The 18V32 GD Dual Fuel Cogeneration
Power Plant has been installed on site
since new. The operational facility
specially ordered the power plant from
Wartsila Finland because of its unique
capability to operate on both Natural
Gas & Heavy Fuel Oil.
The power plant has run the last 8-10
years on Natural Gas because of country
regulations.
![Page 4: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/4.jpg)
The Wartsila 18V32 GD Power Plant has
been very well maintained by OEM since
new. Because the facility could not allow
any down time to occur, anything the
plant required was implemented
immediately.
Since maintenance overhaul, the plant
has run only 1 hour and is on standby
mode, ready for a test run at the time of
inspection.
![Page 5: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/5.jpg)
Even though the total lifetime hours are
on the high side, you would not know it,
as the plant is in good condition
internally and externally. The plant has
plenty of lifetime hours left to generate
power for another facility.
All Power Plant Equipment and Spares
are included in this package.
![Page 6: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/6.jpg)
Plant Type: Cogeneration
Manufacture: Wartsila
Model: 18V32GD
Power Output: 6300 KW (6.3 MW)
Year: 1995
Fuel: Natural Gas & Heavy Fuel Oil
Generator Manufacture: ABB
Generator Output: 7885 KVA
Voltage: 15000 Volts
Frequency: 50 HZ
![Page 7: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/7.jpg)
Total Hours: 10930
Hours at Maintenance Overhaul: 100,929
Hours Run Since Maintenance: 1 Hour
![Page 8: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/8.jpg)
Boiler Manufacture: A ALBORG BOILER
Compressor Manufacture: Sperre
Compressor Capacity: 30 bar
Gas Compressor Manufacture: LMF
Gas Compressor Output: 345 KW
L/O Separator Manufacture: Alfa Laval
F/O Separator Manufacture: Alfa Laval
L/O Cooler Manufacture: Alfa Laval
L/O Cooler Capacity: 193.61
![Page 9: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/9.jpg)
L/O Heater Manufacture: Alfa Laval
L/O Heater Capacity: 381.41
H/T Heater Manufacture: Alfa Laval
H/T Heater Capacity: 178.2
L/T Cooler Manufacture: Alfa Laval
L/T Cooler Capacity: 335.01
H/T Cooler Manufacture: Alfa Laval
H/T Cooler Capacity: 107.8
![Page 10: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/10.jpg)
(1) Engine
(1) Generator
(1) Boiler
(2) Compressor
(1) Gas Compressor
(1) L/O Separator
(1) F/O Separator
(1) L/O Cooler
![Page 11: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/11.jpg)
(1) L/O Heater
(1) H/T Heater
(1) L/T Cooler
(1) H/T Cooler
(2) F/O Tank (10 Ton each)
(3) F/O Tank (10 Ton each)
(1) D/O Tank (10 Ton)
(1) F/O Tank (270 Ton)
![Page 12: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/12.jpg)
![Page 13: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/13.jpg)
![Page 14: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/14.jpg)
![Page 15: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/15.jpg)
![Page 16: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/16.jpg)
Wartsila 18V32 GD Engine & Generator Installed On Site
![Page 17: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/17.jpg)
ABB Generator 7885 KVA
![Page 18: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/18.jpg)
View of Top of Engine Front of Boiler
![Page 19: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/19.jpg)
![Page 20: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/20.jpg)
![Page 21: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/21.jpg)
![Page 22: 6750 KW Wartsila 18V32 GD Cogeneration Power Plant...The Wartsila 18V32 GD Power Plant has been very well maintained by OEM since new. Because the facility could not allow any down](https://reader036.vdocuments.mx/reader036/viewer/2022062610/611df04bed1b1615f16ccc1a/html5/thumbnails/22.jpg)
Phillip Brown
Tel: 954-800-4289 Email:
Rose Email: