Confidential Page 1 of 14 Product Change Notice Huawei PCN SRAN-20120010 (OMB Ver.A Cabinet EOM Notice) 0 Abstract Manufacture of OMB Ver.A cabinets and components intended for the Distributed Base Station 3900 (DBS3900) will be discontinued. OMB Ver.C cabinets and components will substitute for OMB Ver.A cabinets and components respectively for sales. This change notice is for customers who use OMB Ver.A cabinets and components intended for the DBS3900. OMB stands for outdoor mini box. The last-buy date is December 31, 2013. The last supply date is June 30, 2014. The heat exchange unit type As (HEUAs) of OMB Ver.A cabinets can be substituted by the heat exchange unit type Bs (HEUBs) of OMB Ver.C cabinets. Therefore, the manufacture of HEUAs will be discontinued starting from December 31, 2013 together with OMB Ver.A cabinets. The last supply date is June 30, 2014. For the last-buy dates for other components that do not have substitutes, see the DBS3900 life cycle milestone bulletin. The details are as follows. 1 Supplier Information Huawei Technologies Co., Ltd. 2 PCN Information PCN No. SRAN-20120010 PCN Revision Rev:01 PCN Classification B Milestone Issue date The day when the product change notice (PCN) is officially issued December 31, 2012 Implementation date The day when the new part is available/orderable December 31, 2012 End of marketing date The day when purchase orders (POs) for the old part are no longer accepted December 31, 2013 End of manufacturing date The day when the old part is no longer delivered June 30, 2014

Upload: tarek-el-deghedy

Post on 10-Apr-2016

119 views

Category:

Documents


9 download

DESCRIPTION

OMB Installation

TRANSCRIPT

Confidential Page 1 of 14

Product Change Notice

Huawei PCN SRAN-20120010 (OMB Ver.A Cabinet EOM Notice)

0 Abstract

Manufacture of OMB Ver.A cabinets and components intended for the Distributed Base Station 3900 (DBS3900)

will be discontinued. OMB Ver.C cabinets and components will substitute for OMB Ver.A cabinets and

components respectively for sales. This change notice is for customers who use OMB Ver.A cabinets and

components intended for the DBS3900. OMB stands for outdoor mini box.

The last-buy date is December 31, 2013. The last supply date is June 30, 2014.

The heat exchange unit type As (HEUAs) of OMB Ver.A cabinets can be substituted by the heat exchange unit

type Bs (HEUBs) of OMB Ver.C cabinets. Therefore, the manufacture of HEUAs will be discontinued starting

from December 31, 2013 together with OMB Ver.A cabinets. The last supply date is June 30, 2014. For the

last-buy dates for other components that do not have substitutes, see the DBS3900 life cycle milestone bulletin.

The details are as follows.

1 Supplier Information

Huawei Technologies Co., Ltd.

2 PCN Information

PCN No. SRAN-20120010

PCN Revision Rev:01

PCN Classification B

Milestone Issue date The day when the product change

notice (PCN) is officially issued December 31, 2012

Implementation

date The day when the new part is

available/orderable December 31, 2012

End of marketing

date The day when purchase orders (POs)

for the old part are no longer accepted December 31, 2013

End of

manufacturing

date

The day when the old part is no longer

delivered June 30, 2014

Confidential Page 2 of 14

Product Change Notice

End of service

support date The day when service support is no

longer provided See the contract.

3 System and Product Affected

Major System Subsystem Hardware Software Firmware Plug-in

DBS3900 OMB cabinet Y N N N

4 Associated Change

None.

5 BOM Change

New BOM Name Old BOM Name Complete Substitution

02113690 OMB Ver.C cabinet

(AC) 02112832 OMB Ver.A cabinet (AC) Yes

02113691 OMB Ver.C cabinet

(DC) 02112833 OMB Ver.A cabinet (DC) Yes

03021MUP HEUB 03020HJV HEUA Yes (note 1)

02120719 FAU01D-01 02120496 Internal fan unit N/A (note 2)

02120497 External fan unit N/A (note 2)

02310MCA ETP48100-A1 02400421 EPS30-4815AF N/A (note 2)

02310HBJ R4850G2 02130617 GERM4815 N/A (note 2)

02310LYP PMU 11A 02316005 EPMU03 N/A (note 2)

02120722 PDU10D-01 02120494 DC power distribution unit

(PDU) N/A (note 2)

19020168 SPD40/S 02120493 Surge protective device

(SPD) N/A (note 2)

The HEUBs of OMB Ver.C cabinets can totally substitute the HEUAs of OMB Ver.A cabinets. Therefore, the

manufacture of HEUAs will be discontinued starting from December 31, 2013 together with OMB Ver.A cabinets.

Except the HEUAs, other components of OMB Ver.A cabinets cannot be substituted by the components of OMB

Ver.C cabinets. Therefore, the components of OMB Ver.A cabinets and OMB Ver.C cabinets need to be stored

respectively as the spare parts for the OMBs used on the live network.

Confidential Page 3 of 14

Product Change Notice

6 Classification Substantiation

1. Manufacture of OMB Ver.A cabinets and components will be discontinued. OMB Ver.C cabinets and

components will substitute for OMB Ver.A cabinets and components respectively for sales.

2. OMB Ver.C cabinets employ new components and deliver enhanced performance and high integration.

By supporting more types of RRUs with higher power, OMB Ver.C increases the heat dissipation

capability. Embedded with baseband units (BBUs), OMB Ver.C cabinets have a maximum power of

450 W. The AC-DC power system capacity increases and the conversion efficiency reaches 96%.

Such features enable the OMB to consume less power and deliver more powerful DC power

distribution capability. In addition, OMB Ver.C cabinets can be identified remotely, which facilitates

asset management and fault diagnosis.

7 Software Version Supporting OMB Ver.C Configuration

Single radio access network 8.0 (SRAN8.0): can automatically identify the earlier and latest versions

of the AC-DC power system in the OMB, ensuring the consistency between the actual power supply

unit (PSU) slot number and the slot number displayed on the M2000.

SRAN6.0 and SRAN7.0: cannot identify the latest version of the AC-DC power system. If OMB

Ver.C is used, the PSU slot number displayed on the M2000 is inconsistent with the actual PSU slot

number.

OMB Ver.A OMB Ver.C

Physical slots

for the AC-DC

power system

SRAN6.0

M2000 display

SRAN7.0

M2000 display

SRAN8.0

M2000 display

Confidential Page 4 of 14

Product Change Notice

8 Change Description

8.1 Overall Change Description for OMB Ver.C

Figure 1 OMB Ver.C (AC) components

Figure 2 OMB Ver.C (DC) components

Confidential Page 5 of 14

Product Change Notice

8.1.1 OMB Ver.C Cabinet

OMB Ver.C cabinets have the same internal structure as OMB Ver.A cabinets on the live network. While

retaining all the functions of OMB Ver.A cabinets, OMB Ver.C cabinets provide better results in supporting

various RRUs, heat dissipation, power system capacity, conversion efficiency, DC power distribution

capacity, remote identification, and component miniaturization.

Enhanced Performance Ver.A Ver.C

Heat dissipation Maximum BBU power: 250 W

Supporting one 1x80 W RRU

Maximum BBU power: 450 W

Supporting six 2x60 W RRUs

AC-DC power system

capacity 800 W 6000 W

PSU conversion

efficiency 90% 96%

PDU DC power

distribution capacity 2 outputs, 12 A and 4 A respectively 10 outputs, 30 A for each

Remote identification Not supported The OMB cabinet version information can

be remotely obtained on the operation and

maintenance center (OMC), which

facilitates asset management and fault

diagnosis.

SPD miniaturization 391 mm x 55 mm x 54 mm 75 mm x 48 mm x 60 mm

8.1.2 Changes in OMB Appearance, Dimensions, and Installation Space

OMB Ver.C has different appearance and dimensions from OMB Ver.A, and the installation space also

changes.

Figure 3 Appearance and dimensions differences between OMB Ver.A and OMB Ver.C

Confidential Page 6 of 14

Product Change Notice

Figure 4 Installation space difference between OMB Ver.A and OMB Ver.C

Version OMB Dimensions OMB Installation Space

OMB Ver.A 600 mm x 240 mm x 390 mm (H x W x D) See Figure 4 .

OMB Ver.C 600 mm x 240 mm x 430 mm (H x W x D)

8.2 OMB Ver.C Component Changes

8.2.1 New Electronic Label Function

In OMB Ver.C, the monitoring board HEUBs in OMB Ver.C cabinets are configured with the remote

identification function. The HEUBs in OMB Ver.C can totally substitute the HEUAs in OMB Ver.A.

The newly added electronic label unit (ELU) is installed in the upper part on the right of the OMB cabinet

door. The ELU reports cabinet version information, which facilitates asset management and fault diagnosis.

Confidential Page 7 of 14

Product Change Notice

Figure 5 Change from the HEUA to the HEUB

Figure 6 ELU

Name Version ELU Function

HEUA OMB Ver.A No

HEUB OMB Ver.C Yes

8.2.2 Fan Assembly Change

Use the FAU01D-01 as both the internal and external fan units in the OMB cabinet, because the

FAU01D-01 helps improve the heat dissipation capability of the OMB cabinet and raise the maximum

BBU power to 450 W.

Figure 7 Change in the internal fan unit

Confidential Page 8 of 14

Product Change Notice

Figure 8 Change in the external fan unit

Name Version BBU Power RRU Type

Internal fan unit OMB Ver.A 250 W One 1 x 80 W

External fan unit OMB Ver.A

FAU01D-01 OMB Ver.C 450 W Six 2 x 60 W

8.2.3 Change in the OMB Cabinet Cable Outlet Structure

The OMB cabinet cable outlet structure changes to support the outlet of more power cables with greater

diameters.

Hole Diameter on Modules (mm)

Suitable Cable Diameter (mm)

Ver.A

Left Module

Ver.C

Left Module

Ver.A

Right Module

Ver.C

Right Module

φ18 φ18–φ22 1

φ13 φ13–φ18 1

φ11 φ11–φ14 4 6

φ9 φ9–φ10

φ8 φ8 2 6 4

φ6 φ6 7 15

φ4 φ4 2

φ2.5 φ2.5 1 4

Confidential Page 9 of 14

Product Change Notice

Figure 9 Change in the OMB cabinet cable outlet structure

8.2.4 Change in the AC-DC Power System (Component of the OMB [AC]))

Capacity of the AC-DC power system in the OMB cabinet increases from 800 W to 6000 W.

Figure 10 Change in the AC-DC power system

Version Name Power System Capacity Maximum Number of PSUs

OMB Ver.A EPS30-4815AF 800 W 1

OMB Ver.C ETP48100-A1 6000 W 2

The new PSU (R4850G2) increases the conversion efficiency from 90% to 96%, consuming less

power.

Figure 11 PSU change

Confidential Page 10 of 14

Product Change Notice

Version PSU name PSU Capacity PSU Efficiency

OMB Ver.A GERM4815 800 W/PCS 90%

OMB Ver.C R4850G2 3000 W/PCS 96%

The power monitoring unit (PMU) also changes from the EPMU03 to the PMU 11A.

Figure 12 PMU change

Version Name Functions

OMB Ver.A EPMU03 The PSU GERM4815 of OMB Ver.A is managed.

OMB Ver.C PMU 11A The PSU R4850G2 of OMB Ver.C is managed.

The AC-DC power system of OMB Ver.C delivers greater output currents.

Figure 13 DC output change

Version Name DC Power Distribution Capability

OMB Ver.A EPS30-4815AF 1 x 10 A (fuse) + 1 x 20 A (fuse)

OMB Ver.C ETP48100-A1 1 x 100 A (circuit breaker) + 1 x 100 A (circuit breaker)

The corresponding AC power user interface (UI) also changes.

Confidential Page 11 of 14

Product Change Notice

Input Voltage Version Power UI

Single-phase 220 V

AC OMB Ver.A 10 A/1P (2.5 mm

2 cable)

OMB Ver.C 16 A/1P (2.5 mm2 cable)

Dual–live wire 110 V

AC OMB Ver.A 10 A/2P (2.5 mm

2 cable)

OMB Ver.C 16 A/2P (2.5 mm2 cable)

8.2.5 Change in the DC SPD (Component of the OMB [AC])

In OMB Ver.C (AC), the PDU10D-01 is used for DC power distribution, which increases the DC outputs

from 2 (12 A and 4 A respectively) to 10 (30 A for each).

Figure 14 Change in the DC SPD (component of the OMB [AC])

Version Name DC Power Distribution Capability

OMB Ver.A DC PDU 1 x 12 A (circuit breaker) + 1 x 4 A (circuit breaker)

OMB Ver.C PDU10D-01 10 x 30 A (fuse)

8.2.6 SPD Change (Component of the OMB [AC])

The SPD40/S is used as the AC SPD. The SPD40/S occupies less area while enduring a maximum of 40 kA

current.

Confidential Page 12 of 14

Product Change Notice

Figure 15 SPD change

(AC Surge protection box: SPD)

Version Name Surge Protection Specifications

Dimensions

OMB Ver.A AC SPD 40 kA 405 mm x 55 mm x 53.5 mm (H x W x D)

OMB Ver.C SPD40/S 40 kA 75 mm x 48 mm x 60 mm (H x W x D)

8.2.7 Change in the DC SPD (Component of the OMB [DC])

In OMB Ver.C (DC), the PDU10D-01 substitutes the direct current distribution unit-03B (DCDU-03B) to

distribute DC power.

The DC power distribution capability greatly improves.

Figure 16 Change in the DC SPD (component of the OMB [DC])

Confidential Page 13 of 14

Product Change Notice

Version Name DC Power Distribution Capability

OMB Ver.A DCDU-03B 3 x 12 A (circuit breaker) + 6 x 20 A (circuit breaker)

OMB Ver.C PDU10D-01 10 x 30 A (fuse)

The corresponding DC power UI also changes.

Input Voltage Version Power UI

–48 V OMB Ver.A 16 A/1P (4 mm2 cable)

OMB Ver.C 25 A/1P (4 mm2 cable)

9 Effect of Change

The following table lists the effect of the changes on typical aspects.

Safety Fire Service Communication

No No Yes

The installation space for

OMB Ver.C needs to

change. For details, see

section 8.1.2 "Changes in

OMB Appearance,

Dimensions, and Installation

SpaceError! No bookmark

name given.."

No

Maintenance Reliability Power Traffic

Yes

1) OMB Ver.C supports remote

cabinet identification, which

facilitates asset management

and fault diagnosis.

2) The spare parts for OMB

Ver.C differ from those for

OMB Ver.A. Therefore, their

components should be stored

respectively as the spare parts

for the OMBs used on the live

network.

No Yes

The power distribution

capability of OMB Ver.C

increases.

Yes

OMB Ver.C supports

higher service capacity

configuration,

increasing the data

traffic.

Confidential Page 14 of 14

Product Change Notice

10 Document Affected

The DBS3900 Product Description and DBS3900 User Guide are updated.