400w uv cannon - prolight · 400w uv cannon user anual 3 product overview & technical...

4
Order code: UV02 400W UV Cannon User Manual

Upload: vanxuyen

Post on 03-May-2018

276 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: 400W UV Cannon - Prolight ·  400W UV Cannon User anual 3 Product overview & technical specifications This powerful 400W UV cannon will fill …

Order code: UV02

400W UV Cannon User Manual

Page 2: 400W UV Cannon - Prolight ·  400W UV Cannon User anual 3 Product overview & technical specifications This powerful 400W UV cannon will fill …

www.prolight.co.uk 400W UV Cannon User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

Whenconnectedtothemainspowersupplytheunitshouldilluminate.TheUVcannonutilisesamercuryvapourlampwhichwilltake5-10minutestoreachitsfullintensity.Theintensityofthelampwillincreasewithuse.Thelightemittedfromthisunitisinvisibleanddoesnothavetheglowofafluorescentfixture.

• ThisdevicefallsunderprotectionclassI.Itisthereforeessentialtobeearthed.Haveaqualifiedpersontocarryoutthisconnection.

• Useanappropriatesafetycabletofixthedevice(e.g.CLAM03).

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Onlyusetheequipmentindoors.

• Donotexposetoflammablesources,liquidsorgases,andinstallaminimumof0.5mfromthesesourcesandanyilluminatedsurface.

• Nevercovertheunitsvents

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablevoltageisbetween240V,50Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Duetothenatureofthemercuryvapourlamp,thelampmustbeallowedtocooldownfor5-10minutesbeforere-igniting.Failuretowaitforthelamptocooldownmaycausethelamptofailprematurely.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• WARRANTY:Oneyearfromdateofpurchase.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION!THIS DEVICE RADIATES ULTRAVIOLET (UV) LIGHT WHEN OPERATIONAL. MOST OF THE UV LIGHT IS NOT VISIBLE. EXPOSURE TO UV RADIATION CAN BE HARMFUL TO YOUR HEALTH AND CAN DAMAGE YOUR EYES. PROTECT YOUR EYES AND SKIN, AND DO NOT LOOK DIRECTLY AT THE UNIT DURING OPERATION. DO NOT OPERATE THIS UNIT WITHOUT CORRECT SAFETY TRANING PRIOR TO OPERATION, AND TAKE THE APPROPRIATE PRECAUTIONS. DO NOT ALLOW CHILDREN OR UNTRAINED PERSONNEL TO OPERATE THE UNIT.

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

Page 3: 400W UV Cannon - Prolight ·  400W UV Cannon User anual 3 Product overview & technical specifications This powerful 400W UV cannon will fill …

www.prolight.co.uk 400W UV Cannon User Manual 3

Product overview & technical specifications

Thispowerful400WUVcannonwillfillavarietyofvenueswithanoutstandingUVglow.Theunithasbeenspeciallydesignedtohousea400Wblacklightlamp(notincluded)andalsofeaturesaprotectivefrontgrillandhangingbracket.Thishighoutputfixturewilltransformanyevent,club,bowlingalleyorstagebycreatingawidespreadofatmosphericUVlight.

•400Wsuperhighoutputblacklight

•UVlamprequired(Notincluded–Ordercode:LAMP64)

•Hangingbracketallowsformultipleriggingapplications

400W UV Cannon

Specifications UV Cannon

Powerconsumption 400W

Powersupply 240V,50Hz

Dimensions 307x355x455mm

Weight 8.05kg

Ordercode UV02

455mm

307

mm

355mm

380mm

01-Captivepowerconnection

02-Fuse250V,4A

03-Earthpoint

04-Safetyeye

05-Vents

Inthebox:1 x fixture, 1 x power cable, hanging bracket & 1 x user manual

POWER SUPPLY: 240V~50Hz

FUSE:250V, 4A

UV CANNONwww.prolight.co.uk

01

02

03

04

05

Page 4: 400W UV Cannon - Prolight ·  400W UV Cannon User anual 3 Product overview & technical specifications This powerful 400W UV cannon will fill …

www.prolight.co.uk 400W UV Cannon User Manual 4

WEEE notice

LAMP INFORMATION:• Onlyfitorreplacethelampwhenthedeviceisunpluggedfromthemains.

• Letthelampcooldownfor5-10minutesbeforereplacingitasthetemperatureofthelampcanreach700°Cduringoperation.

• Whenhandlingthelamp,donottouchitwithyourbarehands,useaclothtoinsertorremoveit.

• Donotinstalllampswithahigherwattagethanwhatthisunitisdesignedfor.

• Replaceadeformedordamagedlampwithalampofthesametype.

• Toreplacethelamp:1.Unscrewandremovetheprotectivegrille.2.Carefullyremovetheoldlampandinsertthenewlampintothesocket.3.Replacetheprotectivegrilleandtightenthescrews.

• CareshouldbetakenwhenhandlingUVcannonsandlampsduetothelampsbeingveryfragile.UVcannonscontaininglampsshouldalwaysbetransportedinafoamlined,paddedflightcasewiththelampfacingdownwardsinaverticaldirection.Shocks,dropsorsuddenmovementscanleadtodamageofthelamporlampbase.

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.