acutus medical transseptal access system · 6/23/2020 · note: all steerable and fixed-curve...
TRANSCRIPT
-
Acutus MedicalTransseptal Access SystemFor Mechanical or RF Energy Application
AcQCross™ Qx
AcQGuide® FLEX
AcQGuide® MINIMM-67 Rev. D
-
Designed for Patient Safety & Physician Confidence•Left-handedoperationofintroducerallowsforsimultaneousright-handcontrolofablationcatheters
•±180°deflectionwithsinglefullactuationcycleEnhanced Procedural Efficiency•Ergonomichandledesignminimizesfatigueoverlongprocedures
•Simultaneouscontrolofneedle/dilatorandsheathpositioningthroughneedle/dilator/sheathlockingmechanism
•MitigateriskofentanglementwithdistallylocatedsideportReduced Shelf Space•Lengthmatchedneedlepre-packagedwithintroducer
Designed for Patient Safety & Physician Confidence•On-demandneedledeployment•Craftedforphysiciancontrol•Automaticlengthmatchedneedle/dilatorreducesriskofskiving
•SafelyadvancesystemoverguidewireintoLAEnhanced Procedural Efficiency•Localization/repeatlocalizationoffossaovaliswithoutneedle/guidewireexchange
•Improvedneedlevisualizationonintracardiacechocardiography
•RFenergycapabilityImproved Fossa Ovalis Localization•EGM-basedpositioningthroughdilatorfacilitatesfossaovalislocalization
•EGMmorphologytrackssafeadvancementintoLA
No-Stress Access Transseptal System with RF
MM-67 Rev. D
-
WIRE + NEEDLE + DILATOR + INTRODUCER SET
Designed for Patient Safety. Crafted for Physician Confidence.
PRODUCT NAME PRODUCT DESCRIPTION PRODUCT CATEGORY ITEM #
AcQGuide®FLEX-65cm-MEDCurl 65cm,MedCurl,8.5FID,12FOD SteerableIntroducer 122852
AcQGuide®FLEXwithRF-65cm-MEDCurl 65cm,MedCurl,8.5FID,12FOD SteerableIntroducer 222852
AcQGuide®MINI-65cm-L2 65cm,90deg,8.5FID,12FOD CatheterIntroducer 112852
AcQGuide®MINIwithRF-65cm-L2 65cm,90deg,8.5FID,12FOD CatheterIntroducer 212852
AcQGuide®MINI-SwithRF-65cm-L2 65cm,90deg,8.5FID,12FOD CatheterIntroducer 012852
ORDERING INFORMATION
Designed for Patient Safety & Physician Confidence•Facilitatepositioningwithfixeddistalcurve•Enhancedtorqueabilityandindicationofintroducertipcurvedirection
•ReducepotentialforinjurywithatraumaticdistaltipEnhanced Procedural Efficiency•Simultaneouscontrolofneedle/dilatorandsheathpositioningthroughneedle/dilator/sheathlockingmechanism
•Mitigateriskofentanglementwithdistallylocatedsideport•Radiopaquedistalmarkerforvisualizationunderfluoroscopy
Reduced Shelf Space•Lengthmatchedneedle/dilatorpackagedwithintroducer
AcQGuide®FLEXSteerableIntroducerwithAcQCross™Qx:FDAclearedAcQGuide®MINIFixed-CurveIntroducerwithAcQCross™Qx:FDAcleared
NOTE:AllSteerableandFixed-CurveproductspackagedwithappropriatelengthAcQCross™QxTransseptalDilator/Needle(8.5FOD) MM-67 Rev. D
-
ACUTUS MEDICAL, INC. 2210FaradayAveSuite100Carlsbad,CA92008UnitedStatesPhone:+1-442-232-6080acutus.com
Priortousingthesedevices,pleasereviewtheInstructionsforUseforacompletelistingofindications,contraindications,warnings,precautions,potentialadverseeventsanddirectionsforuse.TheAcQGuideFLEXandAcQGuideMINIdevicesareFDAcleared.acutus.com/patents
AcutusMedical,theAcutusMedicallogoandAcQGuideareregisteredtrademarksofAcutusMedical,Inc.AcQCrossQx,AcQGuideFLEX,AcQGuideMINIaretrademarksofAcutusMedical.ThismaterialisthepropertyofAcutusMedicalanditssubsidiaries.Pleasedonotcopy,forward,ordistributethisdocument.Copyright©2020AcutusMedical,Inc.Allrightsreserved.
MM-67 Rev. D