8843531 structural reviewer qa

196
It is a structural system without complete vertical local carrying space frame. (NSCP 208.20) Braced frame Bearing wall system Rigid component Concentric braced frame

Upload: armando-garce

Post on 07-Mar-2015

173 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: 8843531 Structural Reviewer QA

It is a structural system without complete vertical local carrying space frame. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Concentric braced frame

Page 2: 8843531 Structural Reviewer QA

It is a structural system without complete vertical local carrying space frame. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Concentric braced frame

Page 3: 8843531 Structural Reviewer QA

Is a component including its attachments having fundamental period less than or equal to 0.06 sec. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Flexible component

Page 4: 8843531 Structural Reviewer QA

Is a component including its attachments having fundamental period less than or equal to 0.06 sec. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Flexible component

Page 5: 8843531 Structural Reviewer QA

Is a component including its attachments having fundamental period greater than 0.60 sec. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Flexible component

Page 6: 8843531 Structural Reviewer QA

Is a component including its attachments having fundamental period greater than 0.60 sec. (NSCP 208.20)

Braced frame

Bearing wall system

Rigid component

Flexible component

Page 7: 8843531 Structural Reviewer QA

Concrete filled driven piles of uniform section shall have a nominal outside diameter of not less than (NSCP 307.7.3)

200 mm

250 mm

300 mm

350 mm

Page 8: 8843531 Structural Reviewer QA

Concrete filled driven piles of uniform section shall have a nominal outside diameter of not less than (NSCP 307.7.3)

200 mm

250 mm

300 mm

350 mm

Page 9: 8843531 Structural Reviewer QA

A complete record of test of materials and of concrete shall be available for inspection during the progress of work and _______

years after completion of the project and shall be preserved by the inspecting engineer or architect for that purpose, (NSCP 403.20)

2 years

5 years

10 years

15 years

Page 10: 8843531 Structural Reviewer QA

A complete record of test of materials and of concrete shall be available for inspection during the progress of work and _______

years after completion of the project and shall be preserved by the inspecting engineer or architect for that purpose, (NSCP 403.20)

2 years

5 years

10 years

15 years

Page 11: 8843531 Structural Reviewer QA

The minimum bend diameter for 10mm Ø through 25mm Ø bars (NSCP 407.30)

12 db

6 db

8 db

10 db

Page 12: 8843531 Structural Reviewer QA

The minimum bend diameter for 10mm Ø through 25mm Ø bars (NSCP 407.30)

12 db

6 db

8 db

10 db

Page 13: 8843531 Structural Reviewer QA

The minimum bend diameter for 28mm Ø through 36mm Ø bars (NSCP 407.30)

12 db

6 db

8 db

10 db

Page 14: 8843531 Structural Reviewer QA

The minimum bend diameter for 28mm Ø through 36mm Ø bars (NSCP 407.30)

12 db

6 db

8 db

10 db

Page 15: 8843531 Structural Reviewer QA

The minimum clear spacing between parallel bars in a layer must be db but not less than? (NSCP 407.7.3)

50mm

25mm

75mm

100mm

Page 16: 8843531 Structural Reviewer QA

The minimum clear spacing between parallel bars in a layer must be db but not less than? (NSCP 407.7.3)

50mm

25mm

75mm

100mm

Page 17: 8843531 Structural Reviewer QA

In spirally reinforced or tied reinforced compression members, clear distance between longitudinal bars shall not be less than?

(NSCP 407.7.3)

2.0 db

2.15 db

1.50 db

1.75 db

Page 18: 8843531 Structural Reviewer QA

In spirally reinforced or tied reinforced compression members, clear distance between longitudinal bars shall not be less than?

(NSCP 407.7.3)

2.0 db

2.15 db

1.50 db

1.75 db

Page 19: 8843531 Structural Reviewer QA

In walls and slabs other than concrete joist construction, primary flexural reinforcement shall not be spaced farther apart than 3 times wall or slab thickness nor farther than? (NSCP 407.7.5)

375mm

450mm

500mm

300mm

Page 20: 8843531 Structural Reviewer QA

In walls and slabs other than concrete joist construction, primary flexural reinforcement shall not be spaced farther apart than 3 times wall or slab thickness nor farther than? (NSCP 407.7.5)

375mm

450mm

500mm

300mm

Page 21: 8843531 Structural Reviewer QA

Groups of parallel reinforcing bars bundled in contact to act as one unit shall be united to ___ pieces in one bundle. (NSCP 407.7.6.1)

4

3

2

5

Page 22: 8843531 Structural Reviewer QA

Groups of parallel reinforcing bars bundled in contact to act as one unit shall be united to ___ pieces in one bundle. (NSCP 407.7.6.1)

4

3

2

5

Page 23: 8843531 Structural Reviewer QA

Bars larger than ___mm shall not be bundled in beams:

(NSCP 407.7.6.3)

25mm

16mm

28mm

36mm

Page 24: 8843531 Structural Reviewer QA

Bars larger than ___mm shall not be bundled in beams:

(NSCP 407.7.6.3)

25mm

16mm

28mm

36mm

Page 25: 8843531 Structural Reviewer QA

Individual bars within a bundle terminated within the span of flexural members shall terminate at different points with at least

____ stagger: (NSCP 407.7.6.4)

12 db

10 db

50 db

40 db

Page 26: 8843531 Structural Reviewer QA

Individual bars within a bundle terminated within the span of flexural members shall terminate at different points with at least

____ stagger: (NSCP 407.7.6.4)

12 db

10 db

50 db

40 db

Page 27: 8843531 Structural Reviewer QA

Minimum concrete cover cast against and permanently exposed to earth: (NSCP 407.8.1)

100 mm

75 mm

50 mm

150 mm

Page 28: 8843531 Structural Reviewer QA

Minimum concrete cover cast against and permanently exposed to earth: (NSCP 407.8.1)

100 mm

75 mm

50 mm

150 mm

Page 29: 8843531 Structural Reviewer QA

The minimum clear concrete covering for cast in place slab:

(NSCP 407.8.1)

20mm

25mm

40mm

50mm

Page 30: 8843531 Structural Reviewer QA

The minimum clear concrete covering for cast in place slab:

(NSCP 407.8.1)

20mm

25mm

40mm

50mm

Page 31: 8843531 Structural Reviewer QA

In ultimate strength design, the strength reduction factor Ø for flexure without axial loads: (NSCP 409.2.1)

0.85

0.75

0.90

0.70

Page 32: 8843531 Structural Reviewer QA

In ultimate strength design, the strength reduction factor Ø for flexure without axial loads: (NSCP 409.2.1)

0.85

0.75

0.90

0.70

Page 33: 8843531 Structural Reviewer QA

In ultimate strength design, the strength reduction factor Ø for shear and torsion: (NSCP 409.4.2.3)

0.70

0.75

0.85

0.90

Page 34: 8843531 Structural Reviewer QA

In ultimate strength design, the strength reduction factor Ø for shear and torsion: (NSCP 409.4.2.3)

0.70

0.75

0.85

0.90

Page 35: 8843531 Structural Reviewer QA

The minimum one way slab thickness which is simply supported at the ends only is: (NSCP 409.6.2)

L/20

L/24

L/28

L/10

Page 36: 8843531 Structural Reviewer QA

The minimum one way slab thickness which is simply supported at the ends only is: (NSCP 409.6.2)

L/20

L/24

L/28

L/10

Page 37: 8843531 Structural Reviewer QA

The minimum one way slab thickness for a ONE end continuous slab is: (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 38: 8843531 Structural Reviewer QA

The minimum one way slab thickness for a ONE end continuous slab is: (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 39: 8843531 Structural Reviewer QA

The minimum one way slab thickness for a BOTH ends continuous slab is: (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 40: 8843531 Structural Reviewer QA

The minimum one way slab thickness for a BOTH ends continuous slab is: (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 41: 8843531 Structural Reviewer QA

The minimum cantilevered slab thickness is : (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 42: 8843531 Structural Reviewer QA

The minimum cantilevered slab thickness is : (NSCP 409.6.2)

L/20

L/24

L/10

L/28

Page 43: 8843531 Structural Reviewer QA

Deep continuous flexural members has overall depth to clear span ratio greater than: (NSCP 410.8.10)

0.40

0.60

0.75

0.70

Page 44: 8843531 Structural Reviewer QA

Deep continuous flexural members has overall depth to clear span ratio greater than: (NSCP 410.8.10)

0.40

0.60

0.75

0.70

Page 45: 8843531 Structural Reviewer QA

Deep simple span flexural members has overall depth to clear span ratio greater than: (NSCP 307.4.2)

0.40

0.60

0.75

0.70

Page 46: 8843531 Structural Reviewer QA

Deep simple span flexural members has overall depth to clear span ratio greater than: (NSCP 307.4.2)

0.40

0.60

0.75

0.70

Page 47: 8843531 Structural Reviewer QA

Spacing of shear reinforcement placed perpendicular to axis of non-prestressed member shall not exceed: (NSCP 411.6.4.1)

d/2

d/4

¾ d

d/5

Page 48: 8843531 Structural Reviewer QA

Spacing of shear reinforcement placed perpendicular to axis of non-prestressed member shall not exceed: (NSCP 411.6.4.1)

d/2

d/4

¾ d

d/5

Page 49: 8843531 Structural Reviewer QA

Development length Ld for deformed bars in tension shall be less than: (NSCP 412.3.1)

300 mm

250 mm

200 mm

350 mm

Page 50: 8843531 Structural Reviewer QA

Development length Ld for deformed bars in tension shall be less than: (NSCP 412.3.1)

300 mm

250 mm

200 mm

350 mm

Page 51: 8843531 Structural Reviewer QA

Is an essentially vertical truss system of the concentric or eccentric type that is provided to resist lateral forces: (NCSP 208.1)

Building frame system

Braced frame

Diaphragm

Collector

Page 52: 8843531 Structural Reviewer QA

Is an essentially vertical truss system of the concentric or eccentric type that is provided to resist lateral forces: (NCSP 208.1)

Building frame system

Braced frame

Diaphragm

Collector

Page 53: 8843531 Structural Reviewer QA

Is a horizontal or nearly horizontal system activity to transmit lateral forces to the vertical resisting elements:

Building frame system

Braced frame

Diaphragm

Collector

Page 54: 8843531 Structural Reviewer QA

Is a horizontal or nearly horizontal system activity to transmit lateral forces to the vertical resisting elements:

Building frame system

Braced frame

Diaphragm

Collector

Page 55: 8843531 Structural Reviewer QA

Is a frame in which members and joints are capable of resisting forces primarily by flexure:

Moment resisting frame

Ordinary braced frame

Truss

Eccentric braced frame

Page 56: 8843531 Structural Reviewer QA

Is a frame in which members and joints are capable of resisting forces primarily by flexure:

Moment resisting frame

Ordinary braced frame

Truss

Eccentric braced frame

Page 57: 8843531 Structural Reviewer QA

In the determination of seismic dead load with a minimum of ________% of floor live load shall be applicable for storage and

warehouse occupancies. (NSCP 208.5.1.1)

50%

25%

30%

35%

Page 58: 8843531 Structural Reviewer QA

In the determination of seismic dead load with a minimum of ________% of floor live load shall be applicable for storage and

warehouse occupancies. (NSCP 208.5.1.1)

50%

25%

30%

35%

Page 59: 8843531 Structural Reviewer QA

The slope of cut surfaces shall be no steeper than _______% slope. (NSCP 302.2.2)

50%

60%

30%

40%

Page 60: 8843531 Structural Reviewer QA

The slope of cut surfaces shall be no steeper than _______% slope. (NSCP 302.2.2)

50%

60%

30%

40%

Page 61: 8843531 Structural Reviewer QA

Before commencing the excavation work, the person making the excavation shall notify in writing the owner of the adjoining building

not less than _____days before such excavation is to be made. (NSCP 302.2.4)

15 days

10 days

30 days

60 days

Page 62: 8843531 Structural Reviewer QA

Before commencing the excavation work, the person making the excavation shall notify in writing the owner of the adjoining building

not less than _____days before such excavation is to be made. (NSCP 302.2.4)

15 days

10 days

30 days

60 days

Page 63: 8843531 Structural Reviewer QA

Fill slopes shall not be constructed on natural slopes steeper than ____% slope (NSCP 302.3.1)

50%

10%

20%

60%

Page 64: 8843531 Structural Reviewer QA

Fill slopes shall not be constructed on natural slopes steeper than ____% slope (NSCP 302.3.1)

50%

10%

20%

60%

Page 65: 8843531 Structural Reviewer QA

The minimum distance that the toe of fill slope made to the site boundary line: (NSCP 302.4.3)

0.80 M

0.60 M

1.50 M

2.00 M

Page 66: 8843531 Structural Reviewer QA

The minimum distance that the toe of fill slope made to the site boundary line: (NSCP 302.4.3)

0.80 M

0.60 M

1.50 M

2.00 M

Page 67: 8843531 Structural Reviewer QA

The max. distance that the toe of fill slope made to the site boundary: (NSCP 302.4.3)

0.80 M

0.60 M

6.00 M

1.00 M

Page 68: 8843531 Structural Reviewer QA

The max. distance that the toe of fill slope made to the site boundary: (NSCP 302.4.3)

0.80 M

0.60 M

6.00 M

1.00 M

Page 69: 8843531 Structural Reviewer QA

In using sand backfill in the annular space around column not embedded in poured footings, the sand shall be thoroughly compacted by tamping in

layers not more than _____mm in depth? (NSCP 305.7.3)

500 mm

400 mm

200 mm

300 mm

Page 70: 8843531 Structural Reviewer QA

In using sand backfill in the annular space around column not embedded in poured footings, the sand shall be thoroughly compacted by tamping in

layers not more than _____mm in depth? (NSCP 305.7.3)

500 mm

400 mm

200 mm

300 mm

Page 71: 8843531 Structural Reviewer QA

In using a concrete backfill in the annular space around column not embedded in poured footings, the concrete shall have ultimate

strength of ____Mpa at 28 days. (NSCP 305.7.3)

30 Mpa

15 Mpa

10 Mpa

5 Mpa

Page 72: 8843531 Structural Reviewer QA

In using a concrete backfill in the annular space around column not embedded in poured footings, the concrete shall have ultimate

strength of ____Mpa at 28 days. (NSCP 305.7.3)

30 Mpa

15 Mpa

10 Mpa

5 Mpa

Page 73: 8843531 Structural Reviewer QA

When grillage footings of structural steel shapes are used on soils, they shall be completely embedded in concrete. Concrete cover

shall be at least _____mm on the bottom. (NSCP 305.8)

100 mm

200 mm

150 mm

Page 74: 8843531 Structural Reviewer QA

When grillage footings of structural steel shapes are used on soils, they shall be completely embedded in concrete. Concrete cover

shall be at least _____mm on the bottom. (NSCP 305.8)

100 mm

200 mm

150 mm

Page 75: 8843531 Structural Reviewer QA

Temporary open air portable bleachers may be supported upon wood sills or steel plates placed directly upon the ground surface, provided soil pressure does not exceed ____Kpa. (NSCP 305.9)

100 Kpa

50 Kpa

150 Kpa

200 Kpa

Page 76: 8843531 Structural Reviewer QA

Temporary open air portable bleachers may be supported upon wood sills or steel plates placed directly upon the ground surface, provided soil pressure does not exceed ____Kpa. (NSCP 305.9)

100 Kpa

50 Kpa

150 Kpa

200 Kpa

Page 77: 8843531 Structural Reviewer QA

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 2 seismic area in the

Philippines. (NSCP 305.60)

10mm

12mm

16mm

20mm

Page 78: 8843531 Structural Reviewer QA

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 2 seismic area in the

Philippines. (NSCP 305.60)

10mm

12mm

16mm

20mm

Page 79: 8843531 Structural Reviewer QA

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 4 seismic area in the

Philippines. (NSCP 305.60)

10mm

12mm

16mm

20mm

Page 80: 8843531 Structural Reviewer QA

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 4 seismic area in the

Philippines. (NSCP 305.60)

10mm

12mm

16mm

20mm

Page 81: 8843531 Structural Reviewer QA

15%

20%

10%

25%

Individual pile caps and caissons of every structure subjected to seismic forces shall be interconnected by ties. Such ties shall be

capable of resisting in tension or compression a minimum horizontal force equal to _____% of the largest column vertical

load. (NSCP 306.20)

Page 82: 8843531 Structural Reviewer QA

15%

20%

10%

25%

Individual pile caps and caissons of every structure subjected to seismic forces shall be interconnected by ties. Such ties shall be

capable of resisting in tension or compression a minimum horizontal force equal to _____% of the largest column vertical

load. (NSCP 306.20)

Page 83: 8843531 Structural Reviewer QA

Such piles into firm ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20)

1.50 M

2.00 M

2.50 M

3.00 M

Page 84: 8843531 Structural Reviewer QA

Such piles into firm ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20)

1.50 M

2.00 M

2.50 M

3.00 M

Page 85: 8843531 Structural Reviewer QA

Such piles into soft ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20)

1.50 M

2.00 M

2.50 M

3.00 M

Page 86: 8843531 Structural Reviewer QA

Such piles into soft ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20)

1.50 M

2.00 M

2.50 M

3.00 M

Page 87: 8843531 Structural Reviewer QA

The maximum length of cast in place piles/bored piles shall be _____times the average diameter of the pile. (NSCP 307.2.1)

10 times

20 times

30 times

15 times

Page 88: 8843531 Structural Reviewer QA

The maximum length of cast in place piles/bored piles shall be _____times the average diameter of the pile. (NSCP 307.2.1)

10 times

20 times

30 times

15 times

Page 89: 8843531 Structural Reviewer QA

Cast in place/bored piles shall have a specific compressive strength Fc of not less than ______Mpa. (NSCP 307.2.1)

17.50 Mpa

20 Mpa

15 Mpa

25 Mpa

Page 90: 8843531 Structural Reviewer QA

Cast in place/bored piles shall have a specific compressive strength Fc of not less than ______Mpa. (NSCP 307.2.1)

17.50 Mpa

20 Mpa

15 Mpa

25 Mpa

Page 91: 8843531 Structural Reviewer QA

Pre-cast concrete piles shall have a specific compressive strength Fc of not less than _____Mpa. (NSCP 304.7.1)

17.50 Mpa

20 Mpa

15 Mpa

25 Mpa

Page 92: 8843531 Structural Reviewer QA

Pre-cast concrete piles shall have a specific compressive strength Fc of not less than _____Mpa. (NSCP 304.7.1)

17.50 Mpa

20 Mpa

15 Mpa

25 Mpa

Page 93: 8843531 Structural Reviewer QA

The maximum spacing of ties and spirals in a driven pre-cast concrete pile center to center. (NSCP 307.5.1)

75 mm

100 mm

125 mm

150 mm

Page 94: 8843531 Structural Reviewer QA

The maximum spacing of ties and spirals in a driven pre-cast concrete pile center to center. (NSCP 307.5.1)

75 mm

100 mm

125 mm

150 mm

Page 95: 8843531 Structural Reviewer QA

Pre-cast pre-stressed concrete piles shall have a specified compressive strength Fc of not less than ____Mpa.

(NSCP 307.5.1)

20 Mpa

15 Mpa

25 Mpa

35 Mpa

Page 96: 8843531 Structural Reviewer QA

Pre-cast pre-stressed concrete piles shall have a specified compressive strength Fc of not less than ____Mpa.

(NSCP 307.5.1)

20 Mpa

15 Mpa

25 Mpa

35 Mpa

Page 97: 8843531 Structural Reviewer QA

The minimum outside diameter of pipe piles when used must be? (NSCP 307.6.3)

300 mm

250 mm

350 mm

400 mm

Page 98: 8843531 Structural Reviewer QA

The minimum outside diameter of pipe piles when used must be? (NSCP 307.6.3)

300 mm

250 mm

350 mm

400 mm

Page 99: 8843531 Structural Reviewer QA

Aviation control towers fall to what type of occupancy?

Special occupancy structures

Essential facilities

Hazardous facility

Standard occupancy

Page 100: 8843531 Structural Reviewer QA

Aviation control towers fall to what type of occupancy?

Special occupancy structures

Essential facilities

Hazardous facility

Standard occupancy

Page 101: 8843531 Structural Reviewer QA

Private garages, carports, sheds, agricultural buildings fall to what type of occupancy?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 102: 8843531 Structural Reviewer QA

Private garages, carports, sheds, agricultural buildings fall to what type of occupancy?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 103: 8843531 Structural Reviewer QA

Buildings used for college or adult education with a capacity of 500 or more students fall to what type of occupancy?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 104: 8843531 Structural Reviewer QA

Buildings used for college or adult education with a capacity of 500 or more students fall to what type of occupancy?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 105: 8843531 Structural Reviewer QA

Buildings or structures therein housing and supporting toxic or explosive chemicals or substances fall to what type of category?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 106: 8843531 Structural Reviewer QA

Buildings or structures therein housing and supporting toxic or explosive chemicals or substances fall to what type of category?

Miscellaneous occupancy

Essential facilities

Special occupancy

Hazardous facility

Page 107: 8843531 Structural Reviewer QA

The allowable deflection for any structural member loaded with live load only. (NSCP 107.2.2)

L/300

L/360

L/200

L/240

Page 108: 8843531 Structural Reviewer QA

The allowable deflection for any structural member loaded with live load only. (NSCP 107.2.2)

L/300

L/360

L/200

L/240

Page 109: 8843531 Structural Reviewer QA

The allowable deflection for any structural member loaded with dead load and live load only. (NSCP 104.2.2)

L/240

L/300

L/360

L/200

Page 110: 8843531 Structural Reviewer QA

The allowable deflection for any structural member loaded with dead load and live load only. (NSCP 104.2.2)

L/240

L/300

L/360

L/200

Page 111: 8843531 Structural Reviewer QA

Retaining walls shall be designed to resist sliding by at least _______times the lateral force. (NSCP 206.6)

3

2

1.50

1.0

Page 112: 8843531 Structural Reviewer QA

Retaining walls shall be designed to resist sliding by at least _______times the lateral force. (NSCP 206.6)

3

2

1.50

1.0

Page 113: 8843531 Structural Reviewer QA

Retaining walls shall be designed to resist overturning by at least ______times the overturning moment. (NSCP 206.6)

1.0

2.50

2.0

1.50

Page 114: 8843531 Structural Reviewer QA

Retaining walls shall be designed to resist overturning by at least ______times the overturning moment. (NSCP 206.6)

1.0

2.50

2.0

1.50

Page 115: 8843531 Structural Reviewer QA

As per NSCP 2001 sect. 206.9.3 vertical impact force for crane load, if powered monorail cranes are considered, the max. wheel load of the crane shall be increased by what percent to determine

the induced vertical impact? (NSCP 206.9.3)

50%

25%

15%

20%

Page 116: 8843531 Structural Reviewer QA

As per NSCP 2001 sect. 206.9.3 vertical impact force for crane load, if powered monorail cranes are considered, the max. wheel load of the crane shall be increased by what percent to determine

the induced vertical impact? (NSCP 206.9.3)

50%

25%

15%

20%

Page 117: 8843531 Structural Reviewer QA

The lateral force on a crane runway beam with electrically powered trolleys shall be calculated as ______% of the sum of the rated

capacity of the crane and the weight of the hoist and trolley.

(NSCP 206.9.4)

20%

15%

30%

50%

Page 118: 8843531 Structural Reviewer QA

The lateral force on a crane runway beam with electrically powered trolleys shall be calculated as ______% of the sum of the rated

capacity of the crane and the weight of the hoist and trolley.

(NSCP 206.9.4)

20%

15%

30%

50%

Page 119: 8843531 Structural Reviewer QA

The longitudinal forces on crane runway beams, except for bridge cranes with hand geared bridges shall be calculated as _____% of

the max. wheel load of the crane. (NSCP 206.9.5)

15%

10%

25%

20%

Page 120: 8843531 Structural Reviewer QA

The longitudinal forces on crane runway beams, except for bridge cranes with hand geared bridges shall be calculated as _____% of

the max. wheel load of the crane. (NSCP 206.9.5)

15%

10%

25%

20%

Page 121: 8843531 Structural Reviewer QA

An open building is a structure having all walls at least _____% open. (NSCP 207)

50%

60%

80%

75%

Page 122: 8843531 Structural Reviewer QA

An open building is a structure having all walls at least _____% open. (NSCP 207)

50%

60%

80%

75%

Page 123: 8843531 Structural Reviewer QA

Low rise buildings is an enclosed or partially enclosed with mean roof height less than or equal to? (NSCP 207.20)

70 M

50 M

15 M

18 M

Page 124: 8843531 Structural Reviewer QA

Low rise buildings is an enclosed or partially enclosed with mean roof height less than or equal to? (NSCP 207.20)

70 M

50 M

15 M

18 M

Page 125: 8843531 Structural Reviewer QA

The wind load importance factor lw for essential facilities is equal to? (NSCP 207.50)

1.15

1.0

2.15

0.87

Page 126: 8843531 Structural Reviewer QA

The wind load importance factor lw for essential facilities is equal to? (NSCP 207.50)

1.15

1.0

2.15

0.87

Page 127: 8843531 Structural Reviewer QA

The wind load importance factor for hazardous facilities is equal to?

1.0

0.87

1.15

2.15

Page 128: 8843531 Structural Reviewer QA

The wind load importance factor for hazardous facilities is equal to?

1.0

0.87

1.15

2.15

Page 129: 8843531 Structural Reviewer QA

The wind load importance factor for standard occupancy structures is equal to?

1.0

1.15

0.87

2.0

Page 130: 8843531 Structural Reviewer QA

The wind load importance factor for standard occupancy structures is equal to?

1.0

1.15

0.87

2.0

Page 131: 8843531 Structural Reviewer QA

The wind load importance factor for miscellaneous structures is equal to?

1.0

1.15

0.87

2.0

Page 132: 8843531 Structural Reviewer QA

The wind load importance factor for miscellaneous structures is equal to?

1.0

1.15

0.87

2.0

Page 133: 8843531 Structural Reviewer QA

Large city centers with at least 50% of the buildings having a height greater than 21M. falls on what exposure category for wind

loading? (NSCP 207.5.3)

Exposure A

Exposure B

Exposure C

Exposure D

Page 134: 8843531 Structural Reviewer QA

Large city centers with at least 50% of the buildings having a height greater than 21M. falls on what exposure category for wind

loading? (NSCP 207.5.3)

Exposure A

Exposure B

Exposure C

Exposure D

Page 135: 8843531 Structural Reviewer QA

Open terrain with scattered obstructions having heights less than 9M. Falls on what exposure category for wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 136: 8843531 Structural Reviewer QA

Open terrain with scattered obstructions having heights less than 9M. Falls on what exposure category for wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 137: 8843531 Structural Reviewer QA

Flat unobstructed areas exposed to wind flowing over open water for a distance of at least 2 km falls on what exposure category for

wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 138: 8843531 Structural Reviewer QA

Flat unobstructed areas exposed to wind flowing over open water for a distance of at least 2 km falls on what exposure category for

wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 139: 8843531 Structural Reviewer QA

Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single

family dwelling or larger falls on what exposure category for wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 140: 8843531 Structural Reviewer QA

Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single

family dwelling or larger falls on what exposure category for wind loading?

Exposure A

Exposure B

Exposure C

Exposure D

Page 141: 8843531 Structural Reviewer QA

Zone 1 of the Philippine map has a wind velocity of ____Kph?

150 Kph

250 Kph

125 Kph

200 Kph

Page 142: 8843531 Structural Reviewer QA

Zone 1 of the Philippine map has a wind velocity of ____Kph?

150 Kph

250 Kph

125 Kph

200 Kph

Page 143: 8843531 Structural Reviewer QA

Zone 2 of the Philippine map has a wind velocity of ____Kph?

200 Kph

125 Kph

150 Kph

250 Kph

Page 144: 8843531 Structural Reviewer QA

Zone 2 of the Philippine map has a wind velocity of ____Kph?

200 Kph

125 Kph

150 Kph

250 Kph

Page 145: 8843531 Structural Reviewer QA

Zone 3 of the Philippine map has a wind velocity of ____Kph?

200 Kph

125 Kph

150 Kph

250 Kph

Page 146: 8843531 Structural Reviewer QA

Zone 3 of the Philippine map has a wind velocity of ____Kph?

200 Kph

125 Kph

150 Kph

250 Kph

Page 147: 8843531 Structural Reviewer QA

In testing concrete laboratory cured specimens, no individual strength test (average of 2 cylinders) falls below fc’ by more than

_______. (NSCP 405.7.3.3)

5 Mpa

4.25 Mpa

3.50 Mpa

4.0 Mpa

Page 148: 8843531 Structural Reviewer QA

In testing concrete laboratory cured specimens, no individual strength test (average of 2 cylinders) falls below fc’ by more than

_______. (NSCP 405.7.3.3)

5 Mpa

4.25 Mpa

3.50 Mpa

4.0 Mpa

Page 149: 8843531 Structural Reviewer QA

Spacing for a lateral support for a beam shall not exceed _______times the least width b of compression flange or face.

(NSCP 410.5.10)

40

50

60

30

Page 150: 8843531 Structural Reviewer QA

Spacing for a lateral support for a beam shall not exceed _______times the least width b of compression flange or face.

(NSCP 410.5.10)

40

50

60

30

Page 151: 8843531 Structural Reviewer QA

For a rectangular reinforced concrete compression member, it shall be permitted to take the radius of gyration equal to _______times

the overall dimension of the direction of stability is being considered. (NSCP 410.12.20)

0.30

0.45

0.50

0.75

Page 152: 8843531 Structural Reviewer QA

For a rectangular reinforced concrete compression member, it shall be permitted to take the radius of gyration equal to _______times

the overall dimension of the direction of stability is being considered. (NSCP 410.12.20)

0.30

0.45

0.50

0.75

Page 153: 8843531 Structural Reviewer QA

For members whose design is based on compressive force, the slenderness ratio kL/r preferably should not exceed ________?

(NSCP 502.8.1)

300

250

200

350

Page 154: 8843531 Structural Reviewer QA

For members whose design is based on compressive force, the slenderness ratio kL/r preferably should not exceed ________?

(NSCP 502.8.1)

300

250

200

350

Page 155: 8843531 Structural Reviewer QA

For members whose design is based on tensile force, the slenderness ratio L/r preferably should not exceed _________.

200

300

250

350

Page 156: 8843531 Structural Reviewer QA

For members whose design is based on tensile force, the slenderness ratio L/r preferably should not exceed _________.

200

300

250

350

Page 157: 8843531 Structural Reviewer QA

For pin connected members, the allowable stress on the net area of the pinhole for pin connected members is _________.

(NSCP 504.4.1.1)

0.60 Fy

0.50 Fy

0.45 Fy

0.40 Fy

Page 158: 8843531 Structural Reviewer QA

For pin connected members, the allowable stress on the net area of the pinhole for pin connected members is _________.

(NSCP 504.4.1.1)

0.60 Fy

0.50 Fy

0.45 Fy

0.40 Fy

Page 159: 8843531 Structural Reviewer QA

Other than pin connected members, the allowable tensile stress shall not exceed _______ on the gross area. (NSCP 504.2.1)

0.60 Fy

0.45 Fy

0.33 Fy

0.66 Fy

Page 160: 8843531 Structural Reviewer QA

Other than pin connected members, the allowable tensile stress shall not exceed _______ on the gross area. (NSCP 504.2.1)

0.60 Fy

0.45 Fy

0.33 Fy

0.66 Fy

Page 161: 8843531 Structural Reviewer QA

For pin connected plates, the minimum net area beyond the pinhole parallel to the axis of the member shall not be less than _______of the net area across the pinhole. (NSCP 504.4.2.1)

3/4

2/3

3/5

1/3

Page 162: 8843531 Structural Reviewer QA

For pin connected plates, the minimum net area beyond the pinhole parallel to the axis of the member shall not be less than _______of the net area across the pinhole. (NSCP 504.4.2.1)

3/4

2/3

3/5

1/3

Page 163: 8843531 Structural Reviewer QA

For pin connected members in which the pin is expected to provide for relative movement between connected parts while under full

load, the diameter of the pinhole shall not be more than ______mm greater than the diameter of the pin. (NSCP 504.4.2.3)

1 mm

0.5 mm

0.80 mm

2 mm

Page 164: 8843531 Structural Reviewer QA

For pin connected members in which the pin is expected to provide for relative movement between connected parts while under full

load, the diameter of the pinhole shall not be more than ______mm greater than the diameter of the pin. (NSCP 504.4.2.3)

1 mm

0.5 mm

0.80 mm

2 mm

Page 165: 8843531 Structural Reviewer QA

The maximum longitudinal spacing of bolts, nuts and intermittent welds correctly two rolled shapes in contact for a built up section

shall not exceed ________. (NSCP 505.5.4)

700 mm

500 mm

600 mm

400 mm

Page 166: 8843531 Structural Reviewer QA

The maximum longitudinal spacing of bolts, nuts and intermittent welds correctly two rolled shapes in contact for a built up section

shall not exceed ________. (NSCP 505.5.4)

700 mm

500 mm

600 mm

400 mm

Page 167: 8843531 Structural Reviewer QA

The ratio L/r for lacing bars arranged in single system shall not exceed ________. (NSCP 505.5.80)

140 mm

200 mm

250 mm

100 mm

Page 168: 8843531 Structural Reviewer QA

The ratio L/r for lacing bars arranged in single system shall not exceed ________. (NSCP 505.5.80)

140 mm

200 mm

250 mm

100 mm

Page 169: 8843531 Structural Reviewer QA

The ratio L/r for lacing bars arranged in double system shall not exceed ________.

140 mm

200 mm

250 mm

100 mm

Page 170: 8843531 Structural Reviewer QA

The ratio L/r for lacing bars arranged in double system shall not exceed ________.

140 mm

200 mm

250 mm

100 mm

Page 171: 8843531 Structural Reviewer QA

For members bent about their strong or weak axes, members with compact sections where the flanges continuously connected to

web the allowable bending stress is _________. (NSCP 506.4.1.1)

0.75 Fy

0.60 Fy

0.45 Fy

0.66 Fy

Page 172: 8843531 Structural Reviewer QA

For members bent about their strong or weak axes, members with compact sections where the flanges continuously connected to

web the allowable bending stress is _________. (NSCP 506.4.1.1)

0.75 Fy

0.60 Fy

0.45 Fy

0.66 Fy

Page 173: 8843531 Structural Reviewer QA

For box type and tabular textural members that meet the non compact section requirements of section 502.6, the allowable

bending stress is ________. (NSCP 506.4.1.1)

0.75 Fy

0.60 Fy

0.45 Fy

0.66 Fy

Page 174: 8843531 Structural Reviewer QA

For box type and tabular textural members that meet the non compact section requirements of section 502.6, the allowable

bending stress is ________. (NSCP 506.4.1.1)

0.75 Fy

0.60 Fy

0.45 Fy

0.66 Fy

Page 175: 8843531 Structural Reviewer QA

Bolts and rivets connecting stiffness to the girder web shall be spaced not more than ______mm on centers. (NSCP 507.5.3)

300 mm

400 mm

350 mm

250 mm

Page 176: 8843531 Structural Reviewer QA

Bolts and rivets connecting stiffness to the girder web shall be spaced not more than ______mm on centers. (NSCP 507.5.3)

300 mm

400 mm

350 mm

250 mm

Page 177: 8843531 Structural Reviewer QA

Ira composite beam section, the actual section modulus of the transformed composite section shall be used in calculating the

concrete flexural compressed stress and for construction without temporary shores, this stress shall be based upon loading applied after the concrete has reached _____% of its required strength.

50%

60%

80%

75%

Page 178: 8843531 Structural Reviewer QA

Ira composite beam section, the actual section modulus of the transformed composite section shall be used in calculating the

concrete flexural compressed stress and for construction without temporary shores, this stress shall be based upon loading applied after the concrete has reached _____% of its required strength.

50%

60%

80%

75%

Page 179: 8843531 Structural Reviewer QA

Shear connectors shall have at least ________mm of lateral concrete covering. (NSCP 509.5.8)

50 mm

100 mm

25 mm

40 mm

Page 180: 8843531 Structural Reviewer QA

Shear connectors shall have at least ________mm of lateral concrete covering. (NSCP 509.5.8)

50 mm

100 mm

25 mm

40 mm

Page 181: 8843531 Structural Reviewer QA

The minimum center to center spacing of stud connectors along the longitudinal axis of supporting composite beam is

____________.

(NSCP 509.5.8)

6 diameter of connector

10 diameter of connector

12 diameter of connector

5 diameter of connector

Page 182: 8843531 Structural Reviewer QA

The minimum center to center spacing of stud connectors along the longitudinal axis of supporting composite beam is

____________.

(NSCP 509.5.8)

6 diameter of connector

10 diameter of connector

12 diameter of connector

5 diameter of connector

Page 183: 8843531 Structural Reviewer QA

The maximum center to center spacing of stud connectors along the longitudinal axis of supporting composite beam is

____________. (NSCP 509.5.8)

8 diameter of connector

6 diameter of connector

5 diameter of connector

10 diameter of connector

Page 184: 8843531 Structural Reviewer QA

The maximum center to center spacing of stud connectors along the longitudinal axis of supporting composite beam is

____________. (NSCP 509.5.8)

8 diameter of connector

6 diameter of connector

5 diameter of connector

10 diameter of connector

Page 185: 8843531 Structural Reviewer QA

Connections carrying calculated stresses, except for lacing, sag bars and girts, shall be designed to support not less than

________Kn of force. (NSCP 510.10.61)

30

50

26.70

35

Page 186: 8843531 Structural Reviewer QA

Connections carrying calculated stresses, except for lacing, sag bars and girts, shall be designed to support not less than

________Kn of force. (NSCP 510.10.61)

30

50

26.70

35

Page 187: 8843531 Structural Reviewer QA

The connections at ends of tension or compression members in trusses shall develop the force due to the design load, but no less than _______% at the effective strength of the member unless a

smaller percentage is justified by engineering analysis that considers other factors including handling, shipping and erection.

(NSCP 510.2.5.1)

50

70

65

100

Page 188: 8843531 Structural Reviewer QA

The connections at ends of tension or compression members in trusses shall develop the force due to the design load, but no less than _______% at the effective strength of the member unless a

smaller percentage is justified by engineering analysis that considers other factors including handling, shipping and erection.

(NSCP 510.2.5.1)

50

70

65

100

Page 189: 8843531 Structural Reviewer QA

When formed steel decking is a part of the composite beam, the spacing of stud shear connector along the length of the supporting beam or girder shall not exceed _______mm. (NSCP 509.6.1.2)

800

750

900

1000

Page 190: 8843531 Structural Reviewer QA

When formed steel decking is a part of the composite beam, the spacing of stud shear connector along the length of the supporting beam or girder shall not exceed _______mm. (NSCP 509.6.1.2)

800

750

900

1000

Page 191: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness greater than 20mm is ________. (NSCP 510.3.3.2)

10

8

15

20

Page 192: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness greater than 20mm is ________. (NSCP 510.3.3.2)

10

8

15

20

Page 193: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness 6mm is ________? (NSCP 510.3.3.2)

3 mm

6 mm

8 mm

10 mm

Page 194: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness 6mm is ________? (NSCP 510.3.3.2)

3 mm

6 mm

8 mm

10 mm

Page 195: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness over 12mm to 20mm is ________? (NSCP 510.3.3.2)

8 mm

10 mm

6 mm

5 mm

Page 196: 8843531 Structural Reviewer QA

The minimum sizes of filler weld for plates with thickness over 12mm to 20mm is ________? (NSCP 510.3.3.2)

8 mm

10 mm

6 mm

5 mm