%
Repositionability (ARC) 10%
No interference with chair controls 10%
Low cost 15%
ARC's stated preference 5%
Design For Reach
How far does the LCD needs to in order for the individual to be able to reach.
Use the link length mannequin and the stature of the individual to find the reach
proportions.
Individual’s Stature is 58.0 inches.
Reach length = 0.186(58in) + 0.146(58in) +0.108(58in) = 25.52
inches.
This means that the LCD can be placed 25.52 inches from the shoulders.