3g huawei capacity parameter&counter from m2000
TRANSCRIPT
-
3G Huawei Capacity Parameter&Counter From M2000
Prepared by HU MEI
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Login to M2000Click ContinueSelect NEO-RWG-OM and click Connect
Network and Technology, MaxisPage *
Login to M2000Click OKClick Login
Network and Technology, MaxisPage *
Login to M2000SUCCESSFUL
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Site statusDouble Click Main TopologyNew tab Main Topology
Network and Technology, MaxisPage *
Site statusPress Ctrl+F and fill in the search content with 4 LRD Click SearchDouble Click Site Name
Network and Technology, MaxisPage *
Site statusSite DownHealthyCritical AlarmMajor AlarmMinor Alarm
Network and Technology, MaxisPage *
View alarm eventPoint to the site and right click, then select Current Alarm
Network and Technology, MaxisPage *
View alarm eventCurrent Alarm listAlarm DetailAlarm list:-\\sgbsvc112\SHARE06\10_Project Management\GABS KV\01 Huawei docs\Reference Documents\BSC6900 UMTS\BSC6900 UMTS V900R014C00SPC500 Alarm Reference
Network and Technology, MaxisPage *
RNC&BBU typeRNC BBU typeBBU type:-\\sgbsvc113\SHARE07\NEO\Capacity Management\06 Triggering\11 KV & OKV Capacity Analysis\02 KV Triggering\M2000\Node B Type and Software\
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Site informationPoint to the site and right click, then select MML Command
Network and Technology, MaxisPage *
Site informationType DSP CELLCFG and click Execute(F9)DSP CELLCFGSectorCell IDUL Frequency ChannelDL Frequency Channel
Network and Technology, MaxisPage *
Site informationDSP CELLCFGScrambling CodePower Transmit(43dBm)
UL Frequency ChannelDL Frequency Channel1st carrier (W2100)9687106372nd carrier (W2100)9712106623rd carrier (W2100)9736106864th carrier (W900)27142939
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Capacity Parameter (IUB E1 site)DSP IMAGRP6 active E1Type DSP IMAGRP and click Execute(F9)
Network and Technology, MaxisPage *
Capacity Parameter (IUB IP site)DSP IMAGRPIf IP site, will display error message aboveE1/IP site list:-\\sgbsvc113\SHARE07\NEO\Capacity Management\06 Triggering\11 KV & OKV Capacity Analysis\02 KV Triggering\M2000\IUB&IP\
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE hardware)DSP BRD4 WBBP card and 1 UTRP cardType DSP BRD and click Execute(F9)
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE hardware)DSP BRDMFRINFOType DSP BRDMFRINFO and click Execute(F9)Type of WBBP card (B4/D2)
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE software)Click Performance and Query ResultDouble click CE license under hchuac userClick Condition
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE software)Select All in SubareaType Site NameClick the Site Name and Move to Selected Object
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE software)Click OtherSelect the date&timeClick Query
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB CE software)CE Uplink and CE DownlinkCE license:-\\sgbsvc113\SHARE07\NEO\Capacity Management\06 Triggering\11 KV & OKV Capacity Analysis\02 KV Triggering\M2000\CE Licence\
CE Hardware(no. of WBBP card)CE Software (License)138427683115241536
Network and Technology, MaxisPage *
Capacity Parameter (Non-IUB Power/Code)Type DSP CELLCFG and click Execute(F9)DSP CELLCFG2nd carrier1st carrier
UL Frequency ChannelDL Frequency Channel1st carrier (W2100)9687106372nd carrier (W2100)9712106623rd carrier (W2100)9736106864th carrier (W900)27142939
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Capacity Counter/StatClick Performance and Query ResultDouble click RRC,CS,PS POWER under hchuac userClick Condition
Network and Technology, MaxisPage *
Capacity Counter/StatSelect All in SubareaType Site NameClick the Site Name and Move to Selected Object
Network and Technology, MaxisPage *
Capacity Counter/StatClick OtherSelect the date&timeClick Query
Network and Technology, MaxisPage *
Capacity Counter/StatClick Line chart
Network and Technology, MaxisPage *
Capacity Counter/StatClick the cellClick the counter
Network and Technology, MaxisPage *
Capacity Counter/StatOther counter ???Click Condition
Network and Technology, MaxisPage *
Capacity Counter/StatClick Object typeType the counter nameClick the counter name and Move to Selected Counter
Network and Technology, MaxisPage *
Capacity Counter/StatClick the counter
-
ContentSite statusSite informationCapacity parameter3.1IUB (E1/IP)3.2Non-IUB3.2.1CE (Hardware,Software)3.2.2Power,Code (Carrier)Capacity counter/stat
Network and Technology, MaxisPage *
Reference\\sgbsvc112\SHARE06\10_Project Management\GABS KV\01 Huawei docs\Reference Documents\BSC6900 UMTSAlarm ReferenceMML commandParameterPerformance counter
Network and Technology, MaxisPage *
Q & A
Network and Technology, MaxisPage *
Q&ASyazul: What is the ICON when the site was down and has critical alam?Answer: The ICON will be red colour and a cross symbol at top left corner. For example:- TPCAPU
Network and Technology, MaxisPage *
Q&ADavid: using DSP BRD will show the hardware information for ****MU and 2nd logical site together?Answer:
The hardware information would not show together if you use once MML command.For example: -If require to show MU and MW site, you need to use twice MML command.
Select ****MU and execute the DSP BRD commandSelect ****MG and execute the DSP BRD command
Network and Technology, MaxisPage *
Q&AJimmy: DBS3900 is single RAN site?Answer:
DBS3900 is single RAN capable site.
Network and Technology, MaxisPage *
Q&AEverlyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3800)Click Report and NE ReportSelect DBS3800Click OK
Network and Technology, MaxisPage *
Q&AEverlyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3800)Click OK
Network and Technology, MaxisPage *
Q&AEverlyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3800)Click SaveAll site with DBS3800 show in NE Report
Network and Technology, MaxisPage *
Q&AEverlyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3800)Choose the locationInsert the file nameClick SaveBBU TYPE(DBS3800) SAVED
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3900)Click Report and NE ReportSelect DBS3900Click OK
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3900)Click OK
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3900)Click SaveAll site with DBS3900 show in NE Report
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
BBU type (DBS3900)Choose the locationInsert the file nameClick SaveBBU TYPE(DBS3900) SAVED
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteClick Performance and Query ResultDouble click IUB under hchuac userClick Condition
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteSelect IP in SubareaClick All and Move to Selected Object
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteClick OtherSelect the date&timeClick Query
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteAll site and E1/IP information in the IP selected show in the resultClick Save
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteInsert the file nameClick SaveChoose the locationE1/IP site SAVED
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.
E1/IP siteExample:
VS.ATMDlTotal.1 (kbit/s) = 11424VS.ATMDlTotal.2 (kbit/s) = 3808
Total E1 = (11424/1904)+(3808/1904) = 8 active E1 only Remark: E1 down would not capture in the counter
Counter NameE1/IP siteNo. of E1VS.IPDlTotal.1 (kbit/s)IP site-VS.ATMDlTotal.1 (kbit/s)E1 site*****/1904VS.ATMDlTotal.2 (kbit/s)E1 site*****/1904
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.CE hardware cant dump, using MML command only. CE licenseClick Performance and Query ResultDouble click CE license under hchuac userClick Condition
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.CE hardware cant dump, using MML command only. CE licenseSelect IP in SubareaClick All and Move to Selected Object
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.CE hardware cant dump, using MML command only. CE licenseClick OtherSelect the date&timeClick Query
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.CE hardware cant dump, using MML command only. CE licenseAll site and CE license in the IP selected show in the resultClick Save
Network and Technology, MaxisPage *
Q&AEvelyn: How to dump parameter for all site?Answer: Different parameter different method.CE hardware cant dump, using MML command only. CE licenseInsert the file nameClick SaveCE LICENSE SAVEDChoose the location
Network and Technology, MaxisPage *
Q&AJimmy: How to check 2G site in M2000?Answer:Checking 2G site in M2000 is a bit different compare with 3G site.All the 2G information, please refer to the document in share folder below:-
\\sgbsvc112\SHARE06\10_Project Management\GABS KV\01 Huawei docs\Reference Documents\BSC6900 GSM\
Alarm ReferenceMML commandParameterPerformance counter
Network and Technology, MaxisPage *
Thank You