PHASE II ATHLETIC FIELD IMPROVEMENTS – LOWER RICHLAND HIGH SCHOOL ADDENDUM NUMBER TWO Page 1 ADDENDUM NUMBER TWO for PHASE II ATHLETIC FIELD IMPROVEMENTS LOWER RICHLAND HIGH SCHOOL RICHLAND COUNTY SCHOOL DISTRICT ONE COLUMBIA, SOUTH CAROLINA Solicitation Number 77000023 PREPARED BY: JHS Architecture Integrated Design 1812 Lincoln Street, Suite 300 Columbia, SC 29201 And Cumming Construction Management, Inc. 720 Lady Street Columbia, South Carolina 29201 DATE OF ISSUE: January 19, 2018 TO: ALL BIDDERS OF RECORD This addendum modifies the Contract Documents only in the manner and to the extent stated herein and shown on any accompanying drawings and will become a part of the Contract Documents. Except as specified or otherwise indicated by this addendum, all work shall be in accordance with the basic requirements of the Contract Documents. BIDDER SHALL ACKNOWLEDGE RECEIPT OF ADDENDUM IN THE SPACE PROVIDED ON THE BID FORM. FAILURE TO DO SO MAY CONSTITUTE AN INFORMALITY IN THE BID. This addendum consists of 3 pages and the following attachments: Specification Section: None Drawings: None Sketches: ABD-1, ABD-2 Lighting Submittals Substitutions: Two (2) I. CHANGES TO BIDDING REQUIREMENTS Item No. Description 1. None.

Upload: lenguyet

Post on 22-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

PHASE II ATHLETIC FIELD IMPROVEMENTS – LOWER RICHLAND HIGH SCHOOL ADDENDUM NUMBER TWO

Page 1

ADDENDUM NUMBER TWO

for

PHASE II ATHLETIC FIELD IMPROVEMENTS LOWER RICHLAND HIGH SCHOOL

RICHLAND COUNTY SCHOOL DISTRICT ONE COLUMBIA, SOUTH CAROLINA

Solicitation Number 77000023

PREPARED BY:

JHS Architecture Integrated Design

1812 Lincoln Street, Suite 300 Columbia, SC 29201

And

Cumming Construction Management, Inc.

720 Lady Street Columbia, South Carolina 29201

DATE OF ISSUE: January 19, 2018

TO: ALL BIDDERS OF RECORD This addendum modifies the Contract Documents only in the manner and to the extent stated herein and shown on any accompanying drawings and will become a part of the Contract Documents. Except as specified or otherwise indicated by this addendum, all work shall be in accordance with the basic requirements of the Contract Documents. BIDDER SHALL ACKNOWLEDGE RECEIPT OF ADDENDUM IN THE SPACE PROVIDED ON THE BID FORM. FAILURE TO DO SO MAY CONSTITUTE AN INFORMALITY IN THE BID. This addendum consists of 3 pages and the following attachments:

Specification Section: None

Drawings: None Sketches: ABD-1, ABD-2 Lighting Submittals Substitutions: Two (2)

I. CHANGES TO BIDDING REQUIREMENTS Item No. Description 1. None.

PHASE II ATHLETIC FIELD IMPROVEMENTS – LOWER RICHLAND HIGH SCHOOL ADDENDUM NUMBER TWO

Page 2

II. GENERAL CLARIFICATIONS:

Item No. Description

1. Bleacher Foundation Spoils: Foundations spoils generated by the Owner’s Bleacher vendor have been stockpiled in the northeast corner of the site beyond the visitor parking area for the visitor side and are currently being stockpiled adjacent to the field house area on the home side. The General Contractor shall be responsible for removal and disposal of these soils off the Owner’s property. For bidding purposes, the bidder is to assume a total quantity of 200 CYD of material for haul off and disposal. Any amount above or below this amount will be negotiated for a contract adjustment, if necessary, after final quantities are confirmed.

III. CHANGES TO DIVISION ONE SPECIFICATIONS:

1. None.

IV. CHANGES TO TECHNICAL SPECIFICATIONS AND DRAWINGS:

SPECIFICATIONS Item No. Description

1. None. DRAWINGS

Item No. Description

1. Sheet ASD1.0 – Change scale on drawing to read 1” = 30’. See Note No. 15 – This is a

valid requirement. The existing trench drain covers are to be replaced with same type as are now installed.

2. Sheet AS1.4 – Sections 2/AS1.4 & 3/AS1.4– Footing dimensions to be 2’-0” wide x 1’-0” deep. Reinforcing as called for in detail. The front rail post is part of the bleachers and not part of this contract. Change the brick veneer to be Modular size brick, same color as used for the new buildings. The top and end returns will be a full brick and a half brick with no cut ends exposed. Full brick towards field.

3. Sheets A1.00 – See Bulletin Drawing ABD-2 for wall section for existing building.

4. Sheet A5.00 – See Bulletin Drawing ABD-1 for clarifications to Section 3/A5.00 - Ticket

Booth Window.

5. Sheet S2.00 – Section 3/S2.00 – Rebar size for the two bars shown above the #6 dowels in this section will be 2 #4 bars continuous.

6. Sheet LS1.0 – Delete reference to Alternate No. 1 on the East & West ends of the field. There is not an Alternate No. 1.

PHASE II ATHLETIC FIELD IMPROVEMENTS – LOWER RICHLAND HIGH SCHOOL ADDENDUM NUMBER TWO

Page 3

7. Sheet E101 - Provide eight (8) type W6E lighting fixtures for the existing concessions building. Locate on new exterior veneer wall as directed by the Architect. Location of lights to be as follows: 2 on each end, 2 on side facing Lower Richland Boulevard and 2 above the serving windows on the field side. Connect to the existing lighting circuit. Time clock control. Provide additional unswitched conductor for battery backup.

Provide one (1) type W2E lighting fixture for the existing concessions building. Locate above egress door from Concession E06. See A1.00 for door E07. Connect to the existing lighting circuit. Time clock control along with fixtures W6E provided. Provide additional unswitched conductor for battery backup. Add one (1) X1W light fixture in the Concession E06 to be located near FACP on the ceiling. Connect to nearest existing lighting circuit. Provide additional unswitched conductor for battery backup.

V. APPROVED EQUALS: The following Manufactures have met requirements for prior approval for substitution of specified

materials/products. Approved products must meet all specifications set forth in the Project Manual unless noted otherwise here in this addendum.

Product Manufacturer/ Installer Section 09 9000 Rose Talbert Paints Lighting Submittal Premier Lighting and Control, LLC Lighting Submittal Carolina Architectural Lighting and Design

END OF ADDENDUM NUMBER TWO

SCALE: 3/4" = 1'-0"

BULLETIN DRAWING NO.

LOWER RICHLAND HIGH SCHOOLHOPKINS, SOUTH CAROLINA

PROJECT

REVISIONS TO WALL SECTION

ABD-1

TITLE

JOB NO.

01/19/2018DRAWN BYDATE

CMB

11201812 LINCOLN STREETTHIRD FLOORCOLUMBIA, SC 29201PHONE:FAX:

1.803.252.24001.803.252.1630

.

JHS Architecture :

Integrated Design TICKET WINDOW CLARIFICATION

5"

1/4"

4"

1'-6"

8" CMU LINTEL BLK SEE

STRUCTURAL

BRICK SOLDIER COURSE

FORMED AND POURED IN-PLACE

CONCRETE WINDOW SILL-START

SLOPE AT OUTSIDE FACE OF

BLOCK

PLASTIC LAMINATE

COUNTER TOP W/ANGLE

BRACKET SUPPORTS AT

1/3 POINTS

1

1

2

" X 6" HOLLOW METAL FRAME,

2'-0" WIDE X 4'-6" HIGH WITH

1

4

"

TEMPERED GLASS CENTERED

GLAZED. SPEAK HOLE TO BE 4'-2"

AFF CENTERED IN WINDOW.

PROVIDE PASS THROUGH AT SILL.

SPEAK HOLE TO BE # 425, 6"

DIAMETER. PASS THROUGH TO BE

# 724, 8" DIAMETER. BOTH TO BE

PROVIDED BY NISSEN OR EQUAL.

3

1

2

" X 3

1

2

" X

1

4

"

STEEL ANGLE LINTEL

4'-6"

WALL SECTION AT TICKET BOOTH3

A5.00

SCALE: 3/4" = 1' - 0"

RICHLAND COUNTY SCHOOL DISTRICT ONEPHASE II ATHLETIC FIELD IMPROVEMENTS

BULLETIN DRAWING NO. PROJECT

WALL SECTION AT EXISTING

ABD-2

TITLE

JOB NO.

01/18/2018DRAWN BYDATE

CMB

11201812 LINCOLN STREETTHIRD FLOORCOLUMBIA, SC 29201PHONE:FAX:

1.803.252.24001.803.252.1630

.

JHS Architecture :

Integrated Design CONCESSION BUILDING

EXISTING 4" CONC. SLAB ON GRADE

EXISTING CONCRETE FOOTING

EXISTING SOFFIT AND FASCIA

BOARD TO REMAIN. REMOVE

EXISTING FRIEZE BOARD.

EXISTING CONCRETE SIDEWALK

NEW FOOTING - SEE 3/S200

INSTALL NEW 1" X 2" FRIEZE BOARD

ON FACE OF NEW BRICK VENEER.

NEW BRICK VENEER, ANCHOR TO

EXISTING CMU WALL WITH HOHMANN &

BARNARD DW-10 ANCHORS AT 16" OC

VERTICALLY, AND 16" OC HORIZONTALLY.

STAINLESS STEEL TYPE 304, 12 GAUGE,

STANDARD

3

16

" TIE X 3

1

2

" LONG.

EXISTING 8" CONCRETE BLOCK,

13 COURSES HIGH - ADD

DAMPPROOFING TO EXTERIOR FACE

PRIOT TO INSTALLING BRICK VENEER

NEW CONCRETE SIDEWALK

WHERE DEMO'D FOR FOOTING

SAW CUT JOINT PARALLEL WITH

BUILDING WALL.

THROUGH WALL FLASHING TO

CMU WITH TEMINATION BAR WITH

WEEPS 24" O.C.

BRICK SOLDIER COURSE

BRICK SOLDIER COURSE

BRICK SOLDIER COURSE

1'-0"

LOWER RICHLAND HIGH SCHOOLHOPKINS, SOUTH CAROLINA

RICHLAND COUNTY SCHOOL DISTRICT ONEPHASE II ATHLETIC FIELD IMPROVEMENTS

EXISTING DOWNSPOUTS AT FOUR

CORNERS OF BUILDING TO BE REMOVED

AND RE-INSTALLED AFTER BRICK VENEER

IS COMPLETED.

EXISTING GUTTER TO REMAIN.

RE-LOCATE DOWNSPOUTS AFTER

BRICK VENEER IS COMPLETED.

FF00010 Page 1/1

Jan 16, 2018

RE: Lower Richland HS Athletic Field ImprovementsColumbia SC

Type MFG PartC2 Columbia LCAT24-40LWG-EDU

C2E Columbia LCAT24-40LWG-EDU-ELL14F2 Columbia AWN4-232-ULT-B232PUNVHE-B-U

F2E Columbia AWN4-232-B232PUNVHE-B-U-EL141GA Luminaire LED VPF84-50W-4000K-120-277-OP-XXX-

DIMGAEM Luminaire LED VPF84-50W-4000K-120-277-OP-XXX-

DIM-EMB310PT Architectural Area Lighting PROV-T5-32LED-4K-450-BL-STND_

MNT-WIRED120-277VPT-INV-2-ALONE Lightalarms LMIU-125

PT-INV-8-LEFT Lightalarms LMIU-720PT-INV-17-RIGHT Lightalarms LMIU-1000

SB Hubbell Lighting Inc ARS-24L4K-105-5M-U-DB-ARS-CSW2E Lightalarms CAM-ACSD-XXW6E Hubbell Lighting Outdoor TRP1-12L-20-4K7-4-U-DB

W6-INV-CONCESS-E1 Lightalarms LMILC-55W6-INV-VISIT-E102 Lightalarms LMIU-250

W6-INV-TICK-E102 Lightalarms LMIU-125W6-INV-WOMM-REST Lightalarms LMIU-125W6-INV-HOME-TICK-E Lightalarms LMIU-125

X1C Lightalarms WW-XVE-1-RX1W Lightalarms WW-XVE-1-RZ1 Deco Lighting D824-LED-100-40-UNV-LP-T3-PM-BL-

MSZ1 POLE Hubbell Lighting Inc RTA-20-60-B-A2-BL

Z1E Deco Lighting D824-LED-100-40-UNV-LP-T3-PM-BL-MS

Z1E POLE Hubbell Lighting Inc RTA-20-60-B-A2-BLZ1-INV-TOP-E002 Lightalarms LMIU-125

Z1-INV-BOTTOM-E002 Lightalarms LMIU-400DT Hubbell Control Solutions OMNIDT2000PP Hubbell Control Solutions UVPPWG Hubbell Control Solutions WGOMNI

Approved for bidding. Lighting fixture representative and Electrical Contractor shall coordinate final sizing of emergency lighting battery inverters to suit LED lighting fixtures. All inverters shall be rated for LED lighting fixtures and in-rush currents. Final colors of all lighting fixtures by Architect.

B. McDaniel 1/17/18

Remarks:Page 1 of 1

To: SIMS GROUP ENGINEERS, INC. 800 COLUMBIANA DRIVE SUITE 208 IRMO, SC 29063

Attn: BENNY McDANIEL

Submittal

Source Quote: 18-0035 Entry Date: 1/12/2018 Project: LOWER RICHLAND HS ATHLETIC FIELD IMPROV

Original Submittal for Prior Approval 1 Copy of Submittals is Attached

Type Mfg DescriptionPT PEMCO LIGHTING

PRODUCTS, INC.FLOR II NL 70W60C4K MODIFIED

SB Cooper Ltg CLCSLED-54-UNV CLCSPEND

Approved for bidding as noted. Lighting fixture representative and Electrical Contractor shall coordinate final sizing of emergency lighting battery inverters to suit LED lighting fixtures. All inverters shall be rated for LED lighting fixtures and in-rush currents. Final colors of all lighting fixtures by Architect.B. McDaniel 1/17/18

Fixture SB: Provide 92 watt fixture.B. McDaniel 1/17/18

TERMS OF QUOTATIONPAYMENT TERMS: NET 30 DAYSFREIGHT TERMS: FOB FACTORY

FREIGHT PREPAID: ORDERS OVER $4,000 EAST OF MISSISSIPPIORDERS OVER $5,000 WEST OF THE MISSISSIPPINOT APPLICAPABLE FOR PRE-SHIPMENT OF ANCHORBOLTS

MINIMUM ORDER: $150QUOTE VALID FOR 30 DAYS UNLESS OTHERWISE SPECIFIED

*ANY STATE, COUNTY OR LOCAL TAXES THAT MAY APPLY TO PRODUCTS SOLD IN YOUR STATE WILL BE THE RESPONSIBILITY OF THEPARTY ISSUING THE PURCHASE ORDER. IF TAXES ARE IMPOSED FOLLOWING THE DATE OF SHIPMENT, ACCORDINGLY, THE

RESPONSIBILITY FALLS ON THE PARTY ISSUING THE PURCHASE ORDER, AND WILL BE BILLED* ALL TERMS AND CONDITIONS AS PUBLISHED BY PEMCO ON OUR WEB SITE APPLY TO ALL ORDERS GENERATED THROUGH THIS QUOTATION

Q U O T A T I O N TO: FROM:

PREMIER, SC VANCE GROSSO

ATTENTION: DATE:

GORDON THOMAS 1-12-18 REV 1: 1-15-18

ESTIMATED LEAD TIME:

10 WEEKS 10 %

JOB NAME:

LR STADIUM RENOVATION PRE-PAID FREIGHT DOES NOT APPLY TO FIBERGLASS, CONCRETE OR STEEL POLES UNLESS OTHERWISE SPECIFIED

QTY DESCRIPTION

FLORENCE II OPEN AIR LED FIXTURE W/ MODIFICATIONS

26 FLOR 4A NL 45W35C4K-UNV-TYPE V-GF18-MOD PLC 4” PIER-XX

XX= PRICED IN STANDARD COLOR POWDERCOAT FINISH

FIXTURE WILL HAVE 4 ARMS

MODIFIED BASE TO ACCEPT 4” PIPE OF EXISTING PIER WALL

RE-CONFIRM ALL EXISTING PIER PIPE SIZES

ARRA- MADE IN USA

4600 DELIVERED LUMENS, DIMMABLE DRIVER-SPECIFY CONTROL OR EXTRA LEAD WIRES.

5 YEAR WARRANTY ON LED

ALUMINUM FIXTURE / POLYESTER POWDERCOAT FINISH

Florence with standard size base >>> scroll to next page….

Page 2 of 2

FLOR 4A NL with PLC9 bottom capital …prior to 4” pier shaft modification >

>>>finial on top # GF18

OPTIONS FINISH

ORDERING FORMAT

LED ARRAY

118115118115118115117

1121091121091121091178785878587859780808087

65656565656565

65656565656565

8080808080808080808080

MODEL# WATTAGE CRICCT40467080103120145

42477080103120145404670801031201454680120145

40W35C5K45W35C5K70W60C5K80W60C5K100W90C5K120W90C5K145W90C5K

40W35C4K45W35C4K70W60C4K80W60C4K100W90C4K120W90C4K145W90C4K40W35C3K45W35C3K70W60C3K80W60C3K100W90C3K120W90C3K145W90C3K45W35C2K80W60C2K120W90C2K145W90C2K

Type II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, V

Type II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, VType II, III, IV, V

INITIAL LUMENS472052908260920011,90013,92016,965

448050147840872011,53613,08016,9653480391060906800896110,20014,06536806400960012,615

SYSTEM EFFICACY IES DISTRIBUTIONS5K5K5K5K5K5K5K

4K4K4K4K4K4K4K3.5K3.5K3.5K3.5K3.5K3.5K3.5K2.7K2.7K2.7K2.7K

LED LIGHT ENGINE SPECIFICATIONS:

SURGE PROTECTION DEVICE MEETS IEEE C62.41 2002 C HIGH 10kA See spec sheet on page J12.

Description : FLOR II NL 70W60C4K MODIFIEDProject Name: LOWER RICHLAND HS ATHLETIC FIELD IMPROVNotes:

TYPE:

PT

18 3/4"

34 1/4

Fixture to have

four arms

70W60C4K 70 7840 112 4K 65 V

Lumark

SPECIFICATION FEATURES

ConstructonHOUSING: Durable, die-cast aluminum housing with (4) 1/2” NPS side conduit entries. UL 1598 wet location listed and IP66 ingress protection rated.

OpticalSolid state LED luminaires are thermally optimized with four lumen packages. Available in cool 5000K or neutral 4000K LED color temperatures (CCT).

ElectricalLED driver and related electrical components are hard mounted to the die-cast housing for optimal heat sinking and operating efficiency. Integral driver incorporates internal fusing designed to withstand a 4kV surge test and is rated for 120-277V, 50/60Hz with an operating temperature range of -40°C to 25°C. CLCSLED LED systems maintain greater than 94% of the initial light output after 50,000 hours of operation.

MountingStandard fixture mounts to a square or octagonal 4” surface or recessed j-box via heavy-gauge quick mount bracket.

FinishHousing finished in a UV stabilized powder coat paint for superior protection against fade and wear. Standard color is bronze.

Options3/4” pendant mount in 6” length available as an option.

WarrantyFive-year warranty.

The CLCSLED luminaire provides a slim, low profile, traditional design with high performance energy efficient illumination. Rugged die-cast aluminum construction and gasketed housing make the CLCSLED virtually impenetrable to contaminants. UL/cUL wet location listed. Replaces up to 400W metal halide equivalent. The CLCSLED canopy luminaire mounts quickly to a variety of surfaces making it ideal for bank drive-thrus, covered side walks, hospitality entryways, and retail drive-thrus.

DESCRIPTION

Catalog # Type

Date

Project

Comments

Prepared by

TD515008EN2017-03-28 15:49:28

3-15/16"[99mm]

10-5/16"[261mm]Square

14"[355mm]Square

6"[150mm]

36W-56W Model 92W-121W Model

DIMENSIONS

T E C H N I C A L D A T AUL/cUL Wet Location ListedIP66 Rated25°C Maximum Ambient TemperatureDesignLights ConsortiumTM Qualified*

S H I P P I N G D A T AApproximate Net Weight:5-8 lbs. (2.26-3.71 kgs.)

CLCSLED

36W, 56W, 92W, 121W

LED

CANOPY LUMINAIRE

*www.designlights.org

Description : CLCSLED-54-UNV CLCSPENDProject Name: LOWER RICHLAND HS ATHLETIC FIELD IMPROVNotes:

TYPE:

SB

Specifications and dimensions subject to change without notice.

Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting

CLCSLED

Sample Number: CLCSLED-40-SM-UNV

Product Family 1 Lamp Wattage Mount Voltage Options (Add as Suffi x) 2 Accessories (Order Separately)

CLCSLED 40=36W55=56W86=92W117=121W

SM= Surface Mount UNV=120-277V Blank=70 CRI / 4000K7050=70 CRI / 5000KBPC=120-277V Button Photocontrol10kV=10kV Surge Protection

CLCSPEND=6” Long, 3/4” Pendant Mount

NOTES: 1. Available in bronze only.2. Extended lead times apply.

ORDERING INFORMATION

TD515008EN2017-03-28 15:49:28

Voltage (V)

Model Series

CLCSLED-40 CLCSLED-55 CLCSLED-86 CLCSLED-117

Current (A) Current (A) Current (A) Current (A)

120V 0.31 0.47 0.73 0.45

208V 0.18 0.27 0.42 0.55

240V 0.15 0.23 0.36 0.47

277V 0.13 0.20 0.32 0.41

CURRENT DRAW

4000K CLCSLED-40 CLCSLED-55 CLCSLED-86 CLCSLED-117

Delivered Lumens 4,839 7,230 11,494 13,828

CCT (Kelvin) 4000 4000 4000 4000

CRI (Color Rendering Index) 70 70 70 70

Power Consumption (Watts) 36 56 92 121

5000K CLCSLED-40 CLCSLED-55 CLCSLED-86 CLCSLED-117

Delivered Lumens 4,739 6,878 11,279 13,882

CCT (Kelvin) 5000 5000 5000 5000

CRI (Color Rendering Index) 70 70 70 70

Power Consumption (Watts) 36 56 90 120

POWER AND LUMENS

AmbientTemperature

LumenMultiplier

10°C 1.03

15°C 1.02

25°C 1.00

LUMEN MULTIPLIER

AmbientTemperature

TM-21 Lumen Maintenance

(50,000 Hours)

Theoretical L70 (Hours)

25°C 94.88% 346,000

LUMEN MAINTENANCE

CLCSLED55=56W

UNV=120-277V CLCSPEND=6” Long, 3/4” Pendant MountBlank=70 CRI / 4000K