Use them your way. Professional-grade instruments for field service Accessory Heads for HVAC/R HS Series Stick Meter EHDL1 Electronic Handle Now you can use Fieldpiece accessory heads while using your multimeter for something else. Has MIN and MAX function. Use the AHDL1 adapter to use any Fieldpiece accessory with a meter with industry standard jacks and a mV scale. AAV3 Air Velocity & Temp Use to estimate CFM. Measures Ft/min, meters/sec, MPH, KM/hr. Range: 80 to 5900 ft/min. ºC and ºF. Range: -4ºF to 140ºF. Auto-off. ACD1 Carbon Dioxide Use in addressing IAQ. Range: 0-2000PPM. Gas sampling mode: diffusion. Repeatability: ±9PPM. Auto-off. ACH Current Clamp Measures to 300AAC. Maximum conductor size: 0.91". No battery needed. ACM3 Carbon Monoxide Measures CO in air and finds CO sources. Fast enough for “walk-around” test. Average mode for smoothing and normal mode for fast response to change. Range: 0-2000PPM. Auto-off. AMN2 Manometer (Pressure) Measures gas pressure and has resolution low enough for static pressure. Maximum 20” WC (water column) for gas pressure. 0.01” WC resolution for static pressure. Manual zero-set. Auto-off. ARH3 Temp and RH% Measures air temperature & RH%. ºC and ºF. Auto-off. ASH2 Superheat Measures refrigerant pressure, temperature, and calculates superheat for two refrigerants. Pressure: PSI and kPa. Temperature: ºC and ºF. Superheat: ºC and ºF. Select R22 or R410A. Auto-off. ATIR3 Non-contact (Infrared) Surface Temperature Laser sight. 8:1 field of view. ºC and ºF. Range: 0ºF to 752ºF. Auto-off. ATRMS3 True RMS Converts digital meter to true RMS meter. Cost effective way to measure true RMS. Works with current clamps. Auto-off. AUA2 Milliamps & Microamps Measures milliamps and microamps for flame diode test. Measures 4 to 20mA control circuits. Includes flame diode adapter kit. Max current: 200mA AC or DC. AVG1 Vacuum Gauge Displays pressure in microns in steps of 1 micron. Has pump down indication show- ing progress from atmospheric pressure. Range: 50-2000 microns of mercury. Straight in access to sensor for easy cleaning. Fitting: male 1/4” flared brass. Auto-off. AVH1 Voltage Records voltage using DL2 data logger or EHDL1 electronic handle. Max voltage: 600V. Add to any meter with a mV scale. Any Meter w/ AHDL1 Adapter Data log measure- ments from any Fieldpiece accessory head. View the recorded values directly on the LCD screen or upload to a PC. ATH4 Dual Temperature Two k-type thermocouple inputs. Display T1, T2, or T!-T2. ºC and ºF. Range: -50ºF to 1800ºF with optional thermocouples. Includes two ATB1 thermocouples and two velcro straps. Auto-off. ARH4 Wet Bulb and Dew Point Measures air tem- perature and RH% and displays wet bulb and dew point. ºC and ºF. Auto-off. DL2 Data Logger Add any head to this meter which already measures parameters needed most by HVAC/R technicians. www.fieldpiece.com Convert any head to a standalone instrument Use with any meter with a mV scale Data log many different parameters The Heart of Fieldpiece

Upload: others

Post on 20-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Accessory Heads - Fieldpiece · AVG1 Vacuum Gauge Displays pressure in microns in steps of 1 micron. Has pump down indication show-ing progress from atmospheric pressure. Range: 50-2000

Use them your way.

Professional-grade instruments for field service

Accessory Headsfor HVAC/R

HS Series Stick Meter

EHDL1 Electronic Handle

Now you can useFieldpiece accessoryheads while using your multimeter for something else. Has MIN and MAX function.

Use the AHDL1 adapterto use any Fieldpieceaccessory with ameter with industry standard jacksand a mV scale.

AAV3 Air Velocity & TempUse to estimate CFM.

■ Measures Ft/min, meters/sec, MPH, KM/hr.

■ Range: 80 to 5900 ft/min.

■ ºC and ºF.

■ Range: -4ºF to 140ºF.

■ Auto-off.

ACD1 Carbon DioxideUse in addressing IAQ.

■ Range: 0-2000PPM.

■ Gas sampling mode: diffusion.

■ Repeatability: ±9PPM.

■ Auto-off.

ACH Current ClampMeasures to 300AAC.

■ Maximum conductor size: 0.91".

■ No battery needed.

ACM3 Carbon MonoxideMeasures CO in air and finds COsources.

■ Fast enough for “walk-around” test.

■ Average mode for smoothing and normal mode for fast response to change.

■ Range: 0-2000PPM.

■ Auto-off.

AMN2 Manometer (Pressure)Measures gas pressure and has resolution lowenough for static pressure.

■ Maximum 20” WC (water column) for gas pressure.

■ 0.01” WC resolution for static pressure.

■ Manual zero-set.

■ Auto-off.

ARH3Temp and RH%Measures air temperature &RH%.

■ ºC and ºF.

■ Auto-off.

ASH2 SuperheatMeasures refrigerantpressure, temperature,and calculates superheatfor two refrigerants.

■ Pressure: PSI and kPa.

■ Temperature: ºC and ºF.

■ Superheat: ºC and ºF.

■ Select R22 or R410A.

■ Auto-off.

ATIR3 Non-contact(Infrared) SurfaceTemperatureLaser sight.

■ 8:1 field of view.

■ ºC and ºF.

■ Range: 0ºF to 752ºF.

■ Auto-off.

ATRMS3 True RMSConverts digital meter to true RMS meter.

■ Cost effective way to measure true RMS.

■ Works with current clamps.

■ Auto-off.

AUA2 Milliamps & Microamps Measures milliamps and microamps for flame diode test.

■ Measures 4 to 20mA control circuits.

■ Includes flame diode adapter kit.

■ Max current: 200mA AC or DC.

AVG1 Vacuum GaugeDisplays pressure inmicrons in steps of 1 micron. Has pump down indication show-ing progress from atmospheric pressure.

■ Range: 50-2000 microns of mercury.

■ Straight in access to sensor for easy cleaning.

■ Fitting: male 1/4” flared brass.

■ Auto-off.

AVH1VoltageRecords voltageusing DL2 data logger or EHDL1electronic handle.

■ Max voltage: 600V.

Add to any meter with a mV scale.

Any Meter w/ AHDL1 Adapter

Data log measure-ments from anyFieldpiece accessoryhead. View the recorded values directly on the LCDscreen or upload to a PC.

ATH4 Dual TemperatureTwo k-type thermocouple inputs.

■ Display T1, T2, or T!-T2.

■ ºC and ºF.

■ Range: -50ºF to 1800ºF with optional thermocouples.

■ Includes two ATB1 thermocouples and two velcro straps.

■ Auto-off.

ARH4 Wet Bulb andDew PointMeasures air tem-perature and RH%and displays wetbulb and dew point.

■ ºC and ºF.

■ Auto-off.

DL2 Data Logger

Add any head to thismeter which alreadymeasures parametersneeded most byHVAC/R technicians.

www.fieldpiece.com

Convert any head to a standalone instrument

Use with any meterwith a mV scale

Data log many different parameters

The Heart of Fieldpiece