a60 compliant

31
BUREAU VERITAS - Marine Division - The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 1/31 SHIPS IN SERVICE SURVEY REPORT DRB0/2012/J0251 08112U AFRICAN JAGUAR 9082623 Register Number Ship Name IMO Number Connecting District BV PIRAEUS (LPR0) Marine Center BV PIRAEUS (CMG1M) Flag Ship Manager Ship Owner BAHAMAS ENTERPRISES SHIPPING & TRADING S.A. MABEL MARITIME CORP. DATES OF SURVEY PLACE OF SURVEY Start End 20/10/2012 27/11/2012 DURBAN : Durban SOUTH AFRICA SURVEYORS Mzo Malimba, Jeremy Brown, Wanda Mtshali SSOM Jeremy Brown Report validated Stamp on by 11/12/2012 Jeremy Brown

Upload: efthymios-louridas

Post on 20-Jul-2016

51 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A60 Compliant

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 1/31

SHIPS IN SERVICE SURVEY REPORT

DRB0/2012/J0251

08112U AFRICAN JAGUAR 9082623 Register Number Ship Name IMO Number

Connecting District BV PIRAEUS (LPR0)

Marine Center BV PIRAEUS (CMG1M)

Flag

Ship Manager

Ship Owner

BAHAMAS

ENTERPRISES SHIPPING & TRADING S.A.

MABEL MARITIME CORP.

DATES OF SURVEY PLACE OF SURVEY Start

End

20/10/2012

27/11/2012

DURBAN : Durban SOUTH AFRICA

SURVEYORS

Mzo Malimba, Jeremy Brown, Wanda Mtshali

SSOM Jeremy Brown

Report validated Stamp on

by

11/12/2012

Jeremy Brown

Page 2: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 2/31

SURVEY STATEMENT

SHIP DOCUMENTS

Certificates / Statements of Compliance Endorsed New document issued Expiry Date Document

extended until Classification Certificate Yes Definitive 08/02/2016 LL Load Line Yes Definitive 08/02/2016 SOLAS Safety Construction Harmonized Yes Definitive 08/02/2016 SOLAS Safety Equipment Harmonized Yes Conditional 27/01/2013 SOLAS Safety Radio Harmonized Yes Definitive 08/02/2016 SOLAS Dangerous goods Yes Definitive 08/02/2016 MARPOL Annex I IOPP Yes Definitive 08/02/2016 MARPOL Annex VI Prevention Air Pollution Certific. Yes Definitive 08/02/2016 IAFS International Anti-Fouling System Certificate Yes Definitive

SURVEY(S) CARRIED OUT

Code Survey Name AFSS Anti-Fouling System Renewal Survey AOF1 Auxiliary Oil-Fired Boiler No 1 Internal and External Survey ASB Boiler Annual Survey ASH Hull Annual Survey ASHS Annual survey of structure (Complete) ASM Machinery Annual Survey DGAS Dangerous Goods Annual Survey DOK Periodical Bottom Survey in Dry Dock HSCI Harmonized Safety Construction Intermediate Survey HSCO Harmonized Safety Construction Occasional Survey HSEO Harmonized Safety Equipment Occasional Survey HSEP Harmonized Safety Equipment Periodical Survey HSRP Harmonized Safety Radio Periodical Survey IAPI IAPP Intermediate Survey INT Hull Intermediate Survey (Complete) LLPI Load Line Annual Survey OSH Hull Occasional Survey POIS IOPP Intermediate Survey TCEC Centre Tailshaft Complete Survey

NEW PLANNED INSPECTION ITEMS

Number Description Limit Date Type Verif.Sch.1 Extends / Upgrades

Statutory - SOLAS Safety Equipment Harmonized

DRB0/2012/J0251-SE1R permanent repairs or replacement on the stbd side lifeboat to be carried out. 27/01/2013 Rec 2 extends

DRB0/2012/J0237-SE1R

1Verification scheme :

1. Inspection/test/report by authorized person and confirmation of action taken through http://www.veristar.com by the indicated limit date. Documentary evidence to be kept on board. Verification/confirmation by BV Surveyor during next attendance onboard.

2. Survey by BV Surveyor by limit date.

Page 3: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 3/31

PLANNED INSPECTION ITEMS DEALTWITH OR POSTPONED

Number Description Status

Statutory - SOLAS Safety Equipment Harmonized

DRB0/2012/J0237-SE1R permanent repairs or replacement on the stbd side lifeboat to be carried out. extended by DRB0/2012/J0251-SE1R

Statutory - SOLAS Safety Construction Harmonized

DRB0/2012/J0237-SC1R Vessel to sail in ballast from Richards Bay to Durban for repairs to shell plating, propeller blades, port side windlass, anchor and chain(loss). dealt with

Class - Hull

DRB0/2012/J0237-H1R Vessel to sail in ballast from Richards Bay to Durban for repairs to shell plating, propeller blades, port side windlass, anchor and chain(loss). dealt with

Page 4: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 4/31

SURVEY REPORT

Survey(s) has(ve) been carried out in accordance with the applicable BV Rules and Regulations and International Conventions, and within the scope of the Bureau Veritas Marine Branch General Conditions. The survey items were found

to the Surveyor's satisfaction, subject to the following remarks

Table of contents Page

1. Surveyor's statement................................................................................................................................................ 5 2. Documentation.......................................................................................................................................................... 5 3. Hull ............................................................................................................................................................................ 6 4. Bottom survey........................................................................................................................................................... 7 5. Propeller shaft survey .............................................................................................................................................. 7 6. Structure ................................................................................................................................................................... 8 7. Fire protection and fire fighting............................................................................................................................ 11 8. Boiler survey ........................................................................................................................................................... 12 9. Safety - Miscellaneous............................................................................................................................................ 12 10. Life-saving appliances............................................................................................................................................ 13 11. Radiocommunications............................................................................................................................................ 13 12. Anti-Fouling............................................................................................................................................................ 13 13. Annex for Tank Testing......................................................................................................................................... 14 14. Annex for Overall/Internal Tank Survey............................................................................................................. 15 15. Annex for Boiler internal / external examination................................................................................................ 23 16. Annex for Documentation on board ..................................................................................................................... 23 17. Annex for Safety and Fire Fighting Equipment .................................................................................................. 23 18. Other Annex(es) ..................................................................................................................................................... 26 18. Other Annex(es) ..................................................................................................................................................... 26

Page 5: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 5/31

1. Surveyor's statement

DCC001 LLPI-ASHS-DGAS-ASM-ASH-HSCI-HSRP-DOK-TCEC-HSEP-AOF1-POIS-INT-AFSS-ASB-IAPI

Confirmation that applicable items of Rules and Regulations and International Conventions relevant to the present survey scope have been surveyed to the surveyor's satisfaction without remark, except when indicated otherwise hereunder

DCC005A ASM-ASH-HSCI-HSRP-DOK-TCEC-HSEP-AOF1-POIS-INT-AFSS-ASB-IAPI-LLPI-ASHS

Confirmation that the Master has been asked if he had anything to declare or put to his attention and that no additional points have been raised by the Master with respect to the ship's classification and statutory certification.

2. Documentation

Documents

DCA010 AFSS-HSEO-OSH-DGAS-TCEC-POIS-DOK-HSRP-ASB-LLPI-ASM-ASH-HSCI-HSCO-HSEP-AOF1-INT-IAPI

Done in current job See Remark

Verification of records of previous PSC inspections which have raised PSC deficiencies in relation with class or statutory certificate issued by BV (ship detained or not). Confirmation, through records or survey, that these deficiencies have been effectively corrected. Remark no outstanding PSC deficiencies as per last report.

DXX010A ASB-ASH-ASM-AOF1-INT-DOK-TCEC Done in current job See RemarkVerification of inspection, measuring and test equipment: confirmation that calibration and appropriate accuracy of such equipment has been carried out. If evidence of such calibration and accuracy is not available to the Society's Surveyor, then duplication of inspections, measurements or tests using two different equipment is considered as a satisfactory means. Remark Either by duplication or calibration certificate.

Certificates

DCS011A LLPI-HSCI-HSEP-IAPI-HSRP-POIS See RemarkSOLAS : Confirmation that the Cargo Ship Safety Construction Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS012A IAPI-HSRP-POIS-LLPI-HSCI-HSEP See RemarkSOLAS : Confirmation that the Cargo Ship Safety Equipment Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS013A HSCI-HSEP-IAPI-HSRP-POIS-LLPI See RemarkSOLAS : Confirmation that the Cargo Ship Safety Radio Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS015 DGAS See RemarkSOLAS : Confirmation that the Document of Compliance for the carriage of dangerous goods is available on board Remark new definitive certificate issued expiring 08/02/2016.

DCS020A POIS-LLPI-HSCI-HSEP-IAPI-HSRP See RemarkFREEBOARD : Confirmation that the International Loadline Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

Page 6: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 6/31

DCS025A HSCI-HSEP-AFSS-IAPI-HSRP-POIS-LLPI See RemarkAFS : Confirmation that the International Anti-Fouling Certificate is available on board Remark new certificate issued.

DCS031A HSCI-HSEP-IAPI-HSRP-POIS-LLPI See RemarkMARPOL : Confirmation that the International Oil Pollution Prevention Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS033A HSCI-HSEP-IAPI-HSRP-POIS-LLPI See RemarkMARPOL : Confirmation that the Noxious Liquid Substances Certificate is available on board and due surveys are up to date Remark N/A

DCS035A HSRP-POIS-LLPI-HSCI-HSEP-IAPI See RemarkMARPOL : Confirmation that the International Air Pollution Prevention Certificate (IAPP) is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS036A HSRP-POIS-LLPI-HSCI-HSEP-IAPI See RemarkMARPOL : Confirmation that the International Sewage Pollution Prevention Certificate is available on board and due surveys are up to date Remark new definitive certificate issued expiring 08/02/2016.

DCS040A DOK-TCEC-POIS-HSRP-ASB-LLPI-ASM-ASH-HSEP-HSCI-INT-IAPI

Done in current job See Remark

CLASSIFICATION : Confirmation that the Classification Certificate and relevant Annexes are available on board and due surveys are up to date (before starting of survey) Remark new definitive certificate issued expiring 08/02/2016.

3. Hull

Hull and hull equipment

CAC140B ASH-HSCI Verification of proper operation of the loading instrument, if any, with standard test. Test results : Satisfactory Not satisfactory - See Remarks

EMB001A HSEP Verification of means of embarkation and disembarkation from ships for use in port and in port-related operations, such as gangways and accommodation ladders, are in satisfactory condition Date of the last 5-yearly test 26/05/2011

EMB002A HSEP Was a test of means of embarkation and disembarkation from ships for use in port and in port-related operations, such as gangways and accommodation ladders, including associate winch and fittings performed during this survey? Yes No

EMB003A HSEP See RemarkOperational test of accommodation ladders including associated winch and fittings and/or gangways

Equipment description Test load (t) Test satisfatory (Y/N)

Remark functional test carried out.

Page 7: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 7/31

4. Bottom survey

Bottom (periodical survey)

DOK040 DOK-HSCI See RemarkPropeller-shaft clearances :

Clearance position mm

Remark see attached clearances report.

DOK060 DOK-HSCI See RemarkExamination of rudder; clearances measured :

Clearance position: mm

Remark see attached clearances report.

Bottom (every 5 years)

DOK503 DOK See RemarkRecording of permanent chain characteristics :

Register of ships diameter 60 Minimum allowed diameter 52.8 Grade of cable Q3

Remark see attached chain calibration report and new chain certificate.

DOK505 DOK See RemarkLinks measurement : fill out the table hereunder or use its fourth column to specify the references of the complete result document attached to the present report :

Position Diam.PS (mm) Diam.SB (mm) Comment (if any)

Remark new port side chain and anchor fitted, see attached certificate.

DOK506 DOK See RemarkInternal examination of chain locker(s) and its pumping arrangement. Remark definitive repairs carried out on the steel plating on the lower part of the port and stbd chain locker.

Bottom (others)

OTH050 DOK Thickness measurements of plating below the waterline. Ref. to TM report (Page Nbr)

5. Propeller shaft survey

Centre propeller shaft

CCO020A TCEC See RemarkExamination of cone/ key/keyway or fillet of the flange. Non-destructive test of cone/ key/keyway. Non-destructive test of aft flange fillet area for solid flange coupling if visual examination non satisfactory. Remark see attached NDT report.

Page 8: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 8/31

CPA080 TCEC See RemarkVerification of the propeller-shaft clearances :

Reading position mm

Remark see attached propeller clearances.

6. Structure

Hull occasional survey

OSH000 OSH See RemarkScope and description of the Hull occasional survey: Description and remark

OSH carried out for the for definitive repairs on the stbd side shell plating iwo BWT no.5 & 4, chain locker, boat deck & TST. Crop and renewed 24 tons of steel iwo DB BWT no.5, crop and renwed 2 plates(approx 2000mm X 2000mm) plate renewed iwo DB WBT no.4 and about 10000mm of bilge keel replaced, crop and renewed bottom half of the port and stbd chain lockers, steel frames renewed iwo of Cargo hold no 3 and 4 for'd and aft underneath the deck, replaced port and stbd TST no. 1 ladder All, TST no.2 ladder, TST no.3 stbd 900mm piece on the ladder and TST no.3 port frame. repairs carried out successfully and MPI, NDT, vacuum and pressure tests carried successfully. recommendation DRB0/2012/J0237 - H1R now dealt with.

Bulk Carriers and other ship types retroactive measures

BCG611 INT Done in current job See RemarkRe-evaluation of thickness measurements of transverse bulkhead between cargo holds n°1 and 2 when retroactive measures are applied. Thickness measurements to be performed on each corrugation of the bulkhead. The following table is to filled out, or alternatively report of measurement to be attached. Columns headings are corresponding to: Corr. n°: reference number of the corrugation measured Low CF: low level corrugation flange Low CW: low level corrugation web Low GP: low level gusset plate Low SP: low level shedder plate Mid CF: mid level corrugation flange Mid CW: mid level corrugation web Remark hold does not have corrugated bulkhead.

BCG621 INT Done in current job Further to thickness measurements of the corrugated bulkhead (see item BCG611), are repairs or reinforcements needed ? Yes No

BCG865 INT Done in current job Steel renewal criteria for side shell frames and brackets.Re-evaluation at subsequent intermediate and class renewal surveys, after the initial evaluation:references of thickness measurements carried out on the side shell frames and brackets. name of TM firm, date and place where measurements were carried out, references of report ref to Section 3 of the UTM report page 37 to 81.

Page 9: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 9/31

BCG870 INT Done in current job See RemarkSteel renewal criteria for side shell frames and brackets.Re-evaluation at subsequent intermediate and class renewal surveys, after the initial evaluation:results of thickness measurements. The following table is to be filled out or, alternatively, the report of measurement is to be attached. The columns headings are corresponding to: Hold: indicate the hold number (foremost hold is hold No1) Frame: indicate the frame number P/S : indicate position of the frame within the hold (port or starboard) A : indicate the average reading of the web of zone A of the frame (and, in case the calculation of section modulus is required, indicate the average reading on the flange/face plate and on the attached shell plating on each side of the frame) B : indicate the average reading of the web of zone B of the frame (and, in case the calculation of section modulus is required, indicate the average reading on the flange/face plate and on the attached shell plating on each side of the frame) C : indicate the average reading of the web of zone C of the frame D : indicate the average reading of the web of zone D of the frame

Hold Frame P/S A B C D

Remark ref to Section 3 of the UTM report page 37 to 81.

BCG875 INT Done in current job Steel renewal criteria for side shell frames and brackets.Re-evaluation at subsequent intermediate and class renewal surveys, after the initial evaluation:are steel renewals or reinforcements needed further to results of thickness measurements carried out ? (if yes, refer to BCG880) Yes No

BCG880 INT Done in current job See RemarkSteel renewal criteria for side shell frames and brackets.Re-evaluation at subsequent intermediate and class renewal surveys, after the initial evaluation:details of renewals or reinforcements carried out on the side shell frames and brackets. Indicate the hold No, the frame No and its position (Port or Starboard within the hold), the zone where the renewal or reinforcement has been carried out (A, B, C, D) and the type of repair (steel renewal; other measures i.e sand blasting and coating and fitting tripping brackets and maintaining the coating in "as-new condition"; reinforcement of flange; tripping brackets; stiffener on lower bracket). Description and remark hold no. 5 stbd side zone C, B and A - steel renewal and coated.

BCG980 INT-ASH-HSCI Done in current job See RemarkSOLAS Reg.XII/14 (Restriction from sailing with any hold empty): Confirmation that the loading booklet has been endorsed, that the ship's sides have been permanently marked with a triangle, and that the additional service features "nonhomload" and "holds (a, b, c...) may be empty" have been deleted from the Certificate of Classification, for cargo density of 1.78 kg/m3 and above. Remark loading booklet is not endorsed.

Overall surveys

VGV040A INT Done in current job Overall survey of all cargo holds. See Annex

VGV060 INT Done in current job Overall survey of all ballast tanks (inside and outside cargo area). See Annex

VGV065 INT Done in current job Overall survey of all other spaces than fuel oil, fresh water or lubricating oil tanks, within the cargo length area. See Annex

VGV220 ASHS Done in current job For single skin bulk carriers, overall survey of all cargo holds. See Annex

Page 10: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 10/31

VGX010 INT-ASH Done in current job Additional tank overall surveys, as deemed necessary by Survey Centre surveyor. See Annex

Tank testing

EPX010 INT Done in current job Additional test of tanks, as deemed necessary by Survey Centre surveyor. See Annex

Systematic and other thickness measurements

CAX020A INT Done in current job See RemarkDate and place of survey meeting, name of the master of the ship in attendance or an appropriately qualified representative appointed by the master or Company, name of the owner's representative(s) and name(s) of the thickness measurement firm's representative(s) so as to ensure the safe and efficient execution of the surveys and thickness measurements to be carried out onboard.

Date of survey meeting Place of survey meeting Master of the ship or appropriatly qualified representative Owner's representative(s) Thickness measurements firm representative(s)

Remark see attached minutes report.

MEV035 INT Done in current job Thickness measurements of all deck plates within the cargo area, outside the line of cargo-hatch openings. Ref. to TM report (Page Nbr) page 3 - 10

MEV055 INT Done in current job Thickness measurements of two (2) transverse sections, within the cargo area, with one in the midship area, outside the line of cargo-hatch openings.

Section Frame Number Reference to TM report (page number) Coef. Done

1 59-60 page 83 0.0 X 2 109-110 page 84 0.0 X 3 139-140 page 85 0.0 X

MEV105 INT Done in current job Thickness measurements of all wind-and-water strakes within the cargo area. Ref. to TM report (Page Nbr) page 11-36

MEV116A INT Done in current job Thickness measurements of selected wind-and-water strakes outside the cargo area. Ref. to TM report (Page Nbr) page 11-36

MEX030A INT-ASH-DOK Done in current job Additional thickness measurements as deemed necessary. Yes No

Close-up surveys and/or associated thickness measurements

VRV200 ASHS Done in current job See RemarkClose-up survey of all cargo hold hatch cover plating and hatch coaming plating and stiffeners. Remark ref to UTM report section 12 and 13 page 439-452 hatch coamings and page 453-464 hatch covers.

VRV205 ASHS Done in current job See RemarkFor single skin bulk carriers, close-up survey of lower region of minimum 25% of shell frames, including shell frame end attachment and adjacent shell plating, in the forward cargo hold. Remark ref to UTM report section3 page 37-81.

Page 11: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 11/31

VRV207 ASHS Done in current job See RemarkExamination of all piping and penetrations, including overboard piping, in all cargo holds. Remark ref to UTM report section 17 page 492-495.

VRV210 ASHS Done in current job See RemarkFor single skin bulk carriers, close-up survey of lower region of 25% of shell frames, including shell frame end attachment and adjacent shell plating, in one (1) selected cargo hold, other than forward cargo hold. Remark ref to UTM report section3 page 37-81.

VRV215 ASHS Done in current job For single skin bulk carriers, if repairs are needed in one cargo hold, close-up survey of all shell frames and adjacent shell plating of that cargo hold, as well as close-up survey of sufficient extent of all remaining cargo holds. See Annex

VRV356 INT Done in current job See RemarkFor single skin bulk carriers, close-up survey and thickness measurements of all shell frames in the forward cargo hold and one other selected cargo hold, including upper and lower end attachements and adjacent shell plating. Remark ref to UTM report section3 page 37-81.

VRV361 INT Done in current job See RemarkFor single skin bulk carriers, close-up survey and thickness measurements of 50% of shell frames in all remaining cargo holds, including upper and lower end attachements and adjacent shell plating. Remark ref to UTM report section3 page 37-81.

VRV370A INT Done in current job See RemarkClose-up survey and thickness measurements of all transverse webs with associated plating and longitudinals in each water ballast tank Remark ref to UTM report section 7 page 138-295 and section 8 page 296-378.

VRV375A INT Done in current job See RemarkClose-up survey and thickness measurements of all transverse bulkheads in all ballast tanks. Remark ref to UTM report section 7 page 138-295 and section 8 page 296-378.

VRV381B INT Done in current job Close-up survey and thickness measurements of all cargo hold transverse bulkheads, including internal structure of upper and lower stools if fitted. See Annex

VRV385B INT Done in current job See RemarkClose-up survey and thickness measurements of all cargo hold hatch covers and coamings (platings and stiffeners). Remark ref to UTM report section 12 and 13 page 439-452 hatch coamings and page 453-464 hatch covers.

VRV390B INT Done in current job See RemarkClose-up survey and thickness measurements of all deck plating and underdeck structure inside line of hatch openings between cargo hold hatches. Remark ref to UTM report section 1 page 3-10.

VRX030 INT Done in current job Additional close-up surveys as deemed necessary by the Survey Centre surveyor.

VRX040 INT Done in current job Additional thickness measurements associated with close-up surveys, as deemed necessary by the Survey Centre surveyor.

7. Fire protection and fire fighting

Page 12: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 12/31

Basic fire fighting equipment

FFE165 HSEP-ASM Type of gas used in the fixed fire-fighting appliance in other spaces (like paint lockers, galleys, etc.) ? Halon CO2 Other

Special arrangements in machinery spaces

FFE090 ASM-HSEP Type of gas used in the fixed fire-fighting system for the machinery spaces ? Halon CO2 Other

Cargo spaces

FFE117 HSEP-ASM Type of gas used in the fixed fire-fighting system for the cargo spaces ? Halon CO2 Other

Carriage of dangerous goods

FFE170 DGAS Examination, as far as possible, and test, as feasible, of additional safety measures in cargo spaces intended for the carriage of dangerous goods. See Annex

8. Boiler survey

BOIL001 AOF1 Boiler(s) internal/external examination and tests See Annex

9. Safety - Miscellaneous

Shipborne navigational equipment

NAV080A HSEP Is the vessel provided with an ECDIS? Yes No

Occasional statutory surveys

OCS020 HSCO See RemarkScope and description of the Safety Construction occasional survey: Description and remark for definitive repairs carried out on the propeller blades, port side windlass, and replacement of the port side anchor and chain. All repairs carried out successfully, see attached repair report for further details. Rec DRB0/2012/J0237 - SC1R now dealt with.

OCS030 HSEO See RemarkScope and description of the Safety Equipment occasional survey: Description and remark

HSEO for the repairs or replacement of the stbd side lifeboat and Davit. The Davit was successfully repaired and test loaded, see attached loading report. The lifeboat could not be replaced due to delay in delivery, the damaged lifeboat was temporary replaced by 2 X 16 man liferaft(Flag agreement)fitted with HRUs, see attached e-mail. Rec DRB0/2012/J0237 - SE1R cancelled for postponement. new L.D 27/01/2013(stbd side lifeboat to be replaced).

Page 13: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 13/31

10. Life-saving appliances

Lifeboats

LSA220 HSEP Test of lowering of one lifeboat to the water, if practicable. Number and side of the lowered lifeboat(s): port side

Rescue boat

LSA1100A HSEP See RemarkExamination of each rescue boat, including its equipment. For inflatable rescue boats, confirmation that they are stowed in a fully inflated condition. Remark Stbd side lifeboat is also a rescue boat is out of service.

11. Radiocommunications

Reference of Radio Surveyor s report

STR009 HSRP See RemarkReference of Radio Surveyor's report : Description and remark carried out successfully, see attached report.

12. Anti-Fouling

AFS021 AFSS Type of anti-fouling system. TBT-Free self polishing

AFS022 AFSS Name of anti-fouling system manufacturer. Chugoku marine paints

AFS023 AFSS Name and color of anti-fouling system. Seagrandprix 660HS brown, Marine Star 30G red

AFS024 AFSS See RemarkActive ingredient(s) and their Chemical Abstract Service Registry Number (CAS number (s)). Description and remark Cuprous(l)Oxide / CAS 1317-39-1 4,5-Dichlor-2-N-Octyl-4-Isothiazole-3-One / CAS 64359-81-5

AFS030 AFSS Date of beginning and Date of end of application of the anti-fouling system.

Date Beginning 12/11/2012 Ending 13/11/2012

Page 14: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 14/31

13. Annex for Tank Testing

Identification Use1 Frames Conditions of test:

Head of liquid to Result Remark Done2 Coef. Item

Forepeak Tank BT 201 - 220 Top of air pipes Satisfactory X 0.0 EPX010

No.5 WBT Stbd BT 34 - 68 Top of air pipes Satisfactory X 0.0 EPX010

(1) Use (2) Done BT : Ballast Tank X

: in current job

Page 15: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

(1) Use (2) Done (3) Results (4) Findings

CH BT FW

: Cargo Hold : Ballast Tank : Fresh Water Tank

X

: in current job

COCR BU IN

: Corrosion : Crack : Buckling : Indent

Rep.PII SA

: Repairs carried out : Planned Inspection Item

R : Recommendation O : Observation

: Suspect Areas (presenting substantial corrosion)

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 15/31

14. Annex for Overall/Internal Tank Survey

Frame Results3 Findings4 Identification Use1

I F Done2 Protection Extent Coating

ConditionClose

up CO CR BU IN Piping/Fittings Add.

Close up Rep. PII SA Item

No.1 Cargo Hold CH 173 201 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV040A, VGV220, VRV381B

No.2 Cargo Hold CH 138 173 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV040A, VGV220, VRV381B

No.3 Cargo Hold CH 103 138 X Hard coated Complete Good Y N N N N Satisfactory N Y N VGV040A, VGV220, VRV215, VRV381B

No.4 Cargo Hold CH 68 103 X Hard coated Complete Good Y N N N N Satisfactory N Y N VGV040A, VGV220, VRV215, VRV381B

No.5 Cargo Hold CH 34 68 X Hard coated Complete Good Y N N N N Satisfactory N Y N VGV040A, VGV220, VRV215, VRV381B

Forepeak Tank BT 201 220 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060

No.1 TST Port BT 173 201 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.1 TST Stbd BT 173 201 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.1 WBT Port BT 173 201 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.1 WBT Stbd BT 173 201 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.2 TST Port BT 138 173 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060,

Page 16: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

(1) Use (2) Done (3) Results (4) Findings

CH BT FW

: Cargo Hold : Ballast Tank : Fresh Water Tank

X

: in current job

COCR BU IN

: Corrosion : Crack : Buckling : Indent

Rep.PII SA

: Repairs carried out : Planned Inspection Item

R : Recommendation O : Observation

: Suspect Areas (presenting substantial corrosion)

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 16/31

Frame Results3 Findings4 Identification Use1

I F Done2 Protection Extent Coating

ConditionClose

up CO CR BU IN Piping/Fittings Add.

Close up Rep. PII SA Item

VGX010

No.2 TST Stbd BT 138 173 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.2 WBT Port BT 138 173 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.2 WBT Stbd BT 138 173 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.3 TST Port BT 103 138 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.3 TST Stbd BT 103 138 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.3 WBT Port BT 103 138 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.3 WBT Stbd BT 103 138 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.4 TST Port BT 68 103 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.4 TST Stbd BT 68 103 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.4 WBT Port BT 68 103 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.4 WBT Stbd BT 68 103 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.5 TST Port BT 34 68 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.5 TST Stbd BT 34 68 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.5 WBT Port BT 34 68 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060, VGX010

No.5 WBT Stbd BT 34 68 X Hard coated Complete Good Y N N N N Satisfactory N Y N VGV060,

Page 17: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

(1) Use (2) Done (3) Results (4) Findings

CH BT FW

: Cargo Hold : Ballast Tank : Fresh Water Tank

X

: in current job

COCR BU IN

: Corrosion : Crack : Buckling : Indent

Rep.PII SA

: Repairs carried out : Planned Inspection Item

R : Recommendation O : Observation

: Suspect Areas (presenting substantial corrosion)

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 17/31

Frame Results3 Findings4 Identification Use1

I F Done2 Protection Extent Coating

ConditionClose

up CO CR BU IN Piping/Fittings Add.

Close up Rep. PII SA Item

VGX010 Aft Peak Tank BT -4 9 X Hard coated Complete Good Y N N N N Satisfactory N N N VGV060

Page 18: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 18/31

Tank characteristics : Aft Peak Tank Init. Frame : -4 Final Frame : 9 Use :Ballast Tank Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame 5 for'd - transverse floor Corresponding thickness measurements (reference of report, page, N°) : page 136

Other Comments/Conclusion :

none.

Tank characteristics : Forepeak Tank Init. Frame : 201 Final Frame : 220 Use :Ballast Tank Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame 201 transverse bulkhead plating. Corresponding thickness measurements (reference of report, page, N°) : page 382

Other Comments/Conclusion :

tank in satisfactory condition.

Tank characteristics : No.1 Cargo Hold Init. Frame : 173 Final Frame : 201 Use :Cargo Hold Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : all port and stbd side frames. Corresponding thickness measurements (reference of report, page, N°) : all port and stbd side frames, ref UTM report section 3 page 38-45.

Other Comments/Conclusion :

hold in satisfactory condition.

Tank characteristics : No.1 TST Port Init. Frame : 173 Final Frame : 201 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 175 and 193 main deck long web. Corresponding thickness measurements (reference of report, page, N°) : page 303 and 311

Other Comments/Conclusion :

none.

Tank characteristics : No.1 TST Stbd Init. Frame : 173 Final Frame : 201 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 175 and 193 main deck long web. Corresponding thickness measurements (reference of report, page, N°) : page 303 and 311

Other Comments/Conclusion :

none.

Tank characteristics : No.1 WBT Port Init. Frame : 173 Final Frame : 201 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 181 and 185 - inner bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 152 and 156

Other Comments/Conclusion :

none.

Page 19: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 19/31

Tank characteristics : No.1 WBT Stbd Init. Frame : 173 Final Frame : 201 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 177 and 195 - inner bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 148 and 161

Other Comments/Conclusion :

none.

Tank characteristics : No.2 Cargo Hold Init. Frame : 138 Final Frame : 173 Use :Cargo Hold Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : all port and stbd side frames. Corresponding thickness measurements (reference of report, page, N°) : all port and stbd side frames, ref UTM report section 3 page 46-54.

Other Comments/Conclusion :

hold in satisfactory condition.

Tank characteristics : No.2 TST Port Init. Frame : 138 Final Frame : 173 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 173 Corresponding thickness measurements (reference of report, page, N°) : page 374

Other Comments/Conclusion :

none.

Tank characteristics : No.2 TST Stbd Init. Frame : 138 Final Frame : 173 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 173 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 374

Other Comments/Conclusion :

none.

Tank characteristics : No.2 WBT Port Init. Frame : 138 Final Frame : 173 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 141 and 157 - inner bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 169 and 181

Other Comments/Conclusion :

none.

Tank characteristics : No.2 WBT Stbd Init. Frame : 138 Final Frame : 173 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 144 and 160 - hopper long web and bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 171 and 183

Other Comments/Conclusion :

none.

Page 20: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 20/31

Tank characteristics : No.3 Cargo Hold Init. Frame : 103 Final Frame : 138 Use :Cargo Hold Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : all port and stbd side frames. Corresponding thickness measurements (reference of report, page, N°) : all port and stbd side frames, ref UTM report section 3 page 55-63.

Findings

Repairs Carried Out During Survey (Detail parts replaced-add sketches as deemed necessary) steel frames renewed underneath the deck aft & ford. Other Comments/Conclusion : hold in satisfactory condition.

Tank characteristics : No.3 TST Port Init. Frame : 103 Final Frame : 138 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 138 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 375

Other Comments/Conclusion :

none.

Tank characteristics : No.3 TST Stbd Init. Frame : 103 Final Frame : 138 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 138 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 375

Other Comments/Conclusion :

none.

Tank characteristics : No.3 WBT Port Init. Frame : 103 Final Frame : 138 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 107 and 125 - inner bottom long web and bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 200 and 212

Other Comments/Conclusion :

none.

Tank characteristics : No.3 WBT Stbd Init. Frame : 103 Final Frame : 138 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 113 and 131 - inner bottom long web and bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 204 and 216

Other Comments/Conclusion :

none.

Page 21: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 21/31

Tank characteristics : No.4 Cargo Hold Init. Frame : 68 Final Frame : 103 Use :Cargo Hold Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : all port and stbd side frames. Corresponding thickness measurements (reference of report, page, N°) : all port and stbd side frames, ref UTM report section 3 page 64-72.

Findings

Repairs Carried Out During Survey (Detail parts replaced-add sketches as deemed necessary) steel frames renewed underneath the deck aft & ford. Other Comments/Conclusion : hold in satisfactory condition.

Tank characteristics : No.4 TST Port Init. Frame : 68 Final Frame : 103 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 103 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 376

Other Comments/Conclusion :

none.

Tank characteristics : No.4 TST Stbd Init. Frame : 68 Final Frame : 103 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 103 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 376

Other Comments/Conclusion :

none.

Tank characteristics : No.4 WBT Port Init. Frame : 68 Final Frame : 103 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 72 and 90 - hopper long web and bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 233 and 245

Other Comments/Conclusion :

none.

Tank characteristics : No.4 WBT Stbd Init. Frame : 68 Final Frame : 103 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 81 and 96 - hopper long web and bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 239 and 240

Other Comments/Conclusion :

none.

Page 22: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 22/31

Tank characteristics : No.5 Cargo Hold Init. Frame : 34 Final Frame : 68 Use :Cargo Hold Position : Centre Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : all port and stbd side frames. Corresponding thickness measurements (reference of report, page, N°) : all port and stbd side frames, ref UTM report section 3 page 73-81.

Findings

Repairs Carried Out During Survey (Detail parts replaced-add sketches as deemed necessary) stbd side Sloping Wing tank iwo fr62-55 , and 8 side frames bottom plating renewed. Other Comments/Conclusion : hold in satisfactory condition.

Tank characteristics : No.5 TST Port Init. Frame : 34 Final Frame : 68 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 49 and 68 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 377 and 378

Other Comments/Conclusion :

none.

Tank characteristics : No.5 TST Stbd Init. Frame : 34 Final Frame : 68 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 49 and 68 - transverse BHD Corresponding thickness measurements (reference of report, page, N°) : page 377 and 378

Other Comments/Conclusion :

none.

Tank characteristics : No.5 WBT Port Init. Frame : 34 Final Frame : 68 Use :Ballast Tank Position : Portside Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 40 and 55 - hopper long web and inner bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 274 and 284

Other Comments/Conclusion :

none.

Tank characteristics : No.5 WBT Stbd Init. Frame : 34 Final Frame : 68 Use :Ballast Tank Position : Starboard Close Up Survey

EXTENT (locate frame n°. type of structure examined as per Rules) : frame no. 46 and 52 - hopper long web and inner bottom long web. Corresponding thickness measurements (reference of report, page, N°) : page 278 and 262

Findings

Repairs Carried Out During Survey (Detail parts replaced-add sketches as deemed necessary) definitive repairs iwo frame 62 - 57 (insert shell plating, 8 frames (zone C B &A) and internal webs, girders, frames). Other Comments/Conclusion : None.

Page 23: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 23/31

15. Annex for Boiler internal / external examination

AOF1

BLR040 Verification of remote control of safety devices (valves, mountings).

Remark : safety valves pressure tested successfully. see attached safety test report.

BLR050 Internal examination of the boiler, including :\n - combustion chambers (oil fired boilers)\n - furnaces\n - refractories\n - tubes\n - casing\n - bottom and front walls

Remark : internal part of the boiler in satisfactory condition.

BLR170 Verification of the analysis of thermal fluid.

Remark : n/a

16. Annex for Documentation on board

Reference Documents

NAV110 HSEP Confirmation that the Automatic Identification System has been subject to an annual testing and that a AIS Test Report issued by the testing facility is kept on board the ship

Test report issued by: SMD Telecommunications Date of issuance: 22/11/2012

NAV131 HSEP Confirmation that the voyage data recorder (VDR) or Simplified Voyage Data Recorder (S-VDR) has been subjected to an annual performance test and that a certificate of compliance issued by the testing facility is kept on board the ship.

Certificate issued by: SMD Telecommunications Date of issuance: 14/11/2012

NAV145 HSEP Confirmation that a valid conformance test report for the LRIT is available on board.

ASP name Transas Limited Date of issuance 19/11/2008

17. Annex for Safety and Fire Fighting Equipment

Fire protection and fire fighting

Fighter's outfits

FFE032A ASM-HSEP Date of recharge of the air cylinders : Date : 30/05/2012

Fire extinguishers

Page 24: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 24/31

FFE022A HSEP-ASM Date of recharge or date of inspection of the portable fire extinguishers : Date : 17 Aug 2012

FFE023A HSEP-ASM Date of recharge or date of inspection of the non-portable fire extinguishers : Date : 17 Aug 2012

Special arrangements in machinery spaces

FFE073A HSEP-ASM See RemarkDate when the CO2 cylinders were weighed or date when their level was checked : Weighed Checked Remark 17 Aug 2012

FFE075A HSEP-ASM See RemarkDate when any foam compounds were either analysed or renewed : Analysed Renewed Remark inspected 17 Aug 2012.

Cargo spaces

FFE114A HSEP-ASM Date when the CO2 cylinders were weighed or date when their level was checked : Date : 30/05/2012

Life-saving appliances

DCE082B HSEP See RemarkVerification through documentary evidence that survival crafts and rescue boat launching appliances were subjected to a periodical thorough examination and a dynamic test of the winch brake at the maximum lowering speed by a competent person. (record dates of last annual and 5-yearly examination and test)

Surv. craft type & identification Annual 5-yearly Lifeboat port side 22/11/2011 26/05/2011 Lifeboat stbd side 26/05/2011

Remark stbd side lifeboat to be replaced.

DCE084B HSEP Verification through documentary evidence that the survival craft and rescue boat on-load release systems were subjected to a thorough examination and operational test by a competent person. (record dates of last annual and 5-yearly examination and test)

Surv. craft type and identification Annual 5-yearly Lifeboat port side 22/11/2011 26/05/2011 Lifeboat stbd side 26/05/2011

Communications

LSA072B HSEP Date of validity of the rockets of the line-throwing appliance : Mar 2015

LSA074B HSEP Date of validity of the parachute distress signals : Mar 2015

Lifeboats

Page 25: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 25/31

LSA140B HSEP Checking that the hand flares are not out of date Validity date: Sep 2013

LSA160B HSEP Checking that the rockets parachute flares are not out of date Validity date: Jun 2014

LSA180B HSEP Confirmation that the buoyant smokes signals provided in lifeboats are not out of date Validity date: Sep 2013

Liferafts (inflatable)

LSA021A HSEP Date when each inflatable liferaft was serviced by an approved servicing station :

Liferaft nbr Date Serviced by 10232335 17/08/2012 Viking 06200015 17/08/2012 Viking 10949487 26/10/2012 Viking 11083937 17/08/2012 Viking 11549781 11/2012 Viking 11495384 11/2013 Viking

Personal

LSA046B HSEP Confirmation that the smoke signals provided for personnal life saving appliances are not out of date Validity date: Sep 2013

18.

Page 26: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 26/31

Other Annex(es) Annex FOR ITEM FFE170

Carriage of dangerous goods (SOLAS 74 - Regulation II-2/54) and BC Code Part Tank/Hold Use Position 1 No.1 Cargo Hold Cargo Hold Centre 2 No.2 Cargo Hold Cargo Hold Centre 3 No.3 Cargo Hold Cargo Hold Centre 4 No.4 Cargo Hold Cargo Hold Centre 5 No.5 Cargo Hold Cargo Hold Centre

Tank characteristics : No.1 Cargo Hold Init. Frame : 173 Final Frame : 201 Use :Cargo Hold Position : Centre

Reg. Yes No Na Space boundaries

II-2/54 8.1 A60 insulation for bulkheads separating the cargo space from a machinery space of category A X

II-2/54 8.2 A60 insulation for decks separating the cargo space from a machinery space of category A X

IMSBC 9.3 Space boundaries

IMSBC 9.3.2 Heated fuel tanks are arranged adjacent to the cargo space X

IMSBC 9.3.1 Boundaries of cargo space are resistant to fire and liquids. X

Fire Main

II-2/54 1.1 Permanent pressurisation of the fire main X

II-2/54 1.1bis Remote starting arrangement of fire pumps X

II-2/54 1.2 Fire main capable of suppying four nozzles X

Hydrants arranged so that four nozzles can be trained on any part of the cargo space X

II-2/54 1.3 Water spray system fitted with an application rate of at least 5L/m²/mn X

Electrical equipment

II-2/54 2 No electrical equipment except certified safe type (IIB, T4) X

Cable penetration sealed X

Cables protected against damage from impact X

IMSBC 9.3.2 Any electrical circuits terminating in the cargo space can be electrically disconnected from the power source at a point external to the space.

X

Fire protection, detection and alarm

II-2/54 3 Approved fire detection and fire alarm system X

II-2/54 7 Portable fire extinguishers with a total capacity of at least 12kg of dry powder are provided X

II-2/54 10 Cargo space fitted with a CO2 fixed fire fighting system X

IMSBC 3.4 Facilities for introducing carbon dioxide or another inert gas into the cargo space. X

Ventilation

II-2/54 4 Mechanical ventilation with a flow rate of more than 6 renewals per hour X

Fans are to be anti-sparking X

Openings are to be fitted with mesh guards (=< 13mm) X

Electrical motors, if fitted in the ducts, are to be of a safe type X

IMSBC 3.5 The cargo spaces are ventilated by at least two separate fans. X

Bilge arrangement

II-2/54 5.1 Means are provided to avoid inadvertent pumping in engine room (e.g. blanks on bilge lines at the ER bulkhead

X

II-2/54 5.2 Additional draining means are provided X

Page 27: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 27/31

Personnel protection

II-2/54 6.1 Four sets of full protective clothing resistant to chemical attack provided in addition to fireman outfits

X

II-2/54 6.2 Two self contained breathing apparatuses in addition to fireman outfits X

Tank characteristics : No.2 Cargo Hold Init. Frame : 138 Final Frame : 173 Use :Cargo Hold Position : Centre

Reg. Yes No Na Space boundaries

II-2/54 8.1 A60 insulation for bulkheads separating the cargo space from a machinery space of category A X

II-2/54 8.2 A60 insulation for decks separating the cargo space from a machinery space of category A X

IMSBC 9.3 Space boundaries

IMSBC 9.3.2 Heated fuel tanks are arranged adjacent to the cargo space X

IMSBC 9.3.1 Boundaries of cargo space are resistant to fire and liquids. X

Fire Main

II-2/54 1.1 Permanent pressurisation of the fire main X

II-2/54 1.1bis Remote starting arrangement of fire pumps X

II-2/54 1.2 Fire main capable of suppying four nozzles X

Hydrants arranged so that four nozzles can be trained on any part of the cargo space X

II-2/54 1.3 Water spray system fitted with an application rate of at least 5L/m²/mn X

Electrical equipment

II-2/54 2 No electrical equipment except certified safe type (IIB, T4) X

Cable penetration sealed X

Cables protected against damage from impact X

IMSBC 9.3.2 Any electrical circuits terminating in the cargo space can be electrically disconnected from the power source at a point external to the space.

X

Fire protection, detection and alarm

II-2/54 3 Approved fire detection and fire alarm system X

II-2/54 7 Portable fire extinguishers with a total capacity of at least 12kg of dry powder are provided X

II-2/54 10 Cargo space fitted with a CO2 fixed fire fighting system X

IMSBC 3.4 Facilities for introducing carbon dioxide or another inert gas into the cargo space. X

Ventilation

II-2/54 4 Mechanical ventilation with a flow rate of more than 6 renewals per hour X

Fans are to be anti-sparking X

Openings are to be fitted with mesh guards (=< 13mm) X

Electrical motors, if fitted in the ducts, are to be of a safe type X

IMSBC 3.5 The cargo spaces are ventilated by at least two separate fans. X

Bilge arrangement

II-2/54 5.1 Means are provided to avoid inadvertent pumping in engine room (e.g. blanks on bilge lines at the ER bulkhead

X

II-2/54 5.2 Additional draining means are provided X

Personnel protection

II-2/54 6.1 Four sets of full protective clothing resistant to chemical attack provided in addition to fireman outfits

X

II-2/54 6.2 Two self contained breathing apparatuses in addition to fireman outfits X

Page 28: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 28/31

Tank characteristics : No.3 Cargo Hold Init. Frame : 103 Final Frame : 138 Use :Cargo Hold Position : Centre

Reg. Yes No Na Space boundaries

II-2/54 8.1 A60 insulation for bulkheads separating the cargo space from a machinery space of category A X

II-2/54 8.2 A60 insulation for decks separating the cargo space from a machinery space of category A X

IMSBC 9.3 Space boundaries

IMSBC 9.3.2 Heated fuel tanks are arranged adjacent to the cargo space X

IMSBC 9.3.1 Boundaries of cargo space are resistant to fire and liquids. X

Fire Main

II-2/54 1.1 Permanent pressurisation of the fire main X

II-2/54 1.1bis Remote starting arrangement of fire pumps X

II-2/54 1.2 Fire main capable of suppying four nozzles X

Hydrants arranged so that four nozzles can be trained on any part of the cargo space X

II-2/54 1.3 Water spray system fitted with an application rate of at least 5L/m²/mn X

Electrical equipment

II-2/54 2 No electrical equipment except certified safe type (IIB, T4) X

Cable penetration sealed X

Cables protected against damage from impact X

IMSBC 9.3.2 Any electrical circuits terminating in the cargo space can be electrically disconnected from the power source at a point external to the space.

X

Fire protection, detection and alarm

II-2/54 3 Approved fire detection and fire alarm system X

II-2/54 7 Portable fire extinguishers with a total capacity of at least 12kg of dry powder are provided X

II-2/54 10 Cargo space fitted with a CO2 fixed fire fighting system X

IMSBC 3.4 Facilities for introducing carbon dioxide or another inert gas into the cargo space. X

Ventilation

II-2/54 4 Mechanical ventilation with a flow rate of more than 6 renewals per hour X

Fans are to be anti-sparking X

Openings are to be fitted with mesh guards (=< 13mm) X

Electrical motors, if fitted in the ducts, are to be of a safe type X

IMSBC 3.5 The cargo spaces are ventilated by at least two separate fans. X

Bilge arrangement

II-2/54 5.1 Means are provided to avoid inadvertent pumping in engine room (e.g. blanks on bilge lines at the ER bulkhead

X

II-2/54 5.2 Additional draining means are provided X

Personnel protection

II-2/54 6.1 Four sets of full protective clothing resistant to chemical attack provided in addition to fireman outfits

X

II-2/54 6.2 Two self contained breathing apparatuses in addition to fireman outfits X

Tank characteristics : No.4 Cargo Hold Init. Frame : 68 Final Frame : 103 Use :Cargo Hold Position : Centre

Reg. Yes No Na Space boundaries

II-2/54 8.1 A60 insulation for bulkheads separating the cargo space from a machinery space of category A X

II-2/54 8.2 A60 insulation for decks separating the cargo space from a machinery space of category A X

Page 29: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 29/31

IMSBC 9.3 Space boundaries

IMSBC 9.3.2 Heated fuel tanks are arranged adjacent to the cargo space X

IMSBC 9.3.1 Boundaries of cargo space are resistant to fire and liquids. X

Fire Main

II-2/54 1.1 Permanent pressurisation of the fire main X

II-2/54 1.1bis Remote starting arrangement of fire pumps X

II-2/54 1.2 Fire main capable of suppying four nozzles X

Hydrants arranged so that four nozzles can be trained on any part of the cargo space X

II-2/54 1.3 Water spray system fitted with an application rate of at least 5L/m²/mn X

Electrical equipment

II-2/54 2 No electrical equipment except certified safe type (IIB, T4) X

Cable penetration sealed X

Cables protected against damage from impact X

IMSBC 9.3.2 Any electrical circuits terminating in the cargo space can be electrically disconnected from the power source at a point external to the space.

X

Fire protection, detection and alarm

II-2/54 3 Approved fire detection and fire alarm system X

II-2/54 7 Portable fire extinguishers with a total capacity of at least 12kg of dry powder are provided X

II-2/54 10 Cargo space fitted with a CO2 fixed fire fighting system X

IMSBC 3.4 Facilities for introducing carbon dioxide or another inert gas into the cargo space. X

Ventilation

II-2/54 4 Mechanical ventilation with a flow rate of more than 6 renewals per hour X

Fans are to be anti-sparking X

Openings are to be fitted with mesh guards (=< 13mm) X

Electrical motors, if fitted in the ducts, are to be of a safe type X

IMSBC 3.5 The cargo spaces are ventilated by at least two separate fans. X

Bilge arrangement

II-2/54 5.1 Means are provided to avoid inadvertent pumping in engine room (e.g. blanks on bilge lines at the ER bulkhead

X

II-2/54 5.2 Additional draining means are provided X

Personnel protection

II-2/54 6.1 Four sets of full protective clothing resistant to chemical attack provided in addition to fireman outfits

X

II-2/54 6.2 Two self contained breathing apparatuses in addition to fireman outfits X

Tank characteristics : No.5 Cargo Hold Init. Frame : 34 Final Frame : 68 Use :Cargo Hold Position : Centre

Reg. Yes No Na Space boundaries

II-2/54 8.1 A60 insulation for bulkheads separating the cargo space from a machinery space of category A X

II-2/54 8.2 A60 insulation for decks separating the cargo space from a machinery space of category A X

IMSBC 9.3 Space boundaries

IMSBC 9.3.2 Heated fuel tanks are arranged adjacent to the cargo space X

IMSBC 9.3.1 Boundaries of cargo space are resistant to fire and liquids. X

Fire Main

II-2/54 1.1 Permanent pressurisation of the fire main X

II-2/54 1.1bis Remote starting arrangement of fire pumps X

Page 30: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 30/31

II-2/54 1.2 Fire main capable of suppying four nozzles X

Hydrants arranged so that four nozzles can be trained on any part of the cargo space X

II-2/54 1.3 Water spray system fitted with an application rate of at least 5L/m²/mn X

Electrical equipment

II-2/54 2 No electrical equipment except certified safe type (IIB, T4) X

Cable penetration sealed X

Cables protected against damage from impact X

IMSBC 9.3.2 Any electrical circuits terminating in the cargo space can be electrically disconnected from the power source at a point external to the space.

X

Fire protection, detection and alarm

II-2/54 3 Approved fire detection and fire alarm system X

II-2/54 7 Portable fire extinguishers with a total capacity of at least 12kg of dry powder are provided X

II-2/54 10 Cargo space fitted with a CO2 fixed fire fighting system X

IMSBC 3.4 Facilities for introducing carbon dioxide or another inert gas into the cargo space. X

Ventilation

II-2/54 4 Mechanical ventilation with a flow rate of more than 6 renewals per hour X

Fans are to be anti-sparking X

Openings are to be fitted with mesh guards (=< 13mm) X

Electrical motors, if fitted in the ducts, are to be of a safe type X

IMSBC 3.5 The cargo spaces are ventilated by at least two separate fans. X

Bilge arrangement

II-2/54 5.1 Means are provided to avoid inadvertent pumping in engine room (e.g. blanks on bilge lines at the ER bulkhead

X

II-2/54 5.2 Additional draining means are provided X

Personnel protection

II-2/54 6.1 Four sets of full protective clothing resistant to chemical attack provided in addition to fireman outfits

X

II-2/54 6.2 Two self contained breathing apparatuses in addition to fireman outfits X

Page 31: A60 Compliant

Reg: 08112U AFRICAN JAGUAR Ref: DRB0/2012/J0251

BUREAU VERITAS - Marine Division -

The latest published Rules of Bureau Veritas Marine Division and the General Conditions therein are applicable Page 31/31

LIST OF DOCUMENTS ATTACHED TO JOB NUMBER DRB0/2012/J0251

boiler safety valves (Electronic document attached) AF cert. (Electronic document attached) AIS report (Electronic document attached) EPIRB report (Electronic document attached) VDR report (Electronic document attached) flag agreement (Electronic document attached) WPS (Electronic document attached) repair reports (Electronic document attached) RFS (Electronic document attached) NDT repairs (Electronic document attached) poker gauge readings (Electronic document attached) gas detector calibration (Electronic document attached) anchor chain cert & calibration (Electronic document attached) utm report (Electronic document attached) Signed UT Report (Electronic document attached) Lifeboat Davit Reports (Electronic document attached) Opening meeting minutes (Electronic document attached) End of List