7
CANALINA DI APPOGGIO TETTO MONTAUTO CON FUNZIONE DI SCOLO ACQUA PIOVANA PAVIMENTAZIONE POSATA SUL TETTO DEL MODELLO A3 PAVIMENTAZIONE POSATA SUL PIANO TERRA TUBAZIONE Ø40 SPESSORE DEL PAVIMENTO (20-30 MM) COLLANTE COMPRESO PIPE-LINE Ø 40 FLOOR LAID ON THE ROOF OF THE A3 MODEL FLOOR LAID ON THE GROUND FLOOR CAR LIFT SUPPORT DUCT WITH RAINWATER DRAINAGE FUNCTION FLOOR THICKNESS (20-30MM) GLUE INCLUDED MISURE ESPRESSE IN mm PESO E PORTATATA IN Kg MODELLO PROFONDITA FOSSA DIMENSIONI FOSSA DIMENSIONI PIANALE PORTATA PESO TENSIONE STANDARD LARGO EXTRALARGO 2500-3000 380 volt A LUNGH. LARGH. LUNGH. B C D LARGH. INTERPIANO UTILE *E F 2600 2700 2800 5360 5300 5300 5300 2540 2640 2740 2200 2300 2400 DISTANZA TRA LE COLONNE G 1950-2000 MODEL CAPACITY FOR EACH PLATFORM WEIGHT TENSIONE LENGHT WIDTH DISTANCE BETWEEN THE COLUMNS WIDTH LENGHT 5400 5500 HOLE DEPHT HOLE DIMENSIONS PLATFORM DIMENSIONS DISTANCE BETWEEN THE PLANES 5360 5360 380 volt 380 volt PARCHEGGIO A SCOMPARSA"CMC COVER A3 PORTATA POSTO AUTO 2500 Kg PAVIMENTAZIONE ESCLUSA" EXTRACTABLE PARK" CMC COVER A3 CAPACITY KG 2500 EXCLUDED FLOOR" (La greenpark srl si riserva il diritto di apportare modifiche alle specifiche tecniche) GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303 www.greenparksrl.it mail: [email protected] (Greenparksrl reserves the right to modify the technical specifications ) 5200 5200 5200 1950-2000 1950-2000 5600 LOCALE TECNICO ACCESSIBILE DALL'ESTERNO TECHNICAL AREA REACHABLE FROM OUTSIDE POSTO AUTO 2500-3000 2500-3000

Upload: paolo-poltronieri

Post on 15-Oct-2014

132 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

CANALINA DI APPOGGIO TETTOMONTAUTO CON FUNZIONE DI

SCOLO ACQUA PIOVANA

PAVIMENTAZIONE POSATA SULTETTO DEL MODELLO A3

PAVIMENTAZIONE POSATA SULPIANO TERRA

TUBAZIONE Ø40

SPESSORE DEL PAVIMENTO(20-30 MM) COLLANTE COMPRESO

PIPE-LINE Ø 40

FLOOR LAID ON THE ROOFOF THE A3 MODEL

FLOOR LAID ON THEGROUND FLOOR

CAR LIFT SUPPORT DUCTWITH RAINWATER

DRAINAGE FUNCTION

FLOOR THICKNESS(20-30MM) GLUE INCLUDED

MISURE ESPRESSE IN mm PESO E PORTATATA IN Kg

MODELLO

PROFONDITAFOSSA

DIMENSIONI FOSSA DIMENSIONI PIANALE PORTATA

PESO TENSIONE

STANDARD

LARGO

EXTRALARGO

2500-3000 380 volt

ALUNGH. LARGH. LUNGH.

B C DLARGH.

INTERPIANOUTILE

*EF

2600

2700

2800

5360 5300

5300

5300

2540

2640

2740

2200

2300

2400

DISTANZA TRALE COLONNE

G

1950-2000

MODEL CAPACITYFOR EACHPLATFORM

WEIGHT TENSIONE

LENGHTWIDTH

DISTANCEBETWEEN THE

COLUMNSWIDTH LENGHT

5400

5500

HOLEDEPHT

HOLE DIMENSIONS PLATFORM DIMENSIONSDISTANCE BETWEEN

THE PLANES

5360

5360

380 volt

380 volt

PARCHEGGIO A SCOMPARSA"CMC COVER A3 PORTATAPOSTO AUTO 2500 Kg PAVIMENTAZIONE ESCLUSA"

EXTRACTABLE PARK" CMC COVER A3CAPACITY KG 2500 EXCLUDED FLOOR"

(La greenpark srl si riserva il diritto di apportare modifiche alle specifiche tecniche)

GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303www.greenparksrl.it mail: [email protected]

(Greenparksrl reserves the right to modify the technical specifications )

5200

5200

5200

1950-2000

1950-2000

5600

LOCALE TECNICOACCESSIBILE

DALL'ESTERNO

TECHNICAL AREAREACHABLE FROM

OUTSIDE

POSTOAUTO

2500-3000

2500-3000

Page 2: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

POSSIBILI SOLUZIONISOME POSSIBLE SOLUTIONS

CONVENIENT SOLUTION ABLE TO CONFERER TO THE PLANT A COMPLETEDISCRETION GARANTEED A TOTAL PROTECTION TOO.

POSSIBILI FINITURE SUL PIANALEPOSSIBLE FINISH ON THE PLATFORM

RESISTENTE ED ELEGANTE, OFFRE ILMASSIMO DEL COMFORT E SI ABBINAMERAVIGLIOSAMENTE CREANDOUN'OASI SIMBIOTICA CON L'AMBIENTECIRCOSTANTE

IL PVC VIENE IMPIEGATO PERRIVESTIRE I PIANALI GREENPARKPOICHE CONSENTE DI REALIZZAREQUALSIASI TIPO DI DESIGN CON UNPESO RIDOTTO E UNO SPESSOREMINIMO (min. 5mm - max 25mm)

QUESTO MATERIALE INNOVATIVO SIPRESTA BENISSIMO AL RIVESTIMENTODEI PIANALI GREENPARKCONFERENDO LORO UN ASPETTORISPETTOSO DELL'AMBIENTE OVEINSERITO

PVC IS EMPLOYED TO COVER GREENPARK'SPLATFORMS BECAUSE YOU CAN REALIZED WITHIT EVERY KIND SOLUTION ALSO WITH ITSREDUCED WEIGHT AND MINIMUM THICKNESS

HIGH RESISTANT AND ELEGANT SOLUTION TOCOVER OUR PLATFORM IN RESPECTING WITHTHE NEIGHBORS PLACES

THIS INNOVATE MATERIAL IS BETTER SOLUTIONTO RESPECT NATURE AND PLACE WHERE THECARLIFT IS POSITIONATED

RIVESTIMENTO IN LEGNO RIVESTIMENTO IN PVC RIV. IN ERBA SINTETICA

IL TETTO OFFRE LA POSSIBILITA' DIACCOGLIERE UNA PAVIMENTAZIONE DIQUALSIASI TIPO E FINITURA.

THE ROOF OFFERS THE OPPORTUNITY TO COVERIT WITH AL TYPES

PIANALE PAVIMENTATO

THE ROOF OF THIS MODEL IS CONCEIVED TO ENCLOSE THE FLOORRESPECTING IN THIS WAY THE PLACES WHERE IT WILL BEINCORPORATER

GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303www.greenparksrl.it mail: [email protected]

Page 3: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

800

650

850

300

600

1100

MOTORE TIPO POTENZA

(HP)(kW)

TENSIONE ELETTRICA GIRI MOTORE

(g/1')

ASSORB.SPUNTO

centralina

centralina 7.55.5

380 Volt

380 Volt

1400

1400 19.2 11

(V) (A)

UNIT

KIND OF ENGINEPOWER ELECTRIC VOLTAGE ENGINE RMP STARTING ABSORP. FUNCTIONING ABSORP.

UNIT

POSIZIONAMENTO VANO TECNICO E BOCCHE D'AREAZIONE

TECHNICAL COMPARTMENT POSITIONING AND AIR VENTS

(A)

ASSORB. A REGIME

TUBAZIONE Ø100mm PER COLLEGAMENTOVANO TECNICO VANO CORSA

connection pipe, diameter 100mm, from thetechnical compartment to the lift shaft

PULSANTIERA DI COMANDO POSIZIONATAAD 1200mm DA TERRA

CONTROL PANEL PLACED AT 1.20MMFROM THE GROUND

PIANO TERRA: POSIZIONE FOTOCELLULE

LA GREEN PARK SRL FORNIRA' AL CLIENTE TUTTI GLI SCHEMI NECESSARI PER LA PREDISPOSIZIONE IN OPERA DELLE TUBAZIONI CORRUGATE UTILI PER ILCOLLEGAMENTO TRA I VARI AUTOMATISMI E LA ZONA CENTRALINA.

CENTRALINA IDRAULICA CONFORME ALLE NORMEDELLA DIRETTIVA MACCHINE 2006 / 42 / CE

QUADRO MACCHINA CONFORME ALLANORMA CEI-EN 60439-1 CEI 17-13 / 1

GREEN PARK SRL SUPPLIES ALL THE DRAWINGS NECESSARY TO PREDISPOSE THE WRINKLED'S NET FOT AUTOMATISM OF THE WHOLE PLANT

HYDRAULIC UNIT IN ACCORDING WITH THELAW 2006 / 42 / CE

ELECTRICAL BOARD IN ACCORDING WITH THELAW CEI EN 60439-I CEI 17-13 / 1

CON QUESTA FOTOCELLULA ÈPOSSIBILE EVITARE IL PERICOLO DISCHIACCIAMENTO DURANTE LAMOVIMENTAZIONE SENZA TOGLIERESPAZIO ALL'AREA DI MANOVRA.

Thanks to this particular kind ofphotocell we can protect the entiresides of the hole, without wastingthe necessary manovring space

FOTOCELLULA CARRABILEPOSIZIONATA COME IN FIGURAPHOTOCELLS WITHCARRIAGEBLE SUPPORT ASPOSITIONATER AS THE DETAIL

N°4 FOTOCELLULE DA POSIZIONAREAD UNA DISTANZA DI 100mmDALL'ANGOLO DELLA FOSSA

N°4 PHOTOCELLS TO BE PLACED AT100mm FROM THE HOLE'S CORNER

LARGHEZZA 95mmALTEZZA 180mmSPESSORE 80mm

WIDTHHEIGHT

THICKNESS

PAVIMENTAZIONEMOD. 30 QL= 60-70 Kg/M²MOD. 50 QL= 70-100 Kg/M²

MAXIMUM PAVEMENT WEIGHT30 QL MODEL = 60-70 KG/M²50 QL MODEL = 80-100 KG/M²

VANO A BOCCA DI LUPO PERAREAZIONE FOSSA, COMPLETO DIPOZZETTO DI RACCOLTA ACQUA

A FONDO PERDUTOOPEN SPACE FOR THE VENTILATIONOF THE HOLE, COMPLETED WITH A

WATER COLLECTION PIT

PORTA D'ACCESSO AL VANO ASCENSORE DAUTILIZZARE PER OPERE DI MANUTENZIONEENTERING DOOR TO THE LIFT PLATFORM TO BE

USED FOR MAINTENANCE OPERATIONS

LOCALE TECNICO ACCESSIBILE DALL'ESTERNO MEDIANTEBOTOLA COSTITUITA DA UNA GRIGLIA D'ACCIAIO PERCONSENTIRE IL RICIRCOLO D'ARIA ANTICONDENSATECHNICAL AREA REACHABLE FROM THE OUTSIDE THROUGH ATRAPDOR, COMPOSED BY A STEEL GRATING THAT ALLOWS AIR

CIRCULATION AVOIDING CONDENSATION

SEZIONE DELLA CANALINA DIRACCOLTA ACQUA

SECTION OF THERAINWATER COLLECTOR

PIANALE: RETI DI PROTEZIONE

SOLUZIONE AGGIUNTIVA DAAPPLICARE AL MODELLO CMCCOVER B2. LA PRESENZA DELLEPROTEZIONI PERIMETRALICONFERISCONO A QUESTOMODELLO UNA TOTALESICUREZZA E PROTEZIONEDURANTE L'UTILIZZO

Thanks to this particular kind of photocell we can protect the entiresides of the hole, without wasting the necessary manovring space

5.54 14.5 9-10

GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303 www.greenparksrl.it mail: [email protected]

filo fossapit's edge

FOTOCELLULAPHOTOCELL15

0

150

Page 4: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

POSIZIONAMENTO CANALINAPOSITION OF THE CHANNEL RAINWATER COLLECTOR

65

65

100

5

INGRANDIMENTO DELLASEZIONE DELLA CANALINA

THE CHANNEL RAINWATER COLLECTOR IS PLACED ON THE UPPER EDGE OFTHE LIFT.HE HAS GOT THE FUNCTION OF RAINWATER COLLECT AND HE HAS THEFUNCTION TO SUPPORT THE COVERING ROOF.

THE CHANNEL RAINWATER COLLECTOR FIXEDAT THE ESTABLISHED MEASURE , TO CEMENTIT AT THE FLOOR

THE CHANNEL RAINWATER COLLECTOR WILLPLACED BEFORE THE TILES LAYING WITH THERELATIVE TAR MANTLE

THE DUCT WILL PLACED AT THE SAME LEVELOF THE HOLE

GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303www.greenparksrl.it mail: [email protected]

Page 5: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

IL FONDO DELLA FOSSA PU0' ESSERE REALIZZATOCON UN PIANO UNIFORME DI CALCESTRUZZOARMATO COMPLETAMENTE PRIVO DI PENDENZA,OPPURE RISPETTANDO I DUE PUNTI D'APPOGGIORAFFIGURATI NELLA VISTA IN PIANTA.THE BOTTOM OF THE HOLE CAN BE PRODUCED BY USING ANHOMOGENEUS CONCRETE PLATFORM WITH NO INCLINATION,OR BY RESPECTING TWO FULCRUMS AS SPECIFIED IN THE MAPVIEW

SOLLECITAZIONI ED ANCORAGGISTRESSES AND FASTENERS

LE SEGUENTI QUOTE SONO RIFERITE AL MODELLO CMC COVER A3 LARGO

The follwing levels are referred to the wide CMC COVER A3 LARGO

STANDARDLARGOEXTRALARGO

N1N1N1

CARICHI STRESSES

N2N2N2

55 kN 5500Kg

57 kN 5700Kg

60 kN 6000Kg

4.0 kN 400Kg

4.2 kN 420Kg

4.4 kN 440Kg

VALORI CALCOLATI CON UNA PAVIMENTAZIONE DI 20-30 mmcalculated for a thickness floor of 20-30 mm

2700

5200

SEZIONE FRONTALEFRONTAL VIEW

VISTA IN PIANTAMAP VIEW

800 800

PUNTI D'APPOGGIO DELPANTOGRAFO DA

REALIZZARE PRIVI DIPENDENZA

THE FLOOR STRIPE MUST BEREALIZED WITHOUT SLOPE

300

GREEN PARK SRL - VIA DEI COLLI n°30 - 25013 CARPENEDOLO (BS) - TEL.030/9698822 FAX 030/969303 www.greenparksrl.it mail: [email protected]

PUNTI D'APPOGGIO IN CEMENTOARMATO

REINFORCED CONCRETEFULCRUMS

GRIGLIA DI RACCOLTAACQUA PIOVANArainwater collection grid

800

300

5360

2700

800

N1

N1

N1

N1

N2

Page 6: A3 Parcheggio Int. a Due Posti Sovrapposti Scheda Tec

FORNIRE UNA ADEGUATA ILLUMINAZIONE SU ENTRAMBI I PIANI DI CARICO IN MODO DA OTTENERE UNA BUONA VISIONE DELLEMANOVRA DI MOVIMENTAZIONE

PULSANTIERA DI COMANDO A TENUTA STAGNA, POSIZIONATA ALL'ESTERNO DELLA MACCHINA IN POSIZIONE FAVOREVOLE ADUN CONTROLLO DELLE MANOVRE DI MOVIMENTAZIONE, COMPLETA DI LAMPEGGIANTE CON PULSANTI LUMINOSI DISEGNALAZIONE PIANI, CHIAVE ESTRAIBILE E PULSANTE DI EMERGENZA.

SEZIONATORE GENERALE DI ALIMENTAZIONE ELETTRICA MUNITO DI DISPOSITIVO DI CHIUSURA PER IMPEDIRE L'AZIONAMENTODA PARTE DI PERSONALE NON AUTORIZZATO.

DATI TECNICITECNICAL DETAILS

PARCHEGGIO A SCOMPARSA MOD.CMC COVER B2: DISPOSITIVI DI SICUREZZA PRESENTI

FOTOCELLULE PERIMETRALI PER EVITARE IL PERICOLO DI SCHIACCIAMENTO O CESOIAMENTO

PIANALE RIVESTITO IN LAMIERA ZINCATA A CALDO STRIATA O BUGNATA CON RILIEVO TIPO"MANDORLATO".

VALVOLE DI TENUTA MONTATE DIRETTAMENTE SUI MARTINETTI DI SPINTA .

TUBAZIONI IN ACCIAIO CATEGORIA R2.

VALVOLA DI MASSIMA PRESSIONE PER SOVRACCARICHI.

VALVOLA DI BLOCCO CONTRO IL RISCHIO DI ROTTURA CIRCUITO IDRAULICO.

IMPIANTO ELETTRICO IN BASSA TENSIONE (24 VOLT) CON FUNZIONAMENTO AD "UOMOPRESENTE".

DISPOSITIVO MECCANICO DI SICUREZZA PER MANUTENZIONI.

PLATFORM COVERED BY HOT GALVANIZED STEEL PLATE MOD. STRIPED OR SKEPPED

ELECTRICAL WIRING IN LOW TENSION 24V WITH FUNCTIONING WITH DEAD MAN SWITCH.

PIPES MADE IN STEEL R2 CATEGORY

MECHANICAL SAFE DEVICE USED IN MAINTENANCE

LOCKED VALVE AGAINST DEMAGES OF HYDRAULIC CIRCUIT

MAXIMAL PRESSION VALVE NECESSARY FOR OVERLOAD

SAFETY VALVE DIRECTLY FIXED ON THE CYLINDERS

PERIMETRAL PHOTOCELL INSTALLED AT THE GROUND FLOOR TO AVOID SHEARING HAZARD

CONTROL PANEL WATERLIGHT COMPARTMENTS, PLACED EXTERNAL OF THE MACHINERY IN FAVOURABLE LOCATION TO HAVEAN OPTIMAL VIEW WHILE THE MANOUVRES ARE DOING, THIS PANEL HAVE GOT A FLASHING INDICATOR , EMERGENCY PUSHBOTTON AND PULLING OUT KEY

SWITCH CABINET WITH LOCKED FOR CLOSE IT

ADEQUATE ILLUMINATION AT BOTH FLOOR NECESSARY TO SEE VERY WELL ALL THE MANOUVRES

FOTOCELLULE

POSSIBILITY TO INSTALL A PROTECTIVE WIRE NET MADE IN HOT GALVANIZED STEEL WITH LINK OF 10mm

RETI DI PROTEZIONE

FERMARUOTA MECCANICO PER CORRETTO POSIZIONAMENTO DELLA VETTURA

POSSIBILITA DI APPLICARE RETI DI PROTEZIONE IN ACCIAIO ZINCATO A CALDO IN LAMIERAMICROFORATA CON MAGLIA NON INFERIORE A 10mm

STOPPAGE WHEELS USED FOR POSITIONATED CORRECTLY THE CAR ON THE PLATFORM

FERMARUOTA

PULSANTIERA DICOMANDO