5001a retaining wall section - county waterford · relevant specifications, bills of quantities,...

1

Click here to load reader

Upload: doanmien

Post on 16-Apr-2018

217 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: 5001A RETAINING WALL SECTION - County Waterford · relevant Specifications, Bills of Quantities, Architectural, Services and Engineering drawings. 2. ... RC RETAINING WALL. RC RETAINING

LOOKING SOUTH

PART ELEVATION

LOOKING NORTH

PART ELEVATION

VIEWS OF EXISTING TIMBER RETAINING WALL

CARAVAN PARK FRONTAGE

MSL - Mean Sea Level - -0.07m

MLWS - Mean Low Water Spring - -1.92m

45

0

VA

RIE

S

400 450 2000

+ 0.50m ODM

+ 1.50m ODM

(Beach Level Varies)

+ 3.0m ODM

Abbreviations and Levels:

MHWS - Mean High Water Spring - +1.68m

MHWN - Mean High Water Neap - +0.88m

MLWN - Mean Low Water Neap - -1.02m

50mm Ø Weep Hole

Reckli Mould

Textured Finish

RETAINING WALL SECTION

20

Top of Wall

10

00

50-100kg ROCK ARMOUR on

GEOTEXTILE

3000

1

2

ROCK ARMOUR TO MERGE

INTO EXISTING SLOPE

+ 3.15m ODM

(Proposed Toe Level)

25

00

EXISTING SLOPE

5000

Note: Top level of proposed Retaining Wall

will be the same level as the wall fronting

the car park to the south

Scale 1:50

18156

ARDMORE COASTAL PROTECTIONCo. WATERFORD

5001 A

SITE LOCATION MAP, EXISTING LAYOUT MAPPROPOSED LAYOUT PLAN AND SECTIONCONCRETE RETAINING WALL

1: 1000, 75

Client

WATERFORD CITY & COUNTY COUNCIL

FT JUNE 2017PB JUNE 2017PP JUNE 2017POD JUNE 2017

REPRODUCED FROM THE ORDNANCE SURVEY

BY PERMISSION OF THE GOVERNMENT.

LICENCE No. EN 0015717.

OS MAP No. 1018_D.

Drg. No.

Approved

Scales (A1)

Ch'd(D.O.)Ch'd(Eng.)

Drawn

Project

Title

DescriptionDateRev.

Rev.

appby ch'd

Park HouseMahon Technology ParkBessboro RoadBlackrockCork.

Malachy Walsh and Partners

Engineering and Environmental Consultants

Cork Tralee London

Tel : +353 (0)21 4536400fax. : +353 (0)21 4536450E-mail : [email protected]

Limerick

A 08.06.17 ISSUED FOR COMMENT FT PEB PP

Notes

Legend

Reference Drawings

1. All drawings are to be read in conjunction with all

relevant Specifications, Bills of Quantities, Architectural,

Services and Engineering drawings.

2. Any discrepancies between these documents shall be

brought to the attention of the Engineer.

3. All dimensions are in millimetres unless noted otherwise.

4. Drawings are not to be scaled.

SITE LOCATION

EXISTING LAYOUT PLAN

SCALE 1:1000

PROPOSED LAYOUT PLAN

SCALE 1:1000

SITE LOCATION MAP

NTS

ELEVATION - REKLI MOULD FOR

TEXTURED CONCRETE SURFACE

AutoCAD SHX Text
T
AutoCAD SHX Text
HWM
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
WATER
AutoCAD SHX Text
HWM
AutoCAD SHX Text
HWM
AutoCAD SHX Text
WATER
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
T
AutoCAD SHX Text
HWM
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
WATER
AutoCAD SHX Text
HWM
AutoCAD SHX Text
HWM
AutoCAD SHX Text
WATER
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
CARAVAN PARK
AutoCAD SHX Text
RC RETAINING WALL
AutoCAD SHX Text
RC RETAINING WALL
AutoCAD SHX Text
AREA OF ROCK ARMOUR
AutoCAD SHX Text
AREA OF ROCK ARMOUR
AutoCAD SHX Text
AREA OF ROCK ARMOUR
AutoCAD SHX Text
EXISTING RETAINING WALL FRONTING CAR PARK
AutoCAD SHX Text
BEACH ACCESS TO BE MAINTAINED
AutoCAD SHX Text
BEACH ACCESS TO BE MAINTAINED
AutoCAD SHX Text
BEACH ACCESS TO BE MAINTAINED
AutoCAD SHX Text
I.S. EN ISO 9001