EPC_08-114.indd 1 1/18/08 10:01:48 AM

Daikin has a worldwide reputation based on over 80 years’ experience in the successful

manufacture of high quality air conditioning equipment for industrial, commercial and

residential use. Daikin’s unique position as a manufacturer of air conditioning equipment,

compressors and refrigerants has led to its close involvement in environmental issues.

For several years Daikin has had the intention to become a leader in the provision

of environmental friendly products. This challenge demands the eco design and

development of a wide range of products and an energy management system; which

involves energy conservation and reduction of waste.

DAIKIN

02

EPC_08-114.indd 2 1/18/08 10:01:49 AM

Throughout the last 50 years or so the basic buildingblocks of life – air, water and the earth – havebeen systematically subjected to increasing levelsof pollution with little regard to their potentiallydevastating effects on future generations.

Recently however, concern has grown regardingclimate changes, acid rain, water and air pollutionand the constant degradation of Earth’s naturalresources. The very technology that created theseproblems is now being harnessed to halt andreverse them. Depletion of the ozone layer andglobal warming have been highlighted and are nowbeing addressed. Government legislation prohibitingthe use of toxic substances and the generation ofpollutants has slowed down the destruction of theenvironment.

Daikin Europe is proud to have been pro active inthis respect, closely following its Japanese parent inimplementing policies that have often pre-emptedofficial legislative codes and directives. As a result,

a culture of ‘environmental management’ has since2001, played a key role in the company’s day to dayactivities and development strategies.

Top management commitment is reflected in theestablishment of a number of action plans, which arenow strictly observed and implemented throughoutthe Daikin Group.

A number of ‘We Care’ icons are highlighted ingreen throughout the catalogue to indicate productfeatures that have an impact on reducing energyconsumption: Fan only, Night set mode, Economode, Energy efficiency, Movement sensor andHome leave operation.

ENVIRONMENTAL AWARENESS

Enhancing the present - safeguarding the future

03

EPC_08-114.indd 3 1/18/08 10:01:52 AM

MAIN

For end users:

Energy saving: increased EER up to 4.1

(energy label A)

Ensures maximum comfort

Sound pressure performance down to 43dB(A)

Wide operating range

Suits computer room applications (RZQ71-140)

24 hour programmable remote control with a

weekly schedule timer

Full range of indoor units: 8 different models in

35 different variants

For installers:

R-410A refrigerant

Re-use of existing R-22 or R-407C

piping possible (RZQ71-140)

Maximum piping length extended to 100m

Reduced weight and dimensions

The innovative Daikin Sky Air R-410A RZQ

Super Inverter, designed for use in shops,

restaurants and small offices, provides a

more comfortable environment and offers

substantial savings in energy consumption.

The RZQ Super Inverter enables Daikin to

offer a complete range (from 7.1 up to

24.1kW single and three phase versions) of

R-410A inverters from the smallest Split to

the largest VRV system.

The Super Inverter Range marks a major step

forward from the earlier R-407C system and

although it incorporates its predecessor’s

innovative features, it also possesses a

number of significant energy saving and

operating improvements of its own.

This system is supported by a full range of

Daikin indoor units, which may be used

as pairs or in twin, triple or double twin

combinations.04

EPC_08-114.indd 4 1/18/08 10:01:54 AM

4

3

2

1

0

RZQ

Based around Daikin’s well proven reluctance DC compressor motor technology, the RZQ Super Inverter delivershigh energy efficiency particularly in the mid to low settings, minimising annual electricity consumption and overallrunning costs. The system also offers improved EER up to 4.1 and COP up to 4.38.

The application of inverter control saves energy for two basic reasons:It enables compressor speedto vary according to thecooling/heating load andtherefore consumes only thepower necessary to matchthat load.

In partial load conditionsenergy efficiency is higher.

Inverter technology used in the RZQ Super Inverter ensures the highest comfort levels. The automatic controlof room temperature makes that the actual sensed temperature in the room is at pre set level, ensuring it isnever too cool or too hot.

This is a major improvement over standard fixed speed models, which utilise continuous on/off switching of thecompressor, creating greater fluctuations in room temperatures.

Inverter technology offers improved levelsof comfort:

Less frequent start/stop cyclesCapacity is automatically throttled back when setpoint is approachedStart-up time is reduced by 1/3

User comfort is further enhanced by the applicationof predicted mean value (PMV) control. PMV controladdresses the phenomenon whereby a person canfeel hot in summer and cold in winter at exactlythe same room temperature. PMV control sensesoutdoor temperature, as well as occupant andradiated heat levels and then sets and maintainsroom temperature at the most comfortable level.

››

CO

P

EER

COP Non InverterCOP Super Inverter

EER Non InverterEER Super Inverter

Outdoor unit kW Outdoor unit kW

* Indoor units used for this comparison: FCQ-C* Outdoor units used for this comparison: non inverter: RQ-B, Super Inverter: RZQ-B

Comparison between Super Inverter and Non Inverter: COP/EER

4

3

2

1

07.1 10.0 12.5

2.81 2.99 2.89

7.1 10.0 12.5

3.13

3.71 3.54

2.61 2.61 2.683.29

3.613.22

CREATING THE HIGHESTCOMFORT LEVELS

SAVING ENERGY CONSUMPTION

Temperature remains stable

Air conditioningwithout Inverter

Air conditioningwith Inverter

Slow start

05

EPC_08-114.indd 5 1/18/08 10:01:57 AM

RZQ

A. Reluctance DC compressorThe 71 class is equipped with a swing compressor.Friction and refrigerant leaks are suppressed and energy saving isimproved.

The 100-125-140-200-250 classes are equipped with a scroll compressor.The motor in the compressor is transferred from the low pressureside to the high pressure side. In this way superheat can be bettercontrolled, resulting in better performance.

swing compressor scroll compressor

Low pressureside

High pressureside

Suction

Scroll

Discharge

ReluctanceDC Motor

The piston which the bladeand the roller unified

Ref. Gas

Swing bush

Both the swing and scroll compressor are driven by the newly developed motor enabling better performance,higher energy efficiency resulting in high energy cost savings:

Using 4 neodymium magnets. These magnets are more powerful than the widely used ferrite types.›

Neodymiummagnet

Powerful magnets :Secret to raising energy-efficiency!

Ferritemagnet

ENERGY SAVING TECHNOLOGY

06

EPC_08-114.indd 6 1/18/08 10:02:06 AM

80

60

40

20

0200 300 400 500 600 700 800 900 1000

80

60

40

20

0200 300 400 500 600 700 800 900 1000

B. Sine Wave DC inverterGenerates smooth inverter waveforms to increase efficiency.

C. Fan motorThe DC fan motor offers substantial improvements in operating efficiency compared to conventionalAC motors, especially during low speed operation. Energy efficiency levels at low velocities in particular havebeen improved.

Rectangular wave

*Pulse Width Modulation

Sine wave PWM*

71 Type Motor Efficiency [%]

DC MOTOR

AC MOTOR

Revolutions [rpm]

Mot

orEf

ficie

ncy

[%]

D. I-demand function (optional adapter required: KRP58M51)The current sensor minimizes the difference between actual power consumption and the predefinedpower consumption. Maximum power consumption can freely be limited to 80 %, 70 %, 60 %, or 40 %of rated power input.

DC MOTOR

AC MOTOR

Revolutions [rpm]

Mot

orEf

ficie

ncy

[%]

Maximum limit ofpower consumption can be controlled

100/125/140/200/250 Type Motor Efficiency [%]

Pow

erC

onsu

mpt

ion

(kW

)

Time

8h 12h 16h 20h

07

EPC_08-114.indd 7 1/18/08 10:02:15 AM

RZQ

A. Re-use of existing piping without cleaning*A major installation advantage offered by the new system is its ability to connect to existing R-22 andR-407C piping without the need for pre-cleaning the pipe. This is the result of Daikin’s use of ether basedcompressor oils rather than the more commonly used moisture sensitive ester oils. Existing piping can bere-used subsequent to a simple pump down operation.

Benefits:Reduced installation timeReduced installation costNo filters needed

* For any further details, please refer to the installation manual

B. Longer piping length up to 100 mThe maximum length of the piping has been extended to 100 m, making installation easier for anyrequired layout.

›››

Max. piping length: 50m (class 71), 75m (class 100,125,140) and

100m (class 200,250)

Min. piping length: 5m (3m by field setting for class 71,100,125,140)

H = 75m

MAINTENANCEINSTALLATION AND

08

EPC_08-114.indd 8 1/18/08 10:02:30 AM

60

50

40

30

20

10

0

-10

-20

-30

Q71

-140

Q71

-140

C. Extended operating rangeThe ambient temperature operating range has beenextended to -15°C to 50°C in cooling and -20°C to15.5°C in heating for RZQ71-140. RZQ200-250 unitshave an operating range from -5°C to 46°C in coolingand -15°C to 15°C in heating.

D. Hand gripsFitted hand grips for easy transportation and installation.

E. Refrigerant recovery function (RZQ100,125,140,200,250C)The refrigerant recovery function enables the expansion valve to be opened. In this way the refrigerant canbe drained from the piping system.

F. Anti corrosion treatmentSpecial anti corrosion treatment of the heat exchanger provides 5 to 6 times more resistance against acidrain and salt corrosion. The provision of rust proof steel sheet on the underside of the unit gives additionalprotection providing the quality standard adapted by Daikin.

Operating range

46°CDB

15°CWB

-15°CWB-5°CDB

50°CDBCooling

-15°CDB

Heating

15.5°CWB

-20°CWB

IMPROVEMENT IN CORROSION RESISTANCECorrosion resistance rating

Non-treated Anti-corrosion treated

Salt corrosion 1 5 to 6

Acid rain 1 5 to 6

Heat exchanger

An anti-corrosion heat exchangercutaway view

Aluminium

Hydrophilic film

Corrosion-resistantAcrylic resin

G. Specially suited to computer room applications (EDP rooms)RZQ71-140 inverter units have been especially designed to guarantee cooling capacity at low indoor relativehumidity and operation limits down to 11°CWB making them suitable for EDP (Electrical Device Plant)room applications.

09

EPC_08-114.indd 9 1/18/08 10:02:40 AM

47

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50

100

520

RZQ

A. Low sound pressureReductions in outdoor unit sound pressure levels have beenachieved via:- redesigned fan blades and inlet bell mouth- a high efficiency aero spiral fan with backward curved

blade tips that reduce air turbulence and pressure loss- the redesigned bell mouth air inlet fitted with guide vanes

at the intake that also reduces air turbulence around the blades

Using the latest technology, sound pressure levels down to47 dB(A) in cooling (7.1 kW) are achieved. The sound pressurelevels of RZQ models are therefore up to 3dB(A) lower than thoseof standard fixed speed models.

B. Night quiet function: max. -5dB(A)During night time, sound level of the outdoor unit can be reduced fora certain period by limiting the maximum compressor frequency andfan speed: starting time and ending time can be set.

The night quiet function can be enabled according to end-userpreferences via 2 different modes:

Mode 1: automatic modeSet via the remote control. Time of maximum temperature ismemorized. The low operating mode will become active 8 hours*after the peak temperature in daytime and operation will return tonormal after 10 hours of low noise operation*.

Mode 2: customized modeStarting and ending times can be set by using an external timer control (optional adapter KRP58M51+ field supplied timer switch required for RZQ71-140).

* Notes: For factory settings: please refer to the service manual of these units or contact your local dealer.

Non Inverter: RQ

Super Inverter: RZQ

(standard)

Super Inverter: RZQ

(night quiet mode)

kW

dB

(A)

EXTREMELY QUIET OPERATION

Capacity %

Nightquietfunction

Standardoperationsound

Notes:This function is available in setting at site.The relationship of outdoor temperature (load)and time shown in the graph is just an example.

››

Night mode starts

Nightmodeends

external signal inputto KRP58M51

Load %

54

52

50

48

46

44

42

40

53

49

45

47

43

50

53

45

50Max.

-7dB(A)

Max.

-8dB(A)

Max.

-8dB(A)

7.1 10.0 12.5

10

EPC_08-114.indd 10 1/18/08 10:02:49 AM

BRC1D52

BRC7*

A. Infrared remote control

ON / OFFTimer mode start/stopTimer mode on/offProgramme timeTemperature settingAir flow directionOperating modeFan speed controlFilter sign resetInspection / test indication

B. Wired remote control

Real time clock: indicates real time and dayLimit operation (min/max): room temperature is controlled within adjustable upperand lower limits. Limit operation can be activated manually or by schedule timerSchedule timer:

It is possible to programme a weekly schedule timerIt is possible to programme 5 actions for each day of the week

Home leave (frost protection): during absence, the indoor temperature can bemaintained at a certain level. This function can also switch the unit ON or OFFDifferent levels of disabled buttons can be selected as follows:

Level 1: all buttons are accessibleLevel 2: all buttons are disabled except for: ON/ OFF, set temperature up/down,fan speed, cooling/heating mode, enable/disable schedule timer,air flow direction adjustment buttonLevel 3: all buttons are disabled except for: ON/ OFF, set temperature up/down,fan speed

››

››

SYSTEMS

INDOOR UNITS COOLING ONLY HEAT PUMP

FFQ-B BRC7E531 BRC7E530

FCQ-C BRC7F533F BRC7F532F

FCQH-C BRC7F533F BRC7F532F

FBQ-B - -

FDQ-B - -

FHQ-B BRC7E66 BRC7E63

FUQ-B BRC7C528 BRC7C529

FAQ71B BRC7E619 BRC7E618

FAQ100B BRC7C511 BRC7C510

11

EPC_08-114.indd 11 1/18/08 10:02:58 AM

The RZQ inverter can be connected to a wide range of indoor units to suite all possible tastes andapplications, including:

FFQ 4-way blow cassette (600x 600mm)FCQ(H) Roundflow ceiling mounted cassetteFBQ concealed ceilings unitsFDQ large concealed ceiling unitsFHQ ceiling suspended unitsFUQ 4-way blow ceiling suspended cassetteFAQ wall mounted units

All units can be combined for pair applications and twin, triple and double twin configurations

›››››››

OUTDOOR UNITS INDOOR UNITS

RZQ-B/C FFQ-B FCQ-C FCQH-C FBQ-B FDQ-B FHQ-B FUQ-B FAQ-B

PAIRAPPLICATION

RZQ71C - 71 71 71 - 71 71 71

RZQ100C/B - 100 100 100 - 100 100 100

RZQ125C/B - 125 125 125 125 125 125 -

RZQ140C/B - 140 140 140 - - - -

RZQ200C - - - - 200 - - -

RZQ250C - - - - 250 - - -

TWIN/TRIPLE/DOUBLE TWINAPPLICATION

RZQ71B 2 x 35 2 x 35 - 2 x 35 - 2 x 35 - -

RZQ100C/B2 x 50 2 x 50 - 2 x 50 - 2 x 50 - -

3 x 35 3 x 35 - 3 x 35 - 3 x 35 - -

RZQ125C/B

2 x 60 2 x 60 - 2 x 60 - 2 x 60 - -

3 x 50 3 x 50 - 3 x 50 - 3 x 50 - -

4 x 35 4 x 35 - 4 x 35 - 4 x 35 - -

RZQ140C/B

- 2 x 71 2 x 71 2 x 71 - 2 x 71 2 x 71 2 x 71

3 x 50 3 x 50 - 3 x 50 - 3 x 50 - -

4 x 35 4 x 35 - 4 x 35 - 4 x 35 - -

RZQ200C

- 2 x 100 2 x 100 2 x 100 - 2 x 100 2 x 100 2 x 100

3 x 60 3 x 60 - 3 x 60 - 3 x 60 - -

- 3 x 71 3 x 71 3 x 71 - 3 x 71 3 x 71 3 x 71

4 x 50 4 x 50 - 4 x 50 - 4 x 50 - -

RZQ250C- 2 x 125 2 x 125 2 x 125 2 x 125 2 x 125 2 x 125 -

4 x 60 4 x 60 - 4 x 60 - 4 x 60 - -

MODEL RANGE

INDOOR - OUTDOOR

12

EPC_08-114.indd 12 1/18/08 10:03:13 AM

FFQ25~60B

FFQ

FFQ-B

HEAT PUMP (air cooled)

Cooling capacity min~nom~max kW

Heating capacity min~nom~max kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions (HxWxD) unit mm

Weight unit kg

Air flow rate (H/L)cooling m3/min

heating m3/min

Sound pressure level (H/L)cooling dB(A)

heating dB(A)

Sound power level (H)cooling dB(A)

heating dB(A)

Power supply V1

Infrared remote controlcooling only

heat pump

Wired remote control

DECORATION PANEL

Dimensions (HxWxD) decoration panel mm

Weight decoration panel kg

FFQ35B FFQ50B FFQ60B

twin / triple / double twin application only

286 x 575 x 575

17.5

10 / 6.5 12 / 8 15 / 10

10 / 6.5 12 / 8 15 / 10

32 / 25 36 / 27 41 / 32

32 / 25 36 / 27 41 / 32

49 53 58

49 53 58

1~, 230V, 50Hz

BRC7E531

BRC7E530

BRC1D52

BYFQ60B55 x 700 x 700

2.7

Extremely compact casing (575mm in width and depth) enables the unitto fit flush into ceilings and match standard architectural modulesModern style decoration panel in white (RAL9010)Possibility to shut off one or two flaps for easy installation in cornersAutomatic air flow director ensures uniform air flow and temperaturedistributionExcellent low draught characteristicsExtremely quiet in operationSince the switch box is located inside the unit, it is easy to install andmaintain the cassette in any ceiling type or patternFurthermore the switch box can be reached by simply removing thesuction grill; therefore maintenance can be done very easily

›››

›››

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e ( 6 0 0 x 6 0 0 m m )

fan only

timer

energyefficiency

ceiling soilingprevention

self diagnosisdryprogramme

whisper quiet

infraredremote control

(optional)

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

fan speed2 steps

standard drainpump kit

twin/triple/double twinapplication

air filter

4 - W a y B l o w C e i l i n gM o u n t e d C a s s e t t e ( 6 0 0 x 6 0 0 m m )

13

EPC_08-114.indd 13 1/18/08 10:03:23 AM

FCQ-CR o u n d f l o w C e i l i n g M o u n t e d

C a s s e t t e

R o u n d f l o w C e i l i n g M o u n t e d C a s s e t t e

New attractively finished decoration panel in ‘fresh white’color (RAL9010)The thin body of the unit is the solution for customers requiring a compactunit for use with false ceilings360° air discharge ensures uniform air flow and temperature distributionAir discharge from the corners avoids dead zones that may be subject totemperature differencesComfortable horizontal air discharge ensures draught free operation andprevents ceiling soiling23 different air flow patterns enables the unit to be installed in corners orsmall roomsFresh air intake increased to 20% (with the optional fresh air intake kit)

››

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

whisper quietselfdiagnosis

dryprogramme

infraredremote control

(optional)

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

energyefficiency

timer ceiling soilingprevention

twin/triple/double twinapplication

multi modelapplication

fan only fan speed2 steps

air filter super multiplus

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions (H x W x D) unit mm

Weight unit kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level cooling dB(A)

Power supply VE

Infrared remote controlcooling only

heat pump

Wired remote control

DECORATION PANEL

Dimensions (H x W x D) decoration panel mm

Weight decoration panel kg

FCQ35C FCQ50C FCQ60C FCQ71C FCQ100C FCQ125C FCQ140C

twin / triple / double twin application only

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

2.11 2.77(V1) / 2.64(W1) 3.88 5.36

2.21 3.02(V1) / 3.14(W1) 3.95(V1) / 4.36(W1) 4.98(V1) / 5.69(W1)

3.36 3.61(V1) / 3.79(W1) 3.22 2.61

3.62 3.71(V1) / 3.57(W1) 3.54(V1) / 3.21(W1) 3.21(V1) / 2.81(W1)

A A A D

A A(V1) / B(W1) B(V1) / C(W1) C(V1) / D(W1)

1,055 1,385(V1) / 1,320(W1) 1,940 2,680

204 x 840 x 840 246 x 840 x 840

19 19 19 21 23 23 23

10.5 / 8.5 12.5 / 8.5 13.5 / 8.5 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 27.5 / 19.0

12.5 / 10.0 12.5 / 8.5 13.5 / 8.5 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0 27.5 / 19.0

31 / 27 31 / 27 33 / 28 33 / 28 37 / 32 41 / 35 41 / 35

31 / 27 31 / 27 33 / 28 34 / 28 37 / 32 41 / 35 42 / 35

49 49 51 51 54 58 58

1~, 220-240V, 50Hz / 60Hz

BRC7F533F

BRC7F532F

BRC1D52

BYCQ140C

50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950

5.5 5.5 5.5 5.5 5.5 5.5 5.5

14

FCQ-C

FCQ

EPC_08-114.indd 14 1/18/08 10:03:29 AM

FCQH-CH i g h C O P , R o u n d f l o w

C e i l i n g M o u n t e d C a s s e t t esuper multi

plus

The High COP FCQH series offers extremely high energy savingsNew attractively finished decoration panel in ‘fresh white’ color (RAL9010)The thin body of the unit is the solution for customers requiring a compactunit for use with false ceilings360° air discharge ensures uniform air flow and temperature distributionAir discharge from the corners avoids dead zones that may be subject totemperature differencesComfortable horizontal air discharge ensures draught free operation andprevents ceiling soiling23 different air flow patterns enables the unit to be installedin corners or small roomsFresh air intake increased to 20% (with the optional fresh air intake kit)

›››

››

H i g h C O P , R o u n d f l o w C e i l i n g M o u n t e d C a s s e t t e

infraredremote control

(optional)

fan only fan speed2 steps

air filter whisper quietselfdiagnosis

dryprogramme

energyefficiency

timer ceiling soilingprevention

twin/triple/double twinapplication

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions (H x W x D) unit mm

Weight unit kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level cooling dB(A)

Power supply VE

Infrared remote controlcooling only

heat pump

Wired remote control

DECORATION PANEL

Dimensions (H x W x D) decoration panel mm

Weight decoration panel kg

FCQH71C FCQH100C FCQH125C FCQH140C

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

1.98 2.66(V1) / 2.44(W1) 3.70(V1) / 3.54(W1) 4.64(V1) / 3.54(W1)

1.97 2.55(V1) / 2.56(W1) 3.57(V1) / 3.59(W1) 4.43(V1) / 3.59(W1)

3.59 3.76(V1) / 4.10(W1) 3.38(V1) / 3.53(W1) 3.02(V1) / 3.53(W1)

4.06 4.39(V1) / 4.38(W1) 3.92(V1) / 3.90(W1) 3.61(V1) / 3.90(W1)

A A A B(V1) /A(W1)

A A A A

990 1,330(V1) / 1,220(W1) 1,850(V1) / 1,770(W1) 2,320(V1) / 1,770(W1)

262 x 882 x 882 304 x 882 x 882

23 25 25 25

20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 32.5 / 21.5

20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 32.5 / 21.5

34 / 28 43 / 32 43 / 36 43 / 38

34 / 28 43 / 32 43 / 36 43 / 38

52 60 60 60

1~, 220-240V, 50Hz / 60Hz

BRC7F533F

BRC7F532F

BRC1D52

BYCQ140C

50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950

5.5 5.5 5.5 5.5

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

15

FCQH

FCQH-C

EPC_08-114.indd 15 1/18/08 10:03:42 AM

FBQ-B

FBQ100~140B

C o n c e a l e d C e i l i n g U n i t

C o n c e a l e d C e i l i n g U n i t

FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B FBQ140B

twin / triple / double twin application only

7.1 10.00 12.5 13.4

8.0 11.20 14.0 15.5

2.21 3.01(V1) / 2.86(W1) 3.97(V1) / 3.98(W1) 4.77(V1) / 4.76(W1)

2.13 2.99(V1) / 3.00(W1 3.98(V1) / 3.99(W1) 4.83(V1) / 4.82(W1)

3.21 3.33(V1) / 3.50(W1) 3.14 2.81(V1) / 2.82(W1)

3.76 3.75(V1) / 3.73(W1) 3.52(V1) / 3.51(W1) 3.21

A A B C

A A B C

1,105 1,500(V1) / 1,430(W1) 1,985(V1) / 1,990(W1) 2,385(V1) / 2,325(W1)

300 x 700 x 800 300 x 1,000 x 800 300 x 1,400 x 800

30 31 41 41 51 52 52

11.5 / 9 14 / 10 19 / 14 19 / 14 27 / 20 35 / 24 35 / 24

11.5 / 9 14 / 10 19 / 14 19 / 14 27 / 20 35 / 24 35 / 24

33 / 29 33 / 29 34 / 30 34 / 30 36 / 31 38 / 32 38 / 32

33 / 29 33 / 29 34 / 30 34 / 30 36 / 31 38 / 32 38 / 32

52 53 60 60 62 63 63

- - - 625 625 625 625

1~,230V,50Hz 1~,230V, 50Hz

BRCD1D52 BRC1D52

BYBS45D BYBS71D BYBS125D

55 x 800 x 500 55 x 1,100 x 500 55 x 1,500 x 500

3.5 4.5 6.5

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions (H x W x D) unit mm

Weight unit kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level cooling dB(A)

Drain-up height mm

Power supply VE

Wired remote control

DECORATION PANEL

Dimensions (H x W x D) decoration panel mm

Weight decoration panel kg

Lightweight and compactBlends unobtrusively with any interior décorOnly air suction and discharge grilles are visibleLeaves maximum floor and wall space for furniture, decoration and fittingsFits flush into each ceilingThe position of the individual air discharge grilles can be altered, enabling auniform temperature, even in irregularly shaped roomsThe maximum external static pressure (ESP) is 88Pa for FBQOptimum air distributionQuiet operation

››››››

›››

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

dryprogramme

wired remotecontrol

(optional)

centralisedremote control

(optional)

auto restart auto cooling/heating

changeover

fan only fan speed2 steps

air filter

whisper quietselfdiagnosis

energyefficiency

timer standard drainpump kit

twin/triple/double twinapplication

16

FBQ

EPC_08-114.indd 16 1/18/08 10:03:54 AM

FDQ-B

FDQ125B

FDQHEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions (H x W x D) unit mm

Weight unit kg

Air flow rate (M)cooling m3 / min

heating m3 / min

Sound pressure level (H)cooling dB(A)

heating dB(A)

Sound power level (H) cooling dB(A)

Power supply V3 / V1

Wired remote control

FDQ125B FDQ200B FDQ250B

12.5 20.0 24.1

14.0 23.0 26.4

4.15 6.23 8.58

3.69 6.74 8.22

3.01 3.21 2.81

3.79 3.41 3.21

B - -

A - -

2,075 - -

350 x 1,400 x 662 450 x 1,400 x 900

59 93 93

43 69 89

43 69 89

44 45 47

44 45 47

75 81 82

1~, 230V, 50Hz

BRC1D52

L a r g e C o n c e a l e d C e i l i n g U n i t

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

Slim design for flexible installationBlends unobtrusively with any interior décorIdeal for use in larger areasOnly air suction and discharge grilles are visibleThe position of the individual air discharge grilles can be altered,enabling a uniform temperature, even in irregularly shaped roomsOptimum air distributionQuiet operationThe external static pressure (ESP) ranges from 150 till 250Pa

›››››

›››

L a r g e C o n c e a l e d C e i l i n g U n i t

whisper quietwired remotecontrol

(optional)

centralisedremote control

(optional)

auto restartfan only fan speed2 steps

air filter selfdiagnosis

doublethermostatfunction

17

EPC_08-114.indd 17 1/18/08 10:03:59 AM

FHQ-B

FHQ71,100B

C e i l i n g S u s p e n d e d C a s s e t t e

The unit has a compact casingEasiest servicing in the marketThe ideal solution for shops, restaurants or offices without false ceilingsLeaves maximum floor and wall space for furniture, decoration and fittingsAutomatic air flow director ensures uniform air flow andtemperature distributionAir flow distribution pattern can be adapted to suit ceiling heights up to3.8m without loss of capacity

›››››

C e i l i n g S u s p e n d e d C a s s e t t e

FHQ35B FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B

7.1 10.0 12.5

8.0 11.2 14.0

2.46 3.3(V1) / 3.15(W1) 4.45

2.67 3.49(V1) / 3.60(W1) 4.36(V1) / 4.50(W1)

twin / triple / double twin application only 2.89 3.03(V1) / 3.17(W1) 2.81

3.00 3.21(V1) / 3.11(W1) 3.21(V1) / 3.11(W1)

C B C

D C(V1) / D(W1) C(V1) / D(W1)

1,230 1,650(V1)1,575(W1) 2,225

195 x 960 x 680 195 x 1,160 x 680 195 x 1,400 x 680 195 x 1,590 x 680

24 25 27 32 35

13 / 10 13 / 10 17 / 13 17 / 14 24 / 20 30 / 25

13 / 10 13 / 10 17 / 13 17 / 14 24 / 20 30 / 25

37 / 32 38 / 33 39 / 33 39 / 35 42 / 37 44 / 39

37 / 32 38 / 33 39 / 33 39 / 35 42 / 37 44 / 39

53 / 48 54 / 49 55 / 49 55 / 51 58 / 53 60 / 55

53 / 48 54 / 49 55 / 49 55 / 51 58 / 53 60 / 55

1~, 230V, 50Hz

BRC7E66

BRC7E63

BRC1D52

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions H x W x D mm

Weight kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level (H)cooling dB(A)

heating dB(A

Power supply V1

Infrared remote controlcooling only

heat pump

Wired remote control

whisper quietselfdiagnosis

dryprogramme

energyefficiency

timer twin/triple/double twinapplication

infraredremote control

(optional)

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

fan only fan speed2 steps

air filter

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).18

FHQ

EPC_08-114.indd 18 1/18/08 10:04:06 AM

FUQ

FUQ100,125B

FUQ-B

FUQ71B FUQ100B FUQ125B

7.1 10.0 12.5

8.0 11.2 14.0

2.21 3.12 4.15(V1) / 4.05(W1)

2.34 3.37(V1) / 3.28(W1) 4.33(V1) / 4.36(W1)

3.21 3.21 3.01(V1) / 3.09(W1)

3.42 3.32(V1) / 3.41(W1) 3.23(V1) / 3.21(W1)

A A B

B C(V1) / B(W1) C

1,105 1,560 2,075(V1) / 2,025(W1)

165 x 895 x 895 230 x 895 x 895

25 31

19 / 14 29 / 21 32 / 23

19 / 14 29 / 21 32 / 23

40 / 35 43 / 38 44 / 39

40 / 35 43 / 38 44 / 39

56 / 51 59 / 54 60 / 55

56 / 51 59 / 54 60 / 55

580

1~, 230V, 50Hz

BRC7C528

BRC7C529

BRC1D52

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions H x W x D mm

Weight kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level (H / L)cooling dB(A)

heating dB(A)

Drain-up height mm

Power supply V1

Infrared remote controlcooling only

heat pump

Wired remote control

selfdiagnosis

dryprogramme

air filter whisper quiet twin/triple/double twinapplication

standard drainpump kit

energyefficiency

timer

infrared remotecontrol (optional)

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

draughtprevention

fan only

fan speed2 steps

4 - W a y B l o w C e i l i n gS u s p e n d e d C a s s e t t e

Ideal for refurbishmentLeaves maximum floor and wall space for furniture, decorationFlexible installation: can be installed in the middle of a room or in a cornerAir can be discharged in any of four directionsAir flow distribution for ceiling heights up to 3.5mNo ceiling stainingPossibility to shut off one or two flaps for easy installation in cornersExtremely quiet in operationAir filter, drain pan and heat exchanger fin are mildew proofDrain-up pump with increased lift of 500mm

››››››››››

4 - W a y B l o w C e i l i n g S u s p e n d e d C a s s e t t e

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity). 19

EPC_08-114.indd 19 1/18/08 10:04:12 AM

FAQ71B

FAQ-B

FAQFAQ71B FAQ100B

7.1 10.0

8.0 11.2

2.36 3.45(V1) / 2.78(W1)

2.42 3.27(V1) / 3.39(W1)

3.01 2.90(V1) / 3.60(W1)

3.31 3.43(V1) / 3.30(W1)

B C(V1) / A(W1)

C B(V1) / C(W1)

1,180 1,725(V1) / 1,390(W1)

290 x 1,050 x 230 360 x 1,570 x 200

13 26

19 / 15 23 / 19

19 / 15 23 / 19

43 / 37 45 / 41

43 / 37 45 / 41

59 / 53 61 / 57

59 / 53 61 / 57

1~, 50Hz, 230V

BRC7E619 BRC7C511

BRC7E618 BRC7C510

BRC1D52

HEAT PUMP (air cooled)

Cooling capacity nominal kW

Heating capacity nominal kW

Nominal inputcooling nominal kW

heating nominal kW

EER

COP

Energy labelcooling

heating

Annual energy consumption cooling kWh

Dimensions H x W x D mm

Weight kg

Air flow rate (H / L)cooling m3 / min

heating m3 / min

Sound pressure level (H / L)cooling dB(A)

heating dB(A)

Sound power level (H / L)cooling dB(A)

heating dB(A)

Power supply V1

Infrared remote controlcooling only

heat pump

Wired remote control

Notes: 1) Energy label: scale from A (most efficiënt) to G (less efficiënt).2) Annual energy consumption: based on average use of 500 running hours per year full load (= nominal capacity).

Lightweight and compactDesigned to allow maximum use of floor spaceThe 71 class has a lightweight and compact casingEven air distribution via automatic movable louvre that can alsobe fixed at any desired angleThe flap of the unit is closed when not operatingThe front panel of the casing (71 class) is easy removable and washableExtremely quiet in operation

››››

›››

W a l l M o u n t e d U n i t

W a l l M o u n t e d U n i t

selfdiagnosis

dryprogramme

air filter whisper quiet twin/triple/double twinapplication

energyefficiency

timer

infrared remotecontrol (optional)

wired remotecontrol

(optional)

centralisedremote control

(optional)

vertical autoswing

auto restart auto cooling/heating

changeover

fan speed2 steps

fan only

20

EPC_08-114.indd 20 1/18/08 10:04:14 AM

RZQ-B/C

RZQ

S u p e r I n v e r t e r

S u p e r I n v e r t e r

Energy saving: increased EER up to 4.1 (energy label A)Extended range: 71 up to 250 classEnsures maximum comfortSound pressure performance down to 43 dB(A)Extended operating rangeSuits computer room applications (RZQ71-140)Re-use of existing R-22 or R-407C piping possibleWide range of indoor units: 8 different models in 35 different variants

››››››››

HEAT PUMP RZQ71CV1 RZQ100CV1 RZQ100BW1 RZQ125CV1 RZQ125BW1 RZQ140CV1 RZQ140BW1 RZQ200C RZQ250C

Power supply 1~, 50Hz, 230V 1~, 50Hz, 220-240V 3N~, 50Hz, 400V 1~, 50Hz, 220-240V 3N~, 50Hz, 400V 1~, 50Hz, 220-240V 3N~, 50Hz, 400V 3N~, 50Hz, 380-415V

Dimensions H xW x D mm 770 x 900 x 320 1,170 x 900 x 320 1,345 x 900 x 320 1,170 x 900 x 320 1,345 x 900 x 320 1,170 x 900 x 320 1,345 x 900 x 320 1,680 x 930 x 765

Weight kg 68 103 106 103 106 103 106 183 184

Colour Ivory White Daikin White

Sound pressure level(night quiet mode)

cooling dB(A) 47 (43) 49 (45) 49 (45) 50 (45) 50 (45) 50 (46) 50 (45) 57 57

heating dB(A) 49 51 (45) 51 (45) 52 (45) 52 (45) 52 (46) 52 (45) 57 57

Sound power level (nom) cooling dB(A) 63 65.0 65.0 66.0 66.0 67.0 66.0 78 78

Compressor type Hermetically sealed swing

Refrigerant type R-410A

Refrigerant charge kg 2.75 3.7 4.30 3.7 4.30 3.7 4.30 8.3 9.3

Refrigerant oil FVC50K Daphne FVC68D Daphne FVC68D Daphne FVC68D Synthetic (ether) oil

Refrigerant oil charge l 0.75 1.0 1.0 1.0 1.0 1.0 1.0 0.3 0.3

Minimum / ma x imum piping length m 5 / 50 (equivalent 70) 5 / 75 (equivalent 95) 5 / 75 (equivalent 95) 5 / 75 (equivalent 95) 5 / 100

Chargeless piping length m 30 30 30 30 30 30 30 30 30

Ma x imum installation height difference m 30 30.0 30.0 30.0 30.0 30.0 30.0 30 30

Ma x imum interunit level difference m 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

Piping connections

liquid mm 9.5 9.52 9.52 9.52 9.52 9.52 9.52 9.5 12.7

gas mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 22.2 22.2

drain mm 3 x 26 3 x 26 3 x 26 3 x 26 3 x 26 3 x 26 3 x 26 - -

Operationrange

cooling from ~ to °CDB -15.0 ~ 50.0 -5.0 ~ 46.0

heating from ~ to °CWB -20.0 ~ 15.5 -15.0 ~ 15.0

OPTIONAL ACCESSORIESNAME OF OPTION RZQ71C RZQ100C RZQ100BW1 RZQ125C RZQ125BW1 RZQ140C RZQ140BW1 RZQ200C RZQ250C

Central drain plug KKPJ5F180 KKPJ5F180 KKPJ5F180 KKPJ5F180 KWC26B280

Refrigerant branch piping

for twinKHR-

Q22M20TAKHR-

Q22M20TAKHRQ22M20TA

(KHRQ58T)*KHR-

Q22M20TAKHRQ22M20TA

(KHRQ58T)* KHRQ22M20TA KHRQ22M20TA(KHRQ58T)* KHRQ22M20TA

for triple - KHRQ127H KHRQ127H(KHRQ58T)* KHRQ127H KHRQ127H

(KHRQ58T)* KHRQ127H KHRQ127H(KHRQ58T)* KHRQ250H

for double twin - - - KHRQ22M20TA(3 x )

KHRQ22M20TA(KHRQ58T)* (3 x ) KHRQ22M20TA (3 x ) KHRQ22M20TA

(KHRQ58T)* (3 x ) KHRQ22M20TA (3 x )

Demand adapter kit KRP58M51 KRP58M51 KRP58M51 KRP58M51 KRP58M51

* For RZQ100-140B8W1B in combination with FCQ35-71C or FCQH71C, please use the refrigerant brach piping mentioned between brackets.

- Information was not available at time of publication.

21

EPC_08-114.indd 21 1/18/08 10:04:26 AM

V1 = 1~, 230V, 50HzV3 = 1~, 230V, 50HzVE = 1~, 220-240V, 50Hz/60HzW1 = 3N~, 400V, 50Hz

COOLING ONLY1) nominal cooling capacities are based on:

indoor temperature 27°CDB/19°CWB

outdoor temperature 35°CDB

refrigerant piping length 7.5m

level difference 0m

HEAT PUMP1) nominal cooling capacities are based on:

indoor temperature 27°CDB/19°CWB

outdoor temperature 35°CDB

refrigerant piping length 7.5m

level difference 0m

2) nominal heating capacities are based on:

indoor temperature 20°CDB

outdoor temperature 7°CDB/6°CWB

refrigerant piping length 7.5m

level difference 0m

POWER SUPPLY

MEASURING CONDITIONS

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acousticenvironment (for measuring conditions: please refer to the technical databooks).The sound power level is an absolute value indicating the “power” which a sound source generates.For more detailed information please consult our technical databooks.

22

EPC_08-114.indd 22 1/18/08 10:04:36 AM

‘We Care’ Icons

Whisper quietDaikin indoor units are whisper quiet. Also the outdoor units areguaranteed not to disturb the quiet of the neighbourhood.

Self-diagnosisSimplifies maintenance by indicating system faults or operatinganomalies.

Double thermostat functionControls the temperature via a sensor on the air conditioner or via asensor on the remote control.

Ceiling soiling preventionA special function prevents air blowing out too long in horizontalposition, to prevent ceiling stains.

TimerAllows to preset the air conditioner to start/stop at a specified time.

Air filterRemoves airborne dust particles to ensure a steady supply of clean air.

Drain pump kitFacilitates condensation draining from the indoor unit.

Vertical auto swingPossibility to select automatic vertical moving of the air discharge louvre,for uniform air flow and temperature distribution.

Infrared remote controlInfrared remote control with LCD to start, stop and regulate the airconditioner from a distance.

Wired remote controlWired remote control to start, stop and regulate the air conditionerfrom a distance.

Centralised controlCentralised control to start, stop and regulate several air conditionersfrom one central point.

Auto cooling-heating changeoverAutomatically selects cooling or heating mode to achieve the settemperature (heat pump types only).

Dry programmeAllows humidity levels to be reduced without variations in roomtemperature.

Energy efficiencyDaikin air conditioners are energy efficient and economical.

Fan onlyThe air conditioner can be used as fan, blowing air withoutcooling or heating.

Draught preventionWhen starting to warm up or when the thermostat is off, the air dischargedirection is set horizontally and the fan to low speed, to prevent draught.After warming up, air discharge and fan speed are set as desired.

Auto-restartThe unit restarts automatically at the original settings after powerfailure.

Twin/triple/double twin application2, 3 or 4 indoor units can be connected to only 1 outdoor unit evenif they have different capacities. All indoor units operate within thesame mode (cooling or heating) from one remote control.

Horizontal auto swingPossibility to select automatic horizontal moving of the air dischargelouvre, for uniform air flow and temperature distribution.

Fan speed stepsAllows to select up to the given number of fan speed.

Daikin air conditioners offer a comprehensive range of features to enhance your comfort. In this catalogue,main features are represented by following pictogrammes:

A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product featuresthat have an impact on reducing energy consumption:

23

EPC_08-114.indd 23 1/18/08 10:04:44 AM

EPC

EN08

-114

•80

0•

01/0

8•

Cop

yrig

ht©

Dai

kin

The

pres

ent

publ

icat

ion

supe

rsed

esEP

LEN

07-1

14.

Prin

ted

onno

n-ch

lorin

ated

pape

r.Pr

epar

edby

LaM

ovid

a,Be

lgiu

mR

esp

on

sib

leEd

ito

r:D

aiki

nEu

rop

eN

.V.,

Zan

dvo

ord

estr

aat

30

0,

B-8

40

0O

ost

end

e

The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet to thebest of its knowledge. No express or implied warranty is givenfor the completeness, accuracy, reliability or fitness for particularpurpose of its content and the products and services presentedtherein. Specifications are subject to change without prior notice.Daikin Europe N.V. explicitly rejects any liability for any direct orindirect damage, in the broadest sense, arising from or relatedto the use and/or interpretation of this leaflet. All content iscopyrighted by Daikin Europe N.V.

Daikin Europe N.V. is approved by LRQA forits Quality Management System in accordancewith the ISO9001 standard. ISO9001 pertains toquality assurance regarding design, development,manufacturing as well as to services related to theproduct.

ISO14001 assures an effective environmentalmanagement system in order to help protecthuman health and the environment from thepotential impact of our activities, products andservices and to assist in maintaining and improvingthe quality of the environment.

Daikin units comply with the European regulationsthat guarantee the safety of the product.

Daikin Europe N.V. participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory. Multi units are Euroventcertified for combinations up to 2 indoor units.

Daikin’s unique position as a manufacturer ofair conditioning equipment, compressors andrefrigerants has led to its close involvement inenvironmental issues.For several years Daikin has had the intentionto become a leader in the provision ofproducts that have limited impact on theenvironment.This challenge demands the eco design anddevelopment of a wide range of productsand an energy management system,resulting in energy conservation and areduction of waste.

Daikin products are distributed by:

Naamloze Vennootschap

Zandvoordestraat 300

B-8400 Oostende, Belgium

www.daikin.eu

BTW: BE 0412 120 336

RPR Oostende

EPC_08-114.indd 24 1/18/08 10:04:50 AM