  • PackagingMasterSealHLM5000SL,HLM5000S,andHLM5000R:5gal(18.95L)pails,55gal(208L) drums;availablespecialorder

    MasterSealHLM5000T:5gal(18.95L)pailsMasterSeal995:300ftby371/2"(91by0.9m)rolls,yielding937ft2(87m2)

    MasterSeal977:-50milby40"by48"(1.3mmby1mby1.2m)sheets,500perpallet,yielding1313ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.

    -120mil(18")by40"by48"(3mmby1mby1.2m)sheets,500perpallet,yielding1313ft2(1.2m2)persheetor6,665ft2(619m2)perpallet.

    Liquid, cold-applied elastomeric waterproofing membrane systemFoRMeRLySonoSHieLdHLM5000

    071400Fluid-applied Waterproofing7

    PRODUcT HigHLigHTSAvailableinstandardandhigh-buildsystemsWaterproofingmembranetopreventwaterpenetration

    elastomericaccommodatesexpansionandcontraction

    Wideservice-temperaturerange,makingMasterSealHLM5000suitableforallclimates

    Chemicalresistancetobacterialattack,selectacids,alkalisandsalts

    Seamlesscold-appliedmembraneeliminateslapping,seamingandprecutting

    doesnotrequirehot-meltequipment

    aPPLicaTiOnSConcretePlywood(exterior)exteriorbelowgrade(onmasonry,concrete,andincidentalmetal)

    Abovegrade(betweentwo-courseconcreteandwithincavitywalls)

    ParkinggaragesandconcretetanksPlazadecksandmallsFountainsandpoolsBalconiesandplantersBelow-gradeslabsWallsandculvertsSeawalls,damsandreservoirs

    MasterSeal HLM 5000

    DeScRiPTiOnMasterSealHLM5000isaone-component,moisture-curing,bitumen-modifiedpolyurethaneelastomericwaterproofingmembraneforexteriorbelow-gradeorbetween-slabapplications.itisavailableinfourgrades:MasterSealHLM5000SL(self-leveling/squeegee) MasterSealHLM5000S(spray)MasterSealHLM5000T(trowel) MasterSealHLM5000R(roller)

    YieLD 2530ft2/galat5565wetmils(0.610.74m2/Lat1.41.7mmwetthickness)

    2530ft2/galat4555drymils(0.610.74m2/Lat1.11.4mmdrythickness)

    Coveragemayvarywiththeapplicationtechniqueused.Actualcoveragerateandmilthicknessdependonfinishandporosityofthesubstrate.

    STORage Storeinunopenedcontainersinclean,dryconditionsat40to80F(4to27C).duringstorage,aneasilyremovedskinofHLM5000mayform,whichdoesnotaffectperformanceoftheproduct.

    SHeLF LiFe1yearPails6Monthsdrums

    VOc cOnTenTMasterSealHLM5000SL:183g/LMasterSealHLM5000S:190g/LMasterSealHLM5000R:180g/LMasterSealHLM5000T:132g/L

    HOW TO aPPLY MaSTeRSeaL HLM 5000SURFace PRePaRaTiOn

    1.Forbestresults,allconcretedecksurfacesshouldbelightlysteeltroweledtoaflat,uniformsurface.Alightbroomfinishisacceptable.newconcretemustbeproperlywatercuredatleast14days.Membranecuringcompoundsmustbemechanicallyremoved.

    Technical Data Guide

  • High-Build Standard System System

    Hardness,Shoreoo n/A 85 ASTMC836

    Viscosity, poise BrookfieldHLM5000SL 125HLM5000S 450HLM5000R 800HLM5000T 4,000

    Tensile strength, psi(MPA) 200(1.4) 150(1.0) ASTMd412

    average elongation, % 3001 600 ASTMd412

    100% modulus,psi(Mpa) 80(0.6) 80(0.6) ASTMd412

    Moisture-vapor permeability, 0.075 0.1 ASTMe96dryperms

    crack bridging test, Passed1/4"; Passed116"; ASTMC836cycled10timesper nolossofbondor nolossofbond24hoursat15F(-9C) orcrackingexhibited orcrackingexhibited

    extensibility after heat aging nocracking ASTMC836

    adhesion in peel,lbs/in 5 ASTMC836(1lb/inminimum)

    Weight loss, %(20%max) 16 ASTMC836

    Resultsshownaretypicalbutarenotintendedasperformancecriteriaforon-siteinstalledmaterial.1Testedindirectionofgreatestelongationoffabric

    elongation, % ASTM5034Machinedirection 54Crossdirection 147

    grab breaking, lbs ASTM5034Machinedirection 54Crossdirection 32

    Mullen burst,psi 70

    Weight,lbs/ft250mil 0.188120mil 0.428

    Burst strength,psi(MPa) 175 ASTMd2529

    Puncture resistance,in-lbs 45 ASTMd781

    Testresultsareaveragesobtainedunderlaboratoryconditions.Reasonablevariationscanbeexpected.

    Test Data

    PRoPeRTy VALue

    PRoPeRTy VALue

    Typical Properties

    Minimum recovery,% 90

    Swelling in water, nil3daysatroomtemperature

    Service temp. range, F(C)Minimum -40(-40)Maximum 120(49)

    Width,inMinimum 371/2Maximum 381/2

    Length,ft 300

    Thickness,in (FTM-5136)0.024(-0.0,+0.002)

    nominal weight,oz/yd2 2.13

    construction,in2 34by30

    Yarn denier 70

    PRoPeRTy ReSuLTS TeSTMeTHod

    PRoPeRTy ReSuLTS TeSTMeTHod

    PRoPeRTy ReSuLTS TeSTMeTHod

    HLM5000

    HLM5000(self-levelinggrade)

    MasterSeal995

    MasterSeal977

    MASTeRSeAL995

    Technical Data compositionMasterSealHLM5000isabitumen-modifiedpolyurethane.

    compliancesASTMC836nationalstandardofCanada37.58-M86developedbyCGSB

    TechnicaldataGuideMasterSeal HLM 5000

  • VenT,dRAinPiPe,AndPoSTPeneTRATionSCleanmetalsurfacestobrightmetalandprimewithaqualityrust-inhibitingmetalprimerfollowedbyMasterSealP173orP176.Removedust,debrisandanyothercontaminantsfromvoids.Sealwiththeappropriatesealant.

    aPPLicaTiOnAtestapplicationisalwaysrecommendedbeforeproceedingwithentireapplication.noTe:Finishcoatmustbeappliedinapinhole-free,continuousmembraneforwaterproofingintegrity.

    STAndARdSySTeM1.SelectthegradeofMasterSealHLM5000thatbestmeetsindividualjobrequirements.useMasterSealHLM5000Tfortrowelapplication,MasterSealHLM5000Sforsprayapplication,MasterSealHLM5000RforrollerapplicationorMasterSealHLM5000SLforsqueegeeapplication.

    2.Forhorizontalapplications,emptycontentsofpailandspreadimmediatelytoensureworkability.Bestresultsareobtainedbymarkingoff125ft2(11.61m2)areasandevenlyspreadingthecontentsofa5gallon(18.93L)unitwitharubber-edgednotchedsqueegee.Repeattheaboveprocedureuntiltheentiresurfaceiscovered.

    3. Forverticalapplications,applybytrowel,rollerorsprayattherateof25ft2/gallon(0.6m2/L).Bestresultsareobtainedbymarkingoff125ft2

    (11.6m2/L)andevenlyapplyingthecontentsofa5gallon(18.93L)pail.

    4.Verifytheappliedthicknesswithawetmilgaugeastheworkprogresses.

    5.Theintegrityofthecuredmembraneonahorizontalsurfacemaybeverifiedbydammingtheentireareaandfloodingwithwatertoaminimumdepthof2"(51mm)andallowingthewatertostandfor2448hours.Visuallyinspectthebottomsurfacetocheckforanywaterpenetration.ifrepairsarenecessary,theareashouldbedrainedandallowedtodrybeforereapplyingMasterSealHLM5000.Afterreapplication,theareashouldbetestedagainformembraneintegrity.

    HiGH-BuiLdSySTeMConcreteapplication:Apply60wetmilsofMasterSealHLM5000,followedbysettingMasterSeal995reinforcingfabricintothewetmaterial.overlapallseamsaminimumof3"(76mm).Additionalmaterialmayberequiredtoproperlyembedthereinforcingfabricwhereitoverlaps.Allowthefirstcoattocureovernightandfollowwithasecond60wet-milapplicationofMasterSealHLM5000.

    Plywoodapplication:AllplywoodconstructionmustcomplywithAPA(AmericanPlywoodAssociation)standards.CaulkalljointswithaMasterBuildersSolutionssealantandthenproceedwiththeMasterSealHLM5000high-buildsystem.

    SPRAyequiPMenTForsprayequipmentrecommendations,consulttheequipmentmanufacturer.

    cURingAppreciablepropertiesdevelopwithin2448hoursat75F(24C)and50%relativehumidity.ProtectMasterSealHLM5000fromtrafficduringcuring.

    DRainage anD PROTecTiOn1.Forprotectionduringbackfillandwherehydrostaticpressureisanticipated,usetheappropriateMasterSeal975drainBoardSystemforinstallationinstructions.

    2. Forprotectionduringbackfillonly,installprotectionboardassoonaspossiblefollowingcureofMasterSealHLM5000.

    cLean UPCleanalltoolsandequipmentimmediatelyafterapplicationwithMasterSeal990.

    HOW TO aPPLY MaSTeRSeaL 977SURFace PRePaRaTiOn

    1.Waterproofingmembranesmustbeprotectedagainsttear,puncture,andotherabusesduringplacementofconcretewearingslabsandreinforcingsteel.Theyshouldalsobeprotectedfromjobsitetrafficandbackfillingoperations.

    2.Allspecificationscallingformembranewaterproofingshouldalsorequireprotectionofmembraneasanintegralpartoftheoverallwaterproofingsystem.

    2.Forextremelyporousblock:PrimewithacoatofMasterSealHLM5000dilutedupto25%withMasterSeal990orxylene.orapplyapargecoatofMasterSeal581attherateofapproximately400ft2(37.2m2)perbagandallowtocureaminimumof7daysbeforeapplyingMasterSealHLM5000.

    3.Removedust,dirtandothercontaminantsjustbeforeorduringapplication.Surfacesmustbedryatthetimeofapplication.

    4.Air-voidpockmarksorhoneycombsmustbeopeneduptoallowMasterSealHLM5000tofillthecavitiescompletely.Airentrapmentwithinvoidsmaycauseblisters.extremecasesmayrequireadditionalrepair.

    PReSTRiPing1.Beforeapplyingthefinalmembrane,alljoints,cracksandopeningsaroundprotrusionsmustbesealedbycaulkingorprestriping(apreliminarycoatingofMasterSealHLM5000appliedwithatrowelorstiff-bristledbrush).Allowtodryovernightbeforeapplyingfinalmembrane.

    2.Whenthefinalmembraneisapplied,theoverallthicknessoverjointsandcracks,atcovesandaroundpenetrationsshouldbeapproximately100wetmils(2.5mm)onthestandardsystem.

    STATiCJoinTSAndCRACkSJointsandcrackslessthan116"

    (1.6mm)should

    befilledbyprestriping.Applymaterialsoitbothfillsandoverlapsthejointorcracktoawidthof4"(102mm)oneachside.

    WoRkinGoRexPAnSionJoinTSAlljointsover18"(3mm)mustbesealedwithaMasterBuildersSolutionsurethanesealant.Anyworkingjointlessthan18"(3mm)shouldberoutedtoaminimumof1/4"(6mm)andfilledwithasealant.Preventthewaterproofingmembranefromadheringtothejointsealant,whichcouldcausesealantormembranefailure,byapplyingacoatofwaxorbondbreakertapeoverthecuredsealantandthenprestriping.

    unCoATedMeTALSuRFACeSRemovedust,debris,andanyothercontaminantsfromvent,drainpipeandpostpenetrations,regletsandothermetalsurfaces.CleansurfacestonearwhiteperSSPC-nACe2andprimeimmediatelywithMasterSealP173.ProvideappropriatecantwithMasterSealnP1

    ornP2sealantstoeliminate90angles.

  • aPPLicaTiOninstalloverlappingMasterSeal977protectionboardassoonaspossiblefollowingcureoftheliquidmembrane.ProtectMasterSealHLM5000fromtrafficbeforeplacementofprotectionboard.MasterSealHLM5000mustbecuredbeforeinstallationofanytopping.

    FOR BeST PeRFORManceMASTeRSeALHLM5000

    ApplyMasterSealHLM5000whensubstratesaredryandairtemperaturesare40to90F(4to32C);forapplicationattemperaturesbelow40F(4C),consultTechnicalServices.

    TemperaturesinfluenceviscosityandhandlingcharacteristicsofMasterSealHLM5000:heatincreasesandcolddecreasestheflow.keepMasterSealHLM5000coolinhotweatherandwarmincoldweather.

    Avoidapplicationwheninclementweatherispresentorimminent.

    donotapplytoreinforcingbarsortowetorcontaminatedsurfaces.

    donotdirectlyheatcontainerswithflame,stove,hotplateoroven.

    PatchallvoidsanddeepdepressionsinsubstrateswithappropriatepatchingmaterialbeforeapplyingMasterSealHLM5000.

    useMasterSeal550underthin-settileapplications.BeforeapplyingMasterSealHLM5000,damalldrainsanddrainopenings.

    Carefullyworkmaterialoverirregularconcretetoavoidpinholesandholidays.

    ProtectMasterSealHLM5000coatedsurfacesfrompuncturewithprotectionboarduntilrequiredtoppingorbackfillisplaced.

    notintendedasanexposedorwearingsurface.donotusewhereasolventodorisobjectionable,e.g.,nearareaswherefoodpreparationorprocessingoccurduringtheapplication.

    SpecifywetorpapercuringforconcretetobecoatedwithMasterSealHLM5000;avoidusingliquidcuringcompounds.

    inhorizontalapplicationsconcretemustbesloppedtodraintoavoidpondingwateronthesurfaceofMasterSealHLM5000

    WhenusingdrainagematdirectlyoverMasterSealHLM5000,alayerof6milpolyethylenesheetingshouldbeusedbetweentheMasterSealHLM5000andthedrainagemat.

    MASTeRSeAL977StoreMasterSeal977onaflatsurfaceandkeepitdry;donotremoveshrinkwrapuntilimmediatelybeforeuse.

    ifboardisexposedtoprolongedperiodsofwaterimmersionorexcessivehumidity,itmaycurlorwrinkle.

    MasterSeal977tobecoveredwithaconcretewearingcoursemustbesecurelyattachedtomembrane.

    GeneRALProperapplicationistheresponsibilityoftheuser.FieldvisitsbyBASFpersonnelareforthepurposeofmakingtechnicalrecommendationsonlyandnotforsupervisingorprovidingqualitycontrolonthejobsite.

    HeaLTH, SaFeTY anD enViROnMenTaLRead,understandandfollowallSafetydataSheetsandproductlabelinformationforthisproductpriortouse.

    LiMiTeD WaRRanTY nOTice BASFwarrantsthisproducttobefreefrommanufacturingdefectsandtomeetthetechnicalpropertiesonthecurrentTechnicaldataGuide,ifusedasdirectedwithinshelflife.Satisfactoryresultsdependnotonlyonqualityproductsbutalsouponmanyfactorsbeyondourcontrol.BASFMAkeSnooTHeRWARRAnTyoRGuARAnTee,exPReSSoRiMPLied,inCLudinGWARRAnTieSoFMeRCHAnTABiLiTyoRFiTneSSFoRAPARTiCuLARPuRPoSeWiTHReSPeCTToiTSPRoduCTS.ThesoleandexclusiveremedyofPurchaserforanyclaimconcerningthisproduct,includingbutnotlimitedto,claimsallegingbreachofwarranty,negligence,strictliabilityorotherwise,isthereplacementofproductorrefundofthepurchaseprice,atthesoleoptionofBASF.Anyclaimsconcerningthisproductmustbereceivedinwritingwithinone(1)yearfromthedateofshipmentandanyclaimsnotpresentedwithinthatperiodarewaivedbyPurchaser.BASFWiLLnoTBeReSPonSiBLeFoRAnySPeCiAL,inCidenTAL,ConSequenTiAL(inCLudinGLoSTPRoFiTS)oRPuniTiVedAMAGeSoFAnykind.

    Purchasermustdeterminethesuitabilityoftheproductsfortheintendeduseandassumesallrisksandliabilitiesinconnectiontherewith.ThisinformationandallfurthertechnicaladvicearebasedonBASFspresentknowledgeandexperience.However,BASFassumesnoliabilityforprovidingsuchinformationandadviceincludingtheextenttowhichsuchinformationandadvicemayrelatetoexistingthirdpartyintellectualpropertyrights,especiallypatentrights,norshallanylegalrelationshipbecreatedbyorarisefromtheprovisionofsuchinformationandadvice.BASFreservestherighttomakeanychangesaccordingtotechnologicalprogressorfurtherdevelopments.ThePurchaseroftheProduct(s)musttesttheproduct(s)forsuitabilityfortheintendedapplicationandpurposebeforeproceedingwithafullapplicationoftheproduct(s).Performanceoftheproductdescribedhereinshouldbeverifiedbytestingandcarriedoutbyqualifiedexperts.

    TechnicaldataGuideMasterSeal HLM 5000

  • Dynamic crack Detail

    asphalt Pavement Topping/expansion Joint

    Vent/Drain/Pipe/Post Penetration Detail

    Split Slab with cant DetailWaterproofing at Bi-Level Drain

  • inside corner Detail (Static)

    Waterproofing Foundation Walls

    expansion Joint Detail

    Static crack/Prestripe Detail

    = Registered Trademark of BASF Group in many countries of the world

    BASF Chemicals & Polymers Pakistan (Pvt) Ltd. Construction Chemicals Division 46-A,Block-6, P.E.C.H.S., Shahrah-e-Faisal, Karachi-75400

    email: [email protected]

    Karachi Tel: 021 111 550 550 Lahore Tel: 042 111 550 550 Islamabad Tel: 051 4446106-08

    Website: www.master-builders-solutions.basf.pk

    TechnicaldataGuideMasterSeal HLM 5000