Henan Dafang Dingsheng Flow Instrument Co., Ltd is a professional company of automatic instrument production and supporting. The company integrates the R&D, design, production, manufacturing and sales services of industrial automatic instruments and related products.
The company covers an areas of more than 2000 square meters,with 100 employees,15 core technical personnel and 20 foreign trade sales elite teams.We have the national leading production equipment.Our main products include electromagnetic flow meter,vortex flow meter,throttling device,turbine flow meter,ultrasonic flow meter and various flow supporting products.Our products have complete specifications and various forms,and can meet customers special customized needs.
After years of development, the flow meter products produced by our company enjoy very high market reputation in China, and has been supplying domestic foreign trade enterprises for export for many years.
We started to set up our own international trade department in 2018 with complete product certificates and perfect sales team. Up to now, we have established long-term cooperative relations with many countries.
As one China gold supplier, the factory covers an area of more than 20000 m2,
with 200 employees, 15 core technical personnel and
20 foreign trade sales elite teams.
The company has exported to at least 30 countries.
The annual output value can reach 20 million, 50
customers have visited the factory. The favorable rate
can reach 99%.
Accept OEM,24 hours online sales team,after-sales
team response within 48 hours,rapid delivery,delivery time guarantee,no limit for
MOQ.
The company has advanced CNC machining equipment and professional processes to ensure the quality and detail of the products. At the same time, we accept
customization and can produce products according to customers' requirements.
The company has a strict quality inspection
department to control every detail of production, Provide
customers with quality products.
Our professional enginner can guide you the Installation
and commissioning work, quality warranty 12 months.
99%
China professional flowmeter manufacturer China professional flowmeter manufacturer
3 4
Electromagnetic flowmeter is a kind of high precision and high reliability flowmeter. It is used to measure the volume flow of conductive liquid and slurry in a closed pipe, and widely used in iron and steel, electric power, petroleum, chemical, coal, metallurgy, mineral, paper, water supply, food, medicine and other industries.
5 6
DFLD-YGD Electromagnetic Flowmeter
China professional flowmeter manufacturer China professional flowmeter manufacturer
(Integrated Type)
7 8
DFLD-FGDElectromagnetic Flowmeter
China professional flowmeter manufacturer China professional flowmeter manufacturer
(Remote Type)
9 10
The accuracy will be unaffected by the change of fluid density, viscosity, temperature, pressure and conductivity.There are no parts which will impede flow in the measurement tube, no pressure loss, and the need of straight section is lower.The converter use display, it is easy to read the data in the straight sun and dark room.Setting parameters through infrared thouch button, so we can set parameters safely without opening the cover of converter under harsh environment.The flowmeter has bidirectional measuring system and is installed with three integrators: forward total volume, reverse total volume and total difference; it can display forward flow and reverse flow volume in varied outputs: current, pulse, digital communication, HART;The converter has self-inspection and self-diagnosis function;The sensor of high pressure electromagnetic flow meter use PFA and net lining material, have the advantage s of high pressure resistance, anti-negative pressure. It specially used in petrochemical, mineral, etc. Explosion-proof type flow meter can used in corresponding explosion- proof area.
The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. That is: Conductive liquid moves in the magnetic field as a cutting magnetic line, an induced electromotive force is generated in the conductor.
When measuring flow, the fluid flows through a magnetic field that is perpendicular to the direction of flow. The flow of the conductive liquid induces a voltage signal that is proportional to the average flow rate. Its induced voltage signal is detected by two electrodes in direct contact with the liquid, and transmitted to the amplifier through the cable, then converted into a uniform current output signal.
The intelligent converter of Chinese and English display adopts 16-bit embedded microprocessor.Full digital processing, with bidirectional flow measurement function, instantaneous flow, positive and reverse accumulations and difference calculations, used to measure volume flow in conducting media such as clear water, sewage, acid, alkali, salt solution or liquid-solid two-phase fluid.
Features:
Measuring principle:
Characteristics and scope of application:
E=K*B*V*D
K: Instrument constant
B: Strength of magnetic induction
V: The average flow rate in the cross-section of measuring the tube
D: Inner diameter of measuring tube
Technical performance parameter:
Main Power AC220V 50HZ / DC24V
Power Consumption <15W (And set with sensor supporting power consumption )
Display And Push Buttons
English and Chinese display, it can display the instantaneous flow, total flow and percentage of flow as well as alarm display, four thin-film touch nubs, which is used to data set.
Accumulator Forward total quantity, reverse total quantity
Output Signal
Analog output Bi-direction with two ways, Isolation 0-10mA/4-20mA
Load resistor: 0-10mA; 0-1.5KΩ; 4-20mA; 0-750Ω
Frequency output
Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50mA when the transistor is turned on
Alarm output
Two outputs from the collectors of photoelectric isolate transistors are for alarm signals. The external voltage must be lower than 35V and the max output current is 250mA when the transistor is turned on. Alarm status: Activates when the measured pipes are empty, the excitation circuits are broken or the volume of flow rate exceeds the value designed limits.
Pulse output
For pulse output in forward and reverse flow measurement, upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P. The width of pulse can be set to 20ms or squired wave from automatically. The collector of transistor with photoelectric is open circuited. The external voltage must be lower than 35 V and maximum output current is 250mA when the transistor is turned on.
Accuracy ±0.5% of the value displayed, ±0.3% or ±0.2% is optional.
Damping Time Constant Continuous variable from 0-100 s (90%)can be selected by group
CommunicationRS232 ,RS485 or HART Communication are optional,with lighting resistance
Power FailureAn anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years)
Protection Grade IP65
Ex-proof Mark Exd [ia]iaⅡcT5
11 12
Nominal Diameter DN6~DN3000mm
Nominal Pressure 0.6~4.0MPa
Main Power AC220V 50HZ / DC24V /3.6V
Accuracy ±0.5%, ±0.3% or ±0.2% is optional
Output Signal Analog output, Frequency output, Alarm output, Pulse output
Liner Material Neoprene, Polyurethane, Polysilicone Rubber, PTFE, F46, PFA
Electrode Type General type, scraper type and replaceable type
Electrode MaterialSUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum-iridium alloy, Stainless steel covered with tungsten carbide
Medium Temperature
Integrated type -20°C~+70°C
Remote type
Neoprene &Polyurethane Liner
-20°C~+60°C
PTFE Liner /PFA Liner /F46 Liner
-40°C~+180°C
Ambient Temperature -25°C ~+ 60°C
Ambient Humidity 5~100%RH(relative humidity)
Medium Electrical Conductivity
≥20us/cm
Measuring Range 1500:1,flow rate<15m/s
Structure Type Integral type, remote type, submersible type, ex-proof type
Connection Type Flange Type / Clamp Type
Protection Grade IP65, IP67, IP68(optional)
Ex-proof Mark Exmd ⅡCT4
Product Standard JB/T 9248-1999 Electromagnetic Flowmeter
Technical performance parameter:
Corrosion resistance of electrode materials:
Lining Materials Main Features Scope Of Application
PTFE
1.One of the most stable chemical properties in plastics. It is resistant to boiling hydrochloric acid, sulfuric acid and aqua regia, but also resistant to concentrated acids and various organic solvents.2.Poor abrasion resistance
Applicable in mediums of strong corrosive,such as,concentrated acid、alkali and so on. Temperature range: ﹣ 40℃~﹢170℃
F461. It's corrosion resistance same as PTFE.2. low abrasion resistance.3. with strong anti-negative pressure ability.
The features of strong corrosive resistance same as PTFE can used to measure mediums with low abrasion Temperature range: ﹣ 40℃~﹢160℃
Polyurethane
1. Excellent abrasion resistance (Ten times equivalent to natural rubber).2.Poor in acid resistance and alkali resistance.3.Cannot be used with water mixed with organic solvents.
Those neutral medium with strong abrasion, like Slurry、coal slurry、mud, etc. Temperature range: ﹣ 20℃~﹢ 60℃
Polysilicone Rubber
1. Excellent elasticity, high tearing force, high pressure resistance.2. Can't resistant the corrosion of all acid, alkali,salt medium.
Water Temperature range: ﹣20℃~﹢ 180℃
PFA It's corrosion resistance same as PTFE, with strong anti-negative pressure ability.
It can used under negative pressure state Temperature range: ﹣ 40℃~﹢ 160℃
Neoprene
1. Excellent elasticity, high tearing force, good abrasion resistance.2. Resistant to the general low concentrated acid, alkali,salt medium corrosion, can't resistant the corrosion of oxidizing media.
Water, sewage, weakly abrasive mud, pulpTemperature range: ﹣ 20℃~﹢60℃
Electrode Material Corrosion Resistance
SUS316For industrial water, domestic water, sewage, corrosive media, widely used in petroleum, chemical, steel, etc industrial sector and municipal, environmental protection field.
Hastelloy B(HB)
Hydrochloric acid of all concentrations below the boiling point has good corrosion resistance, and also resistance the corrosion of sulfuric acid, phosphoric acid, hydrofluoric acid, organic acids and other non-oxidizing acid, alkali, non-oxidizing salt solution.
13 14
Hastelloy C(HC)
Can resistance the corrosion of oxidative acid, such as nitric acid, mixed acid or chromic acid and sulfuric acid mixed medium, but also resistant to oxidizing salts such as Fe +++, Cu ++ or other oxidants such as hypochlorite solution above sea level, sea water corrosion
Titanium (Ti)
It can resistance the corrosion of seawater, various chlorides and hypochlorites, oxidative acids (including fuming sulfuric acid), organic acids, alkalis, etc, and is cannot resistance the corrosion of pure reducing acids (such as sulfuric acid and hydrochloric acid). However, if the acid contains oxidants (such as nitric acid, Fe +++, Cu ++), the corrosion is greatly reduced.
Tantalum (Ta)
Has excellent corrosion resistance, and similar with glass, in addition to hydrofluoric acid, fuming nitric acid, alkali, it can resistance the corrosion of almost all chemical media (including hydrochloric acid, nitric acid and sulfuric acid under 150°C and aqua regia).
Platinum-iridium Almost applies to all chemicals, but not aqua regia and ammonium salts.
Stainless Steel Covered With Tungsten Carbide
Applicable in mediums of no corrosive and high abrasion.
Shape and installation dimensions:
Shape and installation dimensions:
DN15~DN150, 1.6 & 4.0MPa Sensor and integrated outline drawing
Dimensions and weight Flange size (GB / T9119)Nominal Diameter
(mm)Nominal Pressure
(MPa)
Outer DiameterWeight(kg) Length of Flowmeter
(Including Lining)D H
6
4.0
200 90 220 610 200 90 220 615 200 95 220 820 200 105 220 1025 200 115 223 1232 200 140 240 1340 200 150 250 1450 200 165 263 1565
1.6
250 185 283 1880 250 200 290 20100 250 235 318 25125 250 270 350 28150 300 300 380 30200 350 340 430 50250 450 405 495 70300
1.0
500 460 547 95350 550 520 602 120400 600 580 665 140450 600 640 720 160500 600 715 783 200600 600 840 897 280
DN L W H
Reference Weight(kg)
Integrated Type
Sensor
15 200 140 147 10 7
20 200 140 154 12 9
25 200 140 156 14 11
32 200 168 166 15 12
40 200 176 172 16 13
50 200 176 191 17 14
65 250 214 200 25 22
80 250 214 218 29 26
100 250 230 242 31 28
125 250 281 277 36 33
150 300 281 302 41 38
DNPressure 1.6 MPa Pressure 4.0MPa
D d1 d0 n b D d1 d0 n b
15 95 65 14 4 16 95 65 14 4 16
20 105 75 14 4 18 105 75 14 4 18
25 115 85 14 4 18 115 85 14 4 18
32 140 100 18 4 18 140 100 18 4 18
40 150 110 18 4 20 150 110 18 4 20
50 165 125 18 4 20 165 125 18 4 20
65 185 145 18 4 20 185 145 18 4 22
80 200 160 18 8 22 200 160 18 8 22
100 220 180 18 8 22 235 190 22 8 26
125 250 210 18 8 22 270 220 26 8 26
150 285 240 22 8 24 300 250 26 8 28
15 16
DN200~DN600, 1.0 & 1.6 MPa Sensor and integrated outline drawingDN700~DN3000, 0.6 & 1.0 MPa Sensor outline drawing
DN L Hφ~Weight
(kg)
200 350 362 45
250 450 412 50
300 500 472 60
350 500 522 145
400 500 572 180
450 550 626 215
500 550 676 245
600 600 776 335
DNPressure 1.0 MPa Pressure 1.6 MPa
D d1 d0 n b D d1 d0 n b
200 340 295 22 12 26 340 295 22 8 24
250 405 355 26 12 28 395 350 22 12 26
300 460 410 26 12 32 445 400 22 12 28
350 520 470 26 16 35 505 460 22 16 30
400 580 525 30 16 38 565 515 26 16 32
450 640 585 30 20 42 615 565 26 20 35
500 715 650 33 20 46 670 620 26 20 38
600 840 770 36 20 52 780 725 30 20 42
Dimensions and weight Flange size (GB / T9119)
Note: 1. DN700~DN3000 without integrated type. 2. DN700 ~ DN1600 separated explosion-proof sensor has the same appearance as conventional instruments.
DN L Hφ~Weight
(kg)
700 700 866 435
800 800 966 545
900 900 1076 655
1000 1000 1200 810
1200 1200 1406 875
1400 1400 1632 1235
1600 1600 1832 1555
1800 1800 2036 2085
2000 2000 2236 2610
2200 2200 2436 3210
2400 2400 2636 3910
2600 2600 2836 4280
2800 2800 3036 5000
3000 3000 3236 5600
DNPressure (MPa)
D d1 d0 n b
700
1.0
895 840 30 24 30800 1015 950 33 24 32900 1115 1050 33 28 341000 1230 1160 36 28 34700
0.6
860 810 26 24 26800 975 920 30 24 26900 1075 1020 30 24 261000 1175 1120 30 28 261200 1405 1340 33 32 281400 1630 1560 36 36 321600 1830 1760 36 40 341800 2045 1970 39 44 362000 2265 2180 42 48 382200 2475 2390 42 52 422400 2685 2600 42 56 442600 2905 2810 48 60 462800 3115 3020 48 64 483000 3315 3220 48 68 50
Dimensions and weight Flange size (GB / T9119)
17 18
Flow-Velocity Table Flow Rate m/s Flow m3/h
DN mm
0.01(Minimum )
1 2 3 4 515
(Maximum)
10 0.0085 0.2826 0.5652 0.8478 1.1304 1.4130 4.2390
15 0.0064 0.6362 1.2723 1.9085 2.5447 3.1809 9.5426
20 0.0113 1.1310 2.2619 3.3929 4.5239 5.6549 16.9646
25 0.0177 1.7671 3.5343 5.3014 7.0686 8.8357 26.5072
40 0.0452 4.5239 9.0478 13.5717 18.0956 22.6195 67.8584
50 0.0707 7.0686 14.1372 21.2058 28.2743 35.3429 106.0288
65 0.1195 11.9459 23.8918 35.8377 47.7836 59.7295 179.1886
80 0.1810 18.0956 36.1911 54.2867 72.3823 90.4779 271.4336
100 0.2827 28.2743 56.5487 84.8230 113.0973 141.3717 424.1150
150 0.6362 63.6173 127.2345 190.8518 254.4690 318.0863 954.2588
200 1.1310 113.0973 226.1947 339.2920 452.3893 565.4867 1696.4600
250 1.7671 176.7146 363.4292 530.1438 706.8583 883.5729 2650.7188
300 2.5447 254.4690 508.9380 763.4070 1017.8760 1272.3450 3817.0351
350 3.4636 346.3606 692.7212 1039.0818 1385.4424 1731.8030 5195.4089
400 4.5239 452.3893 904.7787 1357.1680 1809.5574 2261.9467 6785.8401
450 5.7256 572.5553 1145.1105 1717.6658 2290.2210 2862.7763 8588.3289
500 7.0686 706.8583 1413.7167 2120.5750 2827.4334 3534.2917 10602.8752
600 10.1788 1017.8760 2035.7520 3053.6281 4071.5041 5089.3801 15268.1403
700 13.8544 1385.4424 2770.8847 4156.3271 5541.7694 6927.2118 20781.6354
800 18.0956 1809.5574 3619.1147 5428.6721 7238.2295 9047.7868 27143.3605
900 22.9022 2290.2210 4580.4421 6870.6631 9160.8842 11451.1052 34353.3157
1000 28.2743 2827.4334 5654.8668 8482.3002 11309.7336 14137.1669 42411.5008
1200 40.7150 4071.5041 8143.0082 12214.5122 16286.0163 20357.5204 61072.5612
1400 55.4177 5541.7694 11083.5389 16625.3083 22167.0778 27708.8472 83126.5416
1600 72.3823 7238.2295 14476.4589 21714.6884 28952.9179 36191.1474 108573.4421
1800 91.6088 9160.8842 18321.7684 27482.6525 36643.5367 45804.4209 137413.2627
2000 113.0973 11309.7336 22619.4671 33929.2007 45238.9342 56548.6678 169646.0033
2200 136.8478 13684.7776 27369.5552 41054.3328 54739.1104 68423.8880 205217.6640
2400 162.8602 16286.0163 32572.0326 48858.0490 65144.0653 81430.0816 244290.2448
2600 191.1343 19113.4268 38226.8536 57340.2804 76453.7072 95567.1340 286701.4020
19 20
DFLD-YWS / DFLD-FWSSanitary Electromagnetic Flowmeter
Sanitary / Hygienic electromagnetic flowmeter description:The hygienic electromagnetic flowmeter is an induction instrument to measure the volume flow of conductive medium in the tube with the shell of 304 stainless steel. The electromagnetic flowmeter is not easy to be polluted during use, and can effectively prevent the accumulation of measurement fluid residues in the measuring tube, and can be widely used in mineral water, soy sauce, jam, beer, fruit juice, rice wine, milk and other food production and manufacturing process.
Advantages of sanitary electromagnetic flowmeter:Using a quick connection solution,Easy to install, disassemble, clean and maintain; Unobstructed flow componets inside the pipe,can prevent the accumulation of measured fluid residues effectively. Not affected by the temperature, viscosity, density, and conductivity of the medium in a certain range; Wide range;No mechanical inertia reaction, responsive; It can meet the demand of different caliber in different fields.
Nominal Diameter DN10 ~ DN200mm
Nominal Pressure 0.6 ~ 1.6MPa
Accuracy Indication ±0.5%, ±0.3% or ±0.2% of the optional indication
Medium TemperatureIntegrated type (DFLD-YWS): -10℃ ~ +80℃
Split type (DFLD-FWS): -10℃ ~ +160℃
Electrode MaterialSUS316, Hastelloy B(HB), Hastelloy C(HC),Titanium alloy(Ti), Tantalum alloy(Ta), Platinum-iridium
Protection Grade IP65, IP68 can be optional
China professional flowmeter manufacturer China professional flowmeter manufacturer
21 22
DFLD-YGD / DFLD - FGDInsertion Electromagnetic Flowmeter
Insertion electromagnetic flowmeter description:Insertion electromagnetic flow meter is a new type of flow meter developed on the basis of pipeline electromagnetic flow meter. The whole body is made of stainless steel. According to the NIKURADS principle, it makes the pipe installation easier and reduces the cost consumption. It can be installed on cast iron pipe and cement pipe without stopping water.
Advantages of Insertion electromagnetic flowmeter:The installation is simple, can be opened with the pressure, has the absolute installation advantage and the price advantage. It is suitable for the detection of liquid flow with conductivity above 20cm. The change of conductivity does not affect the change of performance. The movable parts of the flowmeter are easy to install, the converter and sensor are interchangeable, freely changing the measuring range. The flow detection is only related to the depth of insertion.It is very versatile and can be connected with any standard secondary instrument. 4~20mA output,Pulse output,RS485, HART, MODBUS.
Nominal Diameter DN200mm~DN3000mm
Accuracy0.5~10m/s: 1.5% FS; 0.1~0.5m/s: 2.0% FS0.1~10m/s: 2.5% FS (FS refer to 40%-100% full scale flow)
Flow Range 0.1~10m/s
Pressure Resistance
1.6Mpa
Protection GradeIP65 (DFLD-YGD)
IP68 (DFLD-FGD)
Electrode MaterialSUS316, Hastelloy B(HB), Hastelloy C(HC),Titanium alloy(Ti), Tantalum alloy(Ta), Platinum-iridium
PTFE
Neoprene
or
China professional flowmeter manufacturer China professional flowmeter manufacturer
23 24
Vortex FlowmeterVortex flowmeter is a new type of flowmeter with advanced international level based on Carmen vortex principle. It is suitable for measuring superheated steam, saturated steam, general gas and liquid.
FeaturesSimple structure, no moving parts wear;
High accuracy and good reliability, don’t need on-site debugging;
Can be long-distance transmission of flow signals, and computer networking, centralized management;
Unique design of the amplification board, gas or liquid can be used.
25 26
Instrument Caliber
(mm)
Liquid Gas
Measuring Range(m3/h)
Output Frequency Range(Hz)
Measuring Range(m3/h)
Output Frequency Range(Hz)
20 1 ~ 10 40 ~ 396 5.5 ~ 50 218 ~ 1982
25 1.6 ~ 16 32 ~ 325 8.5 ~ 70 172 ~ 1420
40 2.5 ~ 25 13 ~ 130 22 ~ 220 115 ~ 1147
50 3.5 ~ 35 9 ~ 93 36 ~ 320 96 ~ 854
65 6.5 ~ 68 8 ~ 82 50 ~ 480 61 ~ 583
80 10 ~ 100 6 ~ 65 70 ~ 640 45 ~ 417
100 15 ~ 150 5 ~ 50 130 ~ 1100 43 ~ 367
125 27 ~ 275 5 ~ 47 200 ~ 1700 33 ~ 290
150 40 ~ 400 4 ~ 40 280 ~ 2240 27 ~ 221
200 80 ~ 800 3 ~ 33 580 ~ 4960 24 ~ 207
250 120 ~ 1200 3 ~ 26 970 ~ 8000 20 ~ 171
300 180 ~ 1800 2 ~ 22 1380 ~ 11000 17 ~ 136
(400) 180 ~ 3000 5.6 ~ 87 2750 ~ 27000 85 ~ 880
(500) 300 ~ 4500 5.6 ~ 88 4300 ~ 43000 85 ~ 880
(600) 450 ~ 6500 5.7 ~ 89 6100 ~ 61000 85 ~ 880
(800) 750 ~ 10000 5.7 ~ 88 11000 ~ 110000 85 ~ 880
(1000) 1200 ~ 1700 5.8 ~ 88 17000 ~ 170000 85 ~ 880
Measured Medium Gas, Steam
Medium Temp. -20~+320℃
Nominal Pressure 1.6MPa;2.5MPa;4.0MPa;(Other pressure can be customized)
Accuracy ±1.0%,±1.5%
Measuring Range Ratio
1:8-1:30(Standard air condition as reference)
1:8-1:40(Normal Temperature as reference)
Flow Range Gas:4.0-60.0m/s; Steam:5.0-70.0m/s
Diameter(mm) DN15~DN1000
Material Stainless steel 304
Resistance Coefficient Cd≤2.4
Explosion-proof Grade la II CT6
Power Supply 12-24V/DC or 3.6V battery powered
Signal Output
Pulse frequency signal2-3000Hz,Low level≤1V,high level≥6V
Two-wire system 4-20 signal(isolated output),Load≤500
Technical Parameters: Flow-Velocity Table:
27 28
Orifice Plate FlowmeterOrifice plate flowmeter is the simplest and most adaptable product in the throttling device. Its design, manufacture and use are in accordance with the international standard ISO5167 or the national standard GB/T2624.
Features
Technical Parameters
Simple and firm structure, convenient installation, reliable operation.
Can measure all kinds of flow of gas ,steam and liquid,wide application.
Don’t need real flow calibration ,with moderate precision.
Stable performance, easy to adjust, basically do not need to adjust the zero point during use.
Diameter(mm) DN50~1000
Pressure Extraction Method
Angle Pressure(Ring chamber or drilling separately); Flange Pressure; Radial pressure.
Nominal Pressure ≤40Mpa,(when ≥20Mpa ,it can use high pressure lens orifice plate or welding type)
Accuracy ±0.5% ~ ±1.5%
29 30