8.662 8.606 8.319 7.996 7.769 6 - mackay council · the soil should not contain any clay and be...

16
HWS HWS LINEN LINEN 7.800 7.600 7.400 7.200 7.000 6.800 6.600 6.400 6.200 6.000 8.000 5.149 5.059 5.713 6.310 6.172 5.673 5.226 5.778 6.695 7.020 7.769 6.745 7.996 8.319 8.606 8.662 7.894 7.447 7.166 7.052 7.301 7.569 7.719 8.013 7.871 7.683 7.428 6.088 S H TBM L E ED 14164 OPW - 01 D issue Date 29 APRIL 2014 Scale 1: 150 @ A3 Design Drawn Sheet 01 OF 03 JV CLIENT DWG TITLE JV LANDSCAPE PLAN - OPERATIONAL WORKS DIAL BEFORE YOU DIG WWW. 1100.com.au LANDSCAPE DESIGN INTENT BY MURPHY HOMES PTY LTD TURF TURF TURF TURF TURF TE TE TE 4 x CAL CC 12 x LIR mus 1 x SYZ Cas 12 x LIR mus 1 x SYZ Cas 2 x BUC cel 45 litre 9 x DIE bic 5 x PHI xan 4 x DIE bic SELECT EXPOSED AGGREGATE DRIVEWAY TE 2 x SYZ Res 1800 HIGH TIMBER PALING FENCE 1800 HIGH TIMBER PALING FENCE 1800 HIGH RETURN TIMBER PALING FENCE & GATE 1800 HIGH RETURN TIMBER PALING FENCE & GATE (2.0m high at planting) 1.0m high at planting 4 x CAL CC 1800 HIGH ARTICULATED TIMBER PALING FENCE TO BOUNDARY

Upload: others

Post on 19-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

HWS HWS

LINENLINEN

7.800

7.600

7.400

7.200 7.000

6.80

06.6

00 6.400

6.20

06.

000

8.000

5.149 5.0

595.7

136.3

10

6.172

5.673

5.226

5.778

6.695

7.020

7.769 6.7

45

7.9968.3

19

8.606

8.662

7.894

7.447

7.166

7.052

7.301

7.5697.7198.013

7.871

7.683

7.428

6.088

S

H

TBM

L

E

ED 14164 OPW - 01 D

issue

Date 29 APRIL 2014

Scale 1: 150 @ A3Design DrawnSheet 01 OF 03

JV

CLIENT

DWGTITLE

JV

LANDSCAPE PLAN - OPERATIONAL WORKS

DIAL BEFORE

YOU DIG

WWW. 1100.com.au

LANDSCAPE DESIGN INTENT BY MURPHY HOMES PTY LTD

TURF

TURF

TURF

TURF

TURF

TE

TE

TE

4 x CAL CC

12 x LIR mus

1 x SYZ Cas

12 x LIR mus

1 x SYZ Cas

2 x BUC cel

45 litre

9 x DIE bic

5 x PHI xan

4 x DIE bic

SELECT EXPOSED

AGGREGATE

DRIVEWAY

TE

2 x SYZ Res

1800 HIGH TIMBER

PALING FENCE

1800 HIGH TIMBER

PALING FENCE

1800 HIGH RETURN

TIMBER PALING

FENCE & GATE

1800 HIGH RETURN

TIMBER PALING

FENCE & GATE

(2.0m high at planting)

1.0m high at planting

4 x CAL CC

1800 HIGH

ARTICULATED

TIMBER PALING

FENCE TO

BOUNDARY

tracyh
Received (Manual Date)
Page 2: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

DETAILS PLAN - OPERATIONAL WORKS

DIAL BEFORE

YOU DIG

WWW. 1100.com.au

c

ed

MIN 1500mm

c

ed

c

ed

Tree Planting Distances from Services

ED 14164 OPW - 02 D

issue

Date 29 APRIL 2014Scale

Design DrawnSheet 02 OF 03

JV

CLIENT

DWGTITLE

JV

Page 3: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

SPECIFICATION AND PLANT SCHEDULE PLAN - OPERATIONAL WORKS

DIAL BEFORE

YOU DIG

WWW. 1100.com.au

SPECIFICATION FOR LANDSCAPE WORKS

GENERAL CONDITIONS

SITE PREPARATION /

EARTHWORKS

MATERIALS / SERVICES

HARDSCAPE

PLANT MANAGEMENT

SOFTSCAPE

IRRIGATION

SCOPE PERFORMANCE

LANDSCAPE

ESTABLISHMENT PERIOD

ALL LANDSCAPE CONSTRUCTION WORK IS TO BE CARRIED OUT IN COMPLIANCE WITH RELEVENT COUNCIL APPROVALS AND TO

INDUSTRY BEST PRACTICE. ANY CHANGES FROM DESIGN DOCUMENTATION MUST BE APPROVED BY PROJECT LANDSCAPE ARCHITECT

PRIOR TO CONSTRUCTION ON SITE.

EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE UNDERTAKEN WHERE NECESSARY TO ENSURE NO DETRIMENTAL EFFECT

TO DOWNSTREAM WATERWAYS OR NEIGHBOURING SITES.

PRIOR TO COMMENCEMENT OF WORKS, EXISTING SITE CONDITION IS TO BE DOCUMENTED BY CONTRACTOR. ALL EXISTING AND

PROPOSED SERVICES ON SITE ARE TO BE LOCATED AND CLEARLY IDENTIFIED. ALL BUILDING RUBBISH AND DELETERIOUS MATERIALS

ARE TO BE REMOVED FROM SITE TO APPROVED WASTE LOCATION.

LANDSCAPE AREAS SHALL BE SCARIFIED TO A DEPTH OF 150mm TO PROMOTE GOOD GROWTH FOR TURF AND PLANTING.

ALL MATERIALS TO BE USED IN THE CONSTRUCTION OF THE DESIGNED LANDSCAPE ARE TO BE OF AND INDUSTRY STANDARD QUALITY

AND FROM A SUSTAINABLE SOURCE WHERE POSSIBLE. NO MATERIALS USED ON SITE SHALL BE TOXIC TO HUMANS, ANIMALS OR

PLANTS.

ALL SELECT ITEM MATERIALS ARE TO BE APPROVED BY CLIENT PRIOR TO CONSTRUCTION ON SITE.

PROVIDE SERVICE CONDUITS TO ALL GARDEN BEDS FOR IRRIGATION AND DRAINAGE PURPOSE. PROVIDE CONDUITS FOR LIGHTING

WHERE REQUIRED.

ENSURE ADEQUATE DRAINAGE TO PLANTING AREAS FOR SPECIFIC SITE SOIL CONDITIONS VIA THE USE OF SLOTTED AGRICULTURAL

DRAIN (SELECT TYPE FOR APPLICATION ), OVERLAND FLOW PATHS WITHIN GARDENS ( SELECT RIVER GRAVEL ON GEOFABRIC

MATERIAL) AND SURFACE STORMWATER PITS ( LOCATED IN GENERALLY CONCEALED POSITIONS ).

PROPOSED HARDSCAPE ITEMS ARE TO BE CONSTRUCTED TO AUSTRALIAN STANDARDS AND RELEVENT COUNCIL CODES BY A

SUITABLY LICENCED CONTRACTOR. WORKPLACE HEALTH AND SAFETY REGULATIONS MUST BE IMPLEMENTED DURING CONSTRUCTION

PHASE.

SETOUT OF ALL SOFTSCAPE AREAS TO BE IN ACCORDANCE WITH APPROVED PLANS. PLANTING AREAS TO BE MOUNDED TO ACHIEVE

ADEQUATE DRAINAGE AND AESTHETIC PRESENTATION.

SOIL: A GOOD QUALITY FRIABLE, MODERATELY DRAINING, ORGANIC ENRICHED LANDSCAPING SOIL MIX SHALL BE IMPORTED FROM AN

APPROVED SOURCE. THE SOIL SHOULD NOT CONTAIN ANY CLAY AND BE FREE FROM CONTAMINENTS SUCH AS WEEDS, STICKS AND

ROCKS. IMPLEMENTATION WITHIN GARDEN AREAS TO A MIN. OF 300mm DEPTH.

ORGANIC MULCH: HOOP PINE MULCH IN ITS VARIETY OF FORMS IS TO BE SUPPLIED AND INSTALLED TO A MIN. DEPTH OF 100mm. MULCH

IS TO BE FREE OF FOREIGN MATTER INCLUDING WEEDS, SOIL, STICKS AND ROCKS. AVOID PLACEMENT OF MULCH AGAINST STEM OR

TRUNK OF PLANTS. GRADE MULCH TO BE SELF RETAINED WITHIN GARDEN EDGING.

GRAVEL MULCH: SELECTED WASHED RIVER MULCH GRADED IN SIZE AND COLOUR. USE IN AREAS AS SPECIFIED ON PLANS. TO BE USED

TO SEPERATE ORGANIC MULCH FROM THE WALLS OF BUILDINGS, ADJACENT PATHS AND TOO FACILITATE DRAINAGE WITHIN GARDEN

BEDS. MIN. DEPTH TO BE TWICE THE DIAMETER OF THE LARGEST PEBBLE.

ALL PLANT SPECIES ARE DETAILED WITHIN THE PLANT SCHEDULE . NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR ACCEPTANCE BY

COUNCIL AND PROJECT LANDSCAPE ARCHITECT.

THE CONTRACTOR SHALL OBTAIN ALL PLANTS AS SPECIFIED FROM AN ACCREDITED NURSERY OR OTHER APPROVED SOURCE. PLANTS

SHALL BE PRE-WATERED PRIOR TO ARRIVING ON SITE.

PLANTS SHALL BE HEALTHY, HARDY AND OF GOOD FORM. THE ROOT SYSTEM OF EACH PLANT SHOULD NOT BE ROOTBOUND AND BE

CONDUCIVE TO SUCCESSFUL TRANSPLANTATION. ALL PLANTS TO BE PEST AND DISEASE FREE WITH CONTAINERS FREE FROM WEEDS.

STREET TREE SPECIES ARE TO COMPLY WITH NATSPEC AND RELEVENT COUNCIL CONDITIONS.

STAKE TREES WITH A MIN. OF TWO 50x50 HWD STAKES AND HESSION STRAP OR SIMILAR AS NOT TO DAMAGE TREE. FIGURE '8' DETAIL

RECOMMENDED.

NO TYPE OF STAKE TO BE PLACED THROUGH ROOTBALL OF PLANT AT ANY TIME.

EACH PLANT TO HAVE ADDED WATER CRYSTALS TO PLANTING HOLE AND WATERED IN AFTER PLANTING AS REQUIRED.

PLANT STOCK MAY BE REJECTED IF NOT CONFORMING WITH ABOVE SPECIFICATIONS.

TURF SHALL CONSIST OF A DENSE, WELL ROOTED, VIGOROUS GRASS GROWTH WITH MIN. 25mm OF TOPSOIL. TURF IS TO BE

DELIVERED TO SITE WITHIN 24 HOURS OF BEING CUT. TURF SHOULD BE FREE FROM DELETERIOUS MATERIAL INCLUDING WEEDS,

SEEDS OR ROOTS INCLUDING NUT GRASS AND OXALIS. TURF SHALL BE SUPPLIED IN UNIFORM SIZE IN UNBROKEN CONDITION.

MOISTURE LEVEL OF TURF TO REMAIN CONSISTANT DURING LAYING. TURF TO BE LAID ALONG CONTOUR AND PINNED IF GREATER

THAN 1:4 SLOPE.

PREPARE SUBGRADE TO A LEVEL BASE WITH AN APPROVED TOPSOIL AND SPREAD UNDER TURF FERTILIZER AT RECCOMMENDED

RATE. TURF TO FINISH LEVEL WITH PATHS, EDGES AND KERBS AFTER ROLLING AND SETTLEMENT.

IRRIGATION TO BE INSTALLED BY A SUITABLY QUALIFIED CONTRACTOR AND BE INSTALLED IN ACCORDANCE WITH ALL COUNCIL WATER

REGULATIONS.

THE MOST WATER EFFICIENT METHOD OF IRRIGATION IS TO BE USED, CONNECTED TO TANK SUPPLY WHERE POSSIBLE.

CONDUITS TO BE LAID TO ALL GARDEN AREAS TO PROVIDE A REGULATED COVERAGE. FLUSH AND PRESSURE TEST PRIOR TO

COMMISSIONING.

PROVIDE AS CONSTRUCTED DRAWINGS CLEARLY SHOWING LOCATION OF ALL IRRIGATION COMPONENTRY.

THE CONTRACTOR SHALL BE RESONSIBLE FOR THE CARE AND MAINTENANCE OF ALL LANDSCAPE WORKS FOR A PERIOD OF 13 WEEKS

AFTER COMPLETION.

MAINTENANCE IS TO INCLUDE MOWING OF TURF, REMOVAL AND SPRAYING OF WEEDS, PRUNING AND TRIMMING OF SHRUBS WHERE

REQUIRED, REPLACEMENT OF DEAD OR DISEASED PLANT STOCK AND CORRECT WORKING OF IRRIGATION SYSTEM.

WATER IS TO BE PROVIDED TO ALL SOFT LANDSCAPING AT A REQUIRED RATE DURING THE ESTABLISHMENT PERIOD TO ENSURE

HEALTHY AND VIGOROUS GROWTH.

element design

TM

PLANT SCHEDULE

TREE SPECIES

Code Botanical Name Common Name

GROUNDCOVER SPECIES

QuantitySize

Code Botanical Name Common Name QuantitySize

Code Botanical Name Common Name QuantitySize

element design

SHRUB SPECIES

TM

Contractor to confirm plant quantities prior to ordering

LIR mus Liriope muscari Liriope 140 pot24

(REFER ADDITIONAL NOTE)

BUC cel Buckinghamia celsissima Ivory Curl Flower

245 ltre

Tree Planting Distances from Services

ED 14164 OPW - 03 D

issue

Date 29 APRIL 2014Scale

Design DrawnSheet 03 OF 03

JV

CLIENT

DWGTITLE

JV

SYZ Res Syzygium Resilence Hedging Lilly Pilly

2300 pot

SYZ Cas Syzygium Cascade Cascade

2200 pot

DIE bic Dietes bicolor Wild Iris140 pot

PHI Xan Philodendron ‘xanadu’ Dwarf Philodendron5140 pot

13

CAL CC Callistemon Captain Cook Captain Cook 200 pot 8

TURF

(Provide 'A'-Grade Couch)

Page 4: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

OFFICE USE ONLYAMENDMENTS TO SCHEDULE

REV.STAGED

PLANDATE DESCRIPTION OF CHANGE TO SCHEDULE

15.01.14 A WD'S WORKING DRAWINGS

07.04.14 B WD'S WORKING DRAWINGS

22.04.14 C WD'S WORKING DRAWINGS

28.04.14 D WD'S WORKING DRAWINGS

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

00028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Cover Sheet

DRAWING LIST

000 Cover Sheet

001 3D Perspectives

100 Site Plan

101 Car Turning Circles

200 Ground Floor

202 Roof Plan

300 Elevations

301 Elevations

302 Sections

400 Slab Plan

500 Electrical Plan

600 Kitchen Details

601 Wet Area Details

All material shall be new UNO. Reused items to be checked for soundness etc. prior to use.

- AS PER ENGINEERS DETAILS

b. Walls to have a continuous cavity kept clear of mortar droppings.

a. Brickwork to conform to AS 3700 1998 Masonry in buildings

c. Ceramic tiles or other approved impervious material to walls above showers to 1800mm min above floor.

c. Brick foundation walls under timber floors to have vents at 7500 sq mm per metre length of externalwall. (Approx. 1 brick sized vent every 2 metres.)

a. Floor surfaces to bath & laundry shall be impervious, with junctions between wall and floor flashed to preventmoisture penetration into walls.

Dimensions take preference to scale and are to structure not finish.

Work shall comply with the Building Code of Australia, Building Act Qld, and all relevant current AustralianStandards. Any outdated Standards listed in these notes are to be taken to refer to the current edition.

Check and verify dimensions and confirm any existing dimensions marked.

All dimensions in millimetres.

d. Ground surface to be sloped 1:20 (min) away from building for 900mm (min) and to a pointwhere ponding will not occur near the building.

b. Footings shall be placed as per builders spec or engineers details.

c. Footings to found in non-expansive natural material having a minimum allowable bearing capacity of 100kPa.

e. Dish drains and ag-pipes to be provided as indicated to facilitate drainage of water awayfrom building into drainage system.

It is at the Builders discretion to position bulkheads or service panels underfloor framing to accommodate plumbing services

a. Site to be excavated and or filled to levels shown.

6. UNO = Unless Noted Otherwise.

OMP = Outer Most Point. DPC = Damp Proof Course.

a. All sizes of timber members deduced from AS 1684

c. Sizes of timber members may vary upon ordering requirements but must remain within the guidelinesof the said reference material.

b. All remaining sizes of items deduced from Australian Domestic Construction Manual orrelevant manufacturers specification.

Manufacturers specification means a current approved specification for use under the conditionsapplicable.

STEELWORK

BRICKWORK

REINFORCED CONCRETE

AS APPLICABLE - REFER DWG FOR MATERIALS USED.

WET AREA SURFACES

FRAMING TIMBER

BLOCKWORK

MATERIALS AND CONSTRUCTION

GENERAL NOTES:

SITE WORKS

DESIGN LOADS

c.Any variation at construction stage to comply with Council policy.

b. Position of retaining walls may vary and must be verified by builder prior to commencement.a. All retaining walls are to comply with Council policy on retaining walls and embankments on residential building sites.

RETAINING WALLS

- AS PER ENGINEERS DETAILS

- AS PER ENGINEERS DETAILS

- AS PER AS 1684. 1999 National timber framing code

4.3.

2.1.

5.

7.

d. Provide wall ties at 600mm spacings both vertical and horizontal andwithin 300mm of articulation joints. Brick ties to be stainless steel.

STAIR REQUIREMENTS

Min. tread 240mm, Min.riser 115mm, Max. riser 190mm. Space between open treads Max. 125mm. Treads to be a nonslip surface. Balustrades : min. 1000mm above landings with max. opening of 125mm and in accordanced with BCA3.9.2. For stainless steel ballustrade, refer to table 3.9.2.1 (Wire balustrade construction - required wire tension andmaximum permissible deflection) of the BCA

b. All wet areas to comply with BCA 3.8.1.2 and AS 3740. Splashbacks shall be imperviousfor 150mm above sinks, troughs and hand basins within 75mm of the wall.

TILED DECKS:

Tiled decks over livable areas are to be, in the following order over the floor joists : 19mm compressedFC sheet, with one layer of parchem emerproof 750 with a second layer of sand seed with a DFT of1300 micron, installed to manuf. specifications, and floor tiles over, all corners to have 20mm masticsealant under parchem emerproof 720

SAFTEY GLAZING TO BE USED IN THE FOLLOWING CASES:

a. All rooms - within 500mm vertical of the floorb. Bathrooms within 1500mm vertical of the floorsc. Fully glazed doorsd. Shower screense. Within 300mm of a door and <1200mm above floor levelf. window sizes are nominal only, actual sizes will vary with manufacturer, flashing all round

These plans are to be read in conjuction with any structural and civil engineering computions and drawings

All buildings shall be protected against termite attack in accordance with AS 3660.1 and a durable notice shallbe left in the meter box indicating type of barrier and required periodical inspections

All works shall comply with but not limited to the building code of australia and theaustralian standards listed below.

AS 1288 - 1994 GLASS IN BUILDINGS SELECTION AND INSTALLATION

AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING

AS 1684 - 1999 NATIONAL TIMBER FRAMING CODEAS 2049 - 1992 ROOF TILES

AS 2050 - 1995 INSTALLATION OF ROOF TILES

AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION

AS /NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGS

AS 3600 - 1994 CONCRETE STRUCTURESAS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES

AS 3700 - 1998 MASONRY IN BUILDINGSAS 3786 - 1993 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS

AS 4055 - 1992 WIND LOADING FOR HOUSESAS 4100 - 1996 STEEL STUCTURES

Smoke detectors to be hard wired with emergency back-up and comply with AS3786

Wind speed as nominated on bracing plan or soil test

Provide lift-off hinges to WC or open out door or min. 1200mm clearance from door to pan.

All construction materials supplied must take into account proximity to coastal or industrial environments, in accordance with manuf. specifications

These plans are protected by copy right and are the property of the author.

Page 5: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

00128.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

3D Perspectives

Page 6: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

HWS HWSS

H

TBM

K

L

KK

K

T

E

7.80

0

7.60

0

7.400

7.200

7.0

00

6.8

00

6.6

00

6.4

00

6.2

00

6.0

00

8.000

5.1

49

5.0

59

5.7

13

6.3

10

6.1

72

5.6

73

5.2

26

5.7

78

6.6

95

7.0

20

7.7

69

6.7

45

7.9

96

8.3

19

8.6

06

8.6

62

7.8

94

7.4

47

7.1

66

7.0

52

7.3

01

7.5

69

7.7

19

8.0

13

7.8

71

7.6

83

7.4

28

6.6

39

6.0

88

PROPOSED RESIDENCEGROUND FFL = 7.960

PAD RL = 7.650

PROPOSEDDRIVEWAY

160m²

CARPARKING

BAY

CARPARKING

BAY

LETTERBOXRendered brick

UNIT 1 UNIT 2

FENCE MOUNTEDCLOTHES LINE

D A

W S

O N

B

O U

L E

V A

R D

2600 1500

2600

5000

DP

DP DP

DP

DPDP DP

TAP TAP

TAPTAP

DP

MB MB

277º06'45" (40.446m)

4900

KERB

CROSSOVERTo Local ShireCouncil requirements

FENCE MOUNTEDCLOTHES LINE

BIN STORAGEUnit 2

BIN STORAGEUnit 1

97º17'25" (40.385m)

7º17

'25"

(19

.856

m)

187º

06'4

5" (

19.7

30m

)

A N D E R S O N C O U R T

9450 WALL

9000 OMP

WA

LL

2450

OM

P

2000

5130

WA

LL

4680 O

MP

6780

WA

LL

6330 O

MP

6365 WALL

5915 OMP

KE

RB

EXISTINGCONCRETEFOOTPATH

TO

P O

F E

XIS

TIN

G B

AT

TE

R

TOP OF EXISTING BATTER

TOE OFEXISTING BATTER4

000

6300 D

RIV

EW

AY

GRATED DRAINTo base of driveway

RETAINING WALLAlong property boundary.850mm approx' height asrequired, confirm on site

FIL

L 70

0A

PP

RO

X'

CUT 500APPROX'

CUT / FILL LINE

FILL 50CUT 150

CUT 35

0

FILL 250

FILL

450

FIL

L65

0

TOP OF BATTER

TOE OF BATTER

TO

E O

F B

AT

TE

R

TO

P

TO

P O

F B

AT

TE

R

TO

E O

F B

AT

TE

R

PRIVATE OPENSPACE - 157m²

TOTAL

PRINCIPALPRIVATE

OPEN SPACE4x4m - 16m²

PRINCIPALPRIVATE

OPEN SPACE4x4m - 16m²PRIVATE

OPEN SPACE -90m² TOTAL

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 200

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

10028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Site Plan

1 : 200

SITE PLAN1

NOTE: STORMWATER DRAINAGE CALCULATED FOR BUILDING ROOF AREAS AND ORPAVED AREAS SHOWN ON THIS PROPOSED DEVELOPMENT ONLY, AND MAY NOT BEADEQUATE FOR ANY SUBSEQUENT ROOF OR PAVED AREAS.MIN 100x75 DOWNPIPES ( EACH TO DRAIN MAX 40.00m SQU ROOF AREA) DISCHARINGINTO 100mm S/W DRAINAGE PIPEWORK (EACH RUN CARRYING MAX CAPACITY OF 8litres/sec) MIN GRADE TO RUBBLE PITS ON SITE TO BE 1%. ALL STORMWATER & DRAINAGETO BE IN COMPLIANCE WITH BCA PARTS 3.1.2 & 3.5.2 AS WELL AS ASNZS3500

NOTE : FINAL POSITIONS OF DOWNPIPES,METERBOX, TAPS, AC ODU, WATERTANK, GASBOTTLES AND HOT WATER SYSTEM, MAYDIFFER TO PLAN DUE TO SITE CONDITIONS.

PROPOSED RESIDENCELOT 168SITE AREA = 800m²SITE COVERAGE = 31.5%

AREA SCHEDULE

UNIT 2 LIVING 101.84 m²

UNIT 2 GARAGE 23.73 m²

UNIT 1 GARAGE 23.73 m²

UNIT 1 LIVING 102.43 m²

UNIT 1 PATIO 9.83 m²

UNIT 2 PATIO 9.83 m²

UNIT 1 PORCH 2.81 m²

UNIT 2 PORCH 3.40 m²

Grand total 277.59 m²

LEGEND

DP DOWNPIPE

MB METER BOX

TAP 12mm HOSE COCK -EXTERNAL

AREA SCHEDULE -(Excluding un-enclosed

external spaces)

UNIT 2 LIVING 101.84 m²

UNIT 2 GARAGE 23.73 m²

UNIT 1 GARAGE 23.73 m²

UNIT 1 LIVING 102.43 m²

Grand total 251.73 m²

Page 7: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

HWS HWS

STORAGE - 6m³

6990

CARPARKING

BAY

CARPARKING

BAY

STORAGE - 6m³

16730 1900 4900

480

2600

2050

2600 1500

650

4000

4950

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

10128.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Car Turning Circles

1 : 100

CAR TURNING CIRCLES PLAN1

Page 8: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

HWS HWS

560 MH 560 MH

820

820

820

820

770 770

770 LOH 820

SW1818 820 1500

1800

1200

GARAGE

BED 3

MASTER BED

BED 2

KITCHEN

DININGLIVING

PATIOBATHWC

EN'SWIR

ENTRY

PORCH

L'DRY

SW1215 SW1006 SW1212

SW

1806

SW

1818

SW1818

LINEN

820

820

820

770

770 LOH820

SW1818

1800

GARAGE

BED 3

MASTER BED

BED 2

KITCHEN

DININGLIVING

PATIO

BATH WC

WIR

PORCH

L'DRY

SW1215SW1006SW1212

SW

1806

SW

1818

820

820

EN'S

LINEN

1200

770

1500

ENTRY

2130SGDoxxo

2130SGDoxxo

BRMBRM

220 1720

KITCHEN BENCH

2400 1380 70 1520 70 1520 70 3235 160 3235 70 1520 70 1520 70 3100

KITCHEN BENCH

2400 220

15090

4200 220 2650 70 92070

53070

3235 160 323570

53070

920 70 2650 220 4200 90 150

4440 15690 4440

24570

220 143070

53070

3400 70 3110 70 3235 160 3235 70 3110 70 143070

53070

3400 220

15090

1660220

53070

3000 220 12690 15090

1660220

53070

3000 220

1900 4040 12690 1900 4040

24570

150

90

1410

1650

1650

220

6990

70

3000

220

220

1980

70

950

70

1600

70

1650

70

3600

220

70

950

70 5

307

02720

70

150

90

1810

220

4090

BE

NC

H

800

1100

70 5

307

0950

70

1980

220

10100

2050

12150

220

3000

70

6990

220

1650

220

1980

70

950

70

1600

70

1650

70

3600

220

70

950

7053070

2720

70

3600

220

150

90

1810

220

4090

BE

NC

H

800

1100

70 5

307

0950

70

1980

220 1

50

90

1410

12150

2302

1302

SK

HP+RH

DW

UBO

OHC PTY

IB

REF

200 OVERHANG 200 OVERHANG

PTYOHC

HP+RH

SK

DW

REF

UBO

FW

FW

FW

FW

FW

FW

FW

FW

FW

TR

TR TR

TR

TRH

TRH

TRH

TRH

900

VA

N

900

VA

N

900

VA

N

900

VA

N

900x900 900x900

WM

LT

MECH'EXHAUSTFAN TO ENS'

MECH'EXHAUSTFAN TO ENS'

SD

SD

SD

SD

MB MB

ACC

ACC

ACC

ACC

FWWM

LTSHR SHR

2127 Panel2127 Panel

FIR

E R

AT

ED

PA

RT

Y W

ALL

RE

FE

R D

ET

AIL

STORAGE - 6m³

AIR-CONDITIONERMaster Bed, Unit 2

UNIT 1 UNIT 2

AIR-CONDITIONERMaster Bed, Unit 1

DP

DP DP

DP

DP

DPDP TAPTAP

TAPTAP

DP

HWD POST90 x 90mm

HWD POST90 x 90mm

HWD POST90 x 90mm

HWD POST90 x 90mm

SW1818

SD

1650

OBS OBS OBS OBS

STORAGE - 6m³

420 420

900x1500 900x1500

GASBOTTLES

GASBOTTLES

1 : 100

GROUND FLOOR PLAN1

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

20028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Ground Floor

AREA SCHEDULE

UNIT 2 LIVING 101.84 m²

UNIT 2 GARAGE 23.73 m²

UNIT 1 GARAGE 23.73 m²

UNIT 1 LIVING 102.43 m²

UNIT 1 PATIO 9.83 m²

UNIT 2 PATIO 9.83 m²

UNIT 1 PORCH 2.81 m²

UNIT 2 PORCH 3.40 m²

Grand total 277.59 m²

NOTES :- FINAL POSITIONS OF DOWNPIPES, METERBOX, TAPS, AC ODU,WATERTANK, GAS BOTTLES AND HOT WATER SYSTEM, MAY DIFFER TOPLAN DUE TO SITE CONDITIONS.- LIFT OFF HINGES TO WC DOOR- SARKING TO EXTERNAL WALLS- R2.0 INSULATION TO CEILINGS- ALL SHOWER ROSES TO BE AAA RATED- WATER PRESSURE LIMITED TO 500 KPA AT THE METER- ROOMS WITH NO NATURAL VENTILATION TO HAVE MECHANICALVENTILATION INSTALLED- PROVIDE WATER AND POWER PROVISION TO DISHWASHER SPACE- WINDOW, SGD & INTERNAL DOOR SIZES ARE NOMINAL ONLY & TO BECONFIRMED WITH MANUFACTURER

LEGEND

900 VAN VANITY UNIT - 900LONG

900x900 SHOWER - 900x900

900x1500 SHOWER - 900x1500

ACC AIR-CONDITIONERCONDENSER

DP DOWNPIPE

DW DISHWASHER

FW FLOOR WASTE

HP+RH HOT PLATE ANDRANGEHOOD

IB ISLAND BENCH

LT LAUNDRY TUB

MB METER BOX

OBS OBSCURE GLAZING

OHC CUPBOARD -OVERHEAD

PTY PANTRY FITOUT

REF REFRIGERATOR

SD SMOKE ALARM -IONISATION

SHR SHOWER

SK SINK

TAP 12mm HOSE COCK -EXTERNAL

TR TOWEL RAIL

TRH TOILET ROLLHOLDER

UBO OVEN - UNDERBENCH

WM WASHING MACHINE

Page 9: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

PITCH 22.5°

PITCH 22.5°

PITCH 22.5°

PIT

CH

22.

PIT

CH

22.

PITCH 22.5°

DP

DP

DP DP

DP

DP

DPDP

9450 WALL

9000 OMP

2450

WA

LL

2000 O

MP

5130

WA

LL

4680 O

MP

6780

WA

LL

6330 O

MP

5915 OMP

6365 WALL

5130

WA

LL

4680 O

MP

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

20228.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Roof Plan

1 : 100

ROOF PLAN1

LEGEND

DP DOWNPIPE

Page 10: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

RLGround Floor

7.960

SFLGF Ceiling10.400

2100 J

OIN

ER

Y

2440 C

EIL

ING

VENEER

450FRAME

600

172

86

CbrCbr

Cbr

Cs

Wb

SW1818

SW1806

Cfg Cfg

HWD POST90 x 90mm

HWD POST90 x 90mm

22.5° PITCH

O/H

450POST

600

NGL

RLGround Floor

7.960

SFLGF Ceiling10.400

2100 J

OIN

ER

Y

2440 C

EIL

ING

O/H

450POST

600

O/H

450POST

600

86

86

Cs

CbrCbrCbr

2130SGDoxxo

SW1212SW1006

SW1215SW1215SW1006

SW12122130SGDoxxo

Cfg Cfg

HWD POST90 x 90mm

HWD POST90 x 90mm

22.5° PITCH

OBSOBSOBS

OBS

NGL

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

30028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Elevations

1 : 100

ELEVATION1

1 : 100

ELEVATION2

LEGEND

Cbr Common Brick,Render Finish

Cfg Colorbond Fascia &Gutter

Cs Colorbond SteelRoofing

OBS OBSCURE GLAZING

Wb Scyon Linea Cladding

Page 11: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

RLGround Floor

7.960

SFLGF Ceiling10.400

2100 J

OIN

ER

Y

2440 C

EIL

ING

VENEER

450FRAME

600

86

Cs

WbCbrCbr

SW1806

SW1818

CfgCfg

HWD POST90 x 90mm

22.5° PITCH

O/H

450POST

600

NGL

RLGround Floor

7.960

SFLGF Ceiling10.400

172

172 2100 J

OIN

ER

Y

2440 C

EIL

ING

VENEER

450FRAME

600

POST

600

VENEER

450FRAME

600

CfgCfg

Cs

CsCs

WbWb Cbr

Cbr

Cbr

Cbr

Cbr

SW1818820SW1818 SW1818 820SW18182127 Panel 2127 Panel

HWD POST90 x 90mm

HWD POST90 x 90mm

Cbr Cbr

22.5° PITCH

O/H

450POST

600

NGL

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

30128.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Elevations

1 : 100

ELEVATION3

1 : 100

ELEVATION4

LEGEND

Cbr Common Brick,Render Finish

Cfg Colorbond Fascia &Gutter

Cs Colorbond SteelRoofing

Wb Scyon Linea Cladding

Page 12: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

RLGround Floor

7.960

SFLGF Ceiling10.400

2440 C

EIL

ING

22.5º PITCH TRUSSES@ 900CTRS TOMANUFACTURER'SSPECIFICATIONS

WAFFLE POD SLABTO ENGINEERS DETAILS

GARAGEMASTER BEDKITCHEN GARAGE MASTER BED KITCHEN

NATURAL GROUND LINEShown dashed

RLGround Floor

7.960

SFLGF Ceiling10.400

Wb

Cbr

Cs

2440 C

EIL

ING

GARAGEBED 3

22.5º PITCH TRUSSES@ 900CTRS TOMANUFACTURER'SSPECIFICATIONS

WAFFLE POD SLABTO ENGINEERS DETAILS

NATURAL GROUND LINEShown dashed

22.5º PITCHCOLORBOND ROOFING

BATTEN MAY BECONTINUOUS OVERPARTY WALL.REFER BCA

TRUSSES TOMANUFACTURERSSPECIFICATIONS

MINERAL FIBRE INSULATIONTo fill void between stud framingand roof sheeting

PARTY WALL BETWEEN EACH UNITTO COMPLY WITH THE FIRE &ACOUSTICS SECTIONS OF THE BCA& CSR SPECIFICATIONS

UNIT 1 UNIT 2

16mm GYPROCKFYRCHEK plasterboard

70mm TIMBER STUD

75 GOLD BATTS 1.5

20mm MIN CAVITYBETWEEN TIMBER STUDS

70 20 7016 16

160

PARTY WALLCSR wall system "CSR 556".FRL 60/60/60 withminimum Rw+Ctr 50.Continuous from concrete buildingslab to underside of rood sheeting,between all sole-occupancy units

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

As indicated

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

30228.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

SectionsNOTES:- SELECTED ROOF FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ROOF BATTENS FIXED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ROOF TRUSSES TO MANUFACTURERS SPECIFICATION- BRACING OF TRUSSES TO BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS- ALL TIMBER SIZES TO CONFORM WITH BCA STANDARDS- SLAB & FOOTINGS TO ENGINEERS DETAIL- FLOORING MEMBERS TO ENGINEERS DETAIL

1 : 100

SECTION1

1 : 100

SECTION2

1 : 10

PARTY WALL DETAIL - "CSR 556" WALL SYSTEM3

Page 13: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

ELECTRICAL & WATERSERVICE CONDUIT UNDERSLAB FOR ISLAND BENCH

LINE OF BRICKWORK

NOTES :- WATERTANK SLAB TO BE POURED WITH MAIN SLAB, IF APPLICABLE- EXTERNAL PATIO & PORCH SLABS TO HAVE A 1:100 FALL AWAY FROM HOUSE- SLAB & FOOTINGS TO ENGINEERS DETAIL- TERMITE TREATMENT TO BE INSTALLED AS PER MANUFACTURERS SPEC.& IN ACCORDANCE WITH AS 3660.1- ALL DIMENSIONS TO BE CHECKED AGAINST FLOOR PLAN DIMENSIONS- ALL DIMENSIONS, LEVELS, HEIGHTS TO BE CONFIRMED ON SITE

RL. 7.960 m

RL. 7.874 mRL. 7.874 m

RL. 7.788 m RL. 7.788 m

90x90 HWDPOST FOOTINGTO ENGRS DETAILS

90x90 HWDPOST FOOTINGTO ENGRS DETAILS

90x90 HWDPOST FOOTINGTO ENGRS DETAILS

90x90 HWDPOST FOOTINGTO ENGRS DETAILS

420090

15015090

4200

4440 15690 4440

24570

150

90

1810

1810

90

150

150

90

1410

150

90

1410

150 90 1660 150 90 1660

10100

2050

1650

1900 4040 12690 1900 4040

24570

1650

8450

2050

12150

12150

LIN

E O

F B

RIC

KW

OR

K

LINE OF BRICKWORKLINE OF BRICKWORK

LIN

E O

F B

RIC

KW

OR

K

LINE OF BRICKWORK

172DN 172DN

86DN 86DN

DOOR TRACK

DOOR PANEL

DOOR JAMB

20

20mm RECESS

10mm FALL

30

30

FALL DRIVE 1:100FOR 1000mm MIN

30mm STEP DOWN

WAFFLE POD TOENGINEERS DETAILS

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

As indicated

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

40028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Slab Plan

1 : 100

SLAB LAYOUT PLAN1

1 : 10

GARAGE DOOR DETAIL2

Page 14: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

HWS HWS

560 MH 560 MH

HWS

MB MB

SD

SD

SD

SD

SD

EXHAUSTFAN TO ENS'

EXHAUSTFAN TO ENS'

LIVING 'AC'LIVING 'AC'

AIR-CONDITIONERMaster Bed, Unit 2

AIR-CONDITIONERMaster Bed, Unit 1

NBN NBN

ACC

ACC ACC

ACC

2-WAY 2-WAY

AC

AC

AC

AC

NOTE* - STANDARD HEIGHTS UNLESSSTARTED OTHERWISE.- KITCHEN BENCH DGPO 1100- MICROWAVE 600- RANGEHOOD 1900- LAUNDRY 1350- BATHROOM 1200- LIGHT SWITCHES 1350- DISHWASHER 600- NBN & SGPO 1450

LIGHTING TO COMPLY WITH 40% ENERGYEFFICIENCY REQUIREMENTS

CEILING FAN

CEILING FAN/LIGHT

50mm DICHROIC DOWNLIGHT

SINGLE FLOURESCENT

WALL BUNKER LIGHT

PHONE POINT

TELEVISION POINT

EXHAUST FAN

SINGLE GPO ( 300 high)

DOUBLE GPO ( 300 high)

SINGLE GPO ( refer to notes)

DOUBLE GPO ( refer to notes)

WATERPROOF GPO

METER BOX

HOT WATER SYSTEM

NATIONAL BROADBANDNETWORK CONNECTION BOX

SMOKE ALARM

AIR-CONDITIONER CONDENSER

AIR-CONDITIONER

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 100

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

50028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Electrical Plan

1 : 100

ELECTRICAL LAYOUT PLAN1

Electrical Schedule

Name Count50mm DICHROIC DOWNLIGHT 36

AIR-CONDITIONER 4

AIR-CONDITIONERCONDENSER

4

CEILING FAN 2

CEILING FAN / LIGHT 6

DOUBLE GPO 13

DOUBLE GPO (300 high) 13

EXHAUST FAN 2

HOT WATER SYSTEM 2

METER BOX 2

NBN BOX 2

PHONE POINT 4

SINGLE FLOURESCENT 2

SINGLE GPO 8

SINGLE WATERPROOF GPO(900 AFL)

2

SMOKE ALARM 5

TELEVISION POINT 4

WALL BUNKER LIGHT 4

LEGEND

AC AIR-CONDITIONER

ACC AIR-CONDITIONERCONDENSER

MB METER BOX

NBN NATIONALBROADBANDNETWORK BOX

SD SMOKE ALARM -IONISATION

Page 15: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

10001500900

3400

2400

800

800

1100

600

200 OVERHANG

DRAWERDRAWERS

PANTRY REF SPACE

END PANEL

OVERHEADCUPBOARDS

SKMW DW

HP+RHUBO

600

1

2

DRAWERS

DRAWER

DWMW

END PANEL

OVERHEADCUPBOARDS

SLIDE OUTRANGE HOOD

OVERHEADCUPBOARDS

HP+RH

UBO

PTY REF

FRIDGE RECESS

SHELF RECESSED20mm FROM FACEOR CUPBOARD

1800

300

340

2440

1000

END PANEL

NO BULKHEAD

550

650

900

340

2100

300

BENCH

OVERHEADCUPBOARDS

2440

NOBULKHEAD

Four WhiteMelamineShelves

900

2100

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

As indicated

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

60028.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Kitchen Details

1 : 20

UNIT 1 PART FLOOR PLAN - KITCHEN (UNIT 2 SIMILAR, REFER FLOOR PLAN)A

LEGEND

DW DISHWASHER

HP+RH HOT PLATE ANDRANGEHOOD

MW MICROWAVE SHELF

PTY PANTRY FITOUT

REF REFRIGERATOR

UBO OVEN - UNDERBENCH

1 : 50

ELEVATION - KITCHEN1

1 : 50

ELEVATION - KITCHEN2

1 : 50

FRIDGE RECESS4

1 : 50

BENCH SECTION3

1 : 50

PANTRY DETAIL5

Page 16: 8.662 8.606 8.319 7.996 7.769 6 - Mackay Council · the soil should not contain any clay and be free from contaminents such as weeds, sticks and rocks. implementation within garden

DASHED LINEINDICATES EXTENTS OF100mm SKIRTING TILES

FW

FW

900x900

900

VA

N

TRH

TR

BATHWC

601 1

2

3

4601

5

DASHED LINEINDICATES EXTENTS OF100mm SKIRTING TILES

FW

LT

WM

FWSHR

TRH

900

VA

N

FW

TR

L'DRY

EN'S

601 6

7

8

9

601 10

900x1500

MIRROR

1000 M

IRR

OR

150

850

1000

2000

1000 T

R

TR TR

750 T

RH

TRH

MIRROR

TRH

750 T

RH

1000 M

IRR

OR

150

850

2000

2000 W

AL

L T

ILE

S

1000 T

R

TR

2000

PROVIDE NOGGINGS FORFUTURE CLOTHES DRYER

1500

1200

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

c

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

THIS DESIGN IN PART OR WHOLE IS SUBJECT TO COPYRIGHT MURPHY BUILDERS QLD

BUILDING DESIGNERSJAZZDESIGNS

1 : 50

MURPHY HOMES

LOT 168 ANDERSON COURTPREMIER VISTA ESTATERURAL VIEW, MACKAY QLD 4740

60128.04.14

14 00006

DDH BJC

BASSETT

WORKING DWG'S

CARLISLE

800m²

SP 262600YARRA 29 -SCARBOROUGHFACADE

Wet Area Details

1 : 50

UNIT 1 PART FLOOR PLAN - BATH & WC (UNIT 2 MIRRORED)A

1 : 50

UNIT 1 PART FLOOR PLAN - ENSUITE & L'DRY (UNIT 2 MIRRORED)B

LEGEND

900 VAN VANITY UNIT - 900LONG

900x900 SHOWER - 900x900

LT LAUNDRY TUB

TR TOWEL RAIL

TRH TOILET ROLLHOLDER

WM WASHING MACHINE

1 : 50

ELEVATION - BATH1

1 : 50

ELEVATION - BATH2

1 : 50

ELEVATION - BATH3

1 : 50

ELEVATION - BATH4

1 : 50

ELEVATION - WC5

1 : 50

ELEVATION - ENSUITE6

1 : 50

ELEVATION - ENSUITE7

1 : 50

ELEVATION - ENSUITE8

1 : 50

ELEVATION - ENSUITE9

1 : 50

ELEVATION - LAUNDRY10