adam-4572 modbus tcp converter modbus rtu to - … ieee 802.3, ieee 802.3u speed 10/100 mbps...
TRANSCRIPT
Page 102 • Flow Instruments • F-19 Kessler-Ellis Products • 800-631-2165
Flow
Inst
rum
ents
CO
MM
UN
ICA
TIO
N S
OLU
TIO
NS
Features• Supports 10/100 Mbps communication speeds• Allowsupto8clientstoaccessfielddata
simultaneously• Supports popular HMI software with Modbus®/
TCP driver or OPC server• Up to 3 Independent serial ports capacity if configuredtoRS-485serialmode
• Providesauto-searchingdeviceIDWindowsutility
• SurgeprotectionforRS-485andpowerline• AutomaticRS-485dataflowcontrol• EasymountingonDIN-railandwall,andcan
also be stacked• SupportsModbus/ASCII,Modbus/RTUProtocol
to control devices
Modbus RTU to Modbus TCP Converter ADAM-4572
Description:ADAM-4572servesasaninterfacebetweenModbus
serialdevicesandcomputerhostsrunningModbus/TCPonanEthernetnetwork.FullycompliantwithModbus/TCP,itisidealforthosewholookingforaneasywaytoconnecttheirexistingdevicesorcontrollersrunningModbusserialprotocols (Modbus/ASCII orModbus/RTU) to Ethernetnetworks. Itworks like a bridgebetweenModbus serialdevices and controllers over TCP/IP Ethernet networks. Benefits are also abundant for customerswhowant toexpand their Ethernet-basedModbus (Modbus/TCP)applications.
Networkshavebecomeincreasinglyvitalforindustrialautomationapplications,butmanycontroldevices todaydo not have a network port and can only communicate with a dedicated local PC or control panel. Advantech’s revolutionarynetwork-enablingtechnologyisnowallowingcontrol devices with serial ports to connect to the Ethernet andsharenetworksquicklyandcost-effectively.TheADAM-4572ModbustoEthernetDataGatewayallowsuserstointegratenewandexistingModbus/RTUandModbus/ASCIIserial devices to newerTCP/IP network-baseddevices.Manufacturers, system integrators, and end users cannowusetheADAM-4572tocreatenetworkedapplicationstoremotelymanageandaccessdatafromcontroldevicesno matter where they are.
specifications:ethernet communicationsCompatibility IEEE802.3,IEEE802.3uSpeed 10/100 MbpsConnectors 1xRJ-45
serial communicationsType RS-232/422/485Connectors Screw terminalPorts 1DataBits 7,8StopBits 1,2BaudRate 300bps~115.2kbpsDataSignals RS-232:TxD,RxD,GND RS-422:TxD+,TxD-,RxD+,RxD-,
GND RS-485:Data+,Data-,GND
protectionSurgeProtection 15kVESD
Kessler-Ellis Products • 800-631-2165 F-19 • Flow Instruments • Page 103
Flow Instrum
entsC
OM
MU
NIC
ATIO
N SO
LUTIO
NS
ST2 - 1 ST2 - 2 ST2 - 3
RS-485 Modbus RTU Network
ADAM-4572
Modbus Ethernet Data Gateway
softwareDriversSupported Windows®98/NT/2000/XPUtilitySoftware Auto-detectingconfigurationutility
(upto128devices)Devicesetting:name,description,serialport
OperationMode Modbus/TCP,Modbus/RTU,Modbus/ASCII
Configuration Configurationutility
MechanicsDimensions (HxWxD)70x130x30mmEnclosure ABS+PCwithsolidmounting
hardwareMounting DIN-rail,stack,wall
GeneralCertifications CE,FCCclassALEDIndicators Network:Tx/Rx,Link,Speed(10/100
Mbps) Serial:Tx/Rx System:Power,StatuspowerPowerInput Unregulated10~30VDCPowerConsumption 3WEnvironmentOperatingTemp. 0~60°C(32~140°F)StoringTemp. -20~80°C(-4~176°F)OperatingHumidity20~95%(non-condensing)StoringHumidity 0~95%(non-condensing)
ordering informationADAM-4572 1-PortModbustoEthernetData
Gateway
typical application: