4-ld1187_gb_3+4

4

Upload: luyckxj

Post on 05-Sep-2015

1.196 views

Category:

Documents


167 download

DESCRIPTION

Weatherstation Digi-Tech 4-LD1187-4 Inter-Quartz GmbH

TRANSCRIPT

  • Wireless

    Temperature StationDCF-77 radio-controlled time

    digi-tech

    4-LD1187GB

    digi-tech gmbh

    Valterweg 27A

    65817 Eppstein

    GERMANY

    Table of Contents

    Temperature Station Controls

    LCD display

    Sensor

    Included

    Specifications

    Instruction manual

    Setting degrees Celsius or

    Fahrenheit

    Manual setting

    Time zone setting

    Alarm function

    Setting the alarm A1 & A2

    Activating / deactivating the

    alarm

    Stopping the alarm

    Viewing the alarm times

    Snooze function

    Minimum and maximum

    temperatures

    Temperature display

    Battery low indicator / battery

    replacement

    Information about the outdoor

    sensor

    Possible problems

    Warranty

    Order service

    ..1

    ..1

    ..1

    ..2

    ..2

    ..2-3

    ..3

    .3

    ..3

    ..3

    ..3

    ..3

    ..4

    ..4

    ..4

    ..4

    ..4

    ..4

    ..5

    ..5

    ..6

    ..6

    RADIO CONTROLLED

    TIME

    433MHz

    WIRELESS THERMOMETER

    C

    LH EA NN

    CLOCK

    ALARM

    SELECT

    SET/

    RESET

    Zz

  • Warranty:

    This product has a 5 year warranty. The warranty period

    starts on the day of purchase (sales receipt). Within this

    period we repair any defects due to material or production

    fault free-of-charge. This does not include batteries. For

    any defects which are due to improper use, for example in

    cases of dropping, hitting, contact with water, the right to

    claim under warranty ceases to apply.

    Free service hotline:

    www.inter-quartz.de

    00800 5515 6616

    digi-tech , Valterweg 27A, DE-65817 Eppstein

    4-LD1187

    This product complies with the essential requirements of

    3 and the other relevant provisions of the FTEG (Article 3

    of the R&TTE Directive), when used for its intended

    purpose. The certificate of conformity can be obtained

    here:

    [email protected]

    Order service:

    Up to 3 sensors may be connected to your temperature

    station. One sensor is included with the temperature

    station. Additional temperature stations may be purchased

    by Fax (0049 6198 5770 99) or on the internet at

    www.inter-quartz.de

    The price for 1 sensor is EUR 5,00; 2 sensors EUR 10,00

    incl. instruction manual and packaging. Additional charges

    for shipping and cash on delivery will apply.

    -6--1-

    Temperature station controls:

    SELECT-button

    - set the temperature display to C or F

    (In combination with "SET/RESET")

    - maximum and minimum temperatures

    SET/RESET-button

    - reset maximum and minimum temperatures

    - activate / deactivate the 2 alarm times

    CLOCK-button

    - set the time and calendar

    - read the second time zone

    - set the second time

    ALARM-button

    - show set alarm time

    - set alarm / alarm times

    Zz / CHANNEL-button

    - use snooze function

    - select the channels of the connected sensors (1-3)

    - activate automatic sensor cycling

    LCD display:

    D1: outdoor temperature in C or F

    min/max outdoor temperature

    outdoor sensor battery indicator

    temperature trend indicator

    (rising, constant, dropping)

    D2: indoor temperature in C or F

    min/max indoor temperature

    temperature station battery indicator

    D3: time display 12/24 hour mode

    hour and minute display

    Zz - snooze function

    D4: 2 alarm times, second time zone

    DCF77 signal reception

    signal scan (= blinking symbol)

    seconds display

    D5: date display: day, month, weekday display

    in German (GE), English (EN), French (FR),

    Italian(IT), Spanish (SP)

    Sensor:

    (A) Hole for wall mounting

    (B) "TX/RESET" button (to press this button, the screws

    on the back side of the sensor must be unscrewed and the

    rear cover removed).

    Press "TX/RESET" to check signal transmission and

    restart the sensor.

    (C) Folding stand for table top setup of the sensor. To wall

    mount the sensor with the included double-sided tape

    please first remove the stand by compressing the forked

    end and pulling it off the sensor.

    (A)

    (B)

    (C)

    To insert batteries into the sensor the 4 screws on the back side of the case

    must be unscrewed and the rear case cover must be removed.

    dig

    i-te

    ch

    4-L

    D118

    7

    RADIO CONTROLLED

    TIME

    433MHz

    WIRELESS THERMOMETER

    C

    LH EA NN

    CLOCK

    ALARM

    SELECT

    SET/

    RESET

    Zz

  • -2-

    Information about the outdoor sensor:

    The sensor is intended for wallmounting or tabletop use

    and can be glued to a dry, clean surface with the included

    double-sided tape (yellow side).

    To test the signal transmission of the sensor, press the

    "TX/RESET" button (B) on the back side of the sensor.

    Unscrew the 4 screws on the back side of the sensor and

    remove the back cover. Press the "TX/RESET" button for

    3 seconds to restart the sensor. The sensor must now be

    registered at the station.

    The sensor transmits the temperature signal on the

    frequency 433MHz and has a range of approx. 30m

    outdoors. The transmission functions best if no obstacles

    are between the station and the sensor (examples:

    Thermopen glass, metal beams, brick walls).

    If your station cannot receive the outdoor temperature,

    please move the sensor closer to the station. It may also

    become necessary to replace the batteries.

    Possible problems:

    The clock does not receive the time signal:

    Please move your station to another position and consider

    that an electrical appliance such as a PC, telephone, radio or

    TV may cause electromagnetic interference that could

    influence the reception of the time signal.

    Other possible interferences for the reception: strong

    building materials (metal), large landmasses (hills),

    atmospheric interference.

    It may also be necessary to replace the batteries.

    If radio-signal reception is not possible at all, please set

    the clock manually.

    The outdoor temperature is not displayed:

    Press and hold the "Zz/CHANNEL" button for 3 seconds

    and then wait for 2 or 3 minutes.

    Please position the sensor in a roofed area. It is weather

    resistant but it should not come into direct contact with

    water or sunlight.

    The outdoor temperature is often lost:

    Reduce the distance between the station and the sensor

    (30m max. with clear line of sight and no obstacles)

    Check the distance to possible sources of interference (at

    least 1.5m to any phones, TV, radio computers etc.

    Other appliances in neighboring houses that also use the

    433MHz frequency may cause problems.

    Check the placement of your station (proximity to metal

    building parts, metal doors, concrete ie. cellar large highrise

    building)

    Should these measures remain unsuccessful please restart

    both units as described on page 2.

    -5-

    Dear Customer,

    congratulations on your purchase of this wireless

    temperature station.

    The temperature station is intended for wallmounting or

    tabletop use.

    Please read the instruction manual prior to use.

    Included:

    -1 temperature station incl. stand

    -1 outdoor sensor

    -2x 1,5V AA batteries

    -2x 1,5V AAA batteries

    -1x double-sided tape

    -1x instruction manual

    Specifications:

    Indoor temperature range:

    0C to +50C with 0,1C resolution

    Outdoor temperature range:

    -30 C to +70C with 0,1C resolution

    Precision: +/ - 1C

    Transmission range: max. 30m in open terrain

    3 Channels: connect up to 3 sensors

    Temperature transmission frequency:

    wireless transmission at 433MHz

    Time signal: DCF 77 radio signal

    Instruction manual:

    Your temperature station should not be exposed to

    humiditiy or direct sunlight.

    Please remove the battery interrupter first to activate your

    temperature station.

    The unit is now operational.

    During the first 4-5 minutes your temperature station will

    attempt to receive the signal from the outdoor sensor. The

    radio waves in the display will blink (D1) adjacent to the

    channel display. The radio tower will appear without radio

    waves.

    Position the sensor and the station side by side. Now

    insert the batteries into the sensor within the next 2

    minutes. Unscrew the 4 screws on the back side of the

    sensor, remove the back cover and insert the batteries in

    the correct polarity. Please take care not to remove the

    rubber gasket that runs along the outside of the case.

    Replace the back cover and tighten the 4 screws.

    Channel 1 will now be registered and the outdoor

    temperature will appear in the display (D1). Channels 2

    and 3 may be set in the same way, if you wish to install

    additional outdoor sensors.

    A registered Channel will not receive any additional

    sensors.

    If you have multiple sensors connected to your station,

    you may cycle through them by pressing the

    "Zz/CHANNEL" button. When a round arrow is displayed

    the station will autocycle through all available sensors.

    -Your temperature station will now attempt to receive the

    radio time signal and the reception signal will appear

    partially on the display (D4).

  • Stopping the alarm:

    When the alarm sounds, it may be deactivated by

    pressing "ALARM". The alarm will switch off automatically

    after 5 minutes if no button is pressed.

    To completely deactivate the alarm, press "SET/RESET"

    repeatedly until the bell symbol for the alarm you wish to

    deactivate disappears. The bell symbols on the display

    D4 will show activated alarm times.

    Viewing the alarm times:

    To view the first alarm time press the "ALARM" button 1x.

    To view the second alarm time, press "ALARM" again

    and return to normal time display by pressing "ALARM"

    once more (the display automatically returns to normal

    time if no button is pressed for more than 8 seconds).

    Snooze function:

    To activate the snooze function press "Zz/CHANNEL" upon

    hearing the alarm. The bell symbol and Zz on the display will

    blink. After 5 minutes the alarm will sound again.

    To deactivate the snooze function, press "SELECT"; The

    bell symbol will stop blinking.

    Temperature display:

    The arrow in the display (D1) shows if the outdoor

    temperature has risen within the last hour by more than 1

    degree (arrow points upward), fallen (arrow points

    downward) or remained constant (arrow straight).

    Battery low indicator / battery replacement:

    The battery low indicator will appear in the display (D1) when

    the batteries of the sensor need to be replaced. Unscrew the

    4 screws on the back side of the sensor, remove the back

    cover and insert 2 AAA batteries in the correct polarity.

    Please take care not to remove the rubber gasket that runs

    along the outside of the case. Replace the back cover and

    tighten the 4 screws.

    To register the sensor please press "Zz/CHANNEL" for 3

    seconds until flashing dashes appear in place of the outside

    temperature and channel number. The station will now

    attempt to register the sensor.

    Minimum and maximum temperatures:

    Once set up, your station seperately saves the maximum

    and minimum temperatures for each sensor and the

    station itself. These values my be reset at any time.

    -Pressing "SELECT" 1x displays the stored max.

    temperature

    -Pressing "SELECT" 2x displays the stored min.

    temperature

    -Pressing "SELECT" 3x returns to normals time display

    -To delete a max. or min. temperature, press

    "SET/RESET" while viewing the temperature. The station

    will return to normal time display mode.

    The battery symbol in row 2 (D2) displays the battery power

    of the station. To replace the batteries, open the battery

    compartment and insert new batteries (2 x 1.5V AA) in the

    correct polarity.

    Please dispose of the batteries in the appropriate

    containers. Batteries should not be disposed of in the

    regular trash.

    -4-

    Attention:

    During this operation, no other functions may be used.

    Depending on your distance to the transmitting station,

    reception of the signal may take from 5 minutes to several

    hours.

    with

    radio waves

    Should your clock not set itself within 5 minutes, please try

    again at a different location or set the clock manually.

    Setting degrees Celsius or Fahrenheit:

    Press and hold "SELECT" for 3 seconds.

    Press "SET/RESET" to set C (Celsius) or F (Fahrenheit).

    Confirm your selection by pressing "SELECT".

    Manual setting:

    Press and hold "CLOCK" for 3 seconds.

    Press "SET/RESET" to select 12/24 hour time display.

    Activate the setting by pressing "CLOCK" again. The

    weekday language (GE=German, FR=French, IT=Italian,

    SP=Spanish, En=English), second time zone, hours,

    minutes, seconds, year, month and day may be set in the

    same manner.

    Press "CLOCK" again to return to normal time display.

    Time zone setting:

    If you wish to see the current time for another time zone in

    the display, you may store this time zone. Please enter the

    time difference in hours between your time zone and the

    second time zone you wish store. In the example of Los

    Angeles the setting would be -10 hours.

    To see the 2. time zone, press "CLOCK". The 2. time

    zone will appear on the display (D3) with the word "Zone".

    To return to the normal time zone display press "CLOCK".

    Alarm function:

    Setting the alarm A1 & A2:

    2 separate alarms may be set on your temperature

    station.

    Press and hold "ALARM" for 3 seconds.

    Use "SET/RESET" to set the hours for alarm 1 and press

    "ALARM" to confirm your selection.

    Set the minutes by pressing "SET/RESET"

    After confirming your setting with "ALARM", the setting of

    the second alarm time is started.

    Attention: No alarm may be set for the second time zone!

    Activating / deactivating the alarm:

    To activate the alarm times, repeatedly press

    "SET/RESET". The bell symbols on the display D4 will

    show activated alarm times.

    Upon successful reception the radio antenna symbol

    will appear on the display and the correct

    time and date will be set automatically. If the radio antenna

    symbol does not appear, radio reception is currently not

    possible.

    -3-

    Seite1Seite2Seite3Seite4