accelerated lifetime test - phase 3gan/talk/5050_2-7-15.pdf2015/02/07  · accelerated lifetime test...

3
Accelerated Lifetime Test - Phase 3 November 2014 started four D opto-boards in 50º C / 50 % RH Boards fabricated throughout production (4041, 4209, 4151, 4311) Have accumulated 4125 hours running time Run PIN arrays at 5 V bias Run VCSELs at 40 MHz (50% duty cycle), 10mA pk-pk

Upload: others

Post on 22-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Accelerated Lifetime Test - Phase 3gan/talk/5050_2-7-15.pdf2015/02/07  · Accelerated Lifetime Test - Phase 3 • November 2014 started four D opto-boards in 50º C / 50 % RH –

Accelerated Lifetime Test - Phase 3 •  November 2014 started four D opto-boards in 50º C / 50 % RH

–  Boards fabricated throughout production (4041, 4209, 4151, 4311) –  Have accumulated 4125 hours running time

•  Run PIN arrays at 5 V bias•  Run VCSELs at 40 MHz (50% duty cycle), 10mA pk-pk

Page 2: Accelerated Lifetime Test - Phase 3gan/talk/5050_2-7-15.pdf2015/02/07  · Accelerated Lifetime Test - Phase 3 • November 2014 started four D opto-boards in 50º C / 50 % RH –

Accelerated Lifetime Test - Phase 3 •  Optical power during 4125 hours in 50º C / 50 % RH

4041 4209

Page 3: Accelerated Lifetime Test - Phase 3gan/talk/5050_2-7-15.pdf2015/02/07  · Accelerated Lifetime Test - Phase 3 • November 2014 started four D opto-boards in 50º C / 50 % RH –

Accelerated Lifetime Test - Phase 3 •  Optical power during 2897 hours in 50º C / 50 % RH

4151 4311