8 7 6 5 4 3 1 2 - winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to...

6
X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 CODES/STANDARDS USA CODES/STANDARDS-CSA/CMVSS ELECTRICAL SYSTEM-50 AMP 265 1B1 1B1 265 78J NOTES: AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION. SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION. 1. 2. CLAMP TO FLOOR SUPPORT TUBES AS NECESSARY WITH CLAMP 10497-01-000. 3. WIRES THAT REST ON WIRE TRAYS ARE TO BE TIED DOWN WITH WIRE TIE 8343-04-000. 5 SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION. 4 DETAIL AA LOCATED IN BASEMENT BY WATER TANK LOCATED BEHIND SOFA FROM RCP- TV,MAIN FROM SIDEWALL CLAMP 10495-01-000 (4) SCREW G67-10-12U (4) CONNECTOR-WIRE,NM (REF) CONNECTOR-WIRE,SOW (REF) SCREW G39-06-24U (4) CONNECTOR-WIRE,SOW (REF) CONNECTOR-WIRE,NM 144283-02-000 SCREW G39-06-24U (4) SLIDEOUT #1 WIRE #1 (PUR) ATS TO GENERATOR PANEL-RECEPTACLE 151376-01-CHT SCREW G39-10-12U (4) SLIDEOUT WIRES (YEL,BLU,GLD,GLD-2,BLK) TO 110V CONNECTORS UNDER GALLEY CABT (REF DETAIL EA) 5 110V CONNECTOR DETAIL AA GROMMET 23942-02-000 4 RCP-1 (ORG) ENG HTR RCP-2 (BRN) EXT COMPT DA 1000 DROP (ORG,PUR,GLD,GLD-2, GRN,RED,YEL,BLK,BRN, MAIN,INVERTER MAIN) 1500 DROP (BLU) AB CLAMP 10497-03-000 (3) SCREW G39-08-12U (3) TO LOAD CENTER POWER CORD TO GENERATOR 4 VIEW AB PANEL-CLOSEOUT 000122157 / 323237-01-CHT SCREW G39-08-12U (6) FIREPLACE-ELECTRIC 14C 2300 DROP (RED) TO RCP-BLANK, ROOF AC FRONT 2300 DROP (GRN) TO RCP-BLANK, ROOF AC REAR 2000 LOOP (BLU) TO RCP-BDRM,TV BRACKET-110V CONNECTOR,MOUNT 155223-08-CHT SCREW G39-10-12U (2) 14C 1000 DROP (GRY) TO RCP-FIREPLACE 2500 LOOP (PUR) TO RCP-TV,MAIN 1000 LOOP (BRN) TO GFI-LAVATORY ROUTE ENGINE HEATER POWER CORD THROUGH GROMMET. 6 GROMMET 23942-02-000 78J 6 TO GROUND BAR CLAMP 10495-02-000 SCREW G39-08-12U SLIDEOUT #1 WIRE #1 TO SLIDEOUT PANEL-CLOSEOUT,ELECTRICAL 000155415 / 326372-01-CHT SCREW G39-10-12U (8) 5 PANEL-CLOSEOUT, ELECTRICAL 185747-01-CHT SCREW G39-10-12U (4) 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,110V 1 OF 6 000166071 / 32961701000 3 1.5 0.50 1 19 L34T 25-Mar-2019

Upload: others

Post on 13-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

ELECTRICAL SYSTEM-50 AMP

2651B1

1B1

265

78J

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

1.

2. CLAMP TO FLOOR SUPPORT TUBES AS NECESSARY WITH CLAMP10497-01-000.

3. WIRES THAT REST ON WIRE TRAYS ARE TO BE TIED DOWN WITHWIRE TIE 8343-04-000.

5

SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.4

DETAIL AALOCATED IN BASEMENT

BY WATER TANK

LOCATED BEHIND SOFA

FROM RCP-TV,MAIN FROM SIDEWALL

CLAMP10495-01-000 (4)SCREWG67-10-12U (4)

CONNECTOR-WIRE,NM(REF)CONNECTOR-WIRE,SOW(REF)SCREWG39-06-24U (4)

CONNECTOR-WIRE,SOW(REF)CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (4)

SLIDEOUT #1WIRE #1(PUR)

ATS

TO GENERATOR

PANEL-RECEPTACLE151376-01-CHTSCREWG39-10-12U (4)

SLIDEOUT WIRES(YEL,BLU,GLD,GLD-2,BLK)TO 110V CONNECTORSUNDER GALLEY CABT(REF DETAIL EA)

5

110V CONNECTORDETAIL AA

GROMMET23942-02-000

4

RCP-1 (ORG)ENG HTR

RCP-2 (BRN)EXT COMPT

DA

1000 DROP(ORG,PUR,GLD,GLD-2,GRN,RED,YEL,BLK,BRN,MAIN,INVERTER MAIN)1500 DROP(BLU)

AB

CLAMP10497-03-000 (3)SCREWG39-08-12U (3)TO LOAD CENTER

POWER CORD

TO GENERATOR4

VIEW AB

PANEL-CLOSEOUT000122157 / 323237-01-CHTSCREWG39-08-12U (6)

FIREPLACE-ELECTRIC14C

2300 DROP(RED)TO RCP-BLANK,ROOF AC FRONT2300 DROP(GRN)TO RCP-BLANK,ROOF AC REAR

2000 LOOP(BLU)TO RCP-BDRM,TV

BRACKET-110VCONNECTOR,MOUNT155223-08-CHTSCREWG39-10-12U (2)

14C

1000 DROP(GRY)TO RCP-FIREPLACE2500 LOOP(PUR)TO RCP-TV,MAIN

1000 LOOP(BRN)TO GFI-LAVATORY

ROUTE ENGINE HEATER POWER CORD THROUGH GROMMET.6

GROMMET23942-02-000

78J

6

TO GROUND BAR

CLAMP10495-02-000SCREWG39-08-12U

SLIDEOUT #1WIRE #1TO SLIDEOUT

PANEL-CLOSEOUT,ELECTRICAL000155415 / 326372-01-CHTSCREWG39-10-12U (8)

5

PANEL-CLOSEOUT,ELECTRICAL185747-01-CHTSCREWG39-10-12U (4)

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,110V

1 OF 6 000166071 / 32961701000

3

1.5

0.50

1

19 L34T

25-Mar-2019

Page 2: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

110V WIRE ROUTEDTHROUGH FLOOR INTHIS AREA

THROW IN WIRE #3TO RCP-NIGHTSTAND(RIGHT SIDE)

LOAD CENTER/ATS ASM000015733 / 312954-01-000

SP-06

RCP-B (RED)ROOF,A/C FRT

RCP-B (GRN)ROOF,A/C RR

110V CONNECTOR(REF DETAIL AA)

NOTES:

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.3

THROW IN WIRE #3TO LEFT NIGHTSTAND3

RCP-2 (BLU)TV,BDRM

RCP-2 (PUR)DINETTE

RCP-2 (BLU)NIGHTSTAND,LH

110V WIREROUTED THROUGHFLOOR IN THIS AREA

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

1.

PUSH WIRE THROUGH ROUTED PATH IN SIDEWALL.2

3

2

110V WIRE ROUTEDTHROUGH FLOOR INTHIS AREA

3

RCP-2 (PUR)OVHD,RR

RCP-2 (PUR)OVHD,FRT

RCP-B (PUR)SOFA

THROW IN WIRE #6

RCP-2 (BLU)BEDROOM OVHD

SP-06

RCP-B (BLU)BED

48D BED-QUEEN, AIR SLEEP SYSTEM

48D

110V (WHT)TO WATER HEATER

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000166071 / 32961701000 2 OF 6

RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BRN) (LAVATORY)

1B1

265

RCP-1 (BLU)AIR BED

25-Mar-2019

Page 3: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

RCP-3 (YEL)REFRIGERATOR

THROW IN WIRE #3TO RIGHT NIGHTSTAND

SP-06

THROW IN WIRE #3FROM RCP-NIGHTSTAND,LH

110V WIRESROUTED THROUGHFLOOR IN THIS AREA

110V CONNECTORS(REF DETAIL EA)

RCP-2S (BLU)GALLEY #2

RCP-1 (BLK)MICROWAVE

RCP-2S (BLU)GALLEY #1

RCP-1 (GLD-2)DRYER

RCP-1 (GLD)WASHER

RCP-2 (BLU)NIGHTSTAND,RH

SP-06

BLU & BLKFROM SIDEWALL(REF DETAIL EA)

SP-06

SP-06

SP-06

RCP-2 (PUR)FRONT

RCP-3 (GRY)FIREPLACE

FIREPLACE-ELECTRIC

14C

RCP-2 (PUR)TV

RCP-2 (PUR)COMPONENT

14C

1.

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

2 PUSH WIRE THROUGH ROUTED PATH IN SIDEWALL.

3

2 3

3

SP-06

RCP-EXT ENT CTR(REF)

THROW IN WIRE #7

4

1DF

RCP-B (BLU)GALLEY

1DF EXT TV ENTERTAINMENT CENTER4 ADD BLANK RCP IN-LINE WITH BLUE CIRCUIT FROM SIDEWALL

TO FEED EXT ENT CTR RCP WITH

1DF

1DF

1DF

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000166071 / 32961701000 3 OF 6

RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BLU) (GALLEY)

265

1B1

RCP-2 (PUR)SUBWOOFER

RCP-3 (GRY)FIREPLACE

25-Mar-2019

Page 4: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

AC OUTPUT10 GA WIREFROM INVERTERBREAKER PANELDETAIL DB

1

BRACKET IS LOCATED BY HOLES ON BRACKET.

6

REMOTE DISPLAYPANEL & AC TEMPSENSOR CONNECTION

3

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

3

3

1

INVERTER175386-02-000NUTD39-06-00B (4)

POSITIVE BATTERYCABLE CONNECTION

6

BRACKET176315-10-CHTNUT000D39-04-00U (4)

1

DETAIL DA

NEGATIVE BATTERYCABLE CONNECTION

5

4

6

1

CONNECTOR-WIRE008311-01-000 (5)

DO NOT USE POWER/AIR TOOL TO INSTALL NUT. TORQUE TO 10-12 FT LBS.

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.

2

SEE INVERTER/CHARGER OWNER'S MANUAL FOR ADDITIONAL INFORMATION.

WIRE ASM-GROUND

CABLES PART OF WIRE ASM-COACH.

AC INPUT10 GA WIREFROM MAINBREAKER PANELDETAIL DB

NOTES: DETAIL DB

2

5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000166071 / 32961701000 4 OF 625-Mar-2019

Page 5: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

BRACKET-110V CONNECTOR155223-12-CHT (2)SCREWG39-10-12U (6)

DETAIL EA

SLIDEOUTWIRE #3(BLU)

SLIDEOUTWIRE #2(YEL)

SLIDEOUTWIRE #5(GLD)

SLIDEOUTWIRE #6(GLD-2)

LOCATED UNDERGALLEY CABT

LOCATED UNDERTHE GALLEY CABT

TO RCP-DRYER(GLD-2)

TO RCP-WASHER(GLD)

TO RCP-REFRIGERATOR(YEL)

TO RCP-GALLEY(BLU)

CLAMP10495-01-000 (10)SCREWG67-10-12U (10)

SLIDEOUTWIRE #4(BLK)

CLAMP10495-01-000 (10)SCREWG67-10-12U (10)

TO RCP-MICROWAVE(BLK)

WIRE ROUTED INSIDEWALL (BLK)

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (2)

WIRE ROUTED INSIDEWALL (BLU)

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (2)

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.1

NOTES:

1

1

1

1

1

THROW IN WIRE #1

THROW IN WIRE #4

THROW IN WIRE #5 1

1

1

CONNECTOR-WIRE,NM(REF) (8 PLACES)SCREWG39-06-24U (16)

CONNECTOR-WIRE,SOW(REF) (10 PLACES)SCREWG39-06-24U (20)

FROM GFI-GALLEY(BLU)

FROM LOAD CENTER(BLK)

FROM LOAD CENTER(GLD-2)

FROM LOAD CENTER(GLD)

FROM LOAD CENTER(YEL)

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000166071 / 32961701000 5 OF 625-Mar-2019

Page 6: 8 7 6 5 4 3 1 2 - Winnebago · 3/25/2019  · 48d bed-queen, air sleep system 48d 110v (wht) to water heater 8 5 1 4 7 sheet: 2 4 c a description: b 3 2 rev a item/part no: 3 d 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

NOTES:

ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND FAULT INTERUPT PROTECTED.

WIRE ROUTED IN ROOF.

WIRE ROUTED IN SIDEWALL.

2

1

3

4

14-2

14-2

14-2

10-2

4

SLIDEOUTWIRE #4

110V CONNECTION(LOCATED UNDER

GALLEY)RCP-

MICROWAVE

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

RCP-REFRIG

SLIDEOUTWIRE #2

INVERTER

110V CONNECTION(LOCATED UNDER

GALLEY)

110V CONNECTION(LOCATED UNDER

GALLEY CABT)THROW IN WIRE #1

RCP-BDRM TV

4

FROMINVERTER

14-2

THROW IN WIRE #3

RCP-NIGHTSTAND,

RH

RCP-GALLEY #1

4

RCP-NIGHTSTAND,

LH

RCP-GALLEY #2

WIRE IS PUSHED THROUGH SIDEWALL TO RECEPTACLE.

2

2

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

FIREPLACE-ELECTRIC14C

4

RCP-BDINETTE

RCP-DINETTE

RCP-BEDROOM

OVHD

3

4RCP-

TV

RCP-COMPONENT

SLIDEOUTWIRE #1

110V CONNECTION(LOCATED IN

BASEMENT)

110V CONNECTION(LOCATED UNDER

SOFA)

RCP-BLANKBED(LOCATED UNDERBED BASE CABT)

RCP-GFIGALLEY

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

SLIDEOUTWIRE #3

1

RCP-OVHD,FRT

RCP-OVHD,RR

4THROW INWIRE #6

RCP-FRONT

4

THROW IN WIRE #7

BED-QUEEN, AIR SLEEP SYSTEM48D

48D

RCP-GALLEY #1

44

RCP-GALLEY #2

RCP- BLANK,EXT ENT CTR

(UNDER GALLEY)

RCP-EXTENT CTR

1DF

1DF EXT TV ENTERTAINMENT CENTER

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000166071 / 32961701000 6 OF 6

RED

BLK

RED

WHT

GND

3

BLK

GND

WHT

BLK

RED

GND

WHT

3

RED

12-2

GENERATOR

BLK

14-2

TOINVERTER

RCP-FIREPLACE

RCP-DRYER

NO

GROUND

GROUND

6-3

4-3

FRONTA/C

RCP-ENGINEHEATER

NO

RED

POWERCORD

14-210-2

RCP-BLANK,

ROOFA/C RR

(LOCATEDABOVE

WASHER)

12-2

COM

14-2

BLK

14-2

4-3

WATERHEATER

MAIN PANEL

RCP-GFIBATHROOM

COM

NC

8 GRN14-2

6-3

12-2

RCP-BLANK,

ROOFA/C FRT

(LOCATEDABOVE

WASHER)

1 BLK

1

REARA/C

NC

RED

RCP-WASHER

BLK

RCP-EXTERIOR

COMPARTMENT

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

THROW IN WIRE #5 SLIDEOUT WIRE #6

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

110V CONNECTION(LOCATED UNDER

GALLEY CABT)

THROW IN WIRE #4 SLIDEOUT WIRE #5

14C

RCP-SUBWOOFER

RCP-OVHDFRONT

RCP-AIRBED

25-Mar-2019