Product catalogue A25 Absorption Cooling Systems

Upload: others

Post on 12-Mar-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

Product catalogue A25

AbsorptionCooling Systems

Page 2: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

COOLINGPOWERED BY NATURE

PRODUCT FEATURESLow electricity consumptionreduces energy costs.

Purix cooling and air conditioningsystems help you building a greentomorrow without compromising thebasic needs for a comfortable andhealthy indoor environment - whereand when you need it.

Designed with conventional absorptioncooling technology, the systems convertsupply of low temperature heat sourcesinto cooling.Replacing expensive electricity withinexpensive and low quality energysources for generation of cooling, is agreat opportunity for turning districtheating into district cooling or solarheating into solar cooling, and forreducing costs,environmental impactand greenhouse gas emissions.

The patented system design is ideal forreplacing traditional split cooling and airconditioners in a wide range ofapplications, e.g. retail, offices,households, clinics, hospitals, sportsfacilities, institutions, hotels, restaurantsand bars, schools, storages or data &telecom installations.

A flexible product designrecognizes the need for integrationwith the interior design and architecture,and supports various types of indoorunits.Depending on the building layoutand cooling demand, the systemssupport mono- and multi splitinstallations, and may be configuredinto systems with increased capacity.

Applies pure water as naturalrefrigerant.

Flexible design for match withinterior design and architecture- various fan coil types,- mono & multi split design.

Low noise level.

Cooling based on lowtemperature thermal energysources instead of electricity(solar thermal energy, districtheating, waste heat etc.)

Gently heats and cools withoutdrying out the indoorenvironment.

FLEXIBLE DESIGN

Page 3: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

1

2

1

2 - Indoor unit (Fan coil)

- Outdoor unit (Chiller)

Thermal energy source(district heating, solarheating, central heating,waste heat etc.)

OUTDOOR

INDOOR

A PURIX system is designed for operationwith any available thermal energysource, and consists of two main parts:

Page 4: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

SPECIFICATION

Type Chiller for mono- & multi split installation(up to 3 indoor units)

Technology 1-stage absorption chiller (LiBr-H2O), air cooled

Refrigerant R718 (water)

Chilled Water

Chilled water (freeze protected)2,5 (nominal at 35°C outdoor temperature)13 / 18 (supply/return)0,5G1/2”

[kW][°C][BarG]

FluidCapacityTemperaturePressure, max.Connections

External heat supply

PowerTemperaturePressure, max.Connections

[kW][°C][BarG]

3,1 (at 35°C outdoor temperature, ∆T = 5°C)Varies with outdoor temperature*3G1/2”

Electricity demandNoise level

[W]

[dB(A)]

<150

<45

*Thermal energy source, supply temperature requirements

PURIX Chiller A25

Outdoor temperature [°C]

Min

imum

tem

pe

ratu

re[°C

]

Page 5: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

SPECIFICATION

Cooling capacity [kW]

High Wall Cassette Floor/ceiling

2,5

Electricity consumption [W] <50 <110 <80

Air flow [m³/h] 500/410/360 600/560/530 1000/750/500

Noise level <48 <47 <47

[cm] 94x20x30 84x84x19 130x19x60

[dB(A)]

Dimensions (LxWxH)

[kg] 13 27 34Weight

Connections

[Inch/mm] 1/2" / 12,7 3/4" / 19,05- Chilled water

[mm] 15,6 33 33- Drain

3/4" / 19,05

User interface, std./optional Remote / wired controller

High Wall mounted Cassette Floor/Ceiling

PRODUCT FEATURES

Silent mode

Multi speed fan

Auto cleaning

Washable filter

Condensate pump

Fan coils*

*Other fan coil types an and capacities are available upon request.

2,5 2,5

Page 6: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

CONNECTIONS

Heat source, supply

Heat source, return

Electricity, 230VAC, 50Hz

Chilled Water, supply

Chilled Water, return

Optional

Page 7: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

650mm

DIMENSIONSPURIX Chiller A25

450mm

1400

mm

Page 8: Absorption Cooling Systems - Sustainable Development...Designed with conventional absorption cooling technology, the systems convert supply of low temperature heat sources into cooling

PURIX ApS

Langogade 172100 Copenhagen ODENMARK

t: +45 7734 2280e: [email protected]: www.purix.com

We believe that people should experience a comfortableand healthy indoor environment, without compromisingsustainability.PURIX provides attractive solutions supporting consumersand organisations in building a Green tomorrow.

PURI

XC

ata

log

ueA2

5EN

ver0

1b

About PURIX