a-212 ramp elevations, sections and details abilene city
TRANSCRIPT
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:1
2 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-001
Cover Sheet
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
Abilene City Council Chambers
Renovations
City of Abilene
555 Walnut St.Abilene, TX 79601
4222 85th St.Lubbock, TX 79423806.473.2200
G-001 Cover Sheet
G-011 Symbols, Legends & Abbreviations
G-021 Accessibility Standards
G-022 Accessibility Standards
G-023 Accessibility Standards
G-024 Accessibility Standards
G-101 Code Information
A-001 Architectural / Interior Legends / Schedules
A-112 Floor Plans - Second Floor
A-211 Interior Elevations, Sections and Details
A-212 Ramp Elevations, Sections and Details
SHEET INDEX
GENERAL
ARCHITECTURAL / INTERIOR
ELECTRICALE-001 Electrical Abbreviations & Legends
E-111 Electrical Floor Plans - Second Floor
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
ABBREVIATIONSAACC ACCESSIBLEAB ANCHOR BOLTACI AMERICAN CONCRETE INSTITUTEAD AREA DRAINADA AMERICANS WITH DISABILITIES ACTADDL ADDITIONALADJ ADJUSTABLEADDM ADDENDUMAFF ABOVE FINISH FLOORAHU AIR HANDLING UNITAIA AMERICAN INSTITUTE OF ARCHITECTSAISC AMERICAN INSTITUTE OF STEEL CONSTRUCTIONALT ALTERNATEALUM ALUMINUMANOD ANODIZEDANSI AMERICAN NATIONAL STANDARDS INSTITUTEAPA AMERICAN PLYWOOD ASSOCIATIONAPPROX APPROXIMATEARCH ARCHITECTASCE AMERICAN SOCIETY OF CIVIL ENGINEERSASTM AMERICAN SOCIETY OF TESTING MATERIALSAUTO AUTOMATICAVG AVERAGEAWG AMERICAN WIRE GAGEAWS AMERICAN WELDING SOCIETYA/C AIR CONDITIONING
BBAL BALANCEBC BACK OF CURBBIA BRICK INSTITUTE OF AMERICABITUM BITUMINOUSBL BUILDING LINEBLDG BUILDINGBM BENCHMARKBOCA BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC.BOX BOTTOM OF STEELBOT BOTTOM (BOTTOM FACE, LAYER, SIDE)B PL BASE PLATEBRDG BRIDGINGBRG BEARINGBTWN BETWEENBUR BUILT-UP ROOFING
CC AMERICAN STANDARD CHANNEL (STRUCTURAL SHAPE)CU FT CUBIC FOOTCF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLEDCF/OI CONTRACTOR FURNISHED/OWNER INSTALLEDCG CORNER GUARDCI CAST IRONCIR CIRCLECIRC CIRCULARCJ CONTROL JOINTCL CENTER LINECLG CEILINGcm CENTIMETERCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONN CONNECTCONSTR CONSTRUCTIONCONT CONTINUECONTR CONTRACTORCRCMF CIRCUMFERENCECSK COUNTER SUNKCSI CONSTRUCTION SPECIFICATIONS INSTITUTE
DD DEPTHDAT DATUMDBL DOUBLEDDS DOUBLE DISPLAY STRIPDEG DEGREEDEMO DEMOLISHDET DETAILDF DRINKING FOUNTAINDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDIV DIVIDEDL DEAD LOADDS DOWNSPOUTDWG DRAW ING
EE EAST, MODULUS OF ELASTICITYEA EACHEF EACH FACE, EXTERIOR FINISHEIFS EXTERIOR INSULATION FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRIC, ELECTRICALELEV ELEVATORENGR ENGINEEREQ EQUALEQUIP EQUIPMENTEW EACH W AYEWC ELECTRIC WATER COOLEREXIST EXISTINGEXP EXPANSIONEXP BT EXPANSION BOLTEXT EXTERIOR
FFD FLOOR DRAINFDTN FOUNDATIONFEB FIRE EXTINGUISHER & BRACKETFEC FIRE EXTINGUISHER & CABINETFF EL FINISH FLOOR ELEVATIONFIN FLR FINISH FLOORFIN FINISH(ED)FOC FACE OF CONCRETE, FACE OF CURBFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDFOW FACE OF WALLFRTW FIRE RETARDANT TREATED WOODFS FAR SIDE (FACE, LAYER)FT FOOTFTG FOOTINGFURG FURRING
GGA GAGEGALV GALVANIZEDGC GENERAL CONTRACTORGFCI GROUND FAULT CIRCUIT INTERRUPTERGOVT GOVERNMENTGYP BD GYPSUM BOARDGYP GYPSUM
HHDBD HARDBOARDHDWD HARDW OODHDW HARDW AREHEX HEXAGON(AL)HM HOLLOW METALHORIZ HORIZONTALHP HEAT PUMPHS HIGH STRENGTHHT HEIGHTHVAC HEATING VENTILATION AND AIR CONDITIONING
II MOMENT OF INERTIAIBC INTERNATIONAL BUILDING CODEID INSIDE DIAMETERIF INSIDE FACEINCL INCLUDE(D)(ING)(SIVE)INS INSULATIONINT INTERIORINV INVERT(ED)
JJAN JANITOR
KNOT USED
Ll LITERL ANGLELB POUNDLH LEFT HANDLL LIVE LOADLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLT LIGHTLT WT LIGHT WEIGHT
MMAU MAKE UP AIR UNIT(S)m METER(S)MATL MATERIALMAX MAXIMUMMB MACHINE BOLTMCJ MASONRY CONTROL JOINTMECH MECHANIC(AL)MFG MANUFACTURINGMFR MANUFACTURERMIL STD MILITARY STANDARDMIN MINIMUMMISC MISCELLANEOUSmm MILLIMETERMO MASONRY OPENINGMOD MODIFYMT METAL THRESHOLDMTL METALMLWK MILLWORK
NN NORTHNA NOT APPLICABLENAT NATURALNBS NATIONAL BUREAU OF STANDARDSNFPA NATIONAL FIRE PROTECTION ASSOCIATIONNIC NOT IN CONTRACTNOM NOMINALNRC NOISE REDUCTION COEFFICIENTNS NEAR SIDE (FACE)NTS NOT TO SCALE
OOC ON CENTEROD OUTSIDE DIAMETEROF OUTSIDE FACEOFD OVERFLOW DRAINOF/CI OW NER FURNISHED/CONTRACTOR INSTALLEDOF/OI OW NER FURNISHED/OW NER INSTALLEDOH DR OVERHEAD DOOROPNG OPENINGOPH OPPOSITE HANDOSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATIONOz OUNCE
PPAR PARALLELPCA PORTLAND CEMENT ASSOCIATIONPCF POUNDS PER CUBIC FOOTPCI PRESTRESSED CONCRETE INSTITUTEPERF PERFORATE(D)PERP PERPENDICULARPL PROPERTY LINEPLAM PLASTIC LAMINATEPLF POUNDS PER LINEAL FOOTPR PAIRPREFAB PREFABRICATEPREFIN PREFINISHPRELIM PRELIMINARYPROJ PROJECTPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPBD PARTICLE BOARDPTD PAPER TOWEL DISPENSERPTDWR PAPER TOWEL DISPENSER & WASTER RECEPTACLEPVC POLYVINYL CHLORIDEPLWD PLYWOODPVG PAVING
QQC QUALITY CONTROLQTY QUANTITY
RR RADIUSRCP REFLECTED CEILING PLANRD ROOF DRAINREF REFERENCEREFL REFLECTREINF REINFORCEREQD REQUIREDREV REVISIONRH RIGHT HAND(ED)RO ROUGH OPENINGROW RIGHT OF WAYRTU ROOF TOP UNIT
SS SOUTHSBCCI SOUTHERN BUILDING CODE CONGRESS INTERNATIONALSCHED SCHEDULESD SOAP DISPENSERSDI STEEL DOOR INSTITUTESECT SECTIONSHT SHEETSIM SIMILARSJI STEEL JOIST INSTITUTESPEC SPECIFICATIONSP SOLID PLASTICSST STAINLESS STEELSTD STANDARDSTL STEELSTRUCT STRUCTURALSUSP SUSPENDEDSYMM SYMMETRICAL
TTRD TREADTAN TANGENTTEMP TEMPORARYTFF TOP OF FINISH FLOORTHK THICKNESSTLT TOILETTMH TOP OF MANHOLETOB TOP OF BEAMTOC TOP OF CURBTOF TOP OF FOOTINGTOG TOP OF GRADETOJ TOP OF JOISTTOL TOLERANCETOM TOP OF MASONRYTOS TOP OF STEELTOW TOP OF WALLTTD TOILET TISSUE DISPENSERTRANS TRANSPARENTTRTD TREATEDTS TUBE STEELTYP TYPICALT&G TONGUE AND GROOVE
UUBC UNIFORM BUILDING CODEUL UNDERWRITERS LABORATORIES, INCULT ULTIMATEUNO UNLESS NOTED OTHERWISEUON UNLESS OTHERWISE NOTED
VVAR VARIESVERT VERTICAL
WW WESTWLD WELDEDWP WORK POINTWWF WELDED W IRE FABRICW/ WITHW/O WITHOUTW/W WALL TO WALL
XXFMR TRANSFORMER
YNOT USED
ZNOT USED
DATUM ELEVATION (NEW)
BREAK LINE
GENERAL DRAW ING LEGEND
CENTER LINE
MATCH/DIVIDE LINE
ROOM NAME ROOM NUMBER
FURNISHINGS/EQUIPMENT
KEY NOTE
KEY DEMOLITION NOTE
REVISION
STRUCTURAL COLUMN LINE
DATUM ELEVATION (EXISTING)
ELEVATION MARK
SECTION MARK
PLAN DETAIL MARK
NEW DOOR
EXISTING DOOR
PLAN NORTH ARROW
TRUE NORTH
PLAN NORTH
NOT IN SCOPE
DRAWING TITLE
SHEET NUMBER WHERE REFERENCED
1/8" = 1'-0"
TITLEA1
0
ROOM NAME
0000
/
XX/XXXX
XX/XXXX
#
00
00
10 XX/XXXX
REFERENCE NUMBER
XX
XXXX
#
SHEET IDENTIFICATION FORMAT
AANNN
SHEET TYPE DESIGNATORS0 GENERAL (COVER SHEETS, INDEX, SYMBOLS LEGEND, NOTES, ETC.)1 PLANS (HORIZONTAL VIEWS)2 ELEVATIONS (VERTICAL VIEW S)3 SECTIONS (SECTIONAL VIEWS)4 LARGE SCALE VIEWS (ENLARGED PLANS, ELEVATIONS, OR SECTIONS THAT
ARE NOT DETAILS)5 DETAILS6 SCHEDULES AND DIAGRAMS7 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES)8 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES)9 3D REPRESENTATIONS (ISOMETRICS, PERSPECTIVES, PHOTOGRAPHS)
DISCIPLINEDESIGNATOR
SHEET TYPEDESIGNATOR(SEE BELOW)
SHEET SEQUENCENUMBER
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:1
4 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-011
Symbols,Legends &Abbreviations
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:1
6 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-021
AccessibilityStandards
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
CL
CL CL CL CL CL CL
CL CL
CL
CL
ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON
THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS).
ACCESSIBILITY GUIDELINE SHEETS ARE FOR
INFORMATIONAL PURPOSES ONLY. AND INTENDED
TO SERVE AS A GUIDE FOR CONSTRUCTION
PROFESSIONALS AND OWNERS.
SOME OF THE INFORMATION AND PICTOGRAPHS
SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO PLUMBING SHEETS FOR PLUMBING
FIXTURE MOUNTING HEIGHTS.
GRAPHICS SHOWN ARE FOR ADULTS.
ROOM100
SHOWERS
STANDARD ACCESSIBLE MOUNTING HEIGHTS
TUBS
TYPICAL TOILET STALLS
EWC/DRINKING FOUNTAINS
TYPICAL WATER CLOSETS
CHANGES IN LEVEL
URINALS
GENERAL NOTES
LAVATORIES
36
36
36 M
IN
48 MIN 60 MIN
30 M
IN3
0 M
IN
36 MIN
60 MIN60 MIN
30 M
IN3
0 M
IN
6 M
AX
6 MAX6 MAX
6 M
AX
6 MAX 6 MAX
6 M
AX
6 M
AX
6 MAX
38 M
IN
48 M
AX
15 MAX
48 M
AX
27 MAX
48 M
AX
17-1
9
48 M
AX
27 MAX
36
48
48
36 M
AX
9
60 M
AX
15 M
IN
80-9
6
48 M
AX
2 FROM
DOOR FRAME
48 M
AX
48 M
AX
6
36 M
AX
28-3
4
38 M
AX
2 M
AX
15-3
6
48 M
IN
30 M
IN
30 M
IN
12 MIN
CO
NT
RO
LE
ND
WA
LL
24 M
IN
12 MAX 24 MAX24 MIN
12 M
IN
24 M
IN
12 MAX 15 MAX
12 MAX 15 MAX12 MAX 24 MAX24 MIN
8-1
0
17-1
9
8-1
0
17-1
933-3
6
24 MIN
56 M
IN
59 M
IN
60 MIN60 MIN
4 MAX4
2 M
IN
6 M
IN
6 MIN
42 M
IN
60 M
IN
35-37
17-19 16-18 16-18 16-18 16-18
60 MIN
16-18
56 M
IN
5 M
AX
15 M
IN 15 MIN
17 MIN15 MIN
36
MINIF X>24
X
36 MIN
36 MIN
33-3
6
12
MIN
24 MIN
CL
36 MAX
12
MAX
54 MIN
42 MIN
33-3
6
TO
P O
F G
RIP
PIN
GS
UR
FA
CE
7-9
48 M
AX
15 M
IN
15
MIN
30
MIN
X36
MINIF X>24
15
MIN
36
MINIF X>24
X
30
IF X ≤ 24
X
15
MIN
15
MIN
CO
NT
RO
L
WA
LL
BACK
SE
AT
WA
LL
SE
AT
TRANSFER SHOWER ROLL-IN SHOWER ROLL-IN SHOWER
W/ SEAT ROLL-IN SHOWER
W/ SEAT
ALTERNATE
BACKWALL
CONTROL WALL
WITHOUT SEAT
CONTROL WALL
WITH SEAT
SHOWER SEAT
WALL
CL
NOTE: REFER TO "CHANGES IN LEVEL" DETAILS FOR SHOWER THRESHOLDS
THRESHOLD
SEAT
SEATTHRESHOLD THRESHOLD
BRACKET MOUNTED
FIRE EXTINGUISHER* CHALKBOARD MOUNTING
* MARKERBOARD MOUNTING
FIRE ALARM
AUDIBLE &
ACCESSIBLE
COAT HOOKS
VISUAL SIGNAL
OUTLET
* TACKBOARD MOUNTING
CABINET
FIRE EXTINGUISHER
TOWELS
MISC MOUNTING (DIMENSIONS SHOWN ARE TO THE HIGHEST OPERABLE PART)
TELEPHONE
THERMOSTAT
TOWELS
SWITCH
OUTLET
CUPS
SOAP
TO
P O
F E
XT
ING
UIS
HE
RIN
SID
E O
F C
AB
INE
T
TO
P O
F T
RA
Y
FIN CLGIF CEILING IS BELOW 90"
MOUNT TOP OF SIGNAL DEVICE
6" BELOW FINISHED CEILING
NOTE:
WASHING MACHINE
TOP LOAD
CONVEYOR
GROCERY
SLIDE
TRAYACCESSIBLE
COAT HOOKS
FRONT LOAD
BACK WALLBACK WALL
LENGTH
REMOVABLE SEAT CONTROLS LOCATION FIXED SEAT
REMOVABLE SEAT FIXED SEAT
OF TUB
CO
NT
RO
L E
ND
WA
LL
HE
AD
EN
D W
ALL
LENGTH
OF TUB
CL
HE
AD
EN
D
(REQUIRED) (REQUIRED)
WA
LL
AMBULATORY ACCESSIBLE TOE CLEARANCE SIDE APPROACH WALL HUNG WATER CLOSET FLOOR MTD WATER CLOSET CLEARANCE AT WATER CLOSET
LAVATORY, URINALOR TOILET ACCESSORIES
NOT IN A STALL
NOT ASSOCIATEDWITH A WATER CLOSET
ONLY TOILET
ASSOCIATED WITHWATER CLOSETS AREALLOWED WITHINFLOOR AREA
ACCESSORIES
WA
LL/P
OS
T M
TD
CA
NT
ILE
VE
RE
D
UN
IT
FORWARD APPROACH
ACCESSIBLE UNIT
DOWN TO 27" AFF MIN
APRON THAT EXTENDS
HIGH UNIT SHOULD HAVECL
EQUIPMENT PERMITTED
IN OUTLINED AREA
CL
CL
REFER TO KNEE AND
TOE CLEARANCE GRAPHICS
NOTE:
WIDE SIDE
LEVER ON
250 LBS AND BE CONTINUOUS
GRAB BARS MUST SUPPORT
DISPENSERS
IF A WALL HUNG OR FLOOR
MOUNTED FLUSH VALVE
WATER CLOSET IS SPECIFIED,
ENSURE ALL DIMENSIONS
SHOWN ARE MET.
CL CL
1/4
1
2
1/2
BEVELED TRANSITION
VERTICAL TRANSITION
12
1/4
VERTICAL/BEVELED
1/4
TRANSITION
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:1
8 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-022
AccessibilityStandards
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
CHILDREN'S MOUNTING
HEIGHTS & REACH RANGES
REACH RANGES
RAMPS AND STAIRS
WATER CLOSETS
READING AND STUDY AREAS, AND
FIXED OR BUILT-IN SEATING AND TABLES,
WORK STATIONS
ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON
THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS).
ACCESSIBILITY GUIDELINE SHEETS ARE FOR
INFORMATIONAL PURPOSES ONLY. AND INTENDED
TO SERVE AS A GUIDE FOR CONSTRUCTION
PROFESSIONALS AND OWNERS.
SOME OF THE INFORMATION AND PICTOGRAPHS
SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO PLUMBING SHEETS FOR PLUMBING
FIXTURE MOUNTING HEIGHTS.
GRAPHICS SHOWN ARE FOR ADULTS.
PROTRUDING OBJECT PROTECTION/REACH RANGES
GENERAL NOTES
EXAMPLE SIGNAGE - SEE STANDARD ACCESSIBLE MOUNTING HEIGHT
TYPICAL DOOR CLEARANCES
ASSEMBLY SEATING
48 M
IN
18 MIN
60 M
IN
X
X
Y
Y
42 M
IN
22 MIN
32 MINCLEAR
60 M
IN
18 MIN
X>
8
48 M
IN
12 MIN
X>
8
48 M
IN
4 MAX
X ≥
80
X >
27
X <
80"
27"
MA
X
48 M
AX
15
MIN
20MAX
48 M
AX
44 M
AX
2O-25MAX
10 MAX
48 M
AX
15
MIN
34 M
AX
10 MAX
48 M
AX
34 M
AX
>10-24MAX
46 M
AX
ANY AMOUNT
X ≥
80
X <
27
6 M
IN
6 M
IN
6 M
IN
6 M
IN
6 M
IN
6 M
IN
48 M
IN
60 M
AX
60 M
AX
48 M
IN
6 M
IN
60 M
AX
48 M
IN
60 M
AX
48 M
IN
Y
42 M
INY
48 M
IN
24 MIN 24 MIN
48 MIN
48 M
IN
43 M
AX
OR
66 M
IN
34-4
8
MA
X
48 M
IN
33 MIN 33 MIN
60 M
IN
33 MIN 33 MIN
30 M
IN
24 M
IN
36
TO
SH
OU
LD
ER
36
TO
SH
OU
LD
ER
PUSH SIDE
NOTE:
PULL SIDE
FRONT APPROACHES SWINGING DOORS
HAS BOTH A CLOSER AND A LATCH
X = 12" MIN (305mm) IF DOOR
PUSH SIDE
NOTE:
PULL SIDE
NOTE: X = 36" MIN IF Y = 60";
X = 42" MIN IF Y = 54"
HINGE SIDE APPROACHES SWINGING DOORS
Y = 48" MIN (1220mm) IF DOOR
HAS BOTH A CLOSER AND A LATCH
RECESSED DOOR
CLOSER & LATCH PROVIDED
PROTRUDING
OBJECT
UNDER STAIRS
FORWARD REACH RANGES SIDE REACH RANGES
PROTRUDING
OBJECT
LETTERS & BRAILLE
GRAPHIC SYMBOLS
6x8 PICTOGRAM
MEN
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
WOMEN
& BRAILLE
ROOM NUMBER
8x6 ROOM NAME
129SUPERVISOR
MAINTENANCE
& BRAILLE
10x3 ROOM NAME
ADMINISTRATION
6x6 DIRECTIONAL
GRAPHIC SYMBOL
ONLY ONLY
GRAPHIC SYMBOL
6x6 DIRECTIONAL
& BRAILLE
6x6 CHANGEABLE
MESSAGE W/ PERMANENT
ROOM NAME, NUMBER,
ITHJOHN S
OFFICE
169
REFER TO SIGNAGE PACKAGE OR DETAILS FOR ACTUAL SIGNAGE SPECIFIED
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
STAIR 1
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
STAIR 1
14-1720-25
18
40
LOW
HIGH
TOP OF HANDRAIL GRIPPING SURFACE
GRAB BARSDISPENSER HEIGHT
36
20
28 MAX
18-2014
KNEE CLEARANCE
HEIGHT OF TABLES OR COUNTERS
24 MIN
26-30 MAX
AGES: 3 AND 4 AGES: 5 THROUGH 8
17-1925-27
16
44
AGES: 9 THROUGH 12
WATER CLOSET CENTERLINE 12-1512 15-18
APPROACH ALLOWED
PARALLEL
AGES: 5 & YOUNGER AGES: 6-12
28 MAX 28 MAX
PUSH SIDE
NOTE:
A CLOSER
PULL SIDE
A CLOSER
Y = 54" MIN (1370mm) IF DOOR HAS
LATCH SIDE APPROACHES SWINGING DOORS
Y = 48" MIN IF DOOR HASNOTE:
VESTIBULE DOORS
TWO HINGED DOORS IN SERIES
NOTE:
THE CLEARANCES FOR FRONT APPROACHES
ALL DOORS IN ALCOVES SHALL COMPLY WITH
VESTIBULE DOORS DOOR HARDWARE DOOR LITE
BENCH SEATINGTHEATER SEATING
BENCH SEATINGTHEATER SEATING
LINE OF SIGHT
LINE OF SIGHT
SPORTS ARENA
THEATER/PLAYHOUSE
AUDITORIUM/CONCERT HALL
LECTURE HALLS
MEETING ROOMS
LINE OF SIGHT OVER HEADS
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:2
0 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-023
AccessibilityStandards
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
PUSH FOR HELP
EMERGENCY
PHONE
18
3
1
4
2
7
5
8
6
1
3
2
4
5
7
6
8
8 1
1 2
1«
1« 2
1« 2
43
5 6
7 8
ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON
THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS).
ACCESSIBILITY GUIDELINE SHEETS ARE FOR
INFORMATIONAL PURPOSES ONLY. AND INTENDED
TO SERVE AS A GUIDE FOR CONSTRUCTION
PROFESSIONALS AND OWNERS.
SOME OF THE INFORMATION AND PICTOGRAPHS
SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO PLUMBING SHEETS FOR PLUMBING
FIXTURE MOUNTING HEIGHTS.
GRAPHICS SHOWN ARE FOR ADULTS.
CLEAR FLOOR AREA/ACCESSIBLE ROUTE
ELEVATORS LULA LIFTS
ACCESSIBLE RAMP
GENERAL NOTES
ELEVATORS
«
FORWARD PARALLEL ELEVATIONTOE CLEARANCE
PLANCENTERED
ELEVATIONKNEE CLEARANCE
ALCOVE
FORWARD
ALCOVE
PARALLEL
180 DEG
TURN AROUND
NARROW
PASSAGE
SINGLEWHEELCHAIR
T-SHAPE
TURN AROUND
CIRCLE
TURN AROUND
IF Y=60 MIN, X=36 MIN
OFF-CENTERED DOOR
PLATFORM
LIF
T M
EC
HA
NIS
M
(NEW CONSTRUCTION)CENTERED DOOR
DIRECTION
HANDRAILS
LANDING
RAMPLANDING
EDGE PROTECTION CURB/BARRIER OR 12" EXTENDED
HANDRAILS REQUIRED ON BOTH SIDES OF RAMP
RAMP WIDTH TO BE NO LESS THAN 36" BETWEEN
RAMP CROSS SLOPE NOT TO EXCEED 2% MAX
LANDING SLOPE NOT TO EXCEED 2% IN ANY
SURFACE REQUIRED ON BOTH SIDES OF
RAMP RUN LANDINGLANDING
LANDING
RAMP RUN
RAMP RUN
EXTENDED
SURFACE
CURB OR
BARRIER
SECTION
CHANGE IN DIRECTION
SLOPED SURFACE WHERE VERT EDGE IS > 8"
AT
LE
AS
T A
S
WID
E A
S T
HE
WID
ES
T R
AM
P R
UN
STRAIGHT
OR
RAISED OR FLUSH
ENTRY LEVEL
DOOR OPEN
ALARM
DOOR CLOSE
EMERGENCY
CAR FLOOR
HE
IGH
T W
ITH
IN
RE
AC
H R
AN
GE
DOOR SAFETY BEAMS HALL LANTERNS HALL CONTROLS
INSIDE CABFLOOR DESIGNATION
BESIDE DOOR ABOVE DOOR EMERGENCY
COMMUNICATION
DEVICEOUTSIDE CAB CAR CONTROL DETAILS
MAIN
STOP
DOOR FRAME
(ABOVE CAR CONTROL PANEL)
60" MIN
60 M
IN
30
MIN
24
MIN
12MIN
30MIN
12MIN
60 MIN
48 MIN
30
MIN 48 M
IN
30 MIN
30 M
IN
48 MIN
36 MIN
X >
24
60 MIN
X >
15
30 M
IN
6 MAX17-25
8 MIN
9"
MIN
11 MIN
27 M
IN
24MAX 48 MIN
24MAX
32 M
IN
36 M
IN
32 M
IN
36 M
IN
Y4
8 M
IN
X42 MIN
X42 MIN
X<48
9"
MIN
42 MIN
54 M
IN
32 MIN
32 MIN
42 M
IN
60 MIN
36 MIN
60 M
IN
80 MIN
51 M
IN
54 M
IN
42 MIN
80 M
IN
36 MIN 36 MIN
54 M
IN
51 M
IN
68 MIN
54 MIN
51 M
IN
36 MIN
51 MIN
60 MINSLOPE 1:12 MAX60 MIN
60 MIN 60 MIN 60 MIN
60 M
IN
36 MINBETWEEN
HANDRAILS
36 M
INB
ET
WE
EN
HA
ND
RA
ILS
12 MIN12 MIN
X<
4
27 M
AX
34-3
8
34-3
8
36 MIN
TOP & BOTTOMOF RAMP
12 MIN
48 M
AX
72
29
5
48 M
AX
60
2
35 M
IN
3/4 MIN
2 1
/2 M
IN
2 1
/2 M
IN
CL
CL
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:2
2 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-024
AccessibilityStandards
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
R 4
R16
SYMBOL & BORDER: WHITEBACKGROUND: BLUESYMBOL: BLUE OR WHITE
ACCESSIBLE PARKING SIGNAGE PARKING SPACESPASSENGER LOADING ZONE
ACCESSIBLE ROUTE FROM PARKINGACCESSIBLE ROUTES
BUS STOPS ACCESSIBILITY SYMBOL
· ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON
THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS).
· ACCESSIBILITY GUIDELINE SHEETS ARE FOR
INFORMATIONAL PURPOSES ONLY. AND INTENDED
TO SERVE AS A GUIDE FOR CONSTRUCTION
PROFESSIONALS AND OWNERS.
· SOME OF THE INFORMATION AND PICTOGRAPHS
SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.
· REFER TO PLUMBING SHEETS FOR PLUMBING
FIXTURE MOUNTING HEIGHTS.
· GRAPHICS SHOWN ARE FOR ADULTS.
VAN ACCESSIBLE
PARKINGRESERVED
PARKINGRESERVED
VIOLATORS
SUBJECT TO
FINE AND
TOWING
CURB RAMPS AT MARKED CROSSINGSCURB RAMPS
GENERAL NOTES
PROTRUDING OBJECTS/TELEPHONES ACCESSIBLE SEATING
36 MIN
48 M
IN
36 MIN
X
48M
IN
X
X
48
MIN
36
MIN
4M
AX
4MAX
4MAX
36MIN
1:1
2 S
LO
PE
MA
X
24
MIN
80 M
INX>12
X>12
27 M
AX
12MAX
27
-80 12 MAX
12 MAX
27
-80
30 MIN
48
MIN
2 1/2MAX
18
MIN
5'-0
"M
IN
FULL LENGTH OFVEHICLE PULL-UP SPACE
20'-0" MIN
60 M
IN
36 M
IN
48
30
36
36
36
MIN
36
MIN
36
MIN
8'-0
"M
IN
12
MAX
12
MAX96 MIN(8'-0")
60 MIN(5'-0")
132 MIN(11'-0")
36
MIN
36MIN
2 1/2
24
2 1
/2 3
16 13 1/4
44
2
5
4
2 3/4
5 1/2
51/2
41 3/4
4
201 1
12
24MIN
24MIN
CURB RAMP WITHIN
MARKED CROSSINGSTRAIGHT
SEGMENT
WITHIN
CROSS WALK
CURB RAMP WITHIN
MARKED CROSSING
CURB RAMP
MARKED
CROSSING
CURB RAMP
MARKED
CROSSING
1:12 MAX IF
X IS < 36
STRAIGHT
SEGMENT WITHIN
CROSS WALK
ISLAND CUT THROUGH
LEVEL WITH STREET
WELL DEFINED
EDGE
NON-WALKING
SURFACE
NON-WALKING
SURFACE
ISLAND CUT THROUGH
LEVEL WITH STREET
2.35
2.3
5
0.9
0.2
DETECTABLE WARNING
DEVICES SHALL COMPLY
WITH THE TEXAS
ACCESSIBILITY STANDARDS
AND BE ALIGNED IN THE
DIRECTION OF
PEDESTRIAN TRAVEL
THE SURFACE OF THE
DETECTABLE WARNING
DEVICES SHALL BE A
CONTRASTING COLOR
THAT PROVIDES A LIGHT
REFLECTIVE VALUE
SIGNIFICANTLY
CONTRASTING WITH THE
ADJACENT SURFACES
FLARED SIDES
24
MIN
1:10
MAX
SLOPE
EACH SIDE
BOTTOM OF RAMP SURFACE
DETAIL
FLARED SIDES
1:12 MAX IF
X IS < 36"
ENLARGED PLAN
ENLARGED PLAN
ENLARGED PLAN
ENLARGED PLAN
CURB RAMP AND ADJOINING SURFACE SLOPES
(D)(C)
(B)(A)
WITHIN CURB RAMP AND FLARES, THERE SHALL BE NO LIGHT OR SIGNAL
POLES, SIGNAL BOXES, VALVE BOX COVERS, OR THE LIKE
ISLAND
ISLAND
FLARED SIDES
1:12 MAX IF
X IS < 36"
ISLAND
CUT THROUGH AT ISLAND CURB RAMP AT ISLAND
CURB RAMP
MAX SLOPE
ADJOINING
SURFACE
MAX SLOPE
17
-19
20-24
42 M
IN2 M
AX
10 M
AX
20 M
AX
ACCESSIBLE PATH
OF TRAVEL
TELEPHONES
OVERHANG
POST
FORWARD
APPROACH
PROTRUDING OBJECTS
PARALLEL
APPROACH
PLAN
OVERHANG
SIGNS
OVERHANG
POST
DOMINANT DIRECTION
OF TRAVELLONG DIRECTION
PERPENDICULAR TO
DOMINANT DIRECTION
OF TRAVEL
1/2 MAX GRATING
60 MIN
96 M
IN
CURB OR
ROADWAY
EDGEBUS
STOP
PAD
SHELTER
ACCESSIBLE
ROUTE
PERPENDICULAR SIDEWALK PARALLEL SIDEWALKW/ IN-LINE CURB RAMP W/ PARALLEL CURB RAMP
PERPENDICULAR SIDEWALKW/ FLARED CURB RAMP
NON-WALKING
SURFACE
NON-WALKING
SURFACE
PERPENDICULAR SIDEWALKW/ LONGITUDINAL CURB RAMP
NON-WALKING
SURFACE
NON-WALKING SURFACE
CAR
PASSINGACCESSIBLE PATH WIDTH
SINGLE
60 MIN
96 M
IN
CURB OR
ROADWAY
EDGEBUS
STOP
PAD
ACCESSIBLE
ROUTE
CURB RAMP
CURB RAMP CONFIGURATION MAY VARY
36
MIN
36
MIN36M
IN
36MIN
60 MIN60 MIN
2% MAX SLOPE
VAN
PARKING SPACES AND ACCESS AISLESLOPE NOT TO EXCEED 2% IN ANY DIRECTION
12" HIGH LETTERS WITH
A 2" STROKE WIDTH
ABOVE GRADE
60 MIN
ABOVE GRADE
48 MIN
ACCESSIBLE ROUTE
OF ACCESSIBILITY PAINTED
IN EACH PARKING STALL
INTERNATIONAL SYMBOLABOVE GRADE
80 MAX
AS REQUIRED
VAN ACCESSIBLE
NO PARKING
NO
PARKING
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN
DN
DN
EGRESS EXIT REQUIRED
EGRESS PATH AND TRAVEL DISTANCE
1/2 HOUR FIRE [WALL][PARTITION][BARRIER]
1 HOUR FIRE [WALL][PARTITION][BARRIER]
SMOKE [WALL][PARTITION][BARRIER]
1 HOUR FIRE SMOKE [WALL][PARTITION][BARRIER]
EXIT
EW=36"
GSF
NSF
FEC
TD
CPOT
(M)DBE
OL
200'
ASSEM 2080
15 NET 139
.2 27.8" 140"
FUNCTION OF SPACE (TABLE 1004.1.2)
TOTAL FLOOR AREA (SF)
CALCULATED OCCUPANT LOAD OF SPACE
EGRESS WIDTH PROVIDED (INCHES)
MINIMUM EGRESS WIDTH REQUIRED (INCHES)
EGRESS WIDTH FACTOR (SECTION 1005.3.1 FOR STAIRS; 1005.3.2 FOR OTHERS)
FLOOR AREA (SF) PER OCCUPANT (TABLE 1004.1.2)
200'
459 0.2
32" 36"
TOTAL OCCUPANT LOAD PER EXIT
EGRESS WIDTH FACTOR (SECTION 1005.3.1 FOR STAIRS; 1005.3.2 FOR OTHERS)
EGRESS WIDTH PROVIDED (INCHES)
MINIMUM EGRESS WIDTH REQUIRED (INCHES)
LEGEND
DISTANCE BETWEEN EXITS
EXIT WIDTH PROVIDED AT SPECIFIC EXIT
GROSS SQUARE FOOT
NET SQUARE FOOT
FIRE EXTINGUISHER CABINET
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
(MINIMUM) DISTANCE BETWEEN EXITS
OCCUPANT LOAD
GENERAL CONSTRUCTION INFORMATION
BUILDING
PLUMBING
MECHANICAL
ELECTRICAL
FIRE
ACCESSIBILITY
IBC 2012
2012 TAS, 2010 ADA/SAD
ENERGY
OTHER -
OCCUPANT LOAD (TAB 1004.5)
EGRESS
PLUMBING FIXTURE RQMTS - IPC
DESCRIPTION:OCC:
LAV DRINK
FOUNT.REF.
IPC 410
SE
RV
ICE
SIN
K
M F
UR
INA
LS
WATER
CLOSET
M FOC
CU
PA
NT
LO
AD
(A
CT
UA
L)
US
E G
RO
UP
ASSEM
TOTAL REQUIRED
TOTAL PROVIDED
A-3 129
1
2
1
2
1
1
1
2
1
2
1 1
11
OTHER
PLUMBING FIXTURE RQMTS - IPC
TOILETS
LAVATORIES
TOILETS
LAVATORIES
DRINKING FOUNTAIN (ADA HI/LO)
SERVICE SINK
REQUIRED PROVIDED
REQUIRED PROVIDED
REQUIRED PROVIDED
1
1
2+
2+
1
1
2+
2+
1
1
1
1
FIXTURE COUNT FEMALE A-2 (103) TABLE 403.1
FIXTURE COUNT MALE A-2 (103) TABLE 403.1
FIXTURE COUNT DRINKING FOUNTAIN & SERVICE SINK TABLE 403.1
COMMUNITY HALL
IECC 2012
ABILENE FIRE CODE 2009
NEC 2014
IMC 2012
IPC 2012
ASSEMBLY1,938 SF @ 15 SF PER PERSON
BUSINESSX,XXX SF @ 100 SF PER PERSON
STORAGE/MECHANICALX,XXX SF @ 300 SF PER PERSON
TOTAL
129
-
-
129
# OF PEOPLEOCCUPANT LOAD
ACCESSORY STORAGE AREAS, MECHANICAL, EQUIPMENT ROOM
300 GROSS
300 GROSS
500 GROSS
AIRPORT TERMINAL
BAGGAGE CLAIM 20 GROSS
BAGGAGE HANDLING 300 GROSS
CONCOURSE 100 GROSS
WAITING AREAS 15 GROSS
ASSEMBLY
GAMING FLOORS (KENO, SLOTS, ETC.) 11 GROSS
ASSEMBLY W/ FIXED SEATS SEE SECTION 1004.6
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED (CHAIRS ONLY-NOT FIXED) 7 NET
STANDING SPACE 5 NET
UNCONCENTRATED (TABLES AND CHAIRS) 15 NET
7 NET
BUSINESS AREAS 150 GROSS
COURT ROOMS-OTHER THAN FIXED SEATING AREAS 40 NET
DAY CARE 35 NET
DORMITORIES 50 GROSS
EDUCATIONAL
CLASSROOM AREA 20 NET
SHOPS AND OTHER VOCATIONAL ROOM AREAS 50 NET
EXERCISE ROOMS 50 GROSS
H-5 FABRICATION AND MANUFACTURING AREAS 200 GROSS
INDUSTRIAL AREAS 100 GROSS
INSTITUTIONAL AREAS
INPATIENT TREATMENT AREAS 240 GROSS
OUTPATIENT AREAS 100 GROSS
SLEEPING AREAS 120 GROSS
KITCHENS, COMMERCIAL 200 GROSS
LIBRARY
READING ROOM 50 NET
STACK AREA 100 GROSS
LOCKER ROOMS 50 GROSS
MERCANTILE
AREAS ON OTHER FLOORS 60 GROSS
STORAGE, STOCK, SHIPPING AREAS 300 GROSS
PARKING GARAGES 200 GROSS
RESIDENTIAL 200 GROSS
SKATING RINKS, SWIMMING POOLS
RINK AND POOL 50 GROSS
DECKS 15 GROSS
STAGES AND PLATFORMS 15 NET
WAREHOUSES 500 GROSS
BOWLING CENTERS, ALLOW 5 PERSONS FOR EACH LANE INCLUDING 15 FEET OF RUNWAY, AND FOR ADDITIONAL AREAS
APPLICABLE CODES:
FUNCTION OF SPACE OCCUPANT PER SF
TOTAL OCCUPANT LOAD FOR THE AREA
TOTAL OCCUPANT LOAD EGRESS WILL ACCOMMODATE 680 PEOPLE
EGRESS WIDTH REQUIRED
129 X 0.2 26 INCHES
EGRESS PROVIDED
MAXIMUM ALLOWABLE TRAVEL DISTANCE(TABLE 1017.2)
LONGEST TRAVEL DISTANCE
MAXIMUM DEAD END LIMIT (SECTION 1020.4)
250 FEET (SPRINKLED)
MAXIMUM DEAD END LIMIT PROVIDED
N/A
MAXIMUM COMMON PATH OF EGRESS TRAVEL (TABLE 1006.2.1)
COMMON PATH OF EGRESS TRAVEL PROVIDED
N/A
TW O EXITS REQUIRED WHERE DESIGN OCCUPANT LOAD EXCEEDS VALUES LISTED (TABLE 1006.2.1)
N/A
MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD (TABLE 1006.3.2)
1-500 2 EXITS
501-1000 3 EXITS
MORE THAN 1000 4 EXITS
129 PEOPLE
136 INCHES
N/A
55 FEET (SPRINKLED)
(SECTION 1005.3.1 FOR STAIRS; 1005.3.2 FOR OTHERS)
CONCENTRATED BUSINESS USE AREA SEE SECTION 1004.8
MALL BUILDINGS - COVERED AND OPEN SEE SECTION 402.8.2
EXHIBIT GALLERY AND MUSEUM 30 NET
AIRCRAFT HANGARS
AGRICULTURAL BUILDING
1,938 SF129
ASSEM15 SF
64"0.2 26"
CHAMBER
202
EXITEXIT10 .232" 68"
119 .232" 68"
IT
203
MD
BE -
64-0"'/
3 = 2
1'-4"
55'
# DATE DESCRIPTION
-
CLIENT
PROJECT NO.
Parkhill.com
9/1
6/2
021
2:3
6:2
6 P
M
1077.21
R_
v2
1
ISSUE FOR BID09/16/2021
555 Walnut St.Abilene, TX 79601
City of Abilene
G-101
Code Information
Ab
ile
ne
Cit
y C
ou
nc
il C
ha
mb
ers
Re
no
va
tio
ns
1. UL ASSEMBLIES INDICATED ESTABLISH BASIS PERFORMANCE. OTHER ASSEMBLIES MAY BE CONSIDERED AT DISCRETION OF ARCHITECT IF EQUIVALENT PERFORMANCE IS PROVIDED. SUBSTITUTION PROPOSALS SHALL INCLUDE CHANGES REQUIRED TO COMPONENTS OF ASSEMBLY.
2. FIRE EXTINGUISHERS, (IFC SECTION 906 AND NFPA 10; CHAPTER 6 AND TABLE 6.2.1.1, CLASS A - LIGHT HAZARD OCCUPANCY) MAXIMUM FLOOR AREA FOR UNIT - 11,250 SF; MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER - 75 FT.
GENERAL NOTES
1/8" = 1'-0"A1CODE PLAN
RE
GIS
T
ERED ARCH
ITE
CT
TS
A
ET
FOET
XA
S
14746
BI L
LP . NOON
AN