add new rsu to zte sdr’s
TRANSCRIPT
Add new RSU to ZTE SDR’s
• Scenario:• Adding 1 cascaded RSU60E-GU188• Upgrading 2 TRX’s on WadiElKhalehInters-1.
Prepared By: Mahmoud OmeirPhone Number:- 0788002326Email: [email protected]
- Export the OMCB configuration for the site that needs upgrade as shown in the figure.
- The extracted file will be .XML
- Use ZTE SDR configuration toolkit to convert (.XML) file to excel sheet (.XLS) as shown in the figure.
- ZTE SDR config toolkit is used to convert ZTE SDR’s from XML to XLS and vice versa.
- Note: Use the latest version of this software.
- When the conversion succeeds, you will get this output.
- Open the excel file. Now from Equipment sheet: modify Rack Topology as shown in the below figure in order
to cascade RSU# 3 to RSU#2 as our example.
- RU sheet: Add a new coloumn for the new RSU Specify Board Type Fiber port connection. For cascaded RSU’s both must be
served by the same fiber port as seen from our example below.
- RU(Extension): add a new column for the new RSU and modify RSU
number.
- RU(GSM): Add a new coloumn for the new RSU. Modify RSU number. Set a unique carrier group No. Total carrier number (which in our case 2 TRX’s) Set the serving Sector No(sector 1 in our example) Carrier Number dedicated to first sector = Total carrier
number.
- GSM carrier Add new columns to activate the number of TRX’s in our concerned
RSU that will be known from its carrier group No. in our example we have 2 TRX’s need upgrade, so we need to set
the following: o Sector No.o Logic Carrier Frequency No ( same as TRX number in the logical
sector) o Carrier group number (this number is related to the RSU that will
carry these TRX’s).
• The final step is to include the SDR software version as shown below and the latest software is always recommended.
• Note: if u didn’t do this step the conversion back to XML file is going to encounter a failure.
- Using ZTE SDR configuration toolkit convert the .XLS file back to XML as shown in the figure.
- In order to import the new configuration set; select batch offline reverse and select your new XML file.
- The new config set will be shown under the site name as shown in the figure and will be in offline mode.
- Switch the offline config set to master in order to make it work online.
- Synchornize all tables.
For any more information please don’t hesistate to contact me.
Prepared By: Mahmoud OmeirPhone Number:- 0788002326Email: [email protected]
Thank You & Good Luck