Greensboro, North Carolina Product OverviewOverhead Distribution Cutouts, Overhead DisconnectSwitches and Capacitor Fuses

greensboro overview.qxp 1/5/2005 11:16 AM Page 1

Page 2: ABB Outdoor 1 Overview

- 2 - - 3 -

Overhead Distribution Cutouts

Product Description Application Options

ICX

• Distribution cutout for use onoverhead distribution system toprovide overcurrent protection

• Fuse tube interchangeable withS&C Type XS, Cooper Type L,and AB Chance Type C cutouts

• 15 kV – 38 kV, up to 16 kA

• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel

• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool

• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)

• Stainless steel seacoast design

• Cutout/arrester combination

• Emission Control Device (ECD)

LBU

• Outdoor loadbreak switch thatcan be used as a fused cutoutfor distribution systems

• Loadbreak interruption isaccomplished by means of aself contained loadbreak arcchute which confines the arcand provides a deionizing action

• 15 kV – 27 kV, up to 16 kA

• Provides overcurrent protectionfor capacitor banks and givesvisible indication that the equip-ment is energized

• Used for switching the magnetiz-ing currents of single and three-phase transformer banks and toswitch capacitive currents asso-ciated with underground feedercable at the riser pole

• Silicone rubber insulator (110 -180 kV BIL) or polymer con-crete insulator (110 & 125 kVBIL)

• Cutout/arrester combination

• ECD

NCX

• Distribution cutout for overcur-rent protection on overhead dis-tribution systems

• 15 kV – 38 kV, up to 20 kA

• Provides visible indication offuse operation and a visiblebreak sectionalizing point formaintenance personnel

• Can function as a loadbreakswitch when used in conjunctionwith a portable loadbreak tool

• Polymer concrete insulator(110 & 125 kV BIL)

• Cutout/arrester combination

EU

• Enclosed cutouts in porcelain housing

• Designed for either dropout ornon-dropout operation

• For outdoor use only

• Used in replacement applica-tions in close spaces wherethere are increased safetyneeds

N/A

Overhead Disconnect Switches

Product Description Application Options

SID

• Single insulator disconnect witha double blade door and two 2-hole extended NEMA pad termi-nals

• 15 kV – 38 kV, 600 or 900 Acontinuous loads with a 40 kAmomentary rating

• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations.

• Can be mounted like a standardcutout: underhung, mounteddirectly on a pole for use as adisconnect between overheadand underground lines, or as avisible disconnect for mainte-nance of line equipment

• Polymer concrete insulator(110 & 125 kV BIL)

• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically

LSID

• Loadbreak single insulator dis-connect with self-containedloadbreak capabilities, a doubleblade door, and two 2-holeNEMA pad terminals

• 15.5 kV – 15/27 kV, 600 A con-tinuous and loadbreak

• Single-phase disconnect onoverhead distribution feedersand in outdoor distribution sub-stations

• Self-contained loadbreakenables lineman to interrupt loadcurrent with a hookstick

• Can be mounted underhung likea standard cutout or mounteddirectly on a pole used as a dis-connect between overhead andunderground lines

• Polymer concrete insulator(110 & 125 kV BIL)

• Optional mounting kit allowsthe following mounting scenar-ios: single or double crossarmunderhung, directly on a pole,directly on a pole vertically,and crossarm vertically

DCD

• Double insulator single-phasedisconnect switch

• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)

• Hookstick operated switch usedfor sectionalizing or isolatingequipment on electrical distribu-tion systems up to 38 kV

• Can be mounted vertical orunderhung, or on a single ordouble crossarm

• Insulators available in 2.25”bolt circle porcelain or epoxy

• Bypass studs available forbypassing reclosers, voltageregulators, capacitor banks, ormetering devices

RBD

• Single-phase bypass disconnectswitch

• Rated at 600 or 900 A, availablein nominal ratings of 14.4 kV(110 BIL) or 25 kV (125 BIL)

• Provides a means for bypassingand disconnecting reclosers orvoltage regulators, allowingmaintenance on equipment with-out service interruption

• Can be mounted in the followingconfigurations: vertical or under-hung, pole-mounted, or single ordouble crossarm

• Insulators available in 2.25”bolt circle porcelain or epoxy

• Mounting options: back bracketfor vertical or underhung, 30-degree pole-mount bracket, orpackage of three switches pre-mounted on crossarm

ITD

• Single-phase, non-loadbreak,inline tension disconnect switchwith silicone insulator

• Maximum voltage ratings: 15 kV(150 BIL) or 27 kV (150 BIL)

• Continuous current rating of 600or 900 A

• Used for manual switching ofde-energized or parallel circuitsof overhead distribution linesrated 15-38 kV

• Loadbreak hooks allow for oper-ation with a portable loadbustertool

N/A

greensboro overview.qxp 1/5/2005 11:16 AM Page 2

Page 3: ABB Outdoor 1 Overview

1VAG

0001

-DB

Rev

. A O

ctob

er 2

004

© C

opyr

ight

200

4 AB

B. A

ll rig

hts

rese

rved

.

ABB Inc.406 Banner AvenueGreensboro, NC 27401Tel: +1-252-827-3212www.abb.com/mediumvoltage

Capacitor Fuses

Indoor

CLN

• 600 V Current Limiting

• Continuous amperes: 25, 50, 75, 100, 125, 150, 175, 200, 225

• Primary application is individual unit fusing of low voltage single and three phase capacitors in metalenclosed equipment

CLC

• 1.2-4.3 kV Current Limiting

• The 1200, 1800 and 3000 volt ratings are current limiting, indicating and non disconnecting

• The 2500 volt and 4.3/2.5 kV ratings are current limiting, non-indicating and non-disconnecting

• Primary application is individual unit fusing of low voltage single and three phase capacitors in metalenclosed equipment

CIL

• 5.5-15.5 kV Current Limiting & Expulsion

• Two part design:- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current

from parallel capacitors- the low voltage sections consist of a standard NEMA type K fuse link mounted in a fiber tube

Outdoor

CXP

• 9.7-26.2 kV Expulsion

• Primary application is individual capacitor unit fusing in outdoor capacitor equipment

• Applications: in all ungrounded wye applications, in all grounded wye applications when the capacitorunits are connected in two or more series group

COL

• 2.8-23 kV Current Limiting & Expulsion

• Two part design:- the high current section interrupts high 60Hz fault currents and/or high frequency discharge current

from parallel capacitors- the low voltage sections consists of a standard NEMA type K fuse link mounted in a fiber tube

CLXP

• 2.5-25 kV Current Limiting & Expulsion

• A very high energy capability individual capacitor fuse used in outdoor banks with many parallelcapacitor units