4000.biotools flyer 2013.ppt - fisher...

8
Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership Heidolph BioTools Guide Premium Laboratory Equipment

Upload: lenhan

Post on 11-Feb-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership

HeidolphBioTools Guide

Premium Laboratory Equipment

Page 2: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Heidolph In field Sales Contacts

Regional Sales Manager - Eastern Zone Jason Paloskey [email protected]

New Jersey, Pennsylvania, West Virginia, Virginia, Maryland, Delaware, District of Columbia, Metro New York, Long IslandAndrew Ungerleider [email protected]

Connecticut, Rhode Island, Massachusetts, Maine, Vermont, New Hampshire, Eastern Upstate New YorkDavid Bauer [email protected]

North Carolina, South Carolina, Georgia, Florida, AlabamaCharles Bohnenblusch [email protected]

East Canada, Quebec, Atlantic / Maritime ProvincesPostal Codes: A through K7Carole Denis [email protected]

Regional Sales Manager - Western Zone Michael Bishop [email protected]

Southern California, Utah, Southern Nevada, Arizona, New Mexico, ColoradoSteven Kang [email protected]

Northern California, Oregon, Washington, Alaska, Hawaii, Montana, Northern Nevada, Wyoming, IdahoFrancis Allard [email protected]

Texas, Louisiana, Oklahoma, Mississippi, ArkansasAyse Cooper [email protected]

Illinois, Northern Indiana, Wisconsin, Minnesota, Kansas, Iowa, North Dakota, South Dakota, Missouri, Nebraska, Puerto Rico, US Virgin IslandsFranklin Limpin [email protected]

Michigan, Ohio, Central/Southern Indiana, Tennessee, Kentucky, Western New York Steve Drayer [email protected]

Central Canada: Manitoba - Saskatchewan and K8 Westward in Ontario; Western Canada: Alberta, British Columbia, Yukon, Northwest Territories, Nunavut

Denis Gosselin [email protected]

Page 3: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Unit

Power

Supply Current

Heating

time to

273F

(134C)

Chamber

Volume

Chamber

Dimensions

(Dia. x D)

Tray Dimensions

(W x D x H)

Overall Dimensions

(W x D x H) Weight

2 gal 7 x 12 in 4.7 x 11.6 x 0.8 in 17 x 16 x12.5 in 55 lb

7.5 L 17.8 x 30.5 cm 12 x 29.5 x 2cm 43.2 x 40.6 x 31.8 cm 25 kg

5 gal 9 x 18 in 6.7 x 16.3 x 0.8 in 20 x 20 x 15 in 79 lb

19 L 22.9 x 45.7 cm 17 x 41.5 x 2 cm 50.8 x 50.8 x 38.1 cm 36 kg

6 gal 10 x 18 in 6.7 x 16.3 x 0.8 in 20 x 20 x 15 in 106 lb

23 L 25.4 x 45.7 cm 17 x 41.5 x 2 cm 50.8 x 50.8 x 38.1 cm 48 kg

6 gal 10 x 18 in 6.7 x 16.3 x 0.8 in 20 x 20 x 15 in 106 lb

23 L 25.4 x 45.7 cm 17 x 41.5 x 2 cm 50.8 x 50.8 x 38.1 cm 48 kg

7.8 gal 12.2 x 18.5 in 7.8 x 16.1 x 1 in 23.5 x 21.5 x 18 in 132 lb

34.4 L 31.0 x 46.9 cm 19.8 x 40.8 x 2.5 cm 59.7 x 54.6 x 45.7 cm 60 kg

17 gal 15 x 20 in 14 x 20 x 1 in 26 x 27 x 21 in 196 lb

65 L 38.1 x 50.8 cm 35 x 50 x 2.5 cm 66 x 68.6 x 53.3 cm 89 kg

22 gal 15 x 27 in 14 x 26 x 1 in 26 x 34 x 21 in 225 lb

84 L 38.1 x 68.6 cm 35 x 67 x 2.5 cm 66 x 86.4 x 53.3 cm 102 kg

Technical Specifications for Heidolph Tuttnauer Benchtop Sterilizers

Valueklave 1730 1,050 W 11A 3 min

Models 2340 1,400 W 12A 20 min

Models 2540M, E,

EP, EA, EAP1,400 W 12A 20 min

Kwiklave Model

2540EAKP2,200 W 12A 6 min

Models 3545 2,200 W 13.6A 25min

Models 3850 2,400 W 13.6 A 30min

Models 3870 2,700 W 13.6A 30 min

Areas these units are used: All research laboratories,

Pharmaceutical, Food & Beverage, Cosmetic, Breweries, High School

Labs, Community College Labs, WWTP, Universities

Applications: Sterilizing of glassware, biohazard waste, instruments,

flasks, food sterilization

Autoclaves for laboratory sterilization applications of

instrumentation, liquid, glass, and biohazard. Autoclave features are

specifically designed for lab applications used in laboratory,

microbiology, pharmaceutical, food and chemical industries.

Designed to provide high quality repeatable performance and

documentation for laboratory applications and quality assurance

processes.

Product Features:

� 60 minute cycle timer

� ASME stamped, 316Ti stainless steel chamber

ensures long lasting reliability, durability and high

corrosion resistance

� Temperature selection from 100C (212F to 273F)

� Combination pressure and temperature gauge

with peak indicator

� Low water alarm sounds when reservoir needs

to be refilled

� Standby heating – keeps chamber warm for

quicker cycles

� UL and CSA approved

� 1 Year Warranty

Electronic Units:

� Automates each cycle, including water fill,

heating, sterilization, exhaust and drying are

microprocessor controlled. Optional printer

available

Mechanical Units:

� Manual operated models feature analog

control and gauges for simple operation

� Operator must manually switch to each

process

Units are 115v and 220v depending on size

Heidolph Tuttnauer Benchtop Electronic & Mechanical Autoclaves

Page 4: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Model ELV/ELVC 2840 ELV/ELVC 3850 ELV/ELVC 3870 ELV/ELVC 5075

Chamber Volume 31 L 62 L 85 L 160 L

Chamber Dimensions (Diam x Depth) 28 cm x 46 cm 38 cm x 48 cm 38 cm x 68 cm 50 cm x 75 cm

44 x 54 x 98 cm 50 x 65 x 76 cm 50 x 65 x 96 cm 110 x 86.6 x 71.5 cm

17.3 x 21.3 x 38.58 in 19.69 x 25.59 x 29.92 in 19.69 x 25.59 x 37.80 in 43 x 34 x 28 in

Voltage requirements 220V/ 50-60 Hz 220V/ 50-60 Hz, 3-phase 220V/ 50-60 Hz, 3-phase 230V/ 50-60 Hz, 3-phase

Power requirements 2.2 KW 6.0 KW 6.0 KW 9.0 KW

Max Temperature 135C 135C 135C 135C

Chamber Material stainless steel 316 Ti (1.4571) stainless steel 316 Ti(1.4571) stainless steel 316 Ti(1.4571) stainless steel 316 Ti(1.4571)

Housing/Door Material stainless steel 304 L stainless steel 304 L stainless steel 304 L stainless steel 304 L

Air Supply Pressure to be Regulted

Bar (psi)3-8 (43-116) 3-8 (43-116) 3-8 (43-116) 2.8 bar (40 psi)

Feed water pressure to be regulted

Bar (psi)2-3 (29-43) 2-3 (29-43) 2-3 (29-43) 2.8 bar (40 psi)

Internal Thermometer included included included included

Sample Temperature Proves set of 2, included set of 2, included set of 2, included set of 2, included

Water-sensing Electrode included included included included

External Pressure Gauge included included included included

Printer included included included included

RS-232 connection included included included included

Wire baskets set of 2, included included included included

Shipping volume (m3) 0.21 0.56 0.56 1.35

Shipping Weight 57kg/125 lb 101 kg/222lb 116 kg/225 lb 223 kg/ 492 lb

Net Weight 48kg/105lb 85 kg/187lb 100 kg/220 lb 190 kg/ 418 lb

Compressed Air* 1/2" 3-4 Bar

Tap Water* 1/2" 3-4 Bar

Mineral free water*

Drain* 2" Min Withstanding temp of 80C (176F)

* For system requirements for ELV/ELVC models contact sales representatives for more information

1/2" 2-3 Bar

Technical Specifications for Heidolph Tuttnauer Vertical Autoclaves

Overall Dimensions (D x W x H)

1/2" 3-4 Bar, 60 L/min

1/2" 2-3 Bar

Withstanding temp. of 230F min.

NEW! 3870ELV Mobile Vertical Autoclave • No need to hook up to drain or compressed air, simply

manual fill the 28L reservoir (with mineral free water)

and start cycles.

• Only available in the 85L vertical system

• Wheels for easy mobility

• Built in printer w/ Bacsoft controls

Vertical Autoclaves� 10 set sterilization programs are: Glass, Plastic, Liquid

A, B, C, Vacuum test, Bio Hazard Liquid 1, 2, 3.

� Bacsoft software; easily store commonly used cycles

as well ad export history to USB

� General Feature: Temp range 105C to 138C,

Sterilization time range 1-99 min.

� The chamber is constructed of long lasting 316Ti

grade stainless steel with superior corrosion

resistance

� Autoclave automatically switches to standby mode if

no buttons or switches are operated for four hours

� 2 Flexible PT100 temperature sensors in the chamber

come with unit.

� Validation Port

� Factory set at 134C (273F) for instruments and at

121C for liquids and other materials

� Requires: Drain, tap water, compressed air for ELVC

units only, and mineral free water

Heidolph Tuttnauer Vertical Autoclaves

Part No. 023210745 3870ELV

Mobile (220v)

Page 5: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Heidolph Tuttnauer Autoclaves

Services

Preventative Maintenance (On Site or In House)

� Maintenance kit

� Replacement of: Chamber Brite, safety valve, door bellow, door

gasket, air relief valve, safety valve holder

� Labor

� 40% off parts and labor for the year of PM

� First three hours of Non PM labor is included

All Heidolph Tuttnauer sterilizers require general maintenance and cleaning. A sterilizer often requires

regulatory compliance at some local, state, or federal standards based on the application within the

operation of the unit. Our factory trained technicians are here to help provide basic product upkeep and to

help support your sterilizer through a variety of services offered below:

Validation

� All test cycles include (Temperature,

Pressure, Saturated Steam Time)

� Solenoid valves are checked for proper

operation

� Safety features are tested (4 parameters)

� Accuracy adjustments

� Extensive Reports, mapped at 6 positions,

accurate to .2C

� Warranty is extended an additional year

Description Value (varies per unit)

Chamber Brite (1 box of 10 Pkgs) $ 106.84

Safety Valve $ 106.66

Complete Door Bellow Kit $ 101.95

Door Gasket $ 300.00

Air Relief Valve $ 65.83

Safety Valve Holder $ 87.24

Items to the right are

replaced during

Preventative Maintenance

including other items

service tech recommends

IQ/OQ

� Documented proof that facilities and

equipment have been delivered/installed

in accordance with the requirements and

safety regulations stipulated in the design

qualifications.

� Consists of:

� IQ test plan

� IQ extensive report

� Installation

Large Capacity Autoclaves• 120L up to 950L Size Range • Compressed air, steam generator, and loading

carts offered with purchase • Sterilization of liquids, gravity cycles, pre vacuum

cycles, 2 test cycles

Page 6: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Heidolph Preferred Benchtop Shakers

6 specific motions - from one to three dimensional movements, and 3 different load capacities

Reax Top or Control (Vortex)

Multi Reax Titramax 100, 101 or 1000

Vibramax 100 or 110

Rotamax 120

Motion: Vibrating Vibrating Vibrating Vibrating Vibrating

Speed: (rpm)

0-2,500 150-2,000 150-1,350 150-1,350 20-300

• HeidolphVortexer

• Ideal for mixing samples in Eppendorftubes, vials and similar vessels

• Unique shaker accommodates up to 26 vessels with various diameters

• Allows for ridged to smooth dispersion of viscous media and solids

• 3 models to choose from

• Titramax 100 offers a 1.5 mm orbit

• Titramax 101 offers a 3.0 mm orbit designed for larger sample volumes

• Titramax 1000 allows for 6 microtiter plates

• Compact model = Vibramax 100 with a 2 kg load capacity

• Vibramax 110 has a shaking orbit of 1.5 mm for sensitive samples

• Accepts load capacitates of 2 kg.

• Space for 4 medium sized culture plates

• Shaking orbit of 20mm

Unimax 1010 or Unimax 2010

Promax 1020 or Promax 2020

Duomax 1030 Polymax 1040 or Polymax 2040

Reax (4options)

Motion: Orbital Reciprocating Rocking Wave Overhead

Speed: (rpm)

30-500Uni 2010: 20-400

30-250Pro 2020: 20-400

2-50 2-50 20-1001-16

• Offered in a 10mm shaking orbit or the larger 2010 model features a 20 mm orbit

• Built in process timer

• Designed especially for phase separations

• Stroke length of 32mm and 20mm with the Promax 2020

• Available in two different angle configurations

• Recommended for culture plates/bottles, media bottles and Erlenmeyer flasks

• 5 or 10 degree angle tilt

• Choose from 2 different tilt angles: 5 or 10

• Best for viscous media such as gels for electrophoresis

• Overheadshaking for 2-12 bottles

**Accessories for shakers are sold separately unless otherwise stated. Check out Heidolph’s Catalog/Shaker Section for accessories available or visit

www.HeidolphNA.com

Page 7: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Heidolph Peristaltic Pumps

Precise Dosing & Dispensing

PD 5001 PD 5006 PD 5101 PD 5106 PD 5201 PD 5206

PN (115V) 036150010 036150030 036150050 036150070 036150090 036150110

Flow rates single

channel pumps (ml) .8 - 790 3.6 - 3,900 .3 - 790 1.3 - 3,900 .3 - 790 1.3 - 3,900

Flow rates multi

channel pumps (ml) .005 - 320 .005 - 320 .005 - 320

Speed Range (rpm) 10 - 120 50 - 600 5 - 120 24 - 600 5 - 120 24 - 600

Speed Control analog analog digital digital digital digital

Direction of rotation CW/ CCW CW/ CCW CW/ CCW CW/ CCW CW/ CCW CW/ CCW

Digital Interface RS 232 RS 232

Flow rate indicator digital digital

Calibrate your flow

volume & flow rate

individually yes yes

Digital Read out of:

Speed, tubing diameter,

flow rate, dosing volume,

interval dosing, pause

function

Speed, tubing diameter,

flow rate, dosing

volume, interval dosing,

pause function

All Peristaltic pumps MUST be ordered with a pump head and/or adaptors, cassettes, and tubing for

complete working package. Sold separately. See complete catalog to spec out exact components.

Components needed for Multi Channel Components needed for Single Channel

� The PD series is self priming and comes without

any valve, thus providing care free operation

� Use a single channel pump head and upgrade to

multi channel in just minutes with a different

pump head

� All models feature a smooth start operation that

prevents spilling and splashing of media. The

speed will ramp up slowly until your set rpm has

been reached

� For use in cell biology, choose a pump head which

features convex rollers that do not squeeze the

tubing as would conventional rollers

Page 8: 4000.BioTools Flyer 2013.ppt - Fisher Scientificstatic.fishersci.com/cmsassets/downloads/segment/Scientific/pdf/... · HeidolphIn field Sales Contacts Regional Sales Manager -Eastern

Heidolph Presents:

Other Chemistry Tools

Heidolph North America

www.HeidolphNA.com

Elk Grove Village, IL 60007

Toll Free: 866-650-9604

Fax: 224-265-9611

[email protected]

Pair your Tuttnauer

Autoclave purchase with

any of our Ultrasonic

baths and/ or Benchtop

Water Distillers.

Powdersafe Bulk Handling Enclosures

Bulk handling enclosures were designed in response to the need for effective containment during bulk powder manipulation without the expense or space requirements of a traditional walk in or free standing enclosure • Disposal port for weighing vessels• Safe change filter change out• AirSAFE automatic safety controller

All measurements provided are (w x d x h) inches

Silent Crusher S Silent Crusher M

PN (115V) 036170000 036170040

Speed

(rpm) 75,000 26,000

Sample

Size .8 ml - 10 ml .8 -2,000 ml

Viscosity 5,000 mpas 5,000 mpas

PN Internal Size External Size

035110880 47 x 29 x 35 48 x 36 x 94

035110890 59 x 29 x 35 71 x 29 x 35

035110900 71 x 29 x 35 72 x 36 x 94

� 4 Models to choose from

� Built in heater (“H” models) for

added sample processing & cleaning

power

� High efficiently 60 kHz

� Tank Capacity from 3.4 L to 12.7 L

� 4 Models to choose from

� Distillate capacity from 1 gal to 12 gal

� Effectively removes most tap water impurities

� Easy to remove boiler for manual fill- no

water hook up

� Rust proof stainless steel condenser