8 7 6 5 4 3 1 2 - winnebago · 3/25/2019 · 48d bed-queen, air sleep system 48d 110v (wht) to...
TRANSCRIPT
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
ELECTRICAL SYSTEM-50 AMP
2651B1
1B1
265
78J
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
1.
2. CLAMP TO FLOOR SUPPORT TUBES AS NECESSARY WITH CLAMP10497-01-000.
3. WIRES THAT REST ON WIRE TRAYS ARE TO BE TIED DOWN WITHWIRE TIE 8343-04-000.
5
SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.4
DETAIL AALOCATED IN BASEMENT
BY WATER TANK
LOCATED BEHIND SOFA
FROM RCP-TV,MAIN FROM SIDEWALL
CLAMP10495-01-000 (4)SCREWG67-10-12U (4)
CONNECTOR-WIRE,NM(REF)CONNECTOR-WIRE,SOW(REF)SCREWG39-06-24U (4)
CONNECTOR-WIRE,SOW(REF)CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (4)
SLIDEOUT #1WIRE #1(PUR)
ATS
TO GENERATOR
PANEL-RECEPTACLE151376-01-CHTSCREWG39-10-12U (4)
SLIDEOUT WIRES(YEL,BLU,GLD,GLD-2,BLK)TO 110V CONNECTORSUNDER GALLEY CABT(REF DETAIL EA)
5
110V CONNECTORDETAIL AA
GROMMET23942-02-000
4
RCP-1 (ORG)ENG HTR
RCP-2 (BRN)EXT COMPT
DA
1000 DROP(ORG,PUR,GLD,GLD-2,GRN,RED,YEL,BLK,BRN,MAIN,INVERTER MAIN)1500 DROP(BLU)
AB
CLAMP10497-03-000 (3)SCREWG39-08-12U (3)TO LOAD CENTER
POWER CORD
TO GENERATOR4
VIEW AB
PANEL-CLOSEOUT000122157 / 323237-01-CHTSCREWG39-08-12U (6)
FIREPLACE-ELECTRIC14C
2300 DROP(RED)TO RCP-BLANK,ROOF AC FRONT2300 DROP(GRN)TO RCP-BLANK,ROOF AC REAR
2000 LOOP(BLU)TO RCP-BDRM,TV
BRACKET-110VCONNECTOR,MOUNT155223-08-CHTSCREWG39-10-12U (2)
14C
1000 DROP(GRY)TO RCP-FIREPLACE2500 LOOP(PUR)TO RCP-TV,MAIN
1000 LOOP(BRN)TO GFI-LAVATORY
ROUTE ENGINE HEATER POWER CORD THROUGH GROMMET.6
GROMMET23942-02-000
78J
6
TO GROUND BAR
CLAMP10495-02-000SCREWG39-08-12U
SLIDEOUT #1WIRE #1TO SLIDEOUT
PANEL-CLOSEOUT,ELECTRICAL000155415 / 326372-01-CHTSCREWG39-10-12U (8)
5
PANEL-CLOSEOUT,ELECTRICAL185747-01-CHTSCREWG39-10-12U (4)
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,110V
1 OF 6 000166071 / 32961701000
3
1.5
0.50
1
19 L34T
25-Mar-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
110V WIRE ROUTEDTHROUGH FLOOR INTHIS AREA
THROW IN WIRE #3TO RCP-NIGHTSTAND(RIGHT SIDE)
LOAD CENTER/ATS ASM000015733 / 312954-01-000
SP-06
RCP-B (RED)ROOF,A/C FRT
RCP-B (GRN)ROOF,A/C RR
110V CONNECTOR(REF DETAIL AA)
NOTES:
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.3
THROW IN WIRE #3TO LEFT NIGHTSTAND3
RCP-2 (BLU)TV,BDRM
RCP-2 (PUR)DINETTE
RCP-2 (BLU)NIGHTSTAND,LH
110V WIREROUTED THROUGHFLOOR IN THIS AREA
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.
1.
PUSH WIRE THROUGH ROUTED PATH IN SIDEWALL.2
3
2
110V WIRE ROUTEDTHROUGH FLOOR INTHIS AREA
3
RCP-2 (PUR)OVHD,RR
RCP-2 (PUR)OVHD,FRT
RCP-B (PUR)SOFA
THROW IN WIRE #6
RCP-2 (BLU)BEDROOM OVHD
SP-06
RCP-B (BLU)BED
48D BED-QUEEN, AIR SLEEP SYSTEM
48D
110V (WHT)TO WATER HEATER
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000166071 / 32961701000 2 OF 6
RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BRN) (LAVATORY)
1B1
265
RCP-1 (BLU)AIR BED
25-Mar-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
RCP-3 (YEL)REFRIGERATOR
THROW IN WIRE #3TO RIGHT NIGHTSTAND
SP-06
THROW IN WIRE #3FROM RCP-NIGHTSTAND,LH
110V WIRESROUTED THROUGHFLOOR IN THIS AREA
110V CONNECTORS(REF DETAIL EA)
RCP-2S (BLU)GALLEY #2
RCP-1 (BLK)MICROWAVE
RCP-2S (BLU)GALLEY #1
RCP-1 (GLD-2)DRYER
RCP-1 (GLD)WASHER
RCP-2 (BLU)NIGHTSTAND,RH
SP-06
BLU & BLKFROM SIDEWALL(REF DETAIL EA)
SP-06
SP-06
SP-06
RCP-2 (PUR)FRONT
RCP-3 (GRY)FIREPLACE
FIREPLACE-ELECTRIC
14C
RCP-2 (PUR)TV
RCP-2 (PUR)COMPONENT
14C
1.
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
2 PUSH WIRE THROUGH ROUTED PATH IN SIDEWALL.
3
2 3
3
SP-06
RCP-EXT ENT CTR(REF)
THROW IN WIRE #7
4
1DF
RCP-B (BLU)GALLEY
1DF EXT TV ENTERTAINMENT CENTER4 ADD BLANK RCP IN-LINE WITH BLUE CIRCUIT FROM SIDEWALL
TO FEED EXT ENT CTR RCP WITH
1DF
1DF
1DF
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000166071 / 32961701000 3 OF 6
RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BLU) (GALLEY)
265
1B1
RCP-2 (PUR)SUBWOOFER
RCP-3 (GRY)FIREPLACE
25-Mar-2019
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
AC OUTPUT10 GA WIREFROM INVERTERBREAKER PANELDETAIL DB
1
BRACKET IS LOCATED BY HOLES ON BRACKET.
6
REMOTE DISPLAYPANEL & AC TEMPSENSOR CONNECTION
3
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
3
3
1
INVERTER175386-02-000NUTD39-06-00B (4)
POSITIVE BATTERYCABLE CONNECTION
6
BRACKET176315-10-CHTNUT000D39-04-00U (4)
1
DETAIL DA
NEGATIVE BATTERYCABLE CONNECTION
5
4
6
1
CONNECTOR-WIRE008311-01-000 (5)
DO NOT USE POWER/AIR TOOL TO INSTALL NUT. TORQUE TO 10-12 FT LBS.
SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.
2
SEE INVERTER/CHARGER OWNER'S MANUAL FOR ADDITIONAL INFORMATION.
WIRE ASM-GROUND
CABLES PART OF WIRE ASM-COACH.
AC INPUT10 GA WIREFROM MAINBREAKER PANELDETAIL DB
NOTES: DETAIL DB
2
5
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000166071 / 32961701000 4 OF 625-Mar-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
BRACKET-110V CONNECTOR155223-12-CHT (2)SCREWG39-10-12U (6)
DETAIL EA
SLIDEOUTWIRE #3(BLU)
SLIDEOUTWIRE #2(YEL)
SLIDEOUTWIRE #5(GLD)
SLIDEOUTWIRE #6(GLD-2)
LOCATED UNDERGALLEY CABT
LOCATED UNDERTHE GALLEY CABT
TO RCP-DRYER(GLD-2)
TO RCP-WASHER(GLD)
TO RCP-REFRIGERATOR(YEL)
TO RCP-GALLEY(BLU)
CLAMP10495-01-000 (10)SCREWG67-10-12U (10)
SLIDEOUTWIRE #4(BLK)
CLAMP10495-01-000 (10)SCREWG67-10-12U (10)
TO RCP-MICROWAVE(BLK)
WIRE ROUTED INSIDEWALL (BLK)
CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (2)
WIRE ROUTED INSIDEWALL (BLU)
CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (2)
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.1
NOTES:
1
1
1
1
1
THROW IN WIRE #1
THROW IN WIRE #4
THROW IN WIRE #5 1
1
1
CONNECTOR-WIRE,NM(REF) (8 PLACES)SCREWG39-06-24U (16)
CONNECTOR-WIRE,SOW(REF) (10 PLACES)SCREWG39-06-24U (20)
FROM GFI-GALLEY(BLU)
FROM LOAD CENTER(BLK)
FROM LOAD CENTER(GLD-2)
FROM LOAD CENTER(GLD)
FROM LOAD CENTER(YEL)
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000166071 / 32961701000 5 OF 625-Mar-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
NOTES:
ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND FAULT INTERUPT PROTECTED.
WIRE ROUTED IN ROOF.
WIRE ROUTED IN SIDEWALL.
2
1
3
4
14-2
14-2
14-2
10-2
4
SLIDEOUTWIRE #4
110V CONNECTION(LOCATED UNDER
GALLEY)RCP-
MICROWAVE
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
RCP-REFRIG
SLIDEOUTWIRE #2
INVERTER
110V CONNECTION(LOCATED UNDER
GALLEY)
110V CONNECTION(LOCATED UNDER
GALLEY CABT)THROW IN WIRE #1
RCP-BDRM TV
4
FROMINVERTER
14-2
THROW IN WIRE #3
RCP-NIGHTSTAND,
RH
RCP-GALLEY #1
4
RCP-NIGHTSTAND,
LH
RCP-GALLEY #2
WIRE IS PUSHED THROUGH SIDEWALL TO RECEPTACLE.
2
2
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
FIREPLACE-ELECTRIC14C
4
RCP-BDINETTE
RCP-DINETTE
RCP-BEDROOM
OVHD
3
4RCP-
TV
RCP-COMPONENT
SLIDEOUTWIRE #1
110V CONNECTION(LOCATED IN
BASEMENT)
110V CONNECTION(LOCATED UNDER
SOFA)
RCP-BLANKBED(LOCATED UNDERBED BASE CABT)
RCP-GFIGALLEY
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
SLIDEOUTWIRE #3
1
RCP-OVHD,FRT
RCP-OVHD,RR
4THROW INWIRE #6
RCP-FRONT
4
THROW IN WIRE #7
BED-QUEEN, AIR SLEEP SYSTEM48D
48D
RCP-GALLEY #1
44
RCP-GALLEY #2
RCP- BLANK,EXT ENT CTR
(UNDER GALLEY)
RCP-EXTENT CTR
1DF
1DF EXT TV ENTERTAINMENT CENTER
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000166071 / 32961701000 6 OF 6
RED
BLK
RED
WHT
GND
3
BLK
GND
WHT
BLK
RED
GND
WHT
3
RED
12-2
GENERATOR
BLK
14-2
TOINVERTER
RCP-FIREPLACE
RCP-DRYER
NO
GROUND
GROUND
6-3
4-3
FRONTA/C
RCP-ENGINEHEATER
NO
RED
POWERCORD
14-210-2
RCP-BLANK,
ROOFA/C RR
(LOCATEDABOVE
WASHER)
12-2
COM
14-2
BLK
14-2
4-3
WATERHEATER
MAIN PANEL
RCP-GFIBATHROOM
COM
NC
8 GRN14-2
6-3
12-2
RCP-BLANK,
ROOFA/C FRT
(LOCATEDABOVE
WASHER)
1 BLK
1
REARA/C
NC
RED
RCP-WASHER
BLK
RCP-EXTERIOR
COMPARTMENT
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
THROW IN WIRE #5 SLIDEOUT WIRE #6
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
110V CONNECTION(LOCATED UNDER
GALLEY CABT)
THROW IN WIRE #4 SLIDEOUT WIRE #5
14C
RCP-SUBWOOFER
RCP-OVHDFRONT
RCP-AIRBED
25-Mar-2019