5.2 detection & monitoring of pollution

12
第第第 第第第第第第第第第第第 第第第 第第第第第第第第第第第 第第 第第 pH pH 第第第第 第第第第

Upload: charissa-rivera

Post on 01-Jan-2016

168 views

Category:

Documents


2 download

DESCRIPTION

5.2 Detection & Monitoring of Pollution. Sub-subtopics. 5.2.1 Describe two direct methods of monitoring pollution. 5.2.2 Define the term biochemical oxygen demand (BOD) and explain how this indirect method is used to assess pollution levels in water. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: 5.2 Detection & Monitoring of Pollution

5.2 Detection & Monitoring of Pollution

Page 2: 5.2 Detection & Monitoring of Pollution

Sub-subtopics

5.2.1 Describe two direct methods of monitoring pollution.5.2.2 Define the term biochemical oxygen demand (BOD) and explain

how this indirect method is used to assess pollution levels in water.5.2.3 Describe and explain an indirect method of measuring pollution

levels using a biotic index.

Page 3: 5.2 Detection & Monitoring of Pollution

5.2.1 Methods of MonitoringWhere to start?

AIR

WATER

LAND

Retirieved on 01-11-2013 from: http://www.sciencekids.co.nz/images/pictures/health/pollutionhealtheffects.jpg

What to do?

DIRECT

INDIRECT

CHANGES

GradientsTime periods

Transects

Page 4: 5.2 Detection & Monitoring of Pollution

Particulate Matter (PM)● Removed by rain

Sheets of glue-coated or Vaseline coated paper with grids for standard amount of time.

● microscope/magnifying lens● % coverage● # of specimens

NumberSizeLocation

Sources of error?

5.2.1 Monitoring AIR Quality

https://www.youtube.com/watch?v=I9_EWYAl4NA

Page 5: 5.2 Detection & Monitoring of Pollution

Secondary Data Sources:● Czech Republic - ČHMI● EU - AirMonTech● U.S. - EPA● China - AQICN ● India - CPCB● Brazil - MMA● Australia - AGDE● South Africa - SAAQIS● Egypt - EEAA-EIMP● Bangladesh - CASE

What they measure:● sulfur dioxide● oxides of nitrogen● ozone● VOC’s● particulate matter (sizes)

5.2.1 Monitoring AIR Quality

Page 6: 5.2 Detection & Monitoring of Pollution

Soil (edaphic) factors● physical properties● chemical properties● biological properties● processes● characteristics

No one measure is an indicator:● texture● density● infiltration● water retention● organic matter● mineral content (N, P, K)● microbial biomass● soil respiration

5.2.1 Monitoring LAND QualityR

etrie

ved

on 0

4-11

-201

3 fr

om:

http

://so

ils.u

sda.

gov/

sqi/a

sses

smen

t/im

ages

/sq_

buck

et_c

onte

nts.

jpg

Page 8: 5.2 Detection & Monitoring of Pollution

Direct Sampling Methods(chemical indicators)● salinity (probe)● pH (probe; universal indicator paper)● temperature (probe)● Dissolved Oxygen (DO probe)● wave action● flow velocity (orange)● turbidity (secchi disk)

○ Total Suspended Solids (TSS)○ Total Dissolved Solids (TDS)

● Biochemical Oxygen Demand (BOD)● Chemical Oxygen Demand (COD)● nitrates (NO3

- probe; test kit)● ammonia (NH3 probe; test kit)● phosphate (probe; test kit)● conductivity (probe)

5.2.1 Monitoring WATER Quality

Ret

rieve

d on

01-

11-2

013

from

: http

s://e

ncry

pted

-tbn

2.gs

tatic

.com

/imag

es?

q=tb

n:A

Nd9

GcQ

X-

sbuP

EpO

8r1K

7BtW

Nb8

FQ

lMG

so6Z

OK

nlZ

Aga

IGg_

yfE

mR

Go4

Lw

Page 9: 5.2 Detection & Monitoring of Pollution

5.2.1 Monitoring WATER Quality

Secondary Data Sources:● Czech Republic - ČHMI● EU - WISE● U.S. - NWQMC● China - IPE ● India - CPCB’s NWMP● Russia - VINITI● Brazil - ANA● Australia - NWQMS● South Africa - WMS● Egypt - EMWIS-EG● Bangladesh- BWDB

What they measure:● same as last slide● hardness● potability

Retrieved on 01-11-2013 from: http://ks.water.usgs.gov/pubs/reports/wrir.00-4126.cov.ill.jpeg

Page 10: 5.2 Detection & Monitoring of Pollution

5.2.2 B.O.D.Biological Oxygen Demand (BOD5)● First done in England 1912● measures organic pollution in H2O (aerobic bacteria & fungus)● units: mg (O2 consumed)/L● usually 5 days incubation at 20 ºC

○ 68% of BOD exerted after this time● tests vary 10-20%● Indirect method

Chemical Oxygen Demand

Retrieed on 04-11-2013 from: http://www.bre.umd.edu/agtopics/pict/bodpict.gif

Page 11: 5.2 Detection & Monitoring of Pollution

5.2.2 B.O.D.

Steps for measuring Biological Oxygen Demand (BOD5)

1. Sample H2O of measured volume

2. Measure the O2 level (probe)3. Place sample in a dark, 20 ºC

place for 5 daysa. Why in the dark?

4. After 5 days, remeasure O2

5. BOD5 = (Step 2 - Step 4) / L

Retrieved on 04-11-2013 from: http://www.globalw.com/images/products/OxiTop.jpg

Page 12: 5.2 Detection & Monitoring of Pollution

The greater the organic matter (nutrient load), the greater the BOD5 number

● sewage● fertilizer● runoff● detergents● others?

Municipal sewage (3-stage process): BOD ~20 mg/L

Untreated sewage● Europe: BOD ~600 mg/L● U.S.: BOD ~200 mg/L

(greater per capita water use)

What is ppm?

5.2.2 B.O.D.

Retrieved on 04-11-2013 from: http://www.enright.ie/wp-content/uploads/2008/10/bod-levels.jpg

Page 13: 5.2 Detection & Monitoring of Pollution

Eastern European Sewers

Retrieved on 04-11-2013 from: http://wwws4.eea.europa.eu/data-and-maps/figures/changes-in-wastewater-treatment-in-countries-of-europe-between-1980s-and-2005-east-3/csi24_fig5_291008.xls/image_large

Page 14: 5.2 Detection & Monitoring of Pollution

5.2.2 Nutrients in European Freshwater

The greater the organic matter (nutrient load), the greater the BOD5 number

● sewage● fertilizer● runoff● detergents● others?

Retrieved on 04-11-2013 from

: http://ww

w.eea.europa.eu/data-and-m

aps/indicators/freshwater-

quality/freshwater-quality-assessm

ent-published-may-2010

Page 15: 5.2 Detection & Monitoring of Pollution

5.2.3 Biotic IndicatorsAnother indirect method: Indicator Species● tolerant of organic pollution and/or low O2 levels● intolerant of organic pollution and/or low O2 levels

● More dangerous in summer○ solubility of O2 as temperature○ warm organic pollutants do the same

● Tubifex vs. mayfly nymph?● Others: fish, underwater plant life, algae (diatoms), bacteria (fecal

coli)

Retrieved on 04-11-2013 from: http://www.ib.bioninja.com.au/_Media/indicator_species.jpeg

Page 16: 5.2 Detection & Monitoring of Pollution

5.2.3 Trent Biotic Index

Based on disappearances

Measures diversity● Generally, pollution , diversity

○ abundance may be high, but low richness

● Maximum value = 10

Retrieved on 04-11-2013 from: http://nationalinsectweek.co.uk/sites/default/files/images/pollutdetect.gif

Page 17: 5.2 Detection & Monitoring of Pollution

5.2.3 Trent Biotic Index

Retrieved on 04-11-2013 from: http://click4biology.info/c4b/D/G4.htm