Outcome 1Electrical supplies used in domestic plumbing services
Unit 202: Electrical principles and processes for building services engineering
![Page 2: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/2.jpg)
Domestic electrics• BS7671 (design installation and testing)• The Electricity at Work Regulations• IET Wiring Regulations 17th edition• IET on-site guide• Approved Document part P (Building Regulations)• Manufacturer’s instructions.
![Page 3: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/3.jpg)
Low voltage: • 230v single phase AC• 110v single phase AC
Extra low voltage for safety:• 24v DC• 18v DC• 12v DC
Domestic electrics
![Page 4: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/4.jpg)
Domestic electricsUnder this regulation you do not, as a plumber, have to be Part P qualified to replace a like-for-like component, unless it is in a danger zone, when you need to be Part P registered.
For an installation, you need to be a fully qualified electrician.
A danger zone is within a bathroom, kitchen or outhouse. If an airing cupboard door is on the landing, that is not a danger zone, but if it is in the bathroom, it is a danger zone. If the boiler is in the loft, it is fine; in the kitchen it is not. To replace parts on these items in these locations, you need to be a Part P qualified plumber.
![Page 5: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/5.jpg)
Domestic electricsElectricity is used in many plumbing situations:•Pumps•Showers•Programmers•Thermostats•Immersion heaters•Plugs/spurs•Boilers•Cookers
![Page 6: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/6.jpg)
Domestic electricsElectricity is a form of energy, and is produced in a variety of ways:
•Friction between materials can create static electricity•Heat can produce electricity when applied to dissimilar metals; thermocouple•Pressure acting on certain types of crystals; piezoelectric sparkers•Coils being rotated within a magnetic field•Generation of electricity by whichever means results in a flow of electrons which will travel along a conductor.
![Page 7: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/7.jpg)
Domestic electricsAC = alternating current = mains electricity (electromagnetically)www.sciencejoywagon.com/physicszone/otherpub/wfendt/generatorengl.htm
This shows the sinusoidal wave formHz = cycles per second = 50Hz in UK
![Page 8: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/8.jpg)
Domestic electricsDC = direct current = batteries (chemically)
• Dissimilar metals in a dilute acid solution• Cathode eats away at the anode
coppercathode(positive)
ammeter dilutesulphuric acid
zinc anode(negative)
![Page 9: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/9.jpg)
Domestic electricsIn a domestic property:
•Sockets are 240v single phase AC•Use a step-down transformer for 110v single phase AC•May also use battery operated tools, which will be 24v, 18v or 12v DC.
240v 110v Step down transformer
Battery operated
![Page 10: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/10.jpg)
Domestic electricsDedham: Electrocuted builder’s death was an accidentFather-of-three, Paul Hamlyn, 44, of Chase Road West in Great
Bromley, was killed when he touched a live cable at a house in Forge Street, Dedham.
“We had the toilet macerator changed about six or eight weeks ago and the plumber had put it on a normal plug and not re-wired it back into the fuse box,” the customer said.
“Paul said he knew someone who could do any electrical work if it needed doing – I can’t think why he moved the wire. I think he was reaching for his tool box.”
A post-mortem at Colchester General Hospital concluded that the victim had died of electrocution.
NELSON, A. (2011) Dedham: Electrocuted builder’s death was an accident. East Anglia Daily Times. 14th January. Available from: http://www.eadt.co.uk/news/dedham_electrocuted_builder_s_death_was_an_accident_1_774724 [Accessed 25th January 2013].
![Page 11: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/11.jpg)
Domestic electricsLighting circuit:
Radial circuit:Be careful when going into wall and ceiling
Consumer unit
Lights
![Page 12: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/12.jpg)
Domestic electricsRing main: (sockets)
Be careful when drilling into walls and floors.
Consumer unit
![Page 13: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/13.jpg)
Domestic electricsLighting circuit: Radial circuit
1.5mm twin and earth6 amp circuit protectionOne circuit upstairs and one downstairs
Ring main: Ring circuitSockets2.5mm twin and earth32 amp circuit protection (consumer
unit)13 amp appliance protection (plug)
![Page 14: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/14.jpg)
Domestic electricsMicro circuit breaker (MCB) protection of circuits
Lighting 6 ampImmersion 16 ampWater heater 16 ampRing main 32 ampCooker 32 amp
![Page 15: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/15.jpg)
Domestic electricsAs plumbers, we are not allowed to interfere with either the ring main or lighting circuit.
•Only a qualified electrician – competent person•We can attach an appliance from a fused spur.
![Page 16: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/16.jpg)
Domestic electricsConsumer unit•Found where the electrics enter the property•Contains all MCBs, residual current device, RCDs and main isolator•Where the single source is divided into multiple circuits.
MCBsRCDs
Main isolator
![Page 17: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/17.jpg)
Domestic electricsConsumer unitIf an MCB needs replacing, the main isolator in the consumer unit would have to be isolated while an electrician replaced the item.
MCBs Main isolator
![Page 18: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/18.jpg)
Domestic electrics• Mains supply• Suppliers fuse• Meter• Consumer unit• Feeds the circuits
Earth barUp to the meter is the
responsibility of the supplier. From the consumer unit
onward is the responsibility of homeowner.
![Page 19: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/19.jpg)
Domestic electricsCentral heating S plan
Wire in from switched fused spur:• Programmer• Cylinder thermostat• Room thermostat• Boiler• Pump• 2 x two port valves
![Page 20: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/20.jpg)
Domestic electricsCentral heating Y plan
Wire in from switched fused spur:• Programmer• Cylinder thermostat• Room thermostat• Boiler• Pump• 1 x three port valve
![Page 21: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/21.jpg)
Domestic electricsEarthing to keep us safe from electric shocks:
TNS from armoured cable
![Page 22: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/22.jpg)
Domestic electricsEarthing to keep us safe from electric shocks:
TNCS from neutral
![Page 23: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/23.jpg)
Domestic electricsEarthing to keep us safe from electric shocks:
TT from earth rod or electrode
![Page 24: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/24.jpg)
• Correct earthing is very important, as the majority of electric shocks and electrocutions are due to incorrect earths or earthing faults
• Any problems should always be reported to the customer.
Domestic electrics
![Page 25: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/25.jpg)
Domestic electricsMiniature circuit breakers (MCB):•Found in the consumer unit and protect one appliance or circuit •Trip out if an overload is detected.
![Page 26: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/26.jpg)
Domestic electricsResidual circuit breakers (RCD):• Found in modern consumer units • Trip out if there is an earth fault (test and re-set switch)• Plug-in RCDs should be used with 240v tools.
Trip at 30ma
![Page 27: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/27.jpg)
Domestic electricsResidual current breaker with overload (RCBO):•This is located in the consumer unit and contains the MCB and RCD for one appliance or circuit •Can be used to bring older circuits up to current standards.
![Page 28: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/28.jpg)
Domestic electricsFuses and MCBs are there to protect the circuit and appliance. If an appliance or circuit is overloaded, the insulation in the cable is the first item to get damaged and possibly burnt.
The fuse inside a fused spur will protect the cable and appliance.
Any visual faults need to be reported to the homeowner or your supervisor for them to make a decision.
![Page 29: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/29.jpg)
Domestic electrics• Cartridge fuses are the older type of circuit protection
and are re-wireable• Plug tops have cartridge fuses inside.
![Page 30: 6035 l2u202 ppt_outcome1](https://reader035.vdocuments.mx/reader035/viewer/2022062302/58ce7a9f1a28abdc578b76c5/html5/thumbnails/30.jpg)
Domestic electrics• All circuits and appliances must be protected by the use
of a fuse or MCB. Modern regulations also require the use of an RCD
• Every circuit and appliance must also have a means of isolation
• Permanent de-commissioning is done at consumer unit• Temporary de-commissioning can be done at appliance.