9
1500mm x 1 x 2 80 RC132V G4 LED36S/840 PSU W60L60 OC ELB3 RC132V G4 LED36/840 PSU W60L60 OC TP(a)ELB3 RC132V G4 LED34S/830 PSD W60L60 OC ELB3 RC132V G4 LED36S/840 PSD W60L60 OC ELB3W4W2 RC132V G4 LED43S/840 PSD W60L60 OCELB3W4/W2 RC132V G4 LED36S/840 W60L60 OC IA1 ELB3 W4 RC132V G4 LED43S/840 W60L60 OC IA1 ELB3 RC132V G4 LED36/840 W60L60 OC TP(a)IA1 ELB3 RC133V G4 LED36S/840 PSD W62L62 OC ELB3 RC133V G4 LED34S/830 PSD W62L62 OC ELB3 RC132V G4 LED36S/840 PSU W30L120 OC ELB3 RC132V G4 LED36S/840 PSD W30L120 OC ELB3 RC132V G4 LED36S/840 W30L120 OC IA1 ELB3 RC132V G4 LED36S/840 PSU W60L60 NOC ELB3 RC132V G4 LED43S/840 PSD W60L60 NOC ELB3 RC132V G4 LED36S/840 W60L60 NOC IA1 ELB3 RC132V G4 LED43S/840 W60L60 NOC IA1 ELB3 RC132V G4 LED36S/840 PSU W30L120 NOC ELB3 RC132V G4 LED36S/840 W30L120 NOC IA1 ELB3 3600 3600 3400 3600 4300 3600 4300 3600 3600 3400 3600 3600 3600 3600 4300 3600 4300 4300 3600 4000 4000 3000 4000 4000 4000 4000 4000 4000 3000 4000 4000 4000 4000 4000 4000 4000 4000 4000 29 29 29 29 34 29 34 29 29 29 29 29 29 29 34 29 34 34 29 595×595×11 595×595×11 595×595×11 595×595×11 595×595×11 595×595×11 595×595×11 595×595×11 622×622×11 622×622×11 1195×295×11 1195×295×11 1195×295×11 595×595×11 595×595×11 595×595×11 595×595×11 595×595×11 1195×295×11 3.90 3.90 3.90 3.90 3.90 3.90 3.90 3.90 4.10 4.10 4.00 4.00 4.00 3.90 3.90 3.90 3.90 3.90 4.00 PSU/IA1 PSD 1/9 Printed in Hungary Data subject to change without notice Keep for future reference: www.philips.com/lighting 4443 160 23432 © 2021, Signify Holding All rights reserved 3 18 850 35 Emergency version - LPF/NiMH

Upload: others

Post on 14-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 444316023432 - NTMI RC132V G4 LSC EL versions

1500mm x 1

x 2

80

RC132V G4 LED36S/840 PSU W60L60 OC ELB3

RC132V G4 LED36/840 PSU W60L60 OC TP(a)ELB3

RC132V G4 LED34S/830 PSD W60L60 OC ELB3

RC132V G4 LED36S/840 PSD W60L60 OC ELB3W4W2

RC132V G4 LED43S/840 PSD W60L60 OCELB3W4/W2

RC132V G4 LED36S/840 W60L60 OC IA1 ELB3 W4

RC132V G4 LED43S/840 W60L60 OC IA1 ELB3

RC132V G4 LED36/840 W60L60 OC TP(a)IA1 ELB3

RC133V G4 LED36S/840 PSD W62L62 OC ELB3

RC133V G4 LED34S/830 PSD W62L62 OC ELB3

RC132V G4 LED36S/840 PSU W30L120 OC ELB3

RC132V G4 LED36S/840 PSD W30L120 OC ELB3

RC132V G4 LED36S/840 W30L120 OC IA1 ELB3

RC132V G4 LED36S/840 PSU W60L60 NOC ELB3

RC132V G4 LED43S/840 PSD W60L60 NOC ELB3

RC132V G4 LED36S/840 W60L60 NOC IA1 ELB3

RC132V G4 LED43S/840 W60L60 NOC IA1 ELB3

RC132V G4 LED36S/840 PSU W30L120 NOC ELB3

RC132V G4 LED36S/840 W30L120 NOC IA1 ELB3

3600

3600

3400

3600

4300

3600

4300

3600

3600

3400

3600

3600

3600

3600

4300

3600

4300

4300

3600

4000

4000

3000

4000

4000

4000

4000

4000

4000

3000

4000

4000

4000

4000

4000

4000

4000

4000

4000

29

29

29

29

34

29

34

29

29

29

29

29

29

29

34

29

34

34

29

595×595×11

595×595×11

595×595×11

595×595×11

595×595×11

595×595×11

595×595×11

595×595×11

622×622×11

622×622×11

1195×295×11

1195×295×11

1195×295×11

595×595×11

595×595×11

595×595×11

595×595×11

595×595×11

1195×295×11

3.90

3.90

3.90

3.90

3.90

3.90

3.90

3.90

4.10

4.10

4.00

4.00

4.00

3.90

3.90

3.90

3.90

3.90

4.00

PSU/IA1 PSD

1/9

Printed in HungaryData subject to change without noticeKeep for future reference: www.philips.com/lighting

4443 160 23432© 2021, Signify Holding All rights reserved

318850

35

Emergency version - LPF/NiMH

Page 2: 444316023432 - NTMI RC132V G4 LSC EL versions

PSU PSD

④ +-

2/9

PSDPSU/IA1

A

B

A

BH H

Page 3: 444316023432 - NTMI RC132V G4 LSC EL versions

Versions with Wieland connector (W4, W4/W2) ELB3 versions Wieland (W4, W4/W2) ELB3 versions

GST18i4,4 pole, male

swL swN L N

DALI (BST14)

DADA

ELB3 versions

swN swL

Battery replacement

1 2 3

12

2

CLICK

The indicator LED must be mounted into the ceiling,

close to the luminaire

!

Ø 8,5 - 9 mm

Indicator LED

All ELB3 versions Only PSD

3/9

If the external �exible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exlusively available from the manufacturer or his service agent!

Emergency Luminaires

In case a self-contained emergency driver has been added, this is how to set the timers (IEC62034 (§6.3.2)):

DALI version: Check IEC 62386 part 202.

PRO version: The �rst test is randomized. Then a �xed schedule is maintained, there is no need to set the timers or take special precautions when powering

BASIC version: No timers available, only manual testing through the test button.

Page 4: 444316023432 - NTMI RC132V G4 LSC EL versions

Rated light output in emergency operation mode: 250lm

W60L60 NOCRated light output in emergency operation mode: 250lm

W30L120 NOCRated light output in emergency operation mode: 250lm

W60L60 OCRated light output in emergency operation mode: 250lm

W30L120 OC

4/9

Automatic emergency time selection After installation and power up the driver will detect the battery and start the automatic detection process.

- During automatic detection, the indicator LED will light up with short green flashes.

- Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of ce

lls)

and will set the emergency output power accordingly.

After that, the system is defined and fully operational. The battery type definition has influence on the performance

during the self-test and on the battery charge method. When the automatic battery detection process is disrupted,

e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver

will go into emergency mode with the lowest output power. At a next power up, the automatic detection process

will start again.

Periodic testing

Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7.2.3 and 7.2.4.

Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for

a period sufficient to ensure that each lamp is illuminated. Twice per year, each luminaire shall be tested for its

full rated duration (at least 3hrs).

For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.

Lifetime

The batteries have a life time expectancy of 4 years when maintained properly. Replace after that time!

Charge time

24.00

Page 5: 444316023432 - NTMI RC132V G4 LSC EL versions

4025

15

© 2019 Signify Holding.All rights reserved. This document contains information relating to the product portfolio of Signify which information maybe subject to change. No representation or warranty as to the accuracy or completeness of the information included hereinis given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is notintended as any commercial ofer and does not form part of any quotation or contract. Philips and the Philips ShieldEmblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or theirrespective owners.

Signify Holding.The Netherlands

5/9

Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur,Chlorine, Phthalates, etc, are present.

Luminaires not suitable for covering with thermally insulating material.

PSU29W 34.5W 29W

24

300

11181631

5.251

25404268

6.254

25404268

14.1212

19303151

14.3214

19303151

34.5WPSD

35WMultiColour/Lumen IA1 WIA

12

15

2504.950

15242440

Page 6: 444316023432 - NTMI RC132V G4 LSC EL versions

Scan me!

+

To get an overview of all spare parts for a luminaire,please refer to detailed instruc�ons in the service manualavailable via the Signify Service tag apps (Android and iOS).

Register me!2

6/9

Page 7: 444316023432 - NTMI RC132V G4 LSC EL versions

7/9 7/9

Page 8: 444316023432 - NTMI RC132V G4 LSC EL versions

8/98/9

Page 9: 444316023432 - NTMI RC132V G4 LSC EL versions

9/9