444316023432 - ntmi rc132v g4 lsc el versions
TRANSCRIPT
![Page 1: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/1.jpg)
1500mm x 1
x 2
80
RC132V G4 LED36S/840 PSU W60L60 OC ELB3
RC132V G4 LED36/840 PSU W60L60 OC TP(a)ELB3
RC132V G4 LED34S/830 PSD W60L60 OC ELB3
RC132V G4 LED36S/840 PSD W60L60 OC ELB3W4W2
RC132V G4 LED43S/840 PSD W60L60 OCELB3W4/W2
RC132V G4 LED36S/840 W60L60 OC IA1 ELB3 W4
RC132V G4 LED43S/840 W60L60 OC IA1 ELB3
RC132V G4 LED36/840 W60L60 OC TP(a)IA1 ELB3
RC133V G4 LED36S/840 PSD W62L62 OC ELB3
RC133V G4 LED34S/830 PSD W62L62 OC ELB3
RC132V G4 LED36S/840 PSU W30L120 OC ELB3
RC132V G4 LED36S/840 PSD W30L120 OC ELB3
RC132V G4 LED36S/840 W30L120 OC IA1 ELB3
RC132V G4 LED36S/840 PSU W60L60 NOC ELB3
RC132V G4 LED43S/840 PSD W60L60 NOC ELB3
RC132V G4 LED36S/840 W60L60 NOC IA1 ELB3
RC132V G4 LED43S/840 W60L60 NOC IA1 ELB3
RC132V G4 LED36S/840 PSU W30L120 NOC ELB3
RC132V G4 LED36S/840 W30L120 NOC IA1 ELB3
3600
3600
3400
3600
4300
3600
4300
3600
3600
3400
3600
3600
3600
3600
4300
3600
4300
4300
3600
4000
4000
3000
4000
4000
4000
4000
4000
4000
3000
4000
4000
4000
4000
4000
4000
4000
4000
4000
29
29
29
29
34
29
34
29
29
29
29
29
29
29
34
29
34
34
29
595×595×11
595×595×11
595×595×11
595×595×11
595×595×11
595×595×11
595×595×11
595×595×11
622×622×11
622×622×11
1195×295×11
1195×295×11
1195×295×11
595×595×11
595×595×11
595×595×11
595×595×11
595×595×11
1195×295×11
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
4.10
4.10
4.00
4.00
4.00
3.90
3.90
3.90
3.90
3.90
4.00
PSU/IA1 PSD
1/9
Printed in HungaryData subject to change without noticeKeep for future reference: www.philips.com/lighting
4443 160 23432© 2021, Signify Holding All rights reserved
318850
35
Emergency version - LPF/NiMH
![Page 2: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/2.jpg)
PSU PSD
①
①
②
②
③
③
④ +-
2/9
PSDPSU/IA1
A
B
A
BH H
![Page 3: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/3.jpg)
Versions with Wieland connector (W4, W4/W2) ELB3 versions Wieland (W4, W4/W2) ELB3 versions
GST18i4,4 pole, male
swL swN L N
DALI (BST14)
DADA
ELB3 versions
swN swL
Battery replacement
1 2 3
12
2
CLICK
The indicator LED must be mounted into the ceiling,
close to the luminaire
!
Ø 8,5 - 9 mm
Indicator LED
All ELB3 versions Only PSD
3/9
If the external �exible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exlusively available from the manufacturer or his service agent!
Emergency Luminaires
In case a self-contained emergency driver has been added, this is how to set the timers (IEC62034 (§6.3.2)):
DALI version: Check IEC 62386 part 202.
PRO version: The �rst test is randomized. Then a �xed schedule is maintained, there is no need to set the timers or take special precautions when powering
BASIC version: No timers available, only manual testing through the test button.
![Page 4: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/4.jpg)
Rated light output in emergency operation mode: 250lm
W60L60 NOCRated light output in emergency operation mode: 250lm
W30L120 NOCRated light output in emergency operation mode: 250lm
W60L60 OCRated light output in emergency operation mode: 250lm
W30L120 OC
4/9
Automatic emergency time selection After installation and power up the driver will detect the battery and start the automatic detection process.
- During automatic detection, the indicator LED will light up with short green flashes.
- Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of ce
lls)
and will set the emergency output power accordingly.
After that, the system is defined and fully operational. The battery type definition has influence on the performance
during the self-test and on the battery charge method. When the automatic battery detection process is disrupted,
e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver
will go into emergency mode with the lowest output power. At a next power up, the automatic detection process
will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7.2.3 and 7.2.4.
Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for
a period sufficient to ensure that each lamp is illuminated. Twice per year, each luminaire shall be tested for its
full rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.
Lifetime
The batteries have a life time expectancy of 4 years when maintained properly. Replace after that time!
Charge time
24.00
![Page 5: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/5.jpg)
4025
15
© 2019 Signify Holding.All rights reserved. This document contains information relating to the product portfolio of Signify which information maybe subject to change. No representation or warranty as to the accuracy or completeness of the information included hereinis given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is notintended as any commercial ofer and does not form part of any quotation or contract. Philips and the Philips ShieldEmblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or theirrespective owners.
Signify Holding.The Netherlands
5/9
Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur,Chlorine, Phthalates, etc, are present.
Luminaires not suitable for covering with thermally insulating material.
PSU29W 34.5W 29W
24
300
11181631
5.251
25404268
6.254
25404268
14.1212
19303151
14.3214
19303151
34.5WPSD
35WMultiColour/Lumen IA1 WIA
12
15
2504.950
15242440
![Page 6: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/6.jpg)
Scan me!
+
To get an overview of all spare parts for a luminaire,please refer to detailed instruc�ons in the service manualavailable via the Signify Service tag apps (Android and iOS).
Register me!2
6/9
![Page 7: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/7.jpg)
7/9 7/9
![Page 8: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/8.jpg)
8/98/9
![Page 9: 444316023432 - NTMI RC132V G4 LSC EL versions](https://reader034.vdocuments.mx/reader034/viewer/2022051600/627fad88948afb2f6b124186/html5/thumbnails/9.jpg)
9/9