LCMS NE District Office 05/25/18 Seward, Nebraska TCEP No.: 119-001-17 ADDENDUM NO. 3 ADD3-1 ADDENDUM NO. 3 The Architect/ Engineer issues this addendum, applicable to the above named project, to all known Contractors before receipt of proposal. This addendum includes Item Number 3-1 thru 3-8. This addendum item shall be fully incorporated into the Bidding/Contract Documents and have the same force and effect as though originally included. The Bidder shall acknowledge receipt of this Addendum No. 3 on the Bid Proposal Form in the place provided. GENERAL Bidder Questions: Item 3-1: Question: One of the trees marked for removal is growing into the existing fence which is noted to remain. How should this be handled? Answer: The tree shall be removed, it is a hazard, but there will need to be coordination with the Owner of the property to the north. This coordination has not taken place yet. Item 3-2: Question: There is a tree growing along the wooden fence that is leaning. The tree is not currently noted to be removed, should this tree be removed? Answer: This tree is not located on the District Office’s property and it will not be removed as part of this project. Drawings Item 3-3: Sheet G0.00 Index of Drawings Civil Engineer Stamp & Sheet C1.01 added to the index. CIVIL Item 3-4: Sheet C1.01 Sanitary Sewer Plan Issued new sheet in its entirety. MECHANICAL Drawings Item 3-5: Sheet M6.01 Mechanical Schedules Referencing the condensing unit schedule, note 8 shall be omitted from the documents. CU-3 & 4 will not be twinned together. All remaining remarks apply to each of the condensing units.

Upload: others

Post on 14-Oct-2019

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ADDENDUM NO. 3 - clarkenersen.com No. 3 with... · sm shr shthg shvl sim sj scrn sd sect sgl knee brace janitor's closet invert elevation knockout joint joist janitor invert interior

LCMS NE District Office 05/25/18

Seward, Nebraska

TCEP No.: 119-001-17

ADDENDUM NO. 3 ADD3-1

ADDENDUM NO. 3 The Architect/ Engineer issues this addendum, applicable to the above named project, to all known Contractors before receipt of proposal. This addendum includes Item Number 3-1 thru 3-8. This addendum item shall be fully incorporated into the Bidding/Contract Documents and have the same force and effect as though originally included. The Bidder shall acknowledge receipt of this Addendum No. 3 on the Bid Proposal Form in the place provided.

GENERAL

Bidder Questions:

Item 3-1: Question: One of the trees marked for removal is growing into the existing fence which is noted to remain. How should this be handled? Answer: The tree shall be removed, it is a hazard, but there will need to be coordination with the Owner of the property to the north. This coordination has not taken place yet.

Item 3-2: Question: There is a tree growing along the wooden fence that is leaning. The tree is not currently noted to be removed, should this tree be removed? Answer: This tree is not located on the District Office’s property and it will not be removed as part of this project.

Drawings

Item 3-3: Sheet G0.00 – Index of Drawings

Civil Engineer Stamp & Sheet C1.01 added to the index.

CIVIL

Item 3-4: Sheet C1.01 – Sanitary Sewer Plan

Issued new sheet in its entirety.

MECHANICAL

Drawings

Item 3-5: Sheet M6.01 Mechanical Schedules

Referencing the condensing unit schedule, note 8 shall be omitted from the documents. CU-3 & 4 will not be twinned together. All remaining remarks apply to each of the condensing units.

Page 2: ADDENDUM NO. 3 - clarkenersen.com No. 3 with... · sm shr shthg shvl sim sj scrn sd sect sgl knee brace janitor's closet invert elevation knockout joint joist janitor invert interior

LCMS NE District Office 05/25/18

Seward, Nebraska

TCEP No.: 119-001-17

ADDENDUM NO. 3 ADD3-2

Item 3-6: Sheet M6.01 Mechanical Schedules

Referencing the split system schedule, note 5 shall be omitted from the document. In addition, the interior blower coil shall have a nominal 12,000 BTU capacity. The blower coil model number indicates a 1.5 ton coil this shall be corrected to a 1.0 ton.

Item 3-7: Sheet M6.01 Mechanical Schedules

Referencing the fan schedule, note 6 shall only apply to EF-5 & 6. Division 23 contractor to coordinate with Division 26 contractor wiring the provided switch to EF-5 & 6 per note 3.

ELECTRICAL

Drawings

Item 3-8: Sheet E1.10 – Lower Level & First Floor Lighting Plan

In looking at the Lower Level Lighting Plan, the door to Warming Kitchen 007 has been changed so that it now swings out into the corridor, conflicting with the emergency wall pack fixture located on the north wall of Corridor 005. Move this north emergency fixture to the north end of the west wall of Corridor 005, locating it near the corner.

END OF ADDENDUM NO. 3

Page 3: ADDENDUM NO. 3 - clarkenersen.com No. 3 with... · sm shr shthg shvl sim sj scrn sd sect sgl knee brace janitor's closet invert elevation knockout joint joist janitor invert interior

MATERIAL SYMBOLS

ELEVATION INDICATIONS

PARTITION INDICATIONS

FINISHES

INSULATION

GLASS

WOOD

METAL

STONE

MASONRY

CONCRETE

EARTHWORKS

CONCRETE/PLASTER

SHINGLES/SIDINGGLASS

BRICK

WOOD STUD

SHEET METAL

CERAMIC TILE

METAL STUD

CONCRETE MASONRY UNIT

GRAVEL/POROUS

ACOUSTICALTILE

FILLBATT/LOOSE

GLASS

CARPET ANDPAD

CERAMIC TILE

RIGID

STRUCTURAL

SPRAY/FOAM

GLASS BLOCK

ALUMINUM

FINISH

BLUESTONE/SLATE/SOAPSTONE/FLAGGING

STEELBRASS/BRONZE

ROUGH SHIM

RUBBLE LIMESTONE

BLOCKCONCRETE

CONCRETE

NON COMPACTEDEARTH

COMMON/FACEBRICK

PLASTERSAND/MORTAR/

FIRE BRICK

EARTH/COMPACTFILL FILL

WALLBOARDGYPSUM

PLYWOOD

FACING TILESTRUCTURAL

PRECAST CONCRETE

CONCRETE MASONRYCAST-IN-PLACE CONCRETE

SCALE:

VIEW NAME1/8" = 1'-0"1

1

1i

A1011

SIM

REFERENCE SYMBOLS

100'-0"FIN. FLR.

REVISION TAG & CLOUD INDICATOR

DEMOLITION INDICATOR

MATCH LINE

WALL TYPE REFERENCE

ELEVATION REFERENCE

GRID LINE

WINDOW/OPENING IDENTIFIER

DOOR/OPENING IDENTIFIER

ROOM IDENTIFIER

CROSS SECTION REFERENCE

ELEVATION REFERENCE

DETAIL REFERENCE

DETAIL REFERENCE NUMBER

SHEET ON WHICH IT IS FOUNDDETAIL OR SECTION NUMBER

SECTION REFERENCE1A101

SIM

1A101

SIM

CLASSROOM101

101

0

KEY NOTE

A1011

SIM

1t

STANDARD ABBREVIATIONS

DEIONIZED WATERDOUBLE JOIST

DEAD LOAD

DAMPPROOFING

DISHWASHER

DOUBLE HUNGDOOR FRAME

DRINKING FOUNTAIN

DEPARTMENTDOUBLE GLAZING

COLD WATER

CABLE TELEVISIONCERAMIC TILE

COUNTERSUNK

COLD ROLLED STEELCIRCUMFERENCE

COMPRESSIBLECOVER PLATE

COORDINATECONTRACTOR

CONSTRUCTIONCONNECTIONCONFERENCE

CONCRETE

CONCRETE MASONRY UNIT

CONTRACT LIMIT LINE

CEILING DIFFUSERCEILING HEIGHT

CENTER LINECONTROL JOINT

CAST IN PLACE

CHALKBOARD

COUNTER FLASHINGCERAMIC TILE

CEMENT PLASTER

CLOSED CIRCUIT TELEVISIONCATCH BASIN

CURB AND GUTTERCENTER TO CENTER

BUILT-UP ROOF

BEARING PLATE

BRIDGING JOIST

BASE PLATE

BELOW FINISH FLOORBACKFLOW PREVENTER

BOTH FACES

BOTTOM OF CURBBULLETIN BOARD

BALLED AND BURLAPPED

AUDIO VISUALASYMMETRICAL

ABOVE SUSPENDED CEILING

ARCHITECT (URAL)

ACCESS PANEL

ANNUNCIATOR

AIR HANDLING UNIT

ABOVE FINISHED SLABABOVE FINISHED GRADEABOVE FINISHED FLOOR

ACCESS FLOOR

ADJUSTABLE

AUTOMATIC DOOR CLOSERAREA DRAIN

ACOUSTICAL TILE

ACOUSTICAL INSULATION

ACOUSTICAL PLASTERACOUSTICAL PANEL

ACID-RESISTANTAIR CONDITIONING

ABBREVIATE

ARCHITECT/ENGINEER

DOOR CLOSURE

DVTL

DWGDW

DRCLSR

DST

DUPL

DS

DT

DMPFDNDODR

DISTDIVDIWDJDL

DIM

DFRDH

DF

CUR

DETDEPTDBL GLZCW

CUBCTV

CSWKCT

CRCMF

CSMTCSKCSGCRS

CPRSCOV PL

COORDCONTR

CONC FL

CONSTRCONNCONF

CONCCOMPL

COLCO

CLSR

CNTRCNRCMUCMPST

CLRCLOSCLLCLG HT

CIR

CLGCLG DIFF

CLCJ

CIP

CHKCHFR

CI

CEM PLASCER

CHANCH BD

CFLGCER TILE

CEMCCTVCB

C/C

CAVCABC&G

BUR

BSMTBTM

BW

BRDG JST

BRK

BRZBRSBRKT

BS

BRGBRG PL

BRDG

BLKHD

BRCG

BLST

BP

BM

BLKGBLKBLDGBL

BFBFF

BJTBITUMBFP

BEVBDBCBB

AV

BALBAFB&B

AVE

ASYMASPHASC

ARCH

ANN

APPX

ANTANOD

AP

AMTAMPLAMB

ALT

AGGR

ALM

AHUAHR

ALUM

AFSAFGAFFAF

ACOUS TILE

ACOUS INSUL

ACOUS PLASACOUS PNL

ADC

ADJCADJADDMADDL

AD

ABV

ACOUSACID RESAC

ABBR

A/E

DOVETAIL

DRAWING

DOWNSPOUTDOOR STOPDRAIN TILEDUPLICATE

DITTODOOR

DOWN

LTGLVLLVR

LONG

LT WT

LRGLSLT

LKR RMLLLNTLLOC

LIGHTINGLEVEL

LOUVER

LOCKER ROOMLIVE LOAD

LONGITUDINAL

LIGHTWEIGHT

LARGELUMP SUM

LIGHT

LINTELLOCATION

STAG

STDSTIR

SQINSQYDSSKSS

ST

SPKRSPRTSQFTSQ

LIGHTWEIGHT CONCRETE MASONRY UNIT

HEATING, VENTILATION, AIR CONDITIONING

DISTANCEDIVIDER

DIMENSION

CURRENT

DETAIL

CUBICLE

CASEWORK

LHLHR

LINLIQLKR

LD BRGLDGLFLG

LAB

LCMU

LAVLBLBR

KWYL

KPLKOP

CASEMENT

CASING

CONCRETE FLOOR

COMPLETE

COLUMNCLEANOUT

JC

KOKBJTJST

INV ELJAN

INVINTR

IF

INSULINSTL

INCANDINL

HVAC

HYDHW

HTG

LOAD BEARING

LINEAR FOOT

LEFT HANDLEFT HAND REVERSE

LINOLEUMLIQUID

LOCKER

LANDING

LENGTH

LABORATORYLAVATORY

KICK PLATEKNOCKOUT PANEL

POUNDLUMBER

KEYWAYLEFT

SMLS

SPKLR

SPSPCLSPEC

SK

SLP

SLVSM

SHRSHTHGSHVLSIMSJ

SCRNSDSECT

SGL

KNEE BRACE

JANITOR'S CLOSET

INVERT ELEVATION

KNOCKOUT

JOINTJOIST

JANITOR

INVERTINTERIOR

INSULATIONINSTALLATION

INCANDESCENTINSIDE FACE

HOT WATER

INLET

HYDRANT

HEATING

SALVSBSCSCHSCMU

SRVSRV

RO

RFM

RNDRHRRHRFG

RESILREQDREMREINF

SPEAKERSUPPORT

SQUARE FOOT

SQUARE INCHSQUARE YARDSERVICE SINK

STAINLESS STEEL

STAGGERED

STANDARDSTIRRUP

STREET

SQUARE

STORM DRAIN

SHEATHING

SLIP JOINT

SHEET METALSEAMLESS

SPECIFICATIONSPRINKLER

SPACINGSPECIAL

SINK

SLOPE

SLEEVE

SHOWER

SHELVESSIMILAR

SCREEN

SECTION

SINGLE

SALVAGESPLASH BLOCK

SOLID CORESCHEDULE

SOLID CONCRETE MASONRY UNIT

REVERSEROOF VENT

ROUGH OPENING

RIGHT HAND REVERSERIGHT HAND

RESILIENTREQUIRED

REMOVABLEREINFORCEMENT

RECESSED FLOOR MAT

SOUTH

ROUND

ROOFING

OWNER FURNISHED-OWNER INSTALLED

OWNER FURNISHED/CONTRACTOR INSTALLHOLLOW CONCRETE MASONRY UNIT

GLAZED CONCRETE MASONRY UNIT

GROUND FAULT INTERRUPTERGENERAL CONTRACTOR

CLOSURE

COUNTERCORNER

COMPOSITE

CLEARCLOSET

CIRCLE

CEILING

CAST IRONCHECK

CHAMFER

HOHORIZ

HSBHSHR

HNDRLHMFHMDHM

HDJT

HDWD

HDBD

HGT

HDR

HCMUHD

HC

HB

CERAMIC

CHANNEL

CEMENT

CAVITYCABINET

BOTH WAYS

BASEMENTBOTTOM

GRTG

GYP PLAS

H&CWH

GYP

GR BMGPDW

GR

GND

GENL CONTR

GL BLK

GLZ CMU

GLU LAMGLZ

GL

GDRL

GFI

GENL

HIGH STRENGTH BOLTHIGH STRENGTH

HORIZONTALHOLD-OPEN

HAND RAILHOLLOW METAL FRAMEHOLLOW METAL DOOR

HOLLOW METAL

HOUR

HARDWOOD

HARDBOARDHEAD JOINT

HEAVY DUTY

HOLLOW CORE

HOSE BIBB

HEIGHT

HEADER

REC

REFRECTRECPTRECD

RDRCPRCRBR

QT

RADRQUALQTY

PWRPVMTPVGPVC

HOT AND COLD WATER

GYPSUM PLASTER

GRADE BEAMGYPSUM DRY WALL

GRATING

HIGH

GYPSUM

GRADE

GROUND

GLUE LAMINATEDGLASS BLOCK

GUARD RAIL

GLAZING

GLASS

GENERAL

PRELIM

PTN

PT

PROJPRKG

PREFABPRPOS

PLBGPLYWD

POLYISOPOLYPOL

PLATPLASPLAM

PL

FIRE EXTINGUISHER CABINET

BRICK

BOTH SIDESBRONZE

BRASSBRACKET

BEARINGBRIDGING

BULKHEAD

BRACING

BALLASTBEAM

BLOCKINGBLOCK

BUILDINGBASE LINE

FURR

GALVGB

FXTRFUT

FSTNRFTG

FSPFS

FOS

FRNTFRMFPRFFPL

FLUORFLT GL

FOMFOC

BED JOINTBITUMINOUS

BEVELBOARD

BALANCEBAFFLE

AVENUE

ASPHALT

FLG

FLR FINFLR PLFLR SKFLR

FLDG

FIN FL

FLFIN

FD

FIN GRFGL

FECFDN

F BRK

FBDF/F

EXTN

GRAB BARGALVANIZED

FIRE STANDPIPE

FURRING

FIXTUREFUTURE

FOOTINGFASTENER

FULL SIZE

FIREPROOFINGFIREPLACE

FACE OF STUDFACE OF MASONRY

FACE OF CONCRETEFLUORESCENT

FLOAT GLASS

FRONTFRAME

PERIM

PHPGBD

PERPPERM

PERFPEDPCPPC

OXY

PBDPBPARGPAR

OVHD

ORIGOPT

FLOOR FINISHFLOOR PLATE

FLOOR SINK

FINISH FLOOR

FLANGEFLOOR

FOLDING

FLASHINGFINISH

FINISH GRADEFIBERGLASS

FOUNDATIONFLOOR DRAIN

FIBERBOARDFACE TO FACE

FIRE BRICKEXTENSION

OFCI

OPPOPNG

OFOIOFF

OF

ODOCOA

NO

O/ONTSNSNOM

NICNFNEGN/A

X SECTWWMWTRPRFWTRWTWSCTWSWRWLDWLWHSE

REFERENCERECTANGULAR

RECEPTACLERECEIVED

RECESSEDROOF DRAIN

REINFORCED CONCRETE PIPEREINFORCED CONCRETE

QUANTITYQUARRY TILE

PAVEMENT

POLYVINYL CHLORIDE

RUBBER

RADIUSRISER

QUALITY

POWER

PAVING

PARTITION

PROJECT

PRELIMINARYPREFABRICATED

POLYSTYRENEPOLISHEDPLYWOODPLUMBINGPLATFORM

PLASTERPLASTIC LAMINATE

POLYISOCYANURATE

PAINT

PARKING

PAIRPOSITIVE

PLATE

CROSS SECTIONWELDED WIRE MESH

WATERPROOFING

WAINSCOTWEATHERSTRIPPING

WATER RESISTANTWELDED

WIND LOADWAREHOUSE

WATERWEIGHT

WHWGL

WFWDW

WD

WC

W/OW/WW/VWCVTVRVOLVNRVIBVESTVERT

VCTVB

VAVVAC

UTILURUPSUNOUNFINUNEXULT

UGUFD

TYPTV

TSTRNBKL

PEGBOARD

PERPENDICULARPERMANENTPERIMETER

PERFORATEDPEDESTAL

PORTLAND CEMENT PLASTERPORTLAND CEMENT

PARTICLE BOARDPANIC BAR

PARALLEL

OVERHEAD

ORIGINALOPTIONAL

PHASE

W

OXYGEN

PARGING

OPPOSITE

OUTSIDE FACE

OUTSIDE DIAMETERON CENTER

OVERALLOUT TO OUT

NOT TO SCALENEAR SIDE

NOT IN CONTRACTNEAR FACE

NEGATIVENOT APPLICABLE

OPENING

OFFICE

V

NUMBERNOMINAL

VINYL WALL COVERING

WALL HUNGWIRE GLASS

WIDE FLANGE

WATER CLOSET

WITHOUTWALL TO WALL

WOOD

WINDOW

WEST

VINYL TILEVAPOR RETARDER

VOLUMEVENEER

VIBRATIONVESTIBULE

VERTICAL

WITH

VINYL COMPOSITION TILE

VARIABLE AIR VOLUME

UNINTERRUPTIBLE POWER SUPPLYUNLESS NOTED OTHERWISE

VINYL BASE

VACUUMVOLT

UTILITYURINAL

UNFINISHEDUNEXCAVATED

ULTIMATE

UNDERGROUNDUNDER FLOOR DUCT

TYPICALTELEVISION

TENSILE STRENGTHTURNBUCKLE

EXPANDED POLYSTYRENE

APPENDIX

ANTENNAANODIZED

AMOUNTAMPLIFIER

AMBIENT

ALTERNATE

AGGREGATE

ALARM

ALUMINUM

ANCHOR

EXH FN

EXST GR

EXSP

EXT

EXP

EXH HD

EXCEWEST

EQUIP

ESCALERECTEQUIV

ESMT

EQL SP

EP

EQ

EPS

ADJACENT

ADDENDUMADDITIONAL

ABOVE

ACOUSTICAL

ENAM

ENGR

EOENTR

ENCL

EMER SHREMER

ELECEL

DWTR

EJ

EXG

EF

E

DWRDWL

EXISTING GRADE

EXPANSIONEXHAUST FAN

EXHAUST HOOD

EXCAVATE

EXTERIOR

EXPOSED

EACH WAYESTIMATE

ESCALATOR

EQUIVALENTEQUIPMENT

EQUALLY SPACED

ELECTRICAL PANEL

EASEMENT

ERECTION

EQUAL

MTR

NMVBLMULTMULL

MTG

MTDMODMO

MISC

MLWKMLDGMLC

MK

MIR

MH

MFGMFR

ELECTRICAL OUTLET

ENCLOSURE

EMERGENCY SHOWEREMERGENCY

ELECTRICALELEVATION

ENAMEL

ENTRANCEENGINEER

EXPANSION JOINT

EACH FACE

DUMBWAITER

EXISTING

EAST

DRAWERDOWEL

MECH

MEZZMEMBMED

MDO

MC

MBR

MAXMATLMASMARBMAINT

STRUCT STL

TOWTOTTOSTOL

TNL

TMPDTMPD GL

TKBD

TOJ

THRUTHRESTHK

TOFFTOF

TERTEMPTECH

TDTCTB-xx

T&GT&B

SYMMSYM

SUSPSUSP CLG

SURFSUPPL

MOVABLEMULTIPLE

MOUNTED

MASONRY OPENINGMILLWORK

MOLDINGMETAL LABORATORY CASEWORK

MISCELLANEOUS

MANHOLE

MANUFACTURINGMANUFACTURER

MORTAR

NORTH

MULLION

MEETING

MODULE

MARK

MIRROR

MEZZANINEMEMBRANE

MECHANICAL

MOMENT CONNECTION

MATERIALMASONRY

MAINTENANCE

MEDIUM DENSITY OVERLOAD

MEDIUM

MEMBER

MAXIMUM

MARBLE

TOP OF FINISH FLOOR

TOP OF WALL

TOP OF STEELTOLERANCE

TEMPERED

TOP OF JOIST

TOP OF FLANGE

TOTAL

TUNNELTEMPERED GLASS

TACKBOARDTHROUGH

THRESHOLD

TERRAZZOTEMPORARY

TECHNICAL

TRENCH DRAIN

THICK

TEST BORING-xx(E.G. TB-1)

TONGUE AND GROOVE

TOP OF CURB

TOP AND BOTTOM

SYMMETERICALSYMBOL

SUSPENDEDSUSPENDED CEILING

SURFACE

STRUCTURAL STEELSUPPLEMENT

M

LW PLASLWC

STL JSTSTL PLSTL

STORSTRUCT

LIGHTWEIGHT PLASTERLIGHTWEIGHT CONCRETE

METER

STEEL JOISTSTEEL PLATE

STORAGESTRUCTURAL

STEEL

ANCHOR BOLTAB

ACTUALACT

ALD ALUMINUM DOOR

ACOUSTICAL PANEL CEILINGAPC

ASBESTOSASB

AWC ACOUSTICAL WALL COVERINGAWP ACOUSTICAL WALL PANEL

BO BOTTOM OFBOC BACK OF CURBBOW BOTTOM OF WALL

CORNER GUARDCG

COMM COMMERCIAL

CORRIDORCORR

CARPETCPT

DRAPERY FABRICDF

DIAMETERDIA

DRAPERY LINERDL

DR DRAIN

EA EACH

ELEV ELEVATOR

EPOXY FLOOREPX

EXST EXISTING

EIFS EXTERIOR INSULATION FINISH SYSTEM

FC FIRE COATED

FACTORY FINISHFFFINISH FLOOR ELEVATIONFFE

FL FLOWLINE

GUT GUTTER

HC HANDICAP

HLB HORIZONTAL LOUVER BLINDS

ID INSIDE DIAMETER

LIN LINEAR

MB MARKERBOARD

MC METAL CLAD

MDF MEDIUM DENSITY FIBERBOARD

ME MATCH EXISTINGME MISCELLANEOUS EQUIPMENT

MIL MILLIMETERMIN MINIMUM

ML MATCH LINEML METAL LATH

MTL METAL

OD OVERFLOW DRAIN

OVERHEAD DOOROHDOPERABLEOPER

OTA OPEN TO ABOVEOTFA OPEN TO FLOOR ABOVEOTS OPEN TO STRUCTURE

OZ OUNCEP/C PRECAST

PF PANEL FABRICPFP PRE-FINISHED PANEL

PL PLASTIC LAMINATE

PS PROJECTION SCREEN

PCT PORCELAIN TILE

RB RUBBER BASE

RST RUBBER STAIR TREADRT RUBBER TILE

S SEATING

SF SYSTEMS FURNITURE

SLA SLATE

SLS SUB-FLOOR LEVELING SYSTEM

SSM SOLID SURFACING MATERIALST STAIN

STC SOUND TRANSMISSION CLASS

STN STONE

SVB SHEET VINYL BASESVF SHEET VINYL FLOOR

SYST SYSTEM

T TABLETB TACKBOARD

TE TRANSITION EDGE

TLT TOILET

TO TOP OF

TS TUBE STEEL

UF UPHOLSTERY FABRIC

UL UNDERWRITERS LABORATORY

VB VAPOR BARRIER

VDB VISUAL DISPLAY BOARD

WC WALL COVERINGWCPT WALL CARPET

WDD WOOD DOOR

WF WOOD FLOORING

WH WATER HEATER

GENERAL NOTES1.

2.

3.

ALL DISCIPLINES SHALL BE RESPONSIBLE FOR THEIR SCOPE OF WORK. THIS WORK IS TO BE SCHEDULED AND COMPLETED WITH THE GENERAL CONTRACTOR'S FULL KNOWLEDGE.

ALL DIMENSIONS LOCATING PLUMBING FIXTURES ARE FROM FINISH MATERIAL NOT FROM GPDW SHEATHING.

FINAL CLEANING - REMOVE OR REPAIR DAMAGED OR SOILED SPOTS ON NEWLY PAINTED WALLS AND ON ALL NEWLY INSTALLED WORK. REMOVE DUST AND DEBRIS FROM ALL NEW WORK.

A101 1SI

M

A101 1

001A

REVISION TAG INFORMATION:

BOTTOM indicates consecutive number assigned to instrument type.

TOP indicates the instrument type.ABDFGILPR

= Addendum= Bid Package= Construction Change Directive or Change Directive= Field Order= Guaranteed Maximum Price= Architects Supplemental Instructions or Architects Supplemental Information= Limited Permit= Proposal Request, Proposal Request Order or Change Proposal Request= Request For Information

DETAIL SECTION REFERENCE1/A101

SIM

FS FLAT SCREENFS FAR SIDE

UDRLMNT UNDERLAYMENTUDR UNDER

CONT CONTINUOUS

# SHEET HISTORY:?

? - #

Lincoln, Nebraska1010 Lincoln Mall, Suite 200Lincoln, NE 68508-2883402 477.9291 Fax 402 477.6542

Kansas City, MissouriFairway, Kansas

Landscape Architecture

www.clarkenersen.com

Architecture

EngineeringInteriors

Plot

Tim

e St

amp:

File

Loca

tion/

Nam

e:

ISSUED

5/24

/201

8 4:

25:1

5 PM

C:\

(1) R

evit

Proj

ects

\201

7\11

9001

-A-1

7_tim

.roge

rs@

clar

kene

rsen

.com

.rvt

Title Sheet & DrawingIndex

G0.00

TCEP No.: 119-001-17

152 S Columbia Rd.Seward, NE

LCMS NE District Office

May 7, 2018

05/07/18 AS PER CONSTRUCTION DOCS

A0.00 Wall Type Schedule & DetailsA0.10 Demolition PlansA1.10 Lower Level Floor PlanA1.11 First Level Floor PlanA2.10 Exterior Elevations & Reflected Ceiling PlansA3.10 Stair Sections, Door Schedule, Door Types, & Frame TypesA4.10 Interior Elevations & Restroom Schedule

GENERALLCMS Nebraska District Office Remodel

152 S Columbia Rd, Seward NE 68434119-001-17May 7, 2018

LANDSCAPE ARCHITECTURAL

ARCHITECTURAL

INTERIOR FINISHES

MECHANICAL

ELECTRICAL

G0.00 Title Sheet & Drawing IndexG0.10 Code Compliance Plans

L1.01 Site Conditions/SiteDemolition Plan

L2.01 Site Materials PlanL2.02 Site Layout PlanL3.01 Site Grading PlanL4.01 Site Planting PlanL5.01 Site Irrigation PlanL6.01 Site Details

F1.10 Lower Level Finishes Plan and Finish Materials ScheduleF1.11 First Floor Finishes PlanF2.10 Signage Plans, Details & Schedule

M0.00 Mechanical Abbreviations, Symbols & NotesM0.01 Lower Level Mechanical Demolition PlanM0.02 First Floor Mechanical Demolition PlanM0.03 Mechanical Roof Demolition PlanM1.01 Lower Level HVAC PlanM1.02 First Floor HVAC PlanM1.03 Mechanical Roof PlanM2.01 Underfloor Lower Level Piping PlansM2.02 Lower Level Pipnig PlanM2.03 First Floor Piping PlanM3.01 Piping Riser DiagramsM4.01 Mechanical Room PlansM5.01 Mechanical DetailsM6.01 Mechanical Schedules

E0.00 Electrical Abbreviations, Symbols Legend & General NotesE0.01 Electrical Site Utilities PlanE0.02 Lower Level & First Floor Electrical Demolition PlanE1.10 Lower Level & First Floor Lighting PlanE2.10 Lower Level, First Floor & Roof Power & Auxiliary Systems PlanE3.01 Electrical One Line Diagram, Details & SchedulesE4.01 Electrical Schedules

ELECTRICAL ENGINEERMECHANICAL ENGINEERLANDSCAPE ARCHITECTARCHITECT(COORDINATING PROFESSIONAL)

A - 001 05/15/2018 ADDENDUM 001A - 003 05/25/2018 ADDENDUM 003

CIVIL ENGINEER

003A

C1.01 Sanitary Sewer PlanCIVIL

003A

Page 4: ADDENDUM NO. 3 - clarkenersen.com No. 3 with... · sm shr shthg shvl sim sj scrn sd sect sgl knee brace janitor's closet invert elevation knockout joint joist janitor invert interior