«a la carte» programmedonar.messe.de/.../ce-t-tsi-inverter-a-la-carte-eng... · tsi bravo shelf...
TRANSCRIPT
«Alacarte»ProgrammeThecompletemodularAC/ACandDC/ACconverterrangeupto225kVAACoutputpowersolutions
Each»module»has»AC»and»DC»input»without»need»of»a»static»switch
Dynamic»source»transfer»0mS»from»AC»to»DC»and»vice»versa
Single»point»of»failure»elimination»(no»need»of»external»static»switch)
Evolutive»architecture»A+B»without»need»of»external»static»switch
High»effi»»ciency»up»to»96%»in»normal»operationη+
TSI_ALACARTE_CET_POUR BROCHURE.indd 2 21/02/11 20:15
TSI Inverter system schematic
A & B architecture with TSI Module
ACOUT bulk bkr
TSI Modules
Battery
AC OutputDistribution
(Optional)
(Optional)
(Optional)
SNMP
DISPLAY
TSS
AC Input bkr(Optional)
Manual By-pass Switch(Optional)
AC
Inp
ut
DEG
LOAD
Feed A Feed B
A1 B1
An Bn
DEG
LOAD
TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.
Intoday’sfastmovingbusinessandclimatechanges,organisationsneedanticipation;1.Topreventdowntime,ensurethecontinuityofserviceandmaximizerevenue2.ToreduceOPEXandoptimizeCAPEX3.Totakeintoconsiderationenvironmentalfactor
»» »The»«A»la»carte»»programme»is»structured»around»a»complete»module»range»of»500VA,»750VA,»1500VA,»2500VA»output»power
»» »Each»module»is»equipped»with»dual»AC»and»DC»input»(except»500VA)»» A»dynamic»source»transfer»garantees»switching»from»AC»to»DC»with»
» 0»mS»transfer»time»and»vice»versa.»»» TSI»systems»can»operate»in»2»working»mode»» »EPCmode
While»AC»input»mains»is»present»a»double»conversion»AC/DC»and»DC/AC»with»96%»effi»»ciency»supplies»a»pure»stabilized»AC»output»voltage.»In»case»of»AC»input»failure»a»dynamic»source»transfer»ensures»the»transition»of»power»to»the»DC»battery»without»interruption.»
» Onlinemode»DC»input»battery»is»the»primary»source»and»converted»into»a»pure»stabilized»»AC»ouput.»In»case»of»battery»or»DC»failure»the»AC»load»will»be»transfered»on»AC»input»source
»» »η+ EPC»mode»has»up»to»96%»effi»»ciency»and»reduce»signifi»cantly»the»losses»compared»to»conventional»DC/AC»inverter.»It»also»has»a»positive»impact»on»environnement»and»reduces»signifi»cantly»the»operation»costs.»
»Applications&advantages
»» »The»TSI»technology»is»ideal»in»ICT»and»Industry»installations»where»DC»batteries»are»present»and»critical»applications»need»a»reliable»AC»output»power»with»long»battery»back»up»time»up»to»225kVA»single»or»3»phases.
»» »By»adding»Modular»battery»charger»we»can»build»Modular»UPS»with»long»battery»back»up»time.
»» »Possibility»to»realize»A+B»installation»without»static»switches.»» »Elimination»of»external»static»switch»and»rectifi»er»are»sized»only»to»
charge»battery.»» »Expandable»system»up»to»225kVA»and»modular»architecture.»» »AC»mains»fi»ltering»(unity»power»factor»ACin).»»» AC»output»stabilized»at»230VAC»with»ACin»from»150VAC»to»265VAC.»» »Simplifi»ed»installation»and»commissioning.
TSI_ALACARTE_CET_POUR BROCHURE.indd 3 21/02/11 20:15
TSI programme «A La Carte» off ers a unique confi guration tool to customize the TSI solution ready to use to secure the power supply of your criticalACloadapplication.
TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.
Weoff ermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.
»» »Easy»installation»:»terminations»and»connections»are»located»in»one»«cold»zone»»area»providing»easy»cable»access,»fi»xing»and»termination»point»for»AC»input,»DC»input,»AC»output»and»alarms»connections.
»» Tested»&»certifi»ed»:»All»CE+T»Power»systems»have»been»tested»for»vibrations,»high»operating»T°»and»EMC»to»grant»excellent»operation»in»severe»environment.
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110987654321 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT:
A0
SHEET 2 OF 2SCALE:1:2
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
Termination Box
AC distribution line (Optional)
Manual By Pass (Optional)
DC input protectionBreaker (Optional)
TSI Bravo Shelf and TSI Bravo modulesPhase 1
TSI Bravo Shelf and TSI Bravo modulesPhase 2
TSI Bravo Shelf and TSI Bravo modulesPhase 3
Cabinet Footprint 600x600mm (WxD)
CANDIS Display & TCP-IP (Optional)
75kVA system 3 phases in CE+T Power cabinet600x600x2100 mm (WxDxH)
TSI_ALACARTE_CET_POUR BROCHURE.indd 4 21/02/11 20:15
TSI Inverter system schematic
A & B architecture with TSI Module
ACOUT bulk bkr
TSI Modules
Battery
AC OutputDistribution
(Optional)
(Optional)
(Optional)
SNMP
DISPLAY
TSS
AC Input bkr(Optional)
Manual By-pass Switch(Optional)
AC
Inp
ut
DEG
LOAD
Feed A Feed B
A1 B1
An Bn
DEG
LOAD
TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.
Intoday’sfastmovingbusinessandclimatechanges,organisationsneedanticipation;1.Topreventdowntime,ensurethecontinuityofserviceandmaximizerevenue2.ToreduceOPEXandoptimizeCAPEX3.Totakeintoconsiderationenvironmentalfactor
»» »The»«A»la»carte»»programme»is»structured»around»a»complete»module»range»of»500VA,»750VA,»1500VA,»2500VA»output»power
»» »Each»module»is»equipped»with»dual»AC»and»DC»input»(except»500VA)»» A»dynamic»source»transfer»garantees»switching»from»AC»to»DC»with»
» 0»mS»transfer»time»and»vice»versa.»»» TSI»systems»can»operate»in»2»working»mode»» »EPCmode
While»AC»input»mains»is»present»a»double»conversion»AC/DC»and»DC/AC»with»96%»effi»»ciency»supplies»a»pure»stabilized»AC»output»voltage.»In»case»of»AC»input»failure»a»dynamic»source»transfer»ensures»the»transition»of»power»to»the»DC»battery»without»interruption.»
» Onlinemode»DC»input»battery»is»the»primary»source»and»converted»into»a»pure»stabilized»»AC»ouput.»In»case»of»battery»or»DC»failure»the»AC»load»will»be»transfered»on»AC»input»source
»» »η+ EPC»mode»has»up»to»96%»effi»»ciency»and»reduce»signifi»cantly»the»losses»compared»to»conventional»DC/AC»inverter.»It»also»has»a»positive»impact»on»environnement»and»reduces»signifi»cantly»the»operation»costs.»
»Applications&advantages
»» »The»TSI»technology»is»ideal»in»ICT»and»Industry»installations»where»DC»batteries»are»present»and»critical»applications»need»a»reliable»AC»output»power»with»long»battery»back»up»time»up»to»225kVA»single»or»3»phases.
»» »By»adding»Modular»battery»charger»we»can»build»Modular»UPS»with»long»battery»back»up»time.
»» »Possibility»to»realize»A+B»installation»without»static»switches.»» »Elimination»of»external»static»switch»and»rectifi»er»are»sized»only»to»
charge»battery.»» »Expandable»system»up»to»225kVA»and»modular»architecture.»» »AC»mains»fi»ltering»(unity»power»factor»ACin).»»» AC»output»stabilized»at»230VAC»with»ACin»from»150VAC»to»265VAC.»» »Simplifi»ed»installation»and»commissioning.
TSI_ALACARTE_CET_POUR BROCHURE.indd 3 21/02/11 20:15
TSI programme «A La Carte» off ers a unique confi guration tool to customize the TSI solution ready to use to secure the power supply of your criticalACloadapplication.
TechnologyinactionTSIisanadvancedstepinDC/ACmodularconvertertechnology.Offeringhigherpower,higherefficiency,loweroperationcostandhavingapositivecarbonimpact.
Weoff ermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.
»» »Easy»installation»:»terminations»and»connections»are»located»in»one»«cold»zone»»area»providing»easy»cable»access,»fi»xing»and»termination»point»for»AC»input,»DC»input,»AC»output»and»alarms»connections.
»» Tested»&»certifi»ed»:»All»CE+T»Power»systems»have»been»tested»for»vibrations,»high»operating»T°»and»EMC»to»grant»excellent»operation»in»severe»environment.
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110987654321 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT:
A0
SHEET 2 OF 2SCALE:1:2
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
Termination Box
AC distribution line (Optional)
Manual By Pass (Optional)
DC input protectionBreaker (Optional)
TSI Bravo Shelf and TSI Bravo modulesPhase 1
TSI Bravo Shelf and TSI Bravo modulesPhase 2
TSI Bravo Shelf and TSI Bravo modulesPhase 3
Cabinet Footprint 600x600mm (WxD)
CANDIS Display & TCP-IP (Optional)
75kVA system 3 phases in CE+T Power cabinet600x600x2100 mm (WxDxH)
TSI_ALACARTE_CET_POUR BROCHURE.indd 4 21/02/11 20:15
THIRD ANGLE PROJECTION
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110
98
76
54
32
1
1314
1516
1718
1920
2122
2324
12
34
56
78
910
1112
1314
1516
1718
1920 Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT: A0
SHEET 1 OF 1
SCALE:1:2
DWG NO.
TITLE:
REVISION
DO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURE
NAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
»ACoutput
»» Bulk»on»terminal»or»breaker»(option).
»» »AC»distribution»line.»Up»to»20bkr»1»pole,»10bkr»2»poles,»5bkr»3»poles»to»be»installed»live»and»safe.»Max»40A»per»breaker.
»» Single»phase»or»3»phases.
Theterminationbox isthekeysuccess inthe«ALaCarte»programmecoveringallaspecttoprovideeasy installation,commissioningandtomaximizesystemoperationwhilereducingCAPEXandOPEX.
»DCinput
»» COMMON»DC»:»each»module»can»be»protected»with»breaker»(option).
»» INDIVIDUAL»DC»:»with»or»without»breaker»(option).
»ACinput
»» Single»phase»or»3»phases.
»» Bulk»on»terminal.
»» Bulk»on»breaker»(option)
»» »3»wires»(L1,»N,»PE)»for»single»phase»and»5»wires»(L1,»L2,»L3,»N,»PE)»for»3»phases.
»ToporBottomcabling
»» Top»cabling»by»default,»all»cables»easily»fixed»with»tie»rap.
»» Bottom»cabling»on»request.
WeoffermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.
MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.
TSI_ALACARTE_CET_POUR BROCHURE.indd 5 21/02/11 20:15
THIRD ANGLE PROJECTION
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110987654321 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT:
A0
SHEET 1 OF 1SCALE:1:2
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
»Manualbypass
»» 20kVA,»40kVA,»60kVA,»80kVA»single»phase.
»» 30kVA,»75kVA»3»phases.
»» »Make»before»break»manual»by-pass»switch»only»needed»for»service»maintenance.
»Alarmterminal
»» Dry»changeover»contact»NO,»NC,»C.
-»Minor»:»minor»event»in»system.-»Major»:»major»event»in»system.-»Aux»:»user»confi»gurable»contact.
»» Contact»rating»:»0,5A»/»30VDC.
»Monitoring
Monitoring
»» 3»LEDS»local.
»» »USB»com»port»for»parameter»setting»and»to»consult»system»information»
»» »Optional»MODBUS»/»CANBUS»communication»with»other»monitoring»equipment
CANDIS display & CANDIS TCP-IP(option)
»» CANDIS»DisplayProvides»all»system»input»&»output»measurementsSingle»or»3»phases»display.Scroll»menu»push»button.
»» CANDIS TCP/IP-SNMPOff»ers»remote»access»through»Ethernet,»Web»Explorer,»SNMP»protocol.
CANDIS TCP/IP Web user Interface example.
MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.
Weallhavetowin
TSI_ALACARTE_CET_POUR BROCHURE.indd 6 21/02/11 20:15
THIRD ANGLE PROJECTION
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110
98
76
54
32
1
1314
1516
1718
1920
2122
2324
12
34
56
78
910
1112
1314
1516
1718
1920 Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT: A0
SHEET 1 OF 1
SCALE:1:2
DWG NO.
TITLE:
REVISION
DO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURE
NAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
»ACoutput
»» Bulk»on»terminal»or»breaker»(option).
»» »AC»distribution»line.»Up»to»20bkr»1»pole,»10bkr»2»poles,»5bkr»3»poles»to»be»installed»live»and»safe.»Max»40A»per»breaker.
»» Single»phase»or»3»phases.
Theterminationbox isthekeysuccess inthe«ALaCarte»programmecoveringallaspecttoprovideeasy installation,commissioningandtomaximizesystemoperationwhilereducingCAPEXandOPEX.
»DCinput
»» COMMON»DC»:»each»module»can»be»protected»with»breaker»(option).
»» INDIVIDUAL»DC»:»with»or»without»breaker»(option).
»ACinput
»» Single»phase»or»3»phases.
»» Bulk»on»terminal.
»» Bulk»on»breaker»(option)
»» »3»wires»(L1,»N,»PE)»for»single»phase»and»5»wires»(L1,»L2,»L3,»N,»PE)»for»3»phases.
»ToporBottomcabling
»» Top»cabling»by»default,»all»cables»easily»fixed»with»tie»rap.
»» Bottom»cabling»on»request.
WeoffermorethenjustanInverterOurcompletesolutioncabinetsaredesignedtoprocureeasyinstallation,easycustomerconnection,andreduceinstallationcosts.
MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.
TSI_ALACARTE_CET_POUR BROCHURE.indd 5 21/02/11 20:15
THIRD ANGLE PROJECTION
12
H
G
F
E
D
C
B
A
J
K
L
M
N
P
Q
R
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
1110987654321 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Assem6
XXX
XXX
XXX
XXXXXX
XXX
XXX
XXX
WEIGHT:
A0
SHEET 1 OF 1SCALE:1:2
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
»Manualbypass
»» 20kVA,»40kVA,»60kVA,»80kVA»single»phase.
»» 30kVA,»75kVA»3»phases.
»» »Make»before»break»manual»by-pass»switch»only»needed»for»service»maintenance.
»Alarmterminal
»» Dry»changeover»contact»NO,»NC,»C.
-»Minor»:»minor»event»in»system.-»Major»:»major»event»in»system.-»Aux»:»user»confi»gurable»contact.
»» Contact»rating»:»0,5A»/»30VDC.
»Monitoring
Monitoring
»» 3»LEDS»local.
»» »USB»com»port»for»parameter»setting»and»to»consult»system»information»
»» »Optional»MODBUS»/»CANBUS»communication»with»other»monitoring»equipment
CANDIS display & CANDIS TCP-IP(option)
»» CANDIS»DisplayProvides»all»system»input»&»output»measurementsSingle»or»3»phases»display.Scroll»menu»push»button.
»» CANDIS TCP/IP-SNMPOff»ers»remote»access»through»Ethernet,»Web»Explorer,»SNMP»protocol.
CANDIS TCP/IP Web user Interface example.
MakeyourideasgofurtherSelectthepoweryouneed,andbuildyoursolutionprogressively.
Weallhavetowin
TSI_ALACARTE_CET_POUR BROCHURE.indd 6 21/02/11 20:15
Modulerange
»» Output»500VA/400W»up»to»65°C»operation»full»power
»» Ideal»for»300mm»depth»enclosure
»» »η+ Effi»»ciency»89%»DC/AC
»» 230VAC»output»voltage
»» 48VDC»input»voltage
»VEDAModule
»» 750VA/525W»output»power»up»to»50°C»operation»full»power.
»» »η+ Effi»»ciency»93%»in»EPC»mode,»90%»DC/AC»mode
»» 230VAC»output»voltage
»» 48VDC»input»voltage
»NOVAModule
»» 1500VA/1200W»output»power»up»to»50°C»operation»full»power
»» »η+ Effi»»ciency»94%»in»EPC»mode,»90%»DC/AC»mode
»» 230VAC»and»120VAC»output»voltage
»» 48VDC»input»voltage
»MEDIAModule
»» 2500VA/2000W»output»power
»» »η+ Effi»»ciency»96%»in»EPC»mode,»91%»DC/AC»mode
»» 230VAC»and»120VAC»voltage
»» »48VDC,»60VDC,»110VDC,»24VDC»(1500VA/1200W)»input»voltage
»BRAVOModule
The«AlaCarte»programmeisbasedonacompletemodulerange.Weoff ersolutionsfrom500VAupto225kVA.
TSI_ALACARTE_CET_POUR BROCHURE.indd 7 21/02/11 20:15
«Alacarte»OverviewProgrammePleaseconsultCE+TPowerSalesforanycustomisedsolutionyouneed
»«Alacarte»48VDC,60VDC,110VDC
»Largesystemsupto225kVA
»» »Our» systems» can» be» extended» to» large» 3» phases» installations» with» up» to»3x75kVA»systems»to»deliver»an»output»power»of»225kVA.
»» »3» systems,» up» to» 75kVA» each,» are» synchronized» to» provide» a» reliable» pure»AC»output»power»for»critical»applications.
The“ALaCarte”rangeisintegratedin19inchesstandardcabinet600x600mmHeightcanbe1100,1800,2130mmdependingonpoweranddistributionline.DC input
Votage 48VDC 60VDC, 110VDC
DC output Votage 220/230VAC 3x400VAC 120VAC 120/240VAC 3x208VAC 220/230VAC 3x400VAC
Power kVA
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
3 4xNOVA2xBRAVO
1xNOVA1xBRAVO
6xNOVA3xBRAVO
3xNOVA3xBRAVO
2xMEDIA2xBRAVO
1xMEDIA1xBRAVO
2xMEDIA2xBRAVO
2xMEDIA2xBRAVO
3xMEDIA3xBRAVO
3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
5 7xNOVA2xBRAVO
2xNOVA1xBRAVO
9xNOVA3xBRAVO
6xNOVA3xBRAVO
4xMEDIA2xBRAVO
1xMEDIA1xBRAVO
4xMEDIA2xBRAVO
2xMEDIA2xBRAVO
6xMEDIA3xBRAVO
3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
6 8xNOVA3xBRAVO
2xNOVA1xBRAVO
9xNOVA3xBRAVO
6xNOVA3xBRAVO
4xMEDIA3xBRAVO
1xMEDIA1xBRAVO
4xMEDIA4xBRAVO
2xMEDIA2xBRAVO
6xMEDIA3xBRAVO
3xMEDIA3xBRAVO 3xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
9 12xNOVA4xBRAVO
3xNOVA1xBRAVO
12xNOVA6xBRAVO
3xNOVA3xBRAVO
6xMEDIA4xBRAVO
2xMEDIA1xBRAVO
6xMEDIA4xBRAVO
2xMEDIA2xBRAVO
6xMEDIA6xBRAVO
3xMEDIA3xBRAVO 4xBRAVO 1xBRAVO 6xBRAVO 3xBRAVO
12 16xNOVA5xBRAVO
4xNOVA2xBRAVO
18xNOVA6xBRAVO
6xNOVA3xBRAVO
8xMEDIA5xBRAVO
2xMEDIA2xBRAVO
8xMEDIA6xBRAVO
2xMEDIA2xBRAVO
9xMEDIA6xBRAVO
3xMEDIA3xBRAVO 5xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO
15 20xNOVA6xBRAVO
5xNOVA2xBRAVO
21xNOVA6xBRAVO
6xNOVA3xBRAVO
10xMEDIA6xBRAVO
3xMEDIA2xBRAVO
10xMEDIA6xBRAVO
4xMEDIA2xBRAVO
12xMEDIA6xBRAVO
3xMEDIA2xBRAVO 6xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO
18 24xNOVA8xBRAVO
6xNOVA2xBRAVO
24xNOVA9xBRAVO
6xNOVA3xBRAVO
12xMEDIA8xBRAVO
3xMEDIA2xBRAVO
12xMEDIA8xBRAVO
4xMEDIA2xBRAVO
12xMEDIA9xBRAVO
3xMEDIA3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO
20 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO
24 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 10xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO
30 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO
40 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO
50 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 24xBRAVO 6xBRAVO
60 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO
70 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 28xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO
75 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO
80 32xBRAVO 9xBRAVO NA NA 32xBRAVO 9xBRAVO 32xBRAVO 8xBRAVO NA NA 32xBRAVO 9xBRAVO NA NA
TSI_ALACARTE_CET_POUR BROCHURE.indd 8 21/02/11 20:15
Modulerange
»» Output»500VA/400W»up»to»65°C»operation»full»power
»» Ideal»for»300mm»depth»enclosure
»» »η+ Effi»»ciency»89%»DC/AC
»» 230VAC»output»voltage
»» 48VDC»input»voltage
»VEDAModule
»» 750VA/525W»output»power»up»to»50°C»operation»full»power.
»» »η+ Effi»»ciency»93%»in»EPC»mode,»90%»DC/AC»mode
»» 230VAC»output»voltage
»» 48VDC»input»voltage
»NOVAModule
»» 1500VA/1200W»output»power»up»to»50°C»operation»full»power
»» »η+ Effi»»ciency»94%»in»EPC»mode,»90%»DC/AC»mode
»» 230VAC»and»120VAC»output»voltage
»» 48VDC»input»voltage
»MEDIAModule
»» 2500VA/2000W»output»power
»» »η+ Effi»»ciency»96%»in»EPC»mode,»91%»DC/AC»mode
»» 230VAC»and»120VAC»voltage
»» »48VDC,»60VDC,»110VDC,»24VDC»(1500VA/1200W)»input»voltage
»BRAVOModule
The«AlaCarte»programmeisbasedonacompletemodulerange.Weoff ersolutionsfrom500VAupto225kVA.
TSI_ALACARTE_CET_POUR BROCHURE.indd 7 21/02/11 20:15
«Alacarte»OverviewProgrammePleaseconsultCE+TPowerSalesforanycustomisedsolutionyouneed
»«Alacarte»48VDC,60VDC,110VDC
»Largesystemsupto225kVA
»» »Our» systems» can» be» extended» to» large» 3» phases» installations» with» up» to»3x75kVA»systems»to»deliver»an»output»power»of»225kVA.
»» »3» systems,» up» to» 75kVA» each,» are» synchronized» to» provide» a» reliable» pure»AC»output»power»for»critical»applications.
The“ALaCarte”rangeisintegratedin19inchesstandardcabinet600x600mmHeightcanbe1100,1800,2130mmdependingonpoweranddistributionline.DC input
Votage 48VDC 60VDC, 110VDC
DC output Votage 220/230VAC 3x400VAC 120VAC 120/240VAC 3x208VAC 220/230VAC 3x400VAC
Power kVA
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
Nbr Module
Nbr Rack
3 4xNOVA2xBRAVO
1xNOVA1xBRAVO
6xNOVA3xBRAVO
3xNOVA3xBRAVO
2xMEDIA2xBRAVO
1xMEDIA1xBRAVO
2xMEDIA2xBRAVO
2xMEDIA2xBRAVO
3xMEDIA3xBRAVO
3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
5 7xNOVA2xBRAVO
2xNOVA1xBRAVO
9xNOVA3xBRAVO
6xNOVA3xBRAVO
4xMEDIA2xBRAVO
1xMEDIA1xBRAVO
4xMEDIA2xBRAVO
2xMEDIA2xBRAVO
6xMEDIA3xBRAVO
3xMEDIA3xBRAVO 2xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
6 8xNOVA3xBRAVO
2xNOVA1xBRAVO
9xNOVA3xBRAVO
6xNOVA3xBRAVO
4xMEDIA3xBRAVO
1xMEDIA1xBRAVO
4xMEDIA4xBRAVO
2xMEDIA2xBRAVO
6xMEDIA3xBRAVO
3xMEDIA3xBRAVO 3xBRAVO 1xBRAVO 3xBRAVO 3xBRAVO
9 12xNOVA4xBRAVO
3xNOVA1xBRAVO
12xNOVA6xBRAVO
3xNOVA3xBRAVO
6xMEDIA4xBRAVO
2xMEDIA1xBRAVO
6xMEDIA4xBRAVO
2xMEDIA2xBRAVO
6xMEDIA6xBRAVO
3xMEDIA3xBRAVO 4xBRAVO 1xBRAVO 6xBRAVO 3xBRAVO
12 16xNOVA5xBRAVO
4xNOVA2xBRAVO
18xNOVA6xBRAVO
6xNOVA3xBRAVO
8xMEDIA5xBRAVO
2xMEDIA2xBRAVO
8xMEDIA6xBRAVO
2xMEDIA2xBRAVO
9xMEDIA6xBRAVO
3xMEDIA3xBRAVO 5xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO
15 20xNOVA6xBRAVO
5xNOVA2xBRAVO
21xNOVA6xBRAVO
6xNOVA3xBRAVO
10xMEDIA6xBRAVO
3xMEDIA2xBRAVO
10xMEDIA6xBRAVO
4xMEDIA2xBRAVO
12xMEDIA6xBRAVO
3xMEDIA2xBRAVO 6xBRAVO 2xBRAVO 6xBRAVO 3xBRAVO
18 24xNOVA8xBRAVO
6xNOVA2xBRAVO
24xNOVA9xBRAVO
6xNOVA3xBRAVO
12xMEDIA8xBRAVO
3xMEDIA2xBRAVO
12xMEDIA8xBRAVO
4xMEDIA2xBRAVO
12xMEDIA9xBRAVO
3xMEDIA3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO
20 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO 8xBRAVO 2xBRAVO 9xBRAVO 3xBRAVO
24 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 10xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO
30 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 4xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO 12xBRAVO 3xBRAVO
40 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO 16xBRAVO 4xBRAVO 18xBRAVO 6xBRAVO
50 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 20xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 20xBRAVO 5xBRAVO 24xBRAVO 6xBRAVO
60 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO 24xBRAVO 6xBRAVO
70 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 28xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 28xBRAVO 7xBRAVO 30xBRAVO 9xBRAVO
75 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO 30xBRAVO 8xBRAVO 30xBRAVO 9xBRAVO
80 32xBRAVO 9xBRAVO NA NA 32xBRAVO 9xBRAVO 32xBRAVO 8xBRAVO NA NA 32xBRAVO 9xBRAVO NA NA
TSI_ALACARTE_CET_POUR BROCHURE.indd 8 21/02/11 20:15
S 32 A 7 3 E 04 32 C I 1 00 4 00 1
EPC ModeÀ la carte
Module Type
31 : NOVA32 : BRAVO33 : MEDIA34 : VEDA
AC Voltage
3 : 120VAC
5 : 3x208VAC
6 : 120/240VAC
7 : 220/230/240VAC
8 : 3x400VAC
DC Input
2 : 24VDC
3 : 48VDC
4 : 60VDC
5 : 110VDC
Specify number of Module to install at beginning. Here 4 modules installed.
Maximum Number of module in the system for future extension � lled with blank at beginning. Maximum 32 modules installed in the example.
Monitoring
0 : No monitoring1 : CANDIS display2 : CANDIS TCP/IP4 : CANDIS Display and TCP/IP
AC output distribution
0X : AC distribution line 1 pole0Y : AC distribution line 2 poles0Z : AC distribution line 3 poles00 : Bulk on terminal
Manual by pass
0 : No MBP1 : With MBP
Cabinet type 600mm wide
Our solutions can be integrated in any kind of ANSI or ETSI cabinet. An integration in a customized cabinet is also possible.
«A»La»Carte»»programme»consist»of»a»20»characters»code.
DC distributionCan be done at system or at module level.
Howtoorder?
CE+Ts.a.Phone»:»+32»4»345»67»00Fax»:»+32»4»345»67»01ww.cet.be
PleaseconsulttheCE+TPowersalesteamformoreinformation.
CE+TUK
Phone»:»+44»1246»25»11»11»Fax»:»+44»1246»25»11»33www.cet.be
CE+TChina
Phone»:»+86»756»853»2380»Fax»:»+86»756»853»2396www.cet-china.com
CE+TScandinaviaRegionaloffi ce
Phone»:»+46»70»3107812»Skype»:»marten.ribaeus
CE+TAmerica,Inc
Phone»:»+1»678»405»4636Fax»:»»+1»770»495»0992»www.»cetamerica.com
CETPowerSolutionsIndiaPVTLTD
Phone»:»+91»80»42764617»Email»:»[email protected]
TSI_ALACARTE_CET_POUR BROCHURE.indd 1 21/02/11 20:14