6-81-1052 rev 2
TRANSCRIPT
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 1/7
tal l tuOINDIA U M I T E DIxRn IA Goff of AM Oneidaloo9I
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IR E ALAR M CAB LE S
STANDARD SPECI F I CATI ON NO.
6-81-1052 Rev.2
Page 1 o f 7
Inv< stIR-
Wiarurr f ieTur
INSPECTION AND TEST PLAN
FORCOMMUNICATION AND
FIRE ALARM CABLES
ps
2 29.06.2012 Revised and Re issued R K P K C DM
1 28.09.07 Revised and Re- i ssued AK G P P M M V K K VC
0 30.04.02 Issued for implementat ion R G AK C AK B G R R
S tanda rds C om m i t tee Standards Bureau
Rev.No .
Date P u r p o s ePrepared
byChe cke d
byC o n v e no r C ha irma n
A p p roved by
Copyright EIL— All r ights reservedFormat N o. 8-00-0001-F7 Rev. 0
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 2/7
18i i2-43eg d i ti E N G I N E E R Srzir taRterew INDIA LIMITED(A Govl d Inds uncienaiong)
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IR E ALAR M CAB LE S
S T A N D A R D S P E CIF ICA T ION N O .
6-81-1052 Rev. 2
Page 2 of 7
Abbreviations
AS
BASEEFA
BI S
CCE or CCOE
CELL
CIMFR
C E
DFTDT
DPT
ERTL
FCRI
FMFLP
HT
HI CITPIP
IC
IG C
IE C
JEC
LPT
Alloy Steel
British Approval Service for Electrical Equipment n Flammable
Atmospheres
Bureau of Indian Standard
Chief Controller of Explosives
Certification Engineers International Limited
Central Institute of Mining & Fuel Research
Carbon Equivalent
Dry Film Thickness
Destructive Testing
Dye Penetrate Testing
Electronics Regional Test Laboratory
Fluid Control Research Institute
Factory MutualFlame Proof
Heat Treatment
Hydrogen Induced Cracking
Inspection and Test Plan
Ingress Protection
Inspection Certification
Inter Granular Corrosion
International Electro technical Commission
Japanese Electro technical Committee
Liquid Penetrate Testing
MPT/MT
MRT
MTC
MO C
NPSH
NDT
NEMA
PD
PO
PESO
PQR
PR
PMIPV C
QC
TCTPI or TPIA
UT
UL
VDR
WPS
WPQ
XLPE
Magnetic Particle Testing
Mechanical Run Test
Material Test Certificate
Material of Construction
Net Positive Suction Head
Non Destructive Testing
National Electrical Manufacturers Association
Partial Discharge
Purchase Order
Petroleum Explosive Safety Organization
Procedure Qualification Record
Purchase Requisition
Positive Material IdentificationPoly Vinyl Chloride
Quality Control
Test Certificate
Third Party Inspection Agency
Ultrasonic Testing
Under writer Laboratories
Vendor Data Requirement
Welding Procedure Specification
Welders Performance Qualification
Cross Linked Poly Ethylene
Inspection Standards Committee
Convenor : Mr. A.K. Chaudhary
Members:
Mr. S.C. Gupta Mr. RK Singh Mr. MP Jain (Projects)
Mr. G. Suresh Mr. Rajeev Kumar Mr. G. Poomachandra Rao
Format No . 8-00-0001-F7 Rev. 0Copyright El L — A ll rights reserved
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 3/7
ISRIZIEteb ENGINEERS$gar &Reg W I F IN D I A L I M I T E D
e:Ragea,
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IRE ALAR M CAB LE S
S T A N D A R D S P E CIF ICA T ION N O .
6-81-1052 Rev. 2
Page 3 of 7
1.0 SCOPE
This Inspection and Test Plan covers the minimum testing requirements of flame retardant type PVC sheathed cables for use in Plant communication, Fire Alarm
systems and Jelly filled telecommunication cables.
2.0REFERENCE DOCUMENTS
PO/PR/ Standards referred there in/Job specifications/Approved documents.
3.0 INSPECTION AND TEST RE UIREMENTS
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM
OF CHECKRECORD
SCOPE OF INSPECTION
SU BEIL/TPIAUPPLIER
SUPPLIER
1.0 Procedures -- -- -- -- -- --
2 .0 Material Inspection
2. 1
Incoming raw material like
Copper Aluminium, PVC,
PE, Jelly Compound,
Armour material, etc.
Dimensional, Purity, Physical, Chemical
Properties, Tests on jelly compound as per
DOT spec.Sample
Sub supplier
TC/Supplier's
Test Records/
Third party Lab
H H R
3.0 In process Inspection
3. 1 Manufacturing StageDimensions at various stages, Spark test, Stage
Inspection100%
Supplier's Test
Records- H R
4.0 Final Inspection
Final Inspection on
Visual, Drum details, Size, Ends Capping,
Drums Condition, Marking on outer sheath(such as incremental length, voltage grade,
100% by
r and onu pp lieInspection
4. 1completed cable
manufacturer's name and for jelly filled cables
marking as per DOT spec), Colour coding of
cores, etc.
random basis
by EIL/TPIA
Witness
Record
- H H
Format No. 8-00-0001-F7 Rev. 0Copyright El L — A ll rights reserved
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 4/7
afteir a b - E N G I N E E R S
$1g73 1 faRegleNDIA LIMITEDon En a e on, timninil (AGovt Ins. UnSAISInf il
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IR E ALAR M CAB LE S
STANDARD SPECI F I CATI ON NO.
6-81-1052 Rev. 2
Page 4 o f 7
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM
OF CHECKRECORD
SCOPE OF INSPECTION
SU B
SUPPLIER EIL/TPIAUPPLIER
4 .2
Final Inspection oncompleted Cable(Jelly Filled
Cables)Acceptance Test
Dimension checks.
Check calibration status of all testing
equipment.
Test for insulation and sheath.
Continuity of conductors, absence of
crossed pairs and absence of contact
with poly-al tape
Continuity in poly-al tape
Colour coding
Conductor Resistance, Resistance
Unbalance in pair.Mutual capacitance (pair/average),
Capacitance Unbalance (pair to ground
and pair to pair)
Cross talk
Attenuation
Drip test
Dielectric Strength
Insulation Resistance
Conductor Annealing
Armour Galvanization
Overall finish and Drum length by re-winding
As per sampling
plan
1 or 2 drums perlot.
Inspection
Witness Record- H H
Format No. 8-00-0001-F7 Rev. 0Copyright EIL — All r ights reserved
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 5/7
INIRZIEgOli th ENGINEERS&eM P ' I N D I A L I M I T E D
INSPECTION AND TEST PLANFOR COMM UNICTION &
FIRE ALARM CABLES
STANDARD SPECI F I CATI ON NO.
6-81-1052 Rev. 2
Page 5 o f 7
SLNO .
STAGE/ ACTIVITY C HA R A C TER ISTIC SQUANTUMOF CHECK
R E C O R D
SCOPE OF INSPECTION
SU B
SUPPLIER EIL/TPIASUPPLIER
4. 3
Final Inspection on
Jelly Filledompleted Cable(
Cables)
Type Tests
Type tests on insulated conductors,
compatibility of Insulation and filling
compound as per DOT spec.
Type tests on Composite sheath and
Jacket as per DOT spec
Oxidation Induction test
Water Penetration test
Cable bend test.
One SampleSupplier's Test
Records- H R
4 .4
Final Inspection on
completed Cable( Non Jelly
Filled Cables )
Acceptance Test
Dimension checks
Continuity of conductors
Colour codeOverlap in poly-al tape and drain wire
resistance (if shielding specified)
Conductor Resistance.
Mutual capacitance (pair/average),
Capacitance Unbalance (pair to ground
and pair to pair) for communication
cables
Dielectric Strength
Insulation Resistance / Volume
Resistivity.
Tensile and Elongation (withoutageing)
As per sampling
plan
Inspection
Witness Record- H H
Conductor Annealing
Armour Galvanization
Tests on Insulation and sheath asper
IS 5831*
Format No. 8-00-0001-F7 Rev. 0Copyr ight El L - A l l r ights reserved
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 6/7
STANDARD SPECIFICATION NO.
lemma6-81-1052 Rev. 2
Page 6 o f 7
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IRE ALAR M CAB LE S
151fteialaiENONEERSIgar EVIesW I N D I A I J M I T E D
IA Govi of India utStalong)
SL
NO.STAGE/ ACTIVITY CHARACTERISTICS
QUANTUM
OF CHECKRECORD
SCOPE OF INSPECTION
SU B
SUPPLIERSUPPLIER EIL/TPIA
4. 5
Final Inspection on
completed Cable( Non Jelly
Filled Cables )
Special Test
Oxygen Index Test
Flammability test as per IS 10810 (Part
61 & 62)
Test for Rodent & termite repulsion
Surface finish and drum length check
by wiring
1 sample/Lot1 sample/Lot
1 sample/Lot
1 or 2 drums/Lot
Inspection
Witness Record- H H
4 .6
Final Inspection on
completed Cable( Non Jelly
Filled Cables )
Type Tests
Type test on conductor as per spec
Type tests on insulation and Sheath as
per specSample
Supplier's Test
Records- H R
5.0 Painting
6.0 Documentation and IC
6.1 Documentation and IC
Review of Internal Test Reports and MTCs.
• IC issuance-
Supplier's Test
Records /
Inspection
Certificate (IC)
.. H H
Format No. 8-00-0001-F7 Rev. 0Copyright EIL — All r ights reserved
7/28/2019 6-81-1052 Rev 2
http://slidepdf.com/reader/full/6-81-1052-rev-2 7/7
ENONEERSklflegier IN D IA L IM IT ED
(AGovlof Ind. undertalcoM
IN SPECTION A N D TEST PLA NF O R C O M M U N I C T IO N &
F IR E ALAR M CAB LE S
STANDARD SPECI F I CATI ON NO.
6-81-1052 Rev. 2
Page 7 o f 7
* - Thermal Stability, Hot deformation, Heat shock and Shrinkage tests on insulation and sheath shall be witnessed by EIL (One Sample/Lot), all other tests as
per IS-5831 shall be carried out by supplier and test reports shall be reviewed by EIL.
Legends: H- Hold (Do not proceed without approval), Random 10% , R-Review, RW-Random witness, W- Witness (Give due notice, work may
poceedaeschedueddae
NOTES (As applicable):Wherever W/R or H/W is indicated, Inspection Engineer shall decide the option to be exercised for the particular stage and supplier
In case of conflict between purchase specification, contract documents and ITP, more stringent conditions shall be applicable.
This document describes generally the requirements pertaining to all types of the item. Requirements specific to PO and the item are only applicable.
Acceptance Norms for all the activities shall be as per PO/PR/ Standards referred there in/ Job specifications /Approved documents
Format No. 8-00-0001-F7 Rev. 0Copyr ight EIL— Al l r ights reserved