ac-tc-30 rev 2017sep - home - acd · liquid nitrous oxide is a potentially dangerous fl uid and...

2
MODEL AC/TC-30 Close coupled design provides: - Operations at high efficiencies - Fewer moving parts - Lower maintenance costs Shaft seal design (mechanical, gas riding or labyrinth) are state-of-the-art and prolong life without leakage VFD compatibility allows for multiple operating speeds Minimum recirculation wear rings reduce maintenance requirements and improve efficiencies Liquid storage transfer Process plant Truck and trailer off-loading Tank car unloading Nitrogen Oxygen Argon Methane Labyrinth seal (dual, single) Gas riding seal Pump skid Automatic control system Purge, seal and recommended spare parts kits FEATURES & BENEFITS APPLICATIONS LIQUIDS PUMPED OPTIONAL ACCESSORIES CLOSE COUPLED PUMP Consult ACD engineering for actual performance ratings. SPECIFICATIONS Flow Range gpm 16 – 630 lpm 60 – 2,350 NPSHR feet 2 – 12 meter 0.6 – 4 Differential Head feet 20 – 700 meter 6 – 210 Pump Design Rating hp 3 – 100 kw 2.2 – 75 Speed Range rpm 1,450 – 7,200 Pump and TEFC electrical motor shown Long life CFS mechanical seal Motor and seal purge ports TYPICAL SCOPE OF SUPPLY

Upload: others

Post on 28-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

MODEL AC/TC-30

• Close coupled design provides: - Operations at high effi ciencies - Fewer moving parts - Lower maintenance costs

• Shaft seal design (mechanical, gas riding or labyrinth) are state-of-the-art and prolong life without leakage

• VFD compatibility allows for multiple operating speeds

• Minimum recirculation wear rings reduce maintenance requirements and improve effi ciencies

• Liquid storage transfer

• Process plant

• Truck and trailer off -loading

• Tank car unloading

• Nitrogen

• Oxygen

• Argon

• Methane

• Labyrinth seal (dual, single)

• Gas riding seal

• Pump skid

• Automatic control system

• Purge, seal and recommended spare parts kits

FEATURES & BENEFITS APPLICATIONS

LIQUIDS PUMPED

OPTIONAL ACCESSORIES

CLOSE COUPLED PUMP

Consult ACD engineering for actual performance ratings.

SPECIFICATIONS

Flow Rangegpm 16 – 630

lpm 60 – 2,350

NPSHRfeet 2 – 12

meter 0.6 – 4

Diff erential Headfeet 20 – 700

meter 6 – 210

Pump Design Rating

hp 3 – 100

kw 2.2 – 75

Speed Range rpm 1,450 – 7,200

• Pump and TEFC electrical motor shown

• Long life CFS mechanical seal

• Motor and seal purge ports

TYPICAL SCOPE OF SUPPLY

Liquid Nitrous Oxide is a potentially dangerous fl uid and must be handled with extreme care. See Compressed Gas Association standard CGA G-8.3-2016 for further information. Under certain combinations of temperature and pressure Nitrous Oxide can explosively decompose with serious consequences. Nitrous Oxide is an oxidizer that actively supports combustion. Nitrous Oxide handling equipment must be cleaned for Oxygen service. Design and construction of storage and piping systems for pumping liquid Nitrous Oxide must assure material compatibility and be such as to prevent loss of prime or “dry running” of pumps. Nitrous Oxide is an active solvent for many materials and material compatibility with Nitrous Oxide must be confi rmed before their use. For additional historical information relating to hazards associated with Nitrous Oxide decomposition refer to Chemical Safety Board report number 2016-04-I-FL Dated February 2017.

FOR PUMPS INTENDED TO BE USED IN NITROUS OXIDE SERVICE

Bulletin No. AC/TC30-R2.17© 2017 ACD LLC, Printed in USA

MANUFACTURING

2321 S. Pullman Street Santa Ana, CA 92705 USATel 800.525.4216 (USA only)Tel +1.949.261.7533 • Fax [email protected] • acdllc.com

GLOBAL SERVICE

NORTH AMERICAAtlantaAtlanta, Georgia, USA+1 404.696.8113 • Fax +1 [email protected] • cryoindservice.com

California (ACD Service) Santa Ana, California, USA+1.714.568.0201 • Fax [email protected] • acdcom.com

HoustonHouston, Texas, USA+1 281.590.4800 • Fax +1 [email protected] • cryoindservice.com

PittsburghImperial, Pennsylvania, USA+1 724.695.1910 • Fax +1 [email protected] • cryoindservice.com

Red DeerRed Deer, Alberta, Canada+1.403.352.4436 • Fax [email protected] • cryoindservice.com

TorontoToronto, Ontario, Canada+1 416.502.1950 • Fax +1 [email protected] • cryoindservice.com

INTERNATIONALAustraliaDandenong, Victoria, Australia+61.3.9791.7888 • Fax [email protected] • cryoquip.com

ChinaHangzhou, China+86.571.8619.4799 • Fax [email protected] • cryoindservice.com

Europe (ACD CRYO)CH-4142 Muenchenstein Switzerland+41.61.413.0230 • Fax: [email protected] • acdcryo.com

D-79415 Bad Bellingen Germany+49.7635.8105.0 • Fax: [email protected] • acdcryo.com

United Arab EmiratesJebel Ali Free Zone, Dubai, UAETel: [email protected] • acdcom.com

IndiaA Division of Rhine Engineering Pvt. Ltd.Vadodara, Gujarat, India+91.265.283 0113 • Fax +91.265.283 [email protected] • acdcom.comKolkatta, West Bengal, India+91.973.216 [email protected] • acdcom.com

KoreaYongin-si, Gyeonggi-do, Korea+82.31.286.6114 • Fax [email protected] • cryoindservice.com

Malaysia Shah Alam, Selangor D.Ehsan, Malaysia+60 (3) 5740.4800 • Fax +60 (3) [email protected] • cryoindservice.com

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

MODEL AC/TC-30

PUMP PERFORMANCE CURVE

60 HZ performance

100

100 200 300 400 500 600 700

380 760 1140 1520 1900 2280 2650

200

300

400

500

600

700

800

30

60

90

120

155

185

215

245

Flow Rate [gpm]

Flow Rate [lpm]

Diff

eren

tial

Hea

d [

feet

]

Diff

eren

tial

Hea

d [

met

ers]

0

239

12 & 10

13

11

22

814 24

25

1720

21

1816

2

115

3

19

6 & 74 & 5

MODEL AC Pump ID Pump Size

1234567891011121314

.5 x .5 x 31 x 2 x 4.51 x 3 x 8.51.5 x 2.5 x 6A1.5 x 3 x 62 x 3 x 62 x 4 x 61.5 x 2.5 x 7-2SN2 x 4 x 8.53 x 5 x 8.52 x 4 x 133 x 4 x 8.54 x 5 x 10.51.5 x 3 x 10.5

MODEL TC Pump ID Pump Size

1516171819202122232425

.75 x 1 x 41 x 2 x 61 x 2 x 6-2S1.5 x 2.5 x 6C2 x 4 x 7.371.5 x 3 x 71.5 x 3 x 7-2S1.5 x 2.5 x 102 x 5 x 7.372 x 4 x 91.5 x 2.5 x 10N