ac airwell product range 2010-11

48
Product Range www.airwell.com 2010/2011

Upload: emil-bonello-ghio

Post on 30-Mar-2016

315 views

Category:

Documents


10 download

DESCRIPTION

Product Range www.airwell.com

TRANSCRIPT

Page 1: AC Airwell Product Range 2010-11

Product Range

www.airwell.com

2010/2011

Page 2: AC Airwell Product Range 2010-11

AirwellA Strong EuropeanBrand

2

As an internationally oriented company, Airwell Group has pro-

duction facilities, development centres and sales branches

throughout the world. Our plants each specialise in the produc-

tion of individual product groups that to a large extent meet

regional market requirements, and ensure that transport

distances are kept as short as possible. In addition to our own

sales subsidiaries, over 200 distributors in over 80 countries

now trust the quality and service of the Airwell Group.

Worldwide Production Facilities

Six production facilities throughout the world with over 2.500

employees produce between 1.500.000 and 2.000.000 air con-

ditioning units annually. In Europe, AIRWELL is one of the 5

top-ranking brands.

Tillières (France)

Production of: Commercial Condensing Units, Rooftops, Chilled

Water Terminals and Residential Hydronic Systems.

Milan (Italy)

Production of: Air & Water Cooled Chillers, Close Control Units

and Air Cooled Condensing Units.

Shenzhen (China)

Production of: Ductfree Split Units and Water Cooled Conden-

sing Units.

Pons ( France)

Production of: Air Handling Units, Unit Heaters and Modular

Ducted Air Handling Units.

Airwell is the ideal partner for perfect climate solutions,

providing air conditioning and air treatment systems for

all applications. Founded in 1947, Airwell Group is today

one of the global leaders for the manufacture and distri-

bution of high class, environmentally-balanced and reliable

air conditioning systems. Striving for long-term customer

relationships, the Airwell Group provides individual con-

sultancy and professional servicing. Airwell Group is the

ideal partner for perfect climate solutions in residential,

light commercial and industrial applications. Airwell

Group’s products provide comfort, wellbeing and quality

of life, helping to increase people’s productivity. Airwell

Group today has one of the widest product ranges and

distribution networks on the market.

Page 3: AC Airwell Product Range 2010-11

3

Top left: Airwell Group Head

Office near Paris

Top right: Barlassina

Middle left: Shenzhen

Middle right: Tillieres

Bottom: Pons

Pons France

Manufacturing

Airwell Group (Head office: Paris)

Sales & Marketing & Service

France

Italy

Spain

Germany

USA

China

Export

OEM

Tillières France

Milan Italy

Shenzhen China

Shanghai China

Shenzhen China

Tillières France

Milan Italy

Research & Development

Page 4: AC Airwell Product Range 2010-11

AirwellTop Class Air Conditioning Technology

4

Central Air Conditioning Units

With direct expansion and high performance levels, these

appliances are suitable for air conditioning several rooms

centrally.

• Central air conditioning units from 5.2 to 152.8 kW

Close Control and Air Handling Units

Airwell offers a comprehensive range: centralised air-handling

units for indoor and outdoor installation or compact rooftops with

integrated cooling or heat pump on request.

• Ventilation and air conditioning technology up to 100.000 m3/h

• Rooftops from 20 to 220 kW

Chilled Water

Airwell chiller are completely set up on refrigerant and water

side and are ready for immediate use after installation. A com-

plete range of cold water terminals is available.

• Chiller from 4.5 to 1.300 kW

Comfort Room Air Conditioners

The AIRWELL Comfort range aims at smaller and medium-sized

rooms. Perfect for household and commercial use.

• DC Inverters from 1.4 to 9.0 kW

• Fix Speed from 2.1 to 16.9 kW

Multi-Split Air Conditioners

Multi-split air-conditioners are used when you want to cool seve-

ral rooms with only one external unit. There are three basic ver-

sions of multi-split air-conditioners.

• Duo, up to 2 indoor units

• Trio, up to 3 indoor units

• Quattro, up to 4 indoor units

• Cinco, up to 5 indoor units

VRF-FlowLogic

The VRF FlowLogic system is available for applications of up

to 40 indoor units. Whether for residential, light commercial or

industrial use, the compact units provide a cooling capacity of

up to 135 kW. All of the standard units are designed as heat

pumps, and for applications requiring simultaneous cooling

and heating. The outdoor units that are 22 kW and larger are

also available as 3-pipe units.

• Mini-FlowLogic - the compact category

Cooling 11.2 – 15.5 kW or Heating 12.5-17.6 kW

• MFL / EFL – capacity according to size

2-pipe units (cooling and heating) and

3-pipe units MFL/EFL (cooling and heating)

Cooling 22.4 - 135 kW

Heating 25.0 - 150 kW

Page 5: AC Airwell Product Range 2010-11

5

Content

Comfort Room

Air Conditioner 6 - 14

Multisplit Room

Air Conditioner 15 - 17

VRF FlowLogic 18 - 23

Centralized Airconditioning

Systems 25 - 30

Central Air Conditioning 31 - 32

Chiller and Heat Pumps 33 - 45

Page 6: AC Airwell Product Range 2010-11

6

Mobile Range

Portable air-conditioners are the entry-level solution for room air cooling and dehumidification.

Thanks to their castors they can be moved from room to room. There are no installation costs;

all you need is a power socket.

Window Room Air Conditioner

In contrast to split units, compact units combine the indoor part and the outdoor part in one unit.

This is simply installed through the wall or a window.

Single Split Range

An indoor unit is connected to an outdoor unit and a room is thus air conditioned. There are two

types of split-air conditioners: "ON/OFF" units (fix speed units) and inverter units (variable speed

units).This inverter technology sets new standards and fulfills the highest possible demands on

heating and cooling. The inverter system with its variable need-driven compressor guarantees

optimum control of the temperature and the air moisture. This need-driven method of operation

enables an energy saving of up to 40%.

AirwellDC Inverter Air ConditionerRange

AirwellRaumklima -geräteOn/Off

AirwellOn/Off AirConditionerRange

Page 7: AC Airwell Product Range 2010-11

7

MOBILE /MONOBLOCRANGE

AELIAPORTABLE UNITS

2 Cooling models (Heat Pump)From 2,600 to 3,500 W

MAY WINDOW UNITS

5 Cooling models From 2,140 to 6,400 W

AELIA

MAY

2,600 3,500

9A 12A

2,140 2,540 3,280 5,000 6,400

70 90 110 180 220

All performances in watt

Page 8: AC Airwell Product Range 2010-11

8

WALLMOUNTED ON/OFF Range

HAFWALL MOUNTED

5 Models Cooling / Heat PumpFrom 2,100 to 6,770 W

PRIME WALL MOUNTED

5 Models Cooling / Heat PumpFrom 2,050 to 6,770 W

FLO NWALL MOUNTED

2 ModelsCooling / Heat PumpFrom 8,500 to 10,150 W

MODELPRIME

HAFFLO N

2,050 2,760 3,600 55,500 6,770 - -

2,100 2,500 3,500 5,240 6,770 - -

- - - - - 8,200 -

7 9 12 18 24 30 36

All performances in watt

Page 9: AC Airwell Product Range 2010-11

9

MODELPNXO DCIHCD DCIHFD DCIHAD DCIXLF DCI

WALLMOUNTED DCI Range

PNXO DCINVERTER WALL MOUNTED

6 Heat Pump modelsFrom 2,500 to 7,800 W

HCD DCINVERTER WALL MOUNTED

5 Heat Pump modelFrom 2,500 to 6,800 W

HFD DCINVERTERWALL MOUNTED

4 Heat Pump modelsFrom 2,200 to 5,000 W

XLF DCINVERTERWALL MOUNTED

2 Heat Pump modelsFrom 2,500 to 3,500 W

HAD DCINVERTERWALL MOUNTED

5 Heat Pump modelsFrom 2,200 to 6,800 W

- 2,500 3,500 5,000 6,000 6,800 7,800 -

- 2,500 3,500 5,000 6,000 6,800 - -

2,200 2,500 3,500 5,000 - 6,800 - -

- 2,500 3,500 - - - - -

2,200 2,500 3,500 5,000 - - - -

7 9 12 18 21 24 30 36

All performances in watt

Page 10: AC Airwell Product Range 2010-11

10

FLOOR/CEILING ON/OFF Range

FBFFLOOR/CEILING

6 Heat Pump modelsFrom 8,350 W to 13,800 W

SX NFLOOR/CEILING

5 Models Cooling / Heat PumpFrom 2,660 to 8,150 W

CASSETTEON/OFF Range

CKFCASSETTES

7 Models Cooling / Heat PumpFrom 2,750 to 12,350 W

MODELSX N

CKF

MODELFBF

S

2,660 3,520 5,050 6,700 8,150 - -

9 12 18 24 30 36 45

8,350 10,800 12,800 13,800

- - - -

30 36 45 60

2,750 3,250 5,100 6,800 8,300 8,700 12,350

All performances in watt

Page 11: AC Airwell Product Range 2010-11

11

FLOOR/CEILING DCI Range

SX DC INVERTER FLOOR/CEILING

6 Heat Pump modelsFrom 2,500 to 7,500 W

MODEL

SX DCI

FWD DCI

FBD DCI

CK DCI

2,500 3,500 5,000 6,000 6,800 7,500 - -

9 12 18 21 24 30 36 45

CASSETTEDCI Range

CK DCINVERTERCASSETTES

8 Heat Pump modelsFrom 2,500 to 12,100 W

FWB DC INVERTER FLOOR/CEILING

3 Cooling modelsFrom 3,200 to 6,800 W

FBD DC INVERTER FLOOR/CEILING

2 Heat Pump modelsFrom 9,500 to 12,500 W

- 3,200 5,000 - 6,800 - - -

- - - - - - 9,500 12,500

2,500 3,500 5,000 5,800 6,800 8,000 10,000 12,500

All performances in watt

Page 12: AC Airwell Product Range 2010-11

12

DUCTED ON/OFF Range

DUCTEDUNITSDC Inverter

DLS / CDDUCTED

5 ModelsCooling / Heat PumpFrom 5,300 to 16,400 W

DLS / DC DCIINVERTERDUCTED

5 Heat Pump modelsFrom 5,000 to 14,500 W

DLF DCINVERTERDUCTED

5 Heat Pump modelsFrom 2,500 to 7,000 W

MODELDLS

CD

MODELDLF DCI

DLS / CD DCI

9 12 18 21 24 30 37 44 60

9 12 18 21 24 30 36 43 60

- - 5,370 - 6,200 8,600 10,600 12,600 -

- - - - - - - - 16,400

2,500 3,500 5,000 6,100 7,000 - - - -

- - 5,000 6,600 7,100 7,500 10,000 12,500 14,500

All performances in watt

Page 13: AC Airwell Product Range 2010-11

13

COLUMNSPLIT SYSTEMON/OFF Range

SAF COLUMN SPLIT SYSTEM

1 Heat Pump model12,300 W

SAF12,300

45

All performances in watt

WATER CONSOLEUNITSON/OFF Range

CAOWATER CONSOLE

3 Cooling modelsFrom 2,300 to 4,700 W

CAO

2,300 3,000 4,700

230 370 580

Page 14: AC Airwell Product Range 2010-11

14

WATERCOOLEDUNITSON/OFF Range

GCAO NWATER COOLED UNITS

8 Cooling modelsFrom 2,450 to 13,300 W

MODELS

PRIME, HAF

PRIME, HAF, SX, CKF

PRIME, SX, CKF, DLS

PRIME, HAF, SX, CKF, DLS

FLO, SX, CKF, DLS

CKF, DLS

2,450 - - - - - - -

- 2,950 3,850 - - - - -

- - - - - - 10,300 13,300

- - - 5,850 - - - -

- - - - 7,150 - - -

- - - - - 8,600 - -

7 9 12 18 24 30 36 45

Wall mounted PRIME Wall mounted FLO Wall mounted HAF

Floor/Ceiling SXCassette CKFDucted DLS

All performances in watt

Page 15: AC Airwell Product Range 2010-11

15

Unimagined possible combinations

Airwell offers a unique range of multi-split DC inverters. Whether the indoor units are wall-

mounted, ducted, cassette or floor-ceiling, the multi-split outdoor units allow the use of 2, 3, 4

or 5 different indoor units.

In this way the inverter technology sets new standards and fulfills the highest possible demands

on heating and cooling.

The inverter system, with its variable, need-driven compressor guarantees optimum control of

the temperature and the air moisture.

AirwellMultisplit DC On/Off Range

AirwellMultisplit DC InverterRange

Page 16: AC Airwell Product Range 2010-11

16

MULTISPLITSDC Inverter Range 2DUO

DC INVERTERMULTISPLITSFOR 2 INDOOR UNITS

1 Heat Pump modelof 5,000 W

3TRIO DC INVERTERMULTISPLITSFOR 3 INDOOR UNITS

1 Heat Pump modelof 7,200 W

4QUATTRODC INVERTERMULTISPLITSFOR 4 INDOOR UNITS

1 Heat Pump modelof 8,000 W

Ducted DLS DCI

Ducted DLF DCI

Floor/Ceiling SX DCI Wall mounted XLF DCI Cassette CK DCI

Wall mounted PNXO DCIWall mounted HCD DCI

Page 17: AC Airwell Product Range 2010-11

17

MULTISPLITSDC Inverter Range

MULTISPLITSDC Inverter Range

3TRIO DAKOTA DC INVERTERMULTISPLITSFOR 3 INDOOR UNITS

1 Heat Pump modelof 5,200 W

2DUO DAKOTA DC INVERTERMULTISPLITSFOR 2 INDOOR UNITS

1 Heat Pump modelof 3,900 W

5CINCODC INVERTERMULTISPLITSFOR 5 INDOOR UNITS

1 Heat Pump modelof 11,000 W

DUO, TRIO, QUATTRO, CINCO

DCI

DUO DAKOTATRIO DAKOTA

DCI

5,000 7,200 8,000 11,000

DUO DCI TRIO DCI QUATTRO DCI CINCO DCI

3,900 5,200 - -

DUO DAKOTA DCI TRIO DAKOTA DCI

All performances in watt

Ducted DLS DCI Ducted DLF DCIFloor/Ceiling SX DCI Wall mounted XLF DCI

Wall mounted HFD DCI

Cassette CK DCI

Wall mounted PNXO DCIWall mounted HCD DCI Wall mounted HAD DCI

Page 18: AC Airwell Product Range 2010-11

18

AirwellVRF FlowLogic

VRF FlowLogic

With Airwell FlowLogic you are always making the right choice. Whether for residential, light

commercial or industrial use, the compact units provide a cooling capacity of up to 135 kW, with

up to 40 indoor units. All of the standard units are designed as heat pumps. For applica tions

requiring simultaneous cooling and heating, the outdoor units that are 22 kW and larger are also

available as 3-pipe units. The possible applications for Airwell FlowLogic are diverse: offices,

administration areas and conference rooms, sales and commercial areas, living spaces and

hotels.

Page 19: AC Airwell Product Range 2010-11

19

FLOWLOGICINDOOR UNITS:Cassettes

ST-NKFL 4-WAY-CASSETTE

9 ModelsCooling: 2.2 – 16.0 kWHeating: 2.5 – 18.0 kW

ST-NK2FL 2-WAY-CASSETTE

6 ModelsCooling: 2.2 – 7.3 kWHeating: 2.5 – 8.0 kW

ST-NK1FL 1-WAY-CASSETTE

5 ModelsCooling: 2.8 – 7.3 kWHeating: 3.2 – 8.0 kW

MODEL

ST-NKFL

ST-NK2FL

ST-NK1FL

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) 16.0 (18.0)

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) - - -

- 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 7.3 (8.0) - - -

7 9 12 16 18 24 36 48 60

Values in brackets = rated heating capacity All performances in kilowatt

Page 20: AC Airwell Product Range 2010-11

20

FLOWLOGICINDOOR UNITS:Wall Mouted

ST-NWFLWALL MOUNTED

6 ModelsCooling: 2.2 – 7.3 kWHeating: 2.5 – 8.0 kW

XAVWALL MOUNTED

3 ModelsCooling: 2.2 – 3.6 kWHeating: 2.5 – 4.2 kW

FLOWLOGICINDOOR UNITS:Ducted

ST-NDSLPDUCTED

6 ModelsCooling: 2.2 – 6.4 kWHeating: 2.5 – 7.0 kW

ST-NDLPDUCTED

8 ModelsCooling: 2.2 – 14.0 kWHeating: 2.5 – 16.0 kW

ST-NDHPDUCTED

5 ModelsCooling: 7.3 – 28.0 kWHeating: 8.0 – 31.5 kW

Flat Panel

Standard pressure

High pressure

Page 21: AC Airwell Product Range 2010-11

21

FLOWLOGICINDOOR UNITS:Ceiling Units

ST-NPFL CEILING UNIT

6 ModelsCooling: 3.6 – 14.0 kWHeating: 4.2 – 16.0 kW

MODEL

ST-NWFL

XAV

ST-NDSLP

ST-NDLP

ST-NDHP

ST-NPFL

ST-NFFL

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) - - - -

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) - - - - - - - -

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 7.1 (6.3) - 7.3 (8.0) - - - -

2.2 (2.5) 2.8 (3.2) 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) 6.4 (7.0) - - - - -

2.2 (2.5) 2.8 (3.2) 3.6 (4.0) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) - -

- - 3.6 (4.2) 4.5 (5.0) 5.6 (6.3) - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) - -

- - - - - - 7.3 (8.0) 10.6 (11.4) 14.0 (16.0) 22.4 (25.0) 28.0 (31.5)

7 9 12 16 18 22 24 36 48 76 96

FLOWLOGICINDOOR UNITS:Fan Coil Units

ST-NFFLFAN COIL UNIT

6 ModelsCooling: 2.2 – 7.1 kWHeating: 2.5 – 8.0 kW

Values in brackets = rated heating capacity All performances in kilowatt

Page 22: AC Airwell Product Range 2010-11

22

MVIINDOOR UNITS

CKV/KXV CASSETTE

8 ModelsCooling: 2.2 – 11.0 kWHeating: 2.5 – 12.5 kW

SXV FLOOR/CEILING UNIT

7 ModelsCooling: 2.8 – 7.1 kWHeating: 2.5 – 8.0 kW

DLV/DSV DUCTED

7 ModelsCooling: 2.2 – 11.0 kWHeating: 2.5 – 12.5 kW

PNV WALL MOUNTED

6 ModelsCooling: 2.2 – 6.3 kWHeating: 2.5 – 7.0 kW

MODEL

CKV

SXV

DLV/DSV

PNV

2.2 2.8 3.6 4.5 5.6 6.3 7.1 9.0 11.0

2.2 2.8 3.6 4.5 5.6 6.3 7.1 - -

2.2 2.8 3.6 4.5 5.6 6.3 7.1 9.0 11.0

2.2 2.8 3.6 4.5 5.6 6.3 - - -

007 009 012 015 018 021 024 030 036

All performances in kilowatt

Page 23: AC Airwell Product Range 2010-11

23

MFL40/50/60 HMINI-FOWLOGIC

3 ModelsCooling: 11.2 – 15.5 kWHeating: 12.5 – 17.6 kW

MFL 80-480OUTDOOR UNIT (2 PIPE)

21 ModelsCooling: 22.4 – 135.0 kWHeating: 25.0 – 150.0 kW

EFL 80-480OUTDOOR UNIT (2 PIPE)

21 ModelsCooling: 22.4 – 135.0 kWHeating: 25.0 – 150.0 kW

FLOWLOGICOUTDOORUNITS

Page 24: AC Airwell Product Range 2010-11

24

MVIOUTDOORUNITS

YAVVRF OUTDOOR UNIT

3 ModelsCooling: 11.2 – 15.5 kWHeating: 12.5 – 18.0 kW

MFL/EFL 40/50/60

MFL/EFL 80-160

MFL/EFL 180-320

MFL/EFL 340-480

11.2 (12.5) 14.0 (16.0) 15.5 (17.6)

40 H 50 H 60 H

YAV11.2 (12.5) 14.0 (16.0) 15.5 (18.0)

112 140 160

22.4 (25.0) 28.0 (31.5) 33.5 (37.5) 40.0 (45.0) 45.0 (50.0)

80 100 120 140 160

50.4 (56.0) 56.0 (63.0) 61.5 (69.0) 68.0 (76.5) 73.0 (81.5) 78.5 (87.5) 85.0 (95.0) 90.0 (100.0)

180 200 220 240 260 280 300 320

96 (108) 101 (113) 107 (119) 113 (127) 118 (132) 124 (138) 130 (145) 135 (150)

340 360 380 400 420 440 460 480

Values in brackets = rated heating capacity All performances in kilowatt

Page 25: AC Airwell Product Range 2010-11

25

AirwellCentralised Air Conditioning Systems

Close Controls data processing units are well suited for precision air conditioning of rooms

and buildings when it is absolutely necessary to dissipate only sensible heat.

Monobloc units house all components together in a single unit, allowing installation and ope-

rating costs to be minimised.

Close Controls and ducted split terminal units together with the appropriate condenser units,

allow for optimal climate control even in difficult conditions.

The ventilation and air conditioning technology, with a comprehensive range of rooftops

and centralised air-handling units, provides the right solution for many applications such as shop-

ping centres, furniture stores, exhibition halls, cinemas and production facilities.

Page 26: AC Airwell Product Range 2010-11

26

AIR COOLEDSPLIT SYSTEMS

DK/DNAIR COOLED SPLIT UNIT

12 ModelsCooling / Heat PumpFrom 12.0 to 83.0 kW

Condensing Units with Axial Fan

EHN/CHNAIR COOLED SPLIT UNIT

9 ModelsCooling / Heat PumpFrom 6.0 to 29.2 kW

Condensing unit with radial fan

EVN/CVNAIR COOLED SPLIT UNIT

11 ModelsCooling / Heat PumpFrom 19.4 to 85.4 kW

Condensing unit with radial fan

EHN/CHN

EVN/CVN

6 7.5 9.7 12.1 15.7 19.5 21.9 24.6 29.2

064 084 104 124 164 204 224 254 304

19.4 24.5 29.1 32.3 37.7 42.7 49.1 58.1 64.6 75.4 85.4

204 254 304 354 384 454 504 604 654 754 904

DK/DN12.0 14.5 17.5 19.1 21.0 28.5 36.0 37.5 44.0 56.0 69.1 83.0

125 155 185 205 255 305 405M 405 505 605 755 905

All performances in kilowatt

Page 27: AC Airwell Product Range 2010-11

27

CONDENSINGUNITS

CDNCONDENSING UNITS

8 Cooling modelsFrom 18.6 to 83.0 kW

In combination withany evaporator

WATER COOLEDAND DX DUCTEDINDOOR UNITS

HEATING UNITS WESTHERMHEATING UNIT

7 Models

Cooling / Heat PumpFrom 7.5 to 179 kW

HRWWATER SOURCE HEAT PUMP

13 Models

Cooling / Heat PumpFrom 1.94 to 29.9 kW

CDN18.6 27.8 36.0 35.1 44.4 55.6 69.1 83.0

205 305 405M 405 505 605 705 905

WESTHERM7.5-22.1 17.3-47.4 23.7-66.0 31.0-87.1 41.6-116.0 57.0-155.0 62.7-179.0

35 45 50 55 65 70 110

HRW

1.94 2.34 2.97 5.28 5.92 8.69 10.14 11.37 12.97 14.34 17.2 21.8 29.9

7 9 12 19 24 30 36 42 48 60 72 96 120

All performances in kilowatt

Page 28: AC Airwell Product Range 2010-11

28

MONOBLOC-UNITS

HANMONOBLOC

7 ModelsHeat PumpFrom 9.8 to 31.0 kW

Condensing Unit wit Axial Fan for outdoor installation

AHNMONOBLOC

9 ModelsCooling / Heat PumpFrom 6.0 to 29.2 kW

Condensing Unit with Radial Fan for indoor installation

AVNMONOBLOC

11 ModelsCooling / Heat PumpFrom 19.4 to 85.4 kW

Condensing Unit with Radial Fan for indoor installation

AVN

19.4 24.5 29.1 32.3 37.7 42.7 49.1 58.1 64.6 75.4 85.4

204 254 304 354 384 454 504 604 654 754 904

HAN

AHN

9.8 13.0 14.5 16.8 18.9 25.4 31.0

6.0 7.5 9.7 12.1 15.7 19.5 21.9 24.6 29.2

10 13 15 17 19 25 31

064 084 104 124 164 204 224 254 304

All performances in kilowatt

Page 29: AC Airwell Product Range 2010-11

29

CLOSE CONTROL

CWCLOSE CONTROLSCOLD WATER

12 Cooling modelsFrom 15.1 to 152.8 kW

CDCLOSE CONTROLSAIR COOLED / WATER COOLED

10 Cooling modelsFrom 10.6 to 32.1 kW

MDCLOSE CONTROLSAIR COOLED / WATER COOLED

14 Cooling modelsFrom 20.5 to 102.9 kW

CW

15.1 25.8 35.5 49.8 57.8 39.4 49.2 60.8 83.0 94.8 110.8 152.8

021 031 041 051 061 042 052 062 082 102 112 152

CD

10.6 13.4 17.0 21.2 23.5 29.4 32.9 21.6 25.9 32.1

031 041 051 061 071 091 101 072 082 102

MD

20.5 26.4 31.4 36.1 45.1 55.1 29.0 35.2 47.2 52.6 63.9 69.7 88.8 102.9

061 071 091 101 131 151 082 102 132 152 182 202 262 302

All performances in kilowatt

Page 30: AC Airwell Product Range 2010-11

30

VERTICAL CABINETS

X-ARVERTICAL AIR CABINETS

6 Cooling modelsFrom 9.7 to 55.0 kW

X-AOVERTICALWATER CABINETS

6 Cooling modelsFrom 8.0 to 45.7 kW

- 9.7 16.2 19.8 29.0 38.9 55.0

8.0 11.7 18.0 23.0 32.4 45.7 -

CX 25 1100 1900 2450 3250 4650 6450MODELX-AR

X-AOAll performances in kilowatt

Page 31: AC Airwell Product Range 2010-11

31

ROOFTOPUNITS

RT ROOFT@IRROOFTOP WEATHER PROOF COMPACT UNIT

7 ModelsCooling: 41.5 – 108.4 kWHeating: 41.0 – 106.1 kW

Galvanised, coated construction, 25 mm insulation

RTC ROOFTECHROOFTOP WEATHER PROOF COMPACT UNIT

7 ModelsCooling: 101 – 221 kWHeating: 97.4 – 220 kW

Aluminium construction, double-layer, 50 mm insulationgas heating, heat recovery, 2-3 flap system

MODELRT ROOFT@IR

RTC ROOFTECH

41.5 50.9 59.8 67.7 84.9 96.6 108.4 - - - - - -

- - - - - 101.0 - 115.2 135.4 158.1 176.4 198.8 221.1

40 50 60 70 80 100 110 120 140 160 180 200 220

All performances in kilowatt

RT4DROOFTOP WEATHER PROOF COMPACT UNIT

10 ModelsCooling: 16.2 – 207.8 kWHeating: 14.4 – 183.2 kW

Aluminium construction, double-layer 50 mm, gas heating,thermo-dynamic heat recovery, 4 flap system

RT4D

16.2 29.2 33.4 50.4 58.4 83.9 103.9 150.7 167.5 207.8

20 40 60 80 100 140 180 240 280 380

Page 32: AC Airwell Product Range 2010-11

32

TEMP@IRCENTRALIZED AIR HANDLING UNIT FOR INDOOR & OUTDOORINSTALLATION

10 ModelsFrom 500 to 30,000 m3/h

Panel thickness 50 mm with base frameCertified in accordance with DIN EN 1888

@IRSTEELCENTRALIZED AIR HANDLING UNIT FOR INDOOR & OUTDOORINSTALLATION

15 ModelsFrom 1,500 to 100,000 m3/h

Panel thickness 25-50 mm. Also available without base framedepending on size. Certified in accordance with DIN EN 1886

TEMP@IR

@IRSTEEL

1,500 – 30,000 m3/h

1,500 – 110,000 m3/h

20 40 60 90 120 160 200 240 300 360

20 40 60 90 120 160 200 240 300 360 400 500 700 900 1000

AIR HANDLINGUNITS

Page 33: AC Airwell Product Range 2010-11

33

AirwellChilled Water Terminal Unit, Residential HeatPumps and Chiller

More and more customers are opt for water-cooled air conditioners, even in the residencial

sector. The AIRWELL water-cooled range is made to perfectly suit the various customer require -

ments. It offers you Airwell water chillers that are completely set up on refrigerant and water

side and can be delivered at short notice. The water-cooled room air conditioners are known for

their wide variety, whether it is a floor/ceiling, ducted, wall-mounted or cassette design.

Our technicians and engineers will be pleased to support you in planning and designing of

larger facilities.

Page 34: AC Airwell Product Range 2010-11

34

CASSETTEUNITS

K-OGCASSETTE UNIT

5 ModelsCooling / HeatingFrom 2.2 to 10.4 kW

KCO COANDACASSETTE UNIT

3 Models Cooling / HeatingFrom 0.93 to 4.34 kW

WALL MOUNTEDUNITS

XLM-OGWALL MOUNTED UNIT

3 ModelsCooling / HeatingFrom 1.85 to 3.66 kW

INDUCTIONUNITS

AQU@BEAMDUCTED UNIT

20 Models Cooling / HeatingFrom 58 to 1167 W

MODELXLM OG

K-OG

1.85 kW 2.2 kW - 3.6 kW - -

- 2.2 kW (1) 3.5 kW (1) 5.0 kW (1) 6.44 kW (1) 10.2 kW (1)

7 9 12 18 30 45

58-334 W 70-362 W 77-401 W 85-468 W 97-533 W 105-601 W

1W-12 1W-15 1W-18 1W-21 1W-24 1W-27

52-356 W 62-391 W 77-444 W 92-481 W 102-533 W 113-623 W 129-711 W 139-800 W 169-889 W

2W-06 2W-09 2W-12 2W-15 2W-18 2W-21 2W-24 2W-27 2W-30

49-517 W 76-822 W 76-822 W 93-1167 W 93-1167 W

4W-06 4W1-12 4W2-12 4W1-18 4W2-18

KCO

AQU@BEAM

1.74 kW (2) 2.87 kW (2) 4.34 kW (2)

60 90 120

(1) 2-pipe heat exchanger (2) Highest fan speed

Page 35: AC Airwell Product Range 2010-11

35

DUCTED UNITS

VH2NDUCTED UNIT

9 Models Cooling / HeatingFrom 0.36 to 27.72 kW

VHFDUCTED UNIT

4 ModelsCooling / HeatingFrom 3142 to 9498 W

VPXDUCTED UNIT

4 Models Cooling / HeatingFrom 6700 to 5737 W

VH2N2.85 kW (1) (2) 5.31 kW (1) (2) 7.48 kW (1) (2) 9.82 kW (1) (2) 15.05 kW(1) (2) 18.69 kW(1) (2) 21.32 kW(1) (2) 24.07 kW(1) (2) 27.72 kW(1) (2)

03 05 07 10 15 18 21 24 27

(1) 2-pipe heat exchanger (2) Highest fan speed

WESPAKDUCTED UNIT

6 ModelsCooling 3.0 – 45.0 kWHeating 9.0 – 57.0 kW

WESPAK3 kw 6 kW 12 kW 26 kW 36 kW 45 kW

1.39 2.69 3.99 4.05 5.05 6.05

VHF543-3142 W 1490-4336 W 3421-7361 W 5061-9498 W

01 05+ 10 12

VPX1400-6007 W 1400-6007 W 1400-6007 W 1260-5737 W

Config. I Config. J Config. L CONFIG. U

Page 36: AC Airwell Product Range 2010-11

36

FAN COILUNITS

AQU@FAN IIAWC-A

8 ModelsCooling / HeatingFrom 1.1 to 10.74 kW

AQU@FAN IIAHC-A

8 Models Cooling / HeatingFrom 1.1 to 10.74 kW

AQU@FAN IIAWN-A

9 Models Cooling / HeatingFrom 1.1 to 10.74 kW

AQU@FAN IIAHN-A

9 ModelsCooling / HeatingFrom 1.1 to 10.74 kW

MODELAWC-A/AHC-A

AWN-A/AHN-A

- 2.01 2.44 3.46 5.01 5.73 - 9.04 10.74

1.14 2.01 2.44 3.46 5.01 5.73 - 9.04 10.74

1030 2030 3030 4030 5030 6030 7030 8030 9030

2-pipe heat exchanger (3 rows) - Low fan speed - All performances in kilowatt - Chilled water temp. 7/12°C, Room temp. 27°C/48% rh

Page 37: AC Airwell Product Range 2010-11

37

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600

MQH

AQL/AQH

AQVL/AQVH

VLS/VLH

AQTL/AQTH

SLS R134a

5.4-17.8 kW

40 -75.8 kW

84-137 kW

136-308 kW

289-626 kW

293-1646 kW

CWP

RWC/RWR

SWS/SWR

7.6-131.7 kW

160.8-312.3 kW

271.8-1,118 kW

AQVC

VLC

AQTC

92-151 kW

154-347 kW

326-706 kW

AQCL/AQCH 24.9-125 kW

AIR COOLED CHILLER WITH RADIAL FAN

WATER COOLED CHILLER

AIR COOLER CONDENSING UNITS

kW

AIR COOLED CHILLER WITH AXIAL FAN

SPH/SPH-R

PAC+/PAC+R

PAC HT

8-14 kW

8-14 kW

6.5-8.9 kW

RESIDENTIAL HEAT PUMP

POWERFUL WATER-COOLED RANGE FROM 5.6 KW TO 1.6 MW!

ALL CHILLER ARE EUROVENT CERTIFIED!

Page 38: AC Airwell Product Range 2010-11

38

RESIDENTIALHEAT PUMP

SPH/SPH-RSPLIT AIR TO WATERHEAT PUMPSREVERSIBLE/RELIEF OFBOILER

3 Models Cooling / Heat PumpFrom 8.1 to 14.1 kW

PAC+/PAC+RAIR/WATER HEAT PUMPS

3 Models Cooling / Heat PumpFrom 8.1 to 14 kW

PAC HTHIGH TEMPERATURE (UPTO 65°C) HEAT PUMPSWITH PRODUCTION OFSANITARY HOT WATER

3 Heat Pump modelsFrom 12 to 17.9 kW

MODELSPH / SPH-R 8.1 11.2 14.1

8 10 12

MODELPAC+ / PAC +R 8.1 11.2 14.0

8 10 12

MODELPAC HT 12 14.3 17.9

12-6 14-7 18-9

All performances in kilowattHeating capacity for air temperature 7°C, water temperature 30/35°C

Dual compressor heating capacity / exterior ambient temperature of 7°C / water system 40/50°C

Page 39: AC Airwell Product Range 2010-11

39

AQL/AQHAIR-COOLED WATERCHILLERSAXIAL FAN

10 Models Cooling / Heat PumpFrom 19 to 76 kW

AQVL/AQVCAIR-COOLED WATERCHILLERAXIAL FAN

6 Models Cooling / Heat PumpFrom 83.6 to 137.1 kW

AIR-COOLEDWATERCHILLER

MQHAIR-COOLED WATERCHILLERSAXIAL FAN

7 Models Cooling / Heat PumpFrom 5.4 to 17.8 kW

MODELMQH 5.4 7.6 9.7 12.1 13.1 15.1 17.8

6 8 10 12 14 16 18

MODELAQL/AQH 19.1 25 31 36 40 44 51 60 68 76

20 25 30 35 40 45 50 60 65 75

MODELAQVL/AQVH 83.6 93.7 103 111 122 137

85 95 105 115 125 140

All performances in kilowatt

Page 40: AC Airwell Product Range 2010-11

40

VLS/VLHAIRCOOLED WATERCHILLER WITH SCROLL COMPRESSOR

8 Models Cooling / Heat PumpFrom 136 to 308 kW

AQTL/AQTHAIRCOOLED WATERCHILLER WITH SCROLL COMPRESSOR

7 Cooling modelsFrom 289 to 621 kW

AIR-COOLEDWATERCHILLER

SLSAIRCOOLED WATERCHILLER WITH SCREW COMPRESSOR

23 Cooling modelsFrom 293 to 1646 kW

R-134a

Page 41: AC Airwell Product Range 2010-11

41

AQCL/AQCHAIRCOOLED WATER CHILLER WITHRADIAL FAN

11 Models Cooling / Heat PumpFrom 24.9 to 125 kW

MODELVLS/VLH 136 154 176 199 229 251 280 308

524 604 704 804 904 1004 1104 1204

MODELAQTL/AQTH 289 336 362 407 473 553 626

1206 1355 1506 1656 1806 2106 2406

MODELSLS 293.0 326.2 365.6 410.6 455.5 480.5 513.6 546.8 620.3 660.0 718.6 758.8

1402 1602 1802 1902 2002 2202 2502 2702 3002 3202 3402 3602

823.3 908.8 962.4 1027.2 1093.6 1167.1 1240.6 1320.0 1437.2 1517.2 1646.6

4202 4602 4802 5004 5404 5704 6004 6404 6804 7204 8404

MODELAQCL/AQCH 24.9 28.8 33.7 39.6 46.4 56.3 67.5 76.5 99 114 125

25 30 35 40 50 60 70 80 100 120 130

All performances in kilowatt

Page 42: AC Airwell Product Range 2010-11

42

WATERCOOLED WATERCHILLER

CWPWATER COOLED WATER CHILLER WITH SCROLL COMPRESSOR

13 Models Cooling / Heat PumpFrom 7.6 to 136 kW

RWC/RWR*WATER COOLED WATER CHILLER WITH SCROLL COMPRESSOR

6 Cooling modelsFrom 160.8 to 312.3 kW

*RWR = for external condensers. Split design

Page 43: AC Airwell Product Range 2010-11

43

*SWR = for external condensers

SWS/SWR*WATER COOLED WATER CHILLER WITH SCREW COMPRESSOR

15 Cooling modelsFrom 271.8 to 1,118.2 kW

R-134a

MODELRWC/RWR 160.8 186.5 210.6 263.6 283.7 312.3

170 200 240 280 320 360

MODELSWS/SWR R134a 271.8 362.4 440 529.3 564.7 600 639.2 678.4 716 784.4 841.7 898.9 962.1 1,040.2 1,118.2

1602 1902 2202 2212 2352 2502 2652 2802 3012 3202 3412 3602 4212 4602 4802

MODELCWP 7.6 9.2 13.3 16.3 19.7 28.0 33.7 40.7 55.8 67.6 87.7 111.9 136.2

02 03 04 05 06 07 09 12 18 21 25 30 35

All performances in kilowatt

Page 44: AC Airwell Product Range 2010-11

44

CONDENSINGUNITS

AQVCAIR COOLED CONDENSING UNITS

6 Cooling modelsFrom 92.1 to 151.0 kW

AQTCAIR COOLED CONDENSING UNITS

7 Cooling modelsFrom 326.0 to 705.6 kW

Page 45: AC Airwell Product Range 2010-11

45

VLCAIR COOLED CONDENSING UNITS

8 Cooling modelsFrom 154 to 347 kW

MODELAQTC 326.0 379.0 408 459 533 623.5 705.6

1206 1355 1506 1656 1806 2106 2406

MODELAQVC 92.1 103.2 113.2 121.8 134.7 151.0

85 95 105 115 125 140

MODELVLC 154 174 199 224 258 283 315 347

524 604 704 804 904 1004 1104 1204

All performances in kilowatt

Page 46: AC Airwell Product Range 2010-11

46

Page 47: AC Airwell Product Range 2010-11

47

Subject to technical modifications, typesetting and printing errors

The manufacturer makes every effort to continuously improve his products and make optimal adaptations to suit theconditions of the respective country of use. For this reason it shall retain the right to undertake technical modifications to theproducts without prior notification.

Page 48: AC Airwell Product Range 2010-11

Range Program / 10-08/1000094 JKP PR

B - A

.2 G

B

Airwell GroupAirwell Group (Headquarter)address:1 bis avenue du 8 Mai 194578284 Guyancourt CedexFrancewww.airwell.com