addendum #2 nwit-16-10 supply and install sports field ...€¦ · exist. concession stand 1-53mm...
TRANSCRIPT
June 17, 2016
ADDENDUM #2
NWIT-16-10 Supply and Install Sports Field Lighting
Moody Park, New Westminster, BC
This addendum modifies the Invitation to Tender only as noted: DRAWINGS <ADD> Drawing 5184-16-01 of 03 Revision B – Contractor may use alternate conduit routing for TELUS conduit as shown on drawing (1 page attached) Please acknowledge this addendum on page 2 of 3 in the Bid Form. END OF ADDENDUM #2 Yours truly,
Heather M. Rossi Intermediate Buyer
Document #891360
TT
MO
OD
Y P
AR
K
5184-16-01 of 03
FEB
RU
AR
Y 15, 2016
1:500
B1 of 3
600 8th Street, N
ew W
estminster, B
C V
3M 3S
2C
ity of New
Westm
inster Parks D
epartment
NE
W W
ES
TMIN
STE
R, B
C
SP
OR
TS LIG
HTIN
G A
ND
PO
WE
R D
ISTR
IBU
TION
CH
K'D
DA
TER
EV
ISIO
NB
YN
o.
CA
NC
EL P
RIN
TS B
EA
RIN
G P
RE
VIO
US
LETTE
R
DMD (2010)
DR
AW
ING
RE
FER
EN
CE
PR
OJE
CT N
o.
DE
SIG
NE
D
DR
AW
N
CH
EC
KE
D
DA
TE
SC
ALE
:
SE
AL
RE
VIS
ION
SH
EE
T No.
DM
D &
A
sso
ciates Ltd
.
#12-17358 104A A
venueS
urrey, BC
, Canada V
4N 5M
3w
ww
.dmdeng.com
office@dm
deng.com604/589-9010
Fax 604/589-9012
DJW
2016-03-08IS
SU
ED
FOR
RE
VIE
WK
GS
A
FOR
CO
NS
TRU
CTIO
N2016-05-03
CO
NTR
AC
TOR
SH
ALL C
ON
FIRM
ON
SITE
PR
IOR
TO C
ON
STR
UC
TION
THA
T PO
LES
& E
QU
IPM
EN
T WILL M
EE
T WorkS
afeBC
CLE
AR
AN
CE
RE
QU
IRE
ME
NTS
FOR
OV
ER
HE
AD
PR
IMA
RY
AN
D S
EC
ON
DA
RY
LINE
S.
CO
NTR
AC
TOR
TO R
EP
OR
T AN
Y C
ON
FLICTS
OR
DIS
CR
EP
AN
CIE
STO
DM
D &
AS
SO
CIA
TES
LTD.
CH
EC
K B
EFO
RE
YO
U D
IG
OV
ER
HE
AD
PO
WE
R LIN
E C
ON
FLICTS
CO
NTR
AC
TOR
SH
ALL R
EFE
R TO
MU
NIC
IPA
L RE
CO
RD
/ CIV
IL DE
SIG
ND
RA
WIN
GS
FOR
ALL O
THE
R U
TILITIES
, SE
RV
ICE
LOC
ATIO
NS
, AN
DD
ETA
ILS. TH
E E
XA
CT LO
CA
TION
OF TH
ES
E U
TILITIES
SH
ALL B
ED
ETE
RM
INE
D O
N S
ITE B
Y TH
E C
ON
TRA
CTO
R.
CO
NTR
AC
TOR
TO R
EP
OR
T AN
Y C
ON
FLICTS
OR
DIS
CR
EP
AN
CIE
STO
DM
D &
AS
SO
CIA
TES
LTD.
LOC
ATIN
G E
QU
IPM
EN
TFO
R C
LAR
ITY C
ON
DU
ITS, JU
NC
TION
BO
XE
S A
ND
PO
LES
MA
Y N
OT B
ES
HO
WN
AT D
ES
IGN
OFFS
ETS
. CO
NTR
AC
TOR
SH
ALL
LOC
ATE
ALL E
QU
IPM
EN
T BA
SE
D O
N S
TATIO
NS
AN
D/O
R O
FFSE
TS A
SN
OTE
D A
ND
SH
ALL N
OT R
ELY
ON
CO
OR
DIN
ATE
S O
BTA
INE
D FR
OM
DM
D D
IGITA
L DR
AW
ING
S. C
ON
TRA
CTO
R TO
RE
PO
RT A
NY
CO
NFLIC
TSO
R D
ISC
RE
PA
NC
IES
TO D
MD
& A
SS
OC
IATE
S LTD
.
A1
B1
C1
C2
B2
A2
T1
T3
P2
P1
P4
P3
EIG
HTH
STR
EE
T
TEN
NIS
CO
UR
TS
BA
SE
BA
LL FIELD
BO
WLIN
G G
RE
EN
#2
BO
WLIN
G G
RE
EN
#1
25S
ITE P
LAN
01:500
V
LEG
EN
D:
PR
OP
OS
ED
GA
LVA
NIZE
D S
TEE
L SP
OR
TS LIG
HTIN
G P
OLE
PR
OP
OS
ED
LIGH
TING
CO
NTR
OL C
AB
INE
T
PR
OP
OS
ED
LAR
GE
RO
UN
D P
LAS
TIC P
ULL B
OX
C/W
SE
CU
RITY
LID
PR
OP
OS
ED
UN
DE
RG
RO
UN
D R
PV
C C
ON
DU
IT AN
D C
ON
DU
CTO
RS
120/240V (S
IZE A
ND
No. A
S N
OTE
D)
NO
TES
:
1.A
LL WO
RK
SH
ALL C
ON
FOR
M TO
THE
MO
ST C
UR
RE
NT E
DITIO
N O
F THE
CA
NA
DIA
N E
LEC
TRIC
AL C
OD
E C
.S.A
.-C22.1 A
ND
AN
YB
ULLE
TINS
ISS
UE
D B
Y TH
E E
LEC
TRIC
AL S
AFE
TY B
RA
NC
H, A
ND
THE
MM
CD
PLA
TINU
M B
OO
K &
SU
PP
LEM
EN
TAL
SP
EC
IFICA
TION
S.
2.ID
EN
TIFY A
LL CIR
CU
ITS IN
ALL JU
NC
TION
BO
XE
S, TE
RM
INA
L BLO
CK
IN S
ER
VIC
E C
AB
INE
T, AT TH
E D
ISC
ON
NE
CT B
RE
AK
ER
INTH
E S
PO
RTS
LIGH
TING
BA
LLAS
T BO
X, A
ND
SE
CU
RITY
LIGH
TING
CIR
CU
ITS IN
THE
PO
LE H
AN
DH
OLE
WITH
SLE
EV
E TY
PE
WIR
EM
AR
KE
RS
. EA
CH
FEE
DE
R S
HA
LL BE
LAB
ELE
D W
ITH TH
E C
IRC
UIT N
o. (I.E. C
CT1, C
CT3, C
CT5, E
TC.)
3.A
LL CO
ND
UC
TOR
S S
HA
LL BE
ALC
AN
NU
AL W
IDE
STR
IPE
RW
90 OR
NU
AL FE
ED
ER
PLE
X H
S R
W90 (U
NLE
SS
OTH
ER
WIS
E N
OTE
D).
SP
OR
TS LIG
HTIN
G C
ON
DU
CTO
RS
SH
ALL R
UN
CO
NTIN
UO
US
WITH
NO
SP
LICE
S.
4.C
ON
TRA
CTO
R S
HA
LL EX
CA
VA
TE FO
UN
DA
TION
AN
D G
AIN
AP
PR
OV
AL FR
OM
GE
OTE
CH
NIC
AL E
NG
INE
ER
PR
IOR
TOFO
UN
DA
TION
INS
TALLA
TION
. BA
CK
FILL SH
ALL M
EE
T THE
AP
PR
OV
AL O
F THE
GE
OTE
CH
NIC
AL E
NG
INE
ER
.
5.A
TRO
N H
EB
SE
RIE
S W
ATE
R-R
ES
ISTA
NT FU
SE
HO
LDE
R C
/W A
10A B
US
S K
TK 10 FU
SE
& 2 IN
SU
LATIN
G B
OO
TS S
HA
LL BE
INS
TALLE
D IN
EA
CH
SE
CU
RITY
LUM
INA
IRE
LIVE
CO
ND
UC
TOR
, IN TH
E H
AN
DH
OLE
.
6.P
RIO
R TO
FINA
L INS
PE
CTIO
N C
ON
TRA
CTO
R S
HA
LL EN
SU
RE
THA
T THE
EN
TIRE
ELE
CTR
ICA
L SY
STE
M IS
FULLY
FUN
CTIO
NA
LA
ND
THA
T SU
BS
TAN
TIAL C
OM
PLE
TION
HA
S B
EE
N O
BTA
INE
D.
7.C
ON
TRA
CTO
R S
HA
LL RE
PLA
CE
ALL A
SP
HA
LT & C
ON
CR
ETE
RE
MO
VE
D FO
R TH
E IN
STA
LLATIO
N / R
EM
OV
AL O
F THE
ELE
CTR
ICA
L AN
D LIG
HTIN
G E
QU
IPM
EN
T.
8.A
LL TER
MIN
ATIO
NS
SH
ALL B
E D
UA
L RA
TED
CU
/AL. A
LL ALU
MIN
UM
-ALU
MIN
UM
AN
D A
LUM
INU
M-C
OP
PE
R C
ON
DU
CTO
RC
ON
NE
CTIO
NS
AR
E TO
BE
CO
MP
LETE
D W
ITH H
-TAP
CO
MP
RE
SS
ION
TYP
E C
ON
NE
CTO
RS
(BLA
CK
BU
RN
TYP
E W
R O
RA
PP
RO
VE
D E
QU
AL) . C
ON
NE
CTIO
NS
SH
ALL B
E C
OM
PLE
TED
WITH
A B
LAC
KB
UR
N O
D581 M
AN
UA
L CO
MP
RE
SS
ION
TOO
L WITH
AP
PR
OP
RIA
TE C
ON
NE
CTO
R D
IE O
R A
PP
RO
VE
D E
QU
IVA
LEN
T. WR
AP
CO
ND
UC
TOR
S A
ND
SP
LICE
S W
ITH S
ELF FU
SIN
GR
UB
BE
RIZE
D TA
PE
AN
D C
OM
PLE
TELY
CO
VE
R R
UB
BE
RIZE
D TA
PE
WITH
PV
C TA
PE
. ALL A
LUM
INU
M C
ON
NE
CTIO
NS
AR
E TO
HA
VE
"PE
NE
TRO
X" E
LEC
TRIC
AL JO
INT C
OM
PO
UN
D.
9.C
OM
MU
NIC
ATIO
NS
RE
-CO
NN
EC
TION
TO TH
E C
EN
TUR
Y H
OU
SE
AN
D LA
WN
BO
WLIN
G FA
CILITY
TO B
E C
OO
RD
INA
TED
BY
THE
CITY
/CO
NTR
AC
TOR
WITH
TELU
S.
10.A
NY
EX
CA
VA
TION
UN
DE
RTA
KE
N W
ITHIN
THE
DR
IPLIN
E O
F THE
TRE
ES
SH
ALL B
E U
ND
ER
TAK
EN
WITH
A V
AC
UU
M TR
UC
K A
ND
AIR
SP
AD
E TO
PR
EV
EN
T DA
MA
GE
TO TH
E TR
EE
S A
ND
RO
OTS
. EX
CA
VA
TION
SH
ALL B
E D
ON
E U
ND
ER
THE
SU
PE
RV
ISIO
N O
F ATR
EE
AR
BO
RIS
T. S
UP
PL
IE
D B
Y T
HE
C
ON
TR
AC
TO
R. C
ITY TO
PR
OV
IDE
LIST O
F AP
PR
OV
ED
AR
BO
RIS
TS.
11.A
LL AB
OV
E G
RO
UN
D C
ON
DU
IT SH
ALL B
E G
ALV
AN
IZED
RM
C.
12.D
RILL B
UILD
ING
WA
LLS FO
R C
ON
DU
IT EN
TRY
. SE
AL A
LL HO
LES
WITH
GR
OU
T.
13.A
LL OP
EN
ING
S IN FLO
OR
S A
ND
WA
LLS FO
R E
LEC
TRIC
AL S
YS
TEM
S CO
ND
UITS
, DU
CTS
, CA
BLE E
TC., S
HA
LL BE
SE
ALE
D W
ITHFIR
E S
TOP
PIN
G M
ATE
RIA
L AFTE
R FIN
AL IN
STA
LLATIO
N O
F THE
SY
STE
MS
.
14.FIR
E S
TOP
PIN
G S
HA
LL BE
THO
MA
S &
BE
TTS, "FLA
ME
-SA
FE" O
R D
OW
CO
RN
ING
"FIRE
STO
P" FIR
E R
ETA
RD
AN
T, DE
SIG
NE
D A
ND
INS
TALLE
D TO
SU
IT THE
AP
PLIC
ATIO
N; IN
STA
LLED
PE
R M
AN
UFA
CTU
RE
RS
INS
TRU
CTIO
NS
AN
D TH
E FIN
AL IN
STA
LLATIO
NS
HA
LL BE
IN FU
LL CO
NFO
RM
AN
CE
TO B
UILD
ING
STA
ND
AR
DS
.
C
PR
OP
OS
ED
CO
ND
UIT S
TUB
-OU
T AN
CA
P (C
/W P
ULL S
TRIN
G, S
IZE A
S N
OTE
D)
S1
PO
LE N
UM
BE
R
PR
OP
OS
ED
UN
DE
RG
RO
UN
D R
PV
C C
ON
DU
IT AN
D C
ON
DU
CTO
RS
347/600V (S
IZE A
ND
No. A
S N
OTE
D)
2-53mm
RP
VC
(347V)
T2
2-53mm
RP
VC
(347V)
2-103mm
DB
2 (PR
IMA
RY
)C
ON
DU
CTO
RS
BY
CoN
W E
LEC
TRIC
AL
EX
IST. C
oNW
ELE
CTR
ICA
LP
RIM
AR
Y B
OX
(JV121)
3-53mm
RP
VC
(347V)
2-53mm
RP
VC
(347V)
3-78mm
RP
VC
(347V)
4-53mm
RP
VC
(347V)
3-53mm
RP
VC
(347V)
3-53mm
RP
VC
(347V)
2-53mm
RP
VC
(347V)
1-53mm
RP
VC
(347V)
(FRO
M JB
TO TO
PO
LE) TY
P.
12-78mm
RP
VC
(347V)
2-53mm
RP
VC
(347V)
CoNW 3Ø (x410) 300kV
A 347/600V
TRA
NS
FOR
ME
R, C
ON
CR
ETE
PA
D,
CO
UN
TER
PO
ISE
GR
OU
ND
ING
CoNW 1Ø (x411) 50kV
A 120/240V
TRA
NS
FOR
ME
R, C
ON
CR
ETE
PA
D,
CO
UN
TER
PO
ISE
GR
OU
ND
ING
LIGH
TING
CO
NTR
OL K
IOS
K
6-53mm
RP
VC
(347V)
3-78mm
RP
VC
(347V)
2-53mm
RP
VC
(347V)
V
1-53mm
RP
VC
(347V)
EX
IST. LA
WN
BO
WLIN
G LIG
HTIN
GR
EM
OV
E: LU
MIN
AIR
E, P
OLE
,C
ON
DU
CTO
RS
AN
D D
ISC
AR
DO
FF-SITE
(TYP
. FOR
16). CU
T OFF
PO
LE 150m
m B
ELO
W G
RA
DE
&R
EFIN
ISH
AS
PE
R E
XIS
T. SU
RFA
CE
EX
IST. S
PO
RTS
FIELD
LIGH
TING
RE
MO
VE
: LUM
INA
IRE
, PO
LE, C
ON
CR
ETE
BA
SE
,C
ON
DU
CTO
RS
AN
D D
ISC
AR
D O
FF-SITE
AB
AN
DO
N: C
ON
DU
IT(TY
P. FO
R 8)
KE
NT S
CO
TT
LINA
EL G
AR
AW
AN
Y
DA
NIE
L J. WO
NG
1-78mm
DB
2 (SE
CO
ND
AR
Y 120/240V
)
1-78mm
DB
2 (SE
CO
ND
AR
Y 120/240V
)
1-78mm
DB
2 (SE
CO
ND
AR
Y 120/240V
)
2-103mm
DB
2 (SE
CO
ND
AR
Y 347/600V
)
PR
OP
OS
ED
SE
CU
RITY
LIGH
T ON
SP
OR
TS P
OLE
2-53mm
RP
VC
(347V)
1-53mm
RP
VC
STU
B-U
PN
EX
T TO P
OLE
AN
D C
AP
(FOR
FUTU
RE
PA
SY
STE
M)
EX
IST. B
AS
EB
ALL
FIELD
HO
US
E
EX
IST. C
ON
CE
SS
ION
STA
ND
1-53mm
RP
VC
STU
B-U
PN
EX
T TO P
OLE
AN
D C
AP
(FOR
FUTU
RE
PA
SY
STE
M)
1-53mm
RP
VC
(120/240V)
1-53mm
RP
VC
(120/240V)
2-78mm
RP
VC
(120/240V)
EX
IST. LA
WN
BO
WLIN
GC
LUB
HO
US
E
1-53mm
RP
VC
(120/240V)
PU
SH
BU
TTON
& S
TRO
BE
C/W
SIG
N O
N FE
NC
E P
OS
T WH
ICH
RE
AD
S "P
US
H B
UTTO
N TO
AC
TIVA
TE LIG
HTIN
G. LIG
HTIN
GW
ILL TIME
OU
T AN
D N
EE
DS
TO B
ER
E-A
CTIV
ATE
D FO
R S
AFE
PLA
Y".
2-27mm
RP
VC
& R
MC
(120/240V)
ALL FIE
LD W
IRIN
G S
HA
LL BE
ALU
MIN
UM
CA
BLE
(UN
LES
S O
THE
RW
ISE
SP
EC
IFIED
)
CoN
W E
LEC
TRIC
AL
PR
IMA
RY
BO
X (JV
203)
2-103mm
DB
2 (PR
IMA
RY
)C
ON
DU
CTO
RS
BY
CoN
W E
LEC
TRIC
AL
1-78mm
DB
2 (PR
IMA
RY
)C
ON
DU
CTO
RS
BY
CoN
W E
LEC
TRIC
AL
LIGH
TWE
IGH
T SE
RV
ICE
BO
X(TO
CoN
W S
TAN
DA
RD
S)
1-53mm
RP
VC
(120/240V)
(FRO
M JB
TO TO
PO
LE) TY
P.
12.5m
10.2m
9.5m
42.4m
25.7m
70.4m
72.17m25.5m
42.5m
8.6m
15.0m
13.1m
13.0m (TY
P. FO
R 3)
24.5m(TYP. FOR 3)
41.0m(TYP. FOR 4)
RE
MO
VE
: SK
YLO
GIX
KE
YP
AD
3-53mm
RP
VC
(347V)
CO
MM
ON
TRE
NC
H (TY
P.)
78mm
RP
VC
CO
MM
.
RE
MO
VE
: PO
WE
R &
TELU
S C
ON
DU
CTO
RS
17.0m (TY
P. FO
R 2
ON
EA
ST S
IDE
)
RE
MO
VE
: PO
WE
RC
ON
DU
CTO
RS
SP
OR
TC
OU
RT
CO
MM
ON
TRE
NC
H (TY
P.)
C
C
EX
IST. TE
LUS
MA
NH
OLE
RU
N TO
WE
ST C
OR
NE
R O
F EIG
HTH
STR
EE
T AN
D 6TH
AV
EN
UE
& R
EM
OV
E TE
RA
SP
AN
SP
LICE
EN
CLO
SU
RE
. INS
TALL N
EW
TYP
E C
JUN
CTIO
N B
OX
IN C
ON
CR
ETE
.M
AIN
TAIN
EX
IST. FIB
RE
& S
PLIC
ES
PR
OP
OS
ED
CO
MM
. JUN
CTIO
N B
OX
(MO
TI SP
EC
SP
635 - 1.3.1 & 1.3.2) W
ITH LID
LAB
LED
"CO
MM
" OR
"TELU
S"
VP
RO
PO
SE
D V
AU
LT (MoTI S
P635 - 1.3.3 &
1.3.4)
INS
TALL 53m
m R
MC
ON
BU
ILDIN
GFA
CE
TO E
XIS
T. WE
ATH
ER
HE
AD
.R
EM
OV
E: W
EA
THE
RH
EA
D A
ND
INS
TALL: LB
CO
ND
UIT TO
TIEIN
TO B
UILD
ING
78mm
RP
VC
(TEL)
CO
ND
UC
TOR
S B
Y TE
LUS
78mm
RP
VC
(TEL)
CO
ND
UC
TOR
S B
Y TE
LUS
78mm
RP
VC
(TEL)
CO
ND
UC
TOR
S B
Y TE
LUS
78mm
RP
VC
(TEL)
CO
ND
UC
TOR
S B
Y TE
LUS
3-53mm
RP
VC
(347V)
RE
MO
VE
: EX
IST. W
EA
THE
RH
EA
DIN
STA
LL: GA
LVA
NIZE
D JU
NC
TION
BO
X O
N W
ALL
EX
IST. S
PO
RT
CO
UR
T LIGH
TING
2-103mm
DB
2 (PR
IMA
RY
) STU
B-O
UT
EX
TEN
D: C
ON
DU
IT AN
DC
ON
DU
CTO
RS
TO N
EW
JUN
CTIO
NB
OX
AN
D C
ON
NE
CT IN
CA
BIN
ET
'T' RE
FER
EN
CE
PO
INT
'A', 'B
' AN
D 'C
'R
EFE
RE
NC
E P
OIN
T
EX
IST. P
OS
T TOP
LIGH
TING
EX
IST. P
OS
T TOP
LIGH
TING
1-78mm
DB
2 (SE
CO
ND
AR
Y 120/240V
)
'P' R
EFE
RE
NC
E P
OIN
T
EX
IST. C
EN
TUR
Y H
OU
SE
PR
OP
OS
ED
RP
VC
CO
MM
UN
ICA
TION
CO
ND
UIT (S
IZE A
ND
No. A
S N
OTE
D)
CO
ND
UIT A
ND
JUN
CTIO
N B
OX
FOR
FUTU
RE
BA
SE
BA
LL FIELD
LIGH
TING
DJW
2016-05-03IS
SU
ED
FOR
TEN
DE
RD
MS
BD
ISTR
IBU
TION
VO
LTAG
E IS
: 120/240V
347/600V
ALL IN
FOR
MA
TION
RE
LATIN
G TO
CoN
WE
LEC
TRIC
AL W
OR
K IS
FOR
BID
PU
RP
OS
ES
ON
LY.
ALL C
ON
STR
UC
TION
SH
ALL B
E D
ON
E A
S P
ER
CoN
W E
LEC
TRIC
AL C
ON
STR
UC
TION
DR
AW
ING
S.
KE
Y S
WITC
H A
ND
BO
XFO
R LIG
HTIN
G C
ON
TRO
LS
1-53mm
RP
VC
PA
RK
ING
LOT
LUM
INA
IRE
C/W
PE
C
PO
LE &
LEA
SE
LIGH
T TO R
EM
AIN
RE
MO
VE
: DIP
SE
RV
ICE
15.0m15.9m
C
RE
MO
VE
: EX
IST. TE
RA
SP
AN
SP
LICE
EN
CLO
SU
RE
. INS
TALL N
EW
JUN
CTIO
N B
OX
(TYP
E 5686).
MA
INTA
IN E
XIS
T. FIBR
E &
SP
LICE
S
EX
IST. B
AS
EB
ALL FIE
LD
EX
IST. B
AS
EB
ALL FIE
LD