accuracy of gastrocnemius.. slide
TRANSCRIPT
![Page 1: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/1.jpg)
Accuracy of gastrocnemius muscles forces in walking and running goats predicted by one-element and two-element Hill-type models
Author: Lee, S. S Published: Sep. 2013
Presenter: Christopher D. Whitney
![Page 2: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/2.jpg)
Introduction
● Hill-type muscle models are commonly used to predict muscle forces ● However, they are not very accurate during relevant movements (i.e. walking,
running, etc.) ● This study evaluates a novel two element Hill-type model
○ Inspired by the different muscle fiber types (e.g ‘fast’ and ‘slow’)
![Page 3: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/3.jpg)
Methods
● Data collection ○ Goats were trained to walk, trot and gallop on a motorized treadmill○ Lateral and medial gastrocnemius were instrumented w/
■ Implanted EMG electrodes to measure activation■ Sonomicrometry crystals to measure fascicle length (resolution 0.3 μm) ■ “E”-shaped tendon buckles to measure tendon forces
○ Recorded in-vivo during 15-20 strides during different conditions (e.g walking, trotting, galloping) at 5000 Hz
○ Force–length and force-velocity relationships were calculated in-situ
![Page 4: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/4.jpg)
Methods (Cont.)
● Data processing ○ Motor recruitment signals for slow and fast fiber types were identified through a wavelet
optimization [2]
○ Transfer function were derived for the whole muscle as well as the slower and faster motor units (see below)
○ Constants were identified for the different motor units and were determined from in-situ data pooled from the six goats.
Constants
![Page 5: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/5.jpg)
Muscle Model
Active-FL Passive FL Pennation AngleScaling Factor Total Force
![Page 6: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/6.jpg)
Are you ready for the schematic?
![Page 7: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/7.jpg)
![Page 8: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/8.jpg)
Results
![Page 9: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/9.jpg)
![Page 10: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/10.jpg)
![Page 11: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/11.jpg)
![Page 12: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/12.jpg)
Results
● In-vivo forces yielded r2 values (0.26-0.51)● In-situ forces yielded r2 values (0.8–0.95) ● Two-element model more accurately than the one-element model under in situ
and in vivo conditions
![Page 13: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/13.jpg)
Limitations
![Page 14: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/14.jpg)
Limitations● Assumption that activation, force–length, and force–velocity properties are
independent ● Failure to account for history-dependent effects● Time resolution errors in the Gauss filter applied during the wavelet analysis● Exclusion of tendon in the model
![Page 15: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/15.jpg)
Questions?Thoughts?
![Page 16: Accuracy of gastrocnemius.. Slide](https://reader031.vdocuments.mx/reader031/viewer/2022021922/5874f7611a28ab917a8b82b3/html5/thumbnails/16.jpg)
References 1. Lee, S.S., Arnold, A.S., Miara, M. de B., Biewener, A.A. and Wakeling, J.M. 2013. Accuracy
of gastrocnemius muscles forces in walking and running goats predicted by one-element and two-element Hill-type models. Journal of biomechanics. 46, 13 (Sep. 2013), 2288–95.
2. Lee, S.S., Miara, M. de B., Arnold, A.S., Biewener, A.A. and Wakeling, J.M. 2011. EMG analysis tuned for determining the timing and level of activation in different motor units. Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology. 21, 4 (Aug. 2011), 557–65.