3d nerve marking imaging 11 - dolphin imag resolution, ... imaging 11.8 all trademarks are ......

6
Dolphin 3D The Dolphin 3D software module is a powerful tool that makes processing 3D data extremely simple, enabling dental specialists from a wide variety of disciplines to diagnose, plan treatment, document and present cases. Dolphin 3D allows visualization and analysis of craniofacial anatomy from data produced by cone beam computed tomography (CBCT), MRI, medical CT and 3D facial camera systems. Dolphin Imaging software is an FDA-cleared Class II medical device. © 2015 Patterson Dental Supply, Inc. All rights reserved. Imaging 11.8

Upload: truongtuyen

Post on 25-Apr-2018

225 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Generate movies

2D Facial Photo Wrap

Cross Sections Map

Cross Sections Projection Guide

Cross Sections Slice

Perform progress superimpositions in 3D

© 2015 Patterson Dental Supply, Inc. All rights reserved. 800.548.7241 +1.818.435.1368 [email protected] www.dolphinimaging.com

Movie Scripts

Automatically create animated movies by collecting “key frames” from your 3D volume or slice views. By altering the volume’s position, zoom factor, translucency, segmentation, clipping and timing attributes, create a movie script which may be reused for volumes of other patients.

Dolphin 3D then creates a smooth animated movie from your script. Spin, fly-by and see-through your volumetric object. Distribute movie files, add them to your Microsoft PowerPoint presentation, or play them on your iPod or other portable media player. You control the movie’s speed, resolution, quality and file size with selectable video settings.

You can also export the script’s key frames as individual images. Create a composite set of image layouts of your 3D volume for later viewing or for transfer to referring clinicians.

Reports

Create diagnostic reports from your volumetric dataset. You build a workup report specific to a patient’s indication and the specialty of the referral. Build your own library of templates for implant sites, TMJ, impaction studies, tissue pathology, sinus and airway evaluation, and more; a library of existing templates is provided. The template is easily populated on the fly with desired images and cross sections from the volume. Reports can be exported to a document file or hardcopy printout.

2D Facial Photo Wrap

Easily create a texture map on the facial surface of any CBCT, CT or MRI scan. Simply import the 2D frontal photo, and Dolphin 3D guides you through a quick and simple step-by-step process to add the photo to the 3D volume. No additional devices or add-ons are needed to create this wonderful visual identity for any patient’s 3D volume.

Dual Volume Superimposition

Superimpose volume scans from different time points to visually track and accurately measure treatment changes in bones and in airways.

View groups of cross section slices

View group of TMJ slices

Easily locate and mark nerve

Overview resulting TMJ

Isolate desired TMJ area

Select TMJ slicing position and parameters

View marked nerve under 3D

Overview of resulting cross section

Select cross section position and parameters

Isolate desired cross section area

Frontal cross section view

Hounsfield Unit colorization

3D Nerve Marking

• Patent-pending interactive tool tolocate and isolate the nerve canal on a panoramic projection

• Clearlydrawthevisiblenervecanalswithyour choice of width and color

• View/editcorrespondingnervepositionson cross sections

• View themarkednervecanalwithin3Drendering of the skull volume

TMJ View

• Chooseanareaof interest; set centerpoint andaxisdirection,designed specifically for analyzing the temporomandibular joint

• Choose desired slice thickness, width, number and direction(coronal, sagittal, or patent-pending circular)

• Viewkeycrosssectionsofthechosenaxes

Cross Section View

• Chooseapath

• Choosedesiredslicethickness,width,number,and direction (linear or patent-pending circular)

• Viewkeycrosssectionsalongthechosenpath

• Examinegroupsofslices

(06/15)

Dolphin Imaging software is designed for use by specialized dental practices for capturing, storing and presenting patient images and assisting in treatment planning and case diagnosis. Results produced by the software’s diagnostic and treatment planning tools are dependent on the interpretation of trained and licensed practitioners.

System requirements:

Windows Vista, 7, 8, 8.1, 2003 Server, 2008 Server, or2012Server.Standalone or server installs requireWindows7SP1,Server2008R2orabove.Foralloperatingsystems,Dolphin supports both 32- and 64-bit versions, and supports Business, Pro, Enterprise, and Ultimate editions. Dolphin recommendsWindows7,8,or8.1.TheDolphin3Dsystemrequires4GBofRAM,andworksbestwith8GB.Thefastestand highest quality rendering modes of Dolphin 3D require a 512MBormorevideocard,basedononeoftheseDirectXgraphicsenginesorbetter:NVIDIA87400GS,ATIHD5450orIntelHD4600.Seewww.dolphinimaging.comforadditionalrequirements.

NOTE: Dolphin 3D is not supported under terminal services.

Verified compatibility list (asofJune2015): CT (DICOM 3 multi-file or single file)

— Alphabetically listed —

• ActeonGroup-WhiteFoxscanner• Asahi/BelmontAlphardseries• CarestreamHealthKodak9000• GE3Dmedicaldevices• GendexDentalGXCB-500™

• HitachiMercuRay• ImagingSciencesInternational(ISI)i-CAT• Instrumentarium/PaloDExGroup/SOREDEXdental

imaging lines• IMTECImagingILUMA• J.Morita3DAccuitomo80andVeraviewepocs® 3D• MyRaySkyView• NewTom3G,VGand9000• PlanmecaProMax3D,ProMax3DMax• PreXion3D• SironaGALILEOSComfort,GALILEOSComfortPlus

• VatechTechnologyPicassoTrioseries• Anyothersystemthatiscapableofgeneratinga

DICOM compliant data set.

3D Facial Camera (Wavefront .OBJ format) • 3d-Shape• 3dMD• CanfieldScientificVectra3D• Di3D

Hounsfield Unit Color Mapping

New in Dolphin 3D is the Hounsfield Unit Color Mapping tool, whichhelps you distinguish between different biological structures according to their radiolucency measurements. A graph displays the colors as theyfallontheHounsfieldScaleasareference,whiletheimageonthescreen is colored in accordingly.

Dolphin 3D

The Dolphin 3D software module is a powerful tool that makes processing 3D data

extremely simple, enabling dental specialists from a wide variety of disciplines to

diagnose, plan treatment, document and present cases. Dolphin 3D allows visualization

and analysis of craniofacial anatomy from data produced by cone beam computed

tomography (CBCT), MRI, medical CT and 3D facial camera systems.

Dolphin Imaging software is an FDA-cleared Class II medical device.

© 2015 Patterson Dental Supply, Inc. All rights reserved.

Imaging 11.8

All trademarks are the property of their respective owners.

Page 2: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Dolphin Imaging 11.8 product features

Points can be digitized on the volume or on any of the slice views

Panoramic x-ray image created by Dolphin 3D from CBCT image

Frontal x-ray generated by Dolphin 3D

SMV x-ray generated by Dolphin 3D

Lateral x-ray generated by Dolphin 3D

Generated ceph brought into Dolphin’s 2D Ceph Tracing module

Collimate to the exact areas you require

Orientation setup screen

4-views (3D volume and the cross section planes in equal sized windows)

Translucent soft tissue view Translucent hard tissue view

Isolate desired region of interest

Translucent soft- and hard-tissue images of pre- and post-surgery case

View impacted teeth from any angle

Merge CBCT volume with surface data from 3D facial camera

Pre surgery

Post surgery

Slice display of airway volume and most constricted area

Simple Graphical User Interface (GUI)

Dolphin 3D includes powerful yet intuitive tools for you to process multi-dimensional datasets. There are no complicated commands or scripting languages to learn. Processing and analyzing three-dimensional data has never been easier.

Digial Study Model

3D Digital Study Model software works with all intraoral and study model scanners that export to .STL and .OBJ file format, and also seamlesslyintegrates with CEREC Omnicam and CEREC Ortho Software from Sirona. Once your study model data is imported, you can:• Setocclusionandorientation• Displaythemodelsinvarioussurfaceandvolumeviews• Takevarious3Dmeasurements• Runtraditional2Darch-length-discrepancyanalyses• Availableasastandalonemodule

Whether you scan your models or take digital impressions, you can use the new 3D Study Models software module to store these records within the patient’s chart. A patient CBCT is not required to store 3D model data.

Features

• Importfromavarietyof3Ddatasetformats

• High-quality,fast3Drendering

• Three-dimensionalairwayanalysis

• CrosssectionsinMultiplePlanarView(MPV)

• Precisevolumeorientation

• Volumestitching:combinetwoseparatevolumesintoone

• 2Dfacialphotowrapontovolume

• Volume-to-volumesuperimposition

• 3Dnervemarking

• TMJanalysis

• Generatecephalometricandpanoramicradiographs

• 3D-2Dmeasurements:distance,angleandarea

• Createanimatedmovieswithautomatedscripts

• Designimagelayoutsandreports

• Imagesexporttootherapplications

• ImageseasilysavedintoDolphinpatientdatabase

• FullyembeddedinDolphinImaging’sSQLdatabase

• 3Dimplanttreatmentplanningandsimulation

• DistinguishbiologicalstructuresviatheirradiolucencywithaHounsfieldUnitmeasuringtool

• RenderanydesiredcombinationofCBCTvolume,2D-wrappedor3D photo, airway and other surfaces, and digital teeth

• DigitalStudyModelsoftwaresupportsall.STLand.OBJfileformatsplus seamless integration with CEREC Ortho Software

olphin 3D software is already widely used by research/teaching institutes and private practicesworldwide. It features tools for onscreen manipulation

and analysis of volumetric datasets: Images are easily oriented and rotated, and tissue density thresholds can be adjusted for detailed views of craniofacial anatomy. Measurements and digitization can be performed in both 3D and traditional 2D.

Instant Ceph/Pan

Create two-dimensional radiographic images from 3D volume dataset in the lateral,panoramic (OPG), frontalandSMVviews.Reconstruct radiographs in:• 1:1projection(nodistortion,nomagnification)• Simple orthogonal/magnification projection (input % of

magnification desired)• Complex “traditional x-ray perspective” projection (input

detailed x-ray machine geometry; most accurately simulates traditional x-ray)

Image filters help emphasize different structures of interest; including: MIP (maximum intensity projection), Ray-sum (academic standard) and a collection of Dolphin proprietary filters.

Radiographic images can be saved in the Dolphin Imaging database for report generation and two-dimensional cephalometric tracing (Dolphin Ceph Tracing software required for 2D tracing).

Digitizing/Measuring

Dolphin 3D makes harvesting data from 3D volume simple, and is an excellent tool for research and data collection.

You can measure distances and angles in 3D; design your own analysis in 3D or in 2D (Dolphin Ceph Tracing software required for 2D analysis).

Analyze the airway by drawing a border around your selected portion of the volumetric scan; the program will automatically fill in and display all the airway space within that border, then report back telling you the volume of airway space in cubic millimeters. It will also locate, display and measure, in square millimeters, the most constricted spot of that airway.

Landmarkscanbeused ina3Danalysisor translated into identified2D lateralorfrontalcephalometricanalyses,suchasRoth-Jarabak,McNamara,etc.Further,the2D points can include x-ray magnification to be compatible with existing norm values.

Digitized landmarks can be saved in Dolphin Imaging and exported to a Microsoft Excel spreadsheet or other numerical analysis programs.

Easy Data Segmentation and Visualization

You prepare the 3D object by grouping intensity levels in pre-set ranges for soft tissue and hard tissue. After this simple procedure, you can easily review the object’s solid or translucent skeletal surface; solid, translucent, or photo ofsoft tissuesurface;orbothsimultaneously.Viewscanbe combined, such as translucent skeletal structures with translucent soft tissue 3D photo facial texture map.

Dolphin gives you the power to freely visualize the volume in 3D. In addition to switching from hard tissue and soft tissue views, you can also adjust the factor of translucency and intensity to reveal the structure you desire. Color tools help to further clarify anatomy and their spacial relationships.

Clipping tools allow you to quickly visualize hidden structures, or simply eliminate portions of the contents that are not relevant.

Enhanced Object Orientation

Establishing a default orientation is crucial to maximize the consistency of analysis of a 3D volume. Dolphin 3D provides tools for defining the mid-sagittal, axial and coronal planes. You can orient the volume based on anangle,suchastheFrankfortplane.Youcanalsoadjust theobject’sdefault yaw, pitch and roll. These operations can be performed on the CT soft tissue surface, CT hard tissue surface or 3D photo surface.

After a scan has been oriented, take advantage of the pre-set views: front, back, right, left, top, bottom, oblique and isometric views.

Multiple Planar Views and Layouts

Choose a layout that is best suited to your task:• 3Dvolume(justthe3Dvolumeview)• Volume+3planes(3Dvolumeand3crosssectionplanesontheside)• 4-views (3D volume and the cross section planes in equal sized

windows)

• Individualorthogonalprojectedslices:sagittal,coronalandaxialplanes• 4-volumelayout(displaysfourviewsofthesamevolume)

YoucanalsoadjustWindowLevel (traverse through12-bit,14-bitor16-bitlevels of intensity), zoom, pan, rotate, etc.

3D Implant Planning

Easily add implants to a patient’s 3D image for more precise treatment planning and presentation. Place, move, and rotate implants on the volume, slice or panoramic views. Select implant types from a generic implant template library and specify the size. Zoom in and out on an implant; define a “safety zone” around each; segment and sculpt the volume to clip around the implant; measure distances and angles; locate nerve canals; export the final simulation as an iso-surface.• Comprehensive library of implants from the industry manufacturers.• Prosthetic teeth

Page 3: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Dolphin Imaging 11.8 product features

Points can be digitized on the volume or on any of the slice views

Panoramic x-ray image created by Dolphin 3D from CBCT image

Frontal x-ray generated by Dolphin 3D

SMV x-ray generated by Dolphin 3D

Lateral x-ray generated by Dolphin 3D

Generated ceph brought into Dolphin’s 2D Ceph Tracing module

Collimate to the exact areas you require

Orientation setup screen

4-views (3D volume and the cross section planes in equal sized windows)

Translucent soft tissue view Translucent hard tissue view

Isolate desired region of interest

Translucent soft- and hard-tissue images of pre- and post-surgery case

View impacted teeth from any angle

Merge CBCT volume with surface data from 3D facial camera

Pre surgery

Post surgery

Slice display of airway volume and most constricted area

Simple Graphical User Interface (GUI)

Dolphin 3D includes powerful yet intuitive tools for you to process multi-dimensional datasets. There are no complicated commands or scripting languages to learn. Processing and analyzing three-dimensional data has never been easier.

Digial Study Model

3D Digital Study Model software works with all intraoral and study model scanners that export to .STL and .OBJ file format, and also seamlesslyintegrates with CEREC Omnicam and CEREC Ortho Software from Sirona. Once your study model data is imported, you can:• Setocclusionandorientation• Displaythemodelsinvarioussurfaceandvolumeviews• Takevarious3Dmeasurements• Runtraditional2Darch-length-discrepancyanalyses• Availableasastandalonemodule

Whether you scan your models or take digital impressions, you can use the new 3D Study Models software module to store these records within the patient’s chart. A patient CBCT is not required to store 3D model data.

Features

• Importfromavarietyof3Ddatasetformats

• High-quality,fast3Drendering

• Three-dimensionalairwayanalysis

• CrosssectionsinMultiplePlanarView(MPV)

• Precisevolumeorientation

• Volumestitching:combinetwoseparatevolumesintoone

• 2Dfacialphotowrapontovolume

• Volume-to-volumesuperimposition

• 3Dnervemarking

• TMJanalysis

• Generatecephalometricandpanoramicradiographs

• 3D-2Dmeasurements:distance,angleandarea

• Createanimatedmovieswithautomatedscripts

• Designimagelayoutsandreports

• Imagesexporttootherapplications

• ImageseasilysavedintoDolphinpatientdatabase

• FullyembeddedinDolphinImaging’sSQLdatabase

• 3Dimplanttreatmentplanningandsimulation

• DistinguishbiologicalstructuresviatheirradiolucencywithaHounsfieldUnitmeasuringtool

• RenderanydesiredcombinationofCBCTvolume,2D-wrappedor3D photo, airway and other surfaces, and digital teeth

• DigitalStudyModelsoftwaresupportsall.STLand.OBJfileformatsplus seamless integration with CEREC Ortho Software

olphin 3D software is already widely used by research/teaching institutes and private practicesworldwide. It features tools for onscreen manipulation

and analysis of volumetric datasets: Images are easily oriented and rotated, and tissue density thresholds can be adjusted for detailed views of craniofacial anatomy. Measurements and digitization can be performed in both 3D and traditional 2D.

Instant Ceph/Pan

Create two-dimensional radiographic images from 3D volume dataset in the lateral,panoramic (OPG), frontalandSMVviews.Reconstruct radiographs in:• 1:1projection(nodistortion,nomagnification)• Simple orthogonal/magnification projection (input % of

magnification desired)• Complex “traditional x-ray perspective” projection (input

detailed x-ray machine geometry; most accurately simulates traditional x-ray)

Image filters help emphasize different structures of interest; including: MIP (maximum intensity projection), Ray-sum (academic standard) and a collection of Dolphin proprietary filters.

Radiographic images can be saved in the Dolphin Imaging database for report generation and two-dimensional cephalometric tracing (Dolphin Ceph Tracing software required for 2D tracing).

Digitizing/Measuring

Dolphin 3D makes harvesting data from 3D volume simple, and is an excellent tool for research and data collection.

You can measure distances and angles in 3D; design your own analysis in 3D or in 2D (Dolphin Ceph Tracing software required for 2D analysis).

Analyze the airway by drawing a border around your selected portion of the volumetric scan; the program will automatically fill in and display all the airway space within that border, then report back telling you the volume of airway space in cubic millimeters. It will also locate, display and measure, in square millimeters, the most constricted spot of that airway.

Landmarkscanbeused ina3Danalysisor translated into identified2D lateralorfrontalcephalometricanalyses,suchasRoth-Jarabak,McNamara,etc.Further,the2D points can include x-ray magnification to be compatible with existing norm values.

Digitized landmarks can be saved in Dolphin Imaging and exported to a Microsoft Excel spreadsheet or other numerical analysis programs.

Easy Data Segmentation and Visualization

You prepare the 3D object by grouping intensity levels in pre-set ranges for soft tissue and hard tissue. After this simple procedure, you can easily review the object’s solid or translucent skeletal surface; solid, translucent, or photo ofsoft tissuesurface;orbothsimultaneously.Viewscanbe combined, such as translucent skeletal structures with translucent soft tissue 3D photo facial texture map.

Dolphin gives you the power to freely visualize the volume in 3D. In addition to switching from hard tissue and soft tissue views, you can also adjust the factor of translucency and intensity to reveal the structure you desire. Color tools help to further clarify anatomy and their spacial relationships.

Clipping tools allow you to quickly visualize hidden structures, or simply eliminate portions of the contents that are not relevant.

Enhanced Object Orientation

Establishing a default orientation is crucial to maximize the consistency of analysis of a 3D volume. Dolphin 3D provides tools for defining the mid-sagittal, axial and coronal planes. You can orient the volume based on anangle,suchastheFrankfortplane.Youcanalsoadjust theobject’sdefault yaw, pitch and roll. These operations can be performed on the CT soft tissue surface, CT hard tissue surface or 3D photo surface.

After a scan has been oriented, take advantage of the pre-set views: front, back, right, left, top, bottom, oblique and isometric views.

Multiple Planar Views and Layouts

Choose a layout that is best suited to your task:• 3Dvolume(justthe3Dvolumeview)• Volume+3planes(3Dvolumeand3crosssectionplanesontheside)• 4-views (3D volume and the cross section planes in equal sized

windows)

• Individualorthogonalprojectedslices:sagittal,coronalandaxialplanes• 4-volumelayout(displaysfourviewsofthesamevolume)

YoucanalsoadjustWindowLevel (traverse through12-bit,14-bitor16-bitlevels of intensity), zoom, pan, rotate, etc.

3D Implant Planning

Easily add implants to a patient’s 3D image for more precise treatment planning and presentation. Place, move, and rotate implants on the volume, slice or panoramic views. Select implant types from a generic implant template library and specify the size. Zoom in and out on an implant; define a “safety zone” around each; segment and sculpt the volume to clip around the implant; measure distances and angles; locate nerve canals; export the final simulation as an iso-surface.• Comprehensive library of implants from the industry manufacturers.• Prosthetic teeth

Page 4: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Dolphin Imaging 11.8 product features

Points can be digitized on the volume or on any of the slice views

Panoramic x-ray image created by Dolphin 3D from CBCT image

Frontal x-ray generated by Dolphin 3D

SMV x-ray generated by Dolphin 3D

Lateral x-ray generated by Dolphin 3D

Generated ceph brought into Dolphin’s 2D Ceph Tracing module

Collimate to the exact areas you require

Orientation setup screen

4-views (3D volume and the cross section planes in equal sized windows)

Translucent soft tissue view Translucent hard tissue view

Isolate desired region of interest

Translucent soft- and hard-tissue images of pre- and post-surgery case

View impacted teeth from any angle

Merge CBCT volume with surface data from 3D facial camera

Pre surgery

Post surgery

Slice display of airway volume and most constricted area

Simple Graphical User Interface (GUI)

Dolphin 3D includes powerful yet intuitive tools for you to process multi-dimensional datasets. There are no complicated commands or scripting languages to learn. Processing and analyzing three-dimensional data has never been easier.

Digial Study Model

3D Digital Study Model software works with all intraoral and study model scanners that export to .STL and .OBJ file format, and also seamlesslyintegrates with CEREC Omnicam and CEREC Ortho Software from Sirona. Once your study model data is imported, you can:• Setocclusionandorientation• Displaythemodelsinvarioussurfaceandvolumeviews• Takevarious3Dmeasurements• Runtraditional2Darch-length-discrepancyanalyses• Availableasastandalonemodule

Whether you scan your models or take digital impressions, you can use the new 3D Study Models software module to store these records within the patient’s chart. A patient CBCT is not required to store 3D model data.

Features

• Importfromavarietyof3Ddatasetformats

• High-quality,fast3Drendering

• Three-dimensionalairwayanalysis

• CrosssectionsinMultiplePlanarView(MPV)

• Precisevolumeorientation

• Volumestitching:combinetwoseparatevolumesintoone

• 2Dfacialphotowrapontovolume

• Volume-to-volumesuperimposition

• 3Dnervemarking

• TMJanalysis

• Generatecephalometricandpanoramicradiographs

• 3D-2Dmeasurements:distance,angleandarea

• Createanimatedmovieswithautomatedscripts

• Designimagelayoutsandreports

• Imagesexporttootherapplications

• ImageseasilysavedintoDolphinpatientdatabase

• FullyembeddedinDolphinImaging’sSQLdatabase

• 3Dimplanttreatmentplanningandsimulation

• DistinguishbiologicalstructuresviatheirradiolucencywithaHounsfieldUnitmeasuringtool

• RenderanydesiredcombinationofCBCTvolume,2D-wrappedor3D photo, airway and other surfaces, and digital teeth

• DigitalStudyModelsoftwaresupportsall.STLand.OBJfileformatsplus seamless integration with CEREC Ortho Software

olphin 3D software is already widely used by research/teaching institutes and private practicesworldwide. It features tools for onscreen manipulation

and analysis of volumetric datasets: Images are easily oriented and rotated, and tissue density thresholds can be adjusted for detailed views of craniofacial anatomy. Measurements and digitization can be performed in both 3D and traditional 2D.

Instant Ceph/Pan

Create two-dimensional radiographic images from 3D volume dataset in the lateral,panoramic (OPG), frontalandSMVviews.Reconstruct radiographs in:• 1:1projection(nodistortion,nomagnification)• Simple orthogonal/magnification projection (input % of

magnification desired)• Complex “traditional x-ray perspective” projection (input

detailed x-ray machine geometry; most accurately simulates traditional x-ray)

Image filters help emphasize different structures of interest; including: MIP (maximum intensity projection), Ray-sum (academic standard) and a collection of Dolphin proprietary filters.

Radiographic images can be saved in the Dolphin Imaging database for report generation and two-dimensional cephalometric tracing (Dolphin Ceph Tracing software required for 2D tracing).

Digitizing/Measuring

Dolphin 3D makes harvesting data from 3D volume simple, and is an excellent tool for research and data collection.

You can measure distances and angles in 3D; design your own analysis in 3D or in 2D (Dolphin Ceph Tracing software required for 2D analysis).

Analyze the airway by drawing a border around your selected portion of the volumetric scan; the program will automatically fill in and display all the airway space within that border, then report back telling you the volume of airway space in cubic millimeters. It will also locate, display and measure, in square millimeters, the most constricted spot of that airway.

Landmarkscanbeused ina3Danalysisor translated into identified2D lateralorfrontalcephalometricanalyses,suchasRoth-Jarabak,McNamara,etc.Further,the2D points can include x-ray magnification to be compatible with existing norm values.

Digitized landmarks can be saved in Dolphin Imaging and exported to a Microsoft Excel spreadsheet or other numerical analysis programs.

Easy Data Segmentation and Visualization

You prepare the 3D object by grouping intensity levels in pre-set ranges for soft tissue and hard tissue. After this simple procedure, you can easily review the object’s solid or translucent skeletal surface; solid, translucent, or photo ofsoft tissuesurface;orbothsimultaneously.Viewscanbe combined, such as translucent skeletal structures with translucent soft tissue 3D photo facial texture map.

Dolphin gives you the power to freely visualize the volume in 3D. In addition to switching from hard tissue and soft tissue views, you can also adjust the factor of translucency and intensity to reveal the structure you desire. Color tools help to further clarify anatomy and their spacial relationships.

Clipping tools allow you to quickly visualize hidden structures, or simply eliminate portions of the contents that are not relevant.

Enhanced Object Orientation

Establishing a default orientation is crucial to maximize the consistency of analysis of a 3D volume. Dolphin 3D provides tools for defining the mid-sagittal, axial and coronal planes. You can orient the volume based on anangle,suchastheFrankfortplane.Youcanalsoadjust theobject’sdefault yaw, pitch and roll. These operations can be performed on the CT soft tissue surface, CT hard tissue surface or 3D photo surface.

After a scan has been oriented, take advantage of the pre-set views: front, back, right, left, top, bottom, oblique and isometric views.

Multiple Planar Views and Layouts

Choose a layout that is best suited to your task:• 3Dvolume(justthe3Dvolumeview)• Volume+3planes(3Dvolumeand3crosssectionplanesontheside)• 4-views (3D volume and the cross section planes in equal sized

windows)

• Individualorthogonalprojectedslices:sagittal,coronalandaxialplanes• 4-volumelayout(displaysfourviewsofthesamevolume)

YoucanalsoadjustWindowLevel (traverse through12-bit,14-bitor16-bitlevels of intensity), zoom, pan, rotate, etc.

3D Implant Planning

Easily add implants to a patient’s 3D image for more precise treatment planning and presentation. Place, move, and rotate implants on the volume, slice or panoramic views. Select implant types from a generic implant template library and specify the size. Zoom in and out on an implant; define a “safety zone” around each; segment and sculpt the volume to clip around the implant; measure distances and angles; locate nerve canals; export the final simulation as an iso-surface.• Comprehensive library of implants from the industry manufacturers.• Prosthetic teeth

Page 5: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Generate movies

2D Facial Photo Wrap

Cross Sections Map

Cross Sections Projection Guide

Cross Sections Slice

Perform progress superimpositions in 3D

© 2015 Patterson Dental Supply, Inc. All rights reserved. 800.548.7241 +1.818.435.1368 [email protected] www.dolphinimaging.com

Movie Scripts

Automatically create animated movies by collecting “key frames” from your 3D volume or slice views. By altering the volume’s position, zoom factor, translucency, segmentation, clipping and timing attributes, create a movie script which may be reused for volumes of other patients.

Dolphin 3D then creates a smooth animated movie from your script. Spin, fly-by and see-through your volumetric object. Distribute movie files, add them to your Microsoft PowerPoint presentation, or play them on your iPod or other portable media player. You control the movie’s speed, resolution, quality and file size with selectable video settings.

You can also export the script’s key frames as individual images. Create a composite set of image layouts of your 3D volume for later viewing or for transfer to referring clinicians.

Reports

Create diagnostic reports from your volumetric dataset. You build a workup report specific to a patient’s indication and the specialty of the referral. Build your own library of templates for implant sites, TMJ, impaction studies, tissue pathology, sinus and airway evaluation, and more; a library of existing templates is provided. The template is easily populated on the fly with desired images and cross sections from the volume. Reports can be exported to a document file or hardcopy printout.

2D Facial Photo Wrap

Easily create a texture map on the facial surface of any CBCT, CT or MRI scan. Simply import the 2D frontal photo, and Dolphin 3D guides you through a quick and simple step-by-step process to add the photo to the 3D volume. No additional devices or add-ons are needed to create this wonderful visual identity for any patient’s 3D volume.

Dual Volume Superimposition

Superimpose volume scans from different time points to visually track and accurately measure treatment changes in bones and in airways.

View groups of cross section slices

View group of TMJ slices

Easily locate and mark nerve

Overview resulting TMJ

Isolate desired TMJ area

Select TMJ slicing position and parameters

View marked nerve under 3D

Overview of resulting cross section

Select cross section position and parameters

Isolate desired cross section area

Frontal cross section view

Hounsfield Unit colorization

3D Nerve Marking

• Patent-pending interactive tool tolocate and isolate the nerve canal on a panoramic projection

• Clearlydrawthevisiblenervecanalswithyour choice of width and color

• View/editcorrespondingnervepositionson cross sections

• View themarkednervecanalwithin3Drendering of the skull volume

TMJ View

• Chooseanareaof interest; set centerpoint andaxisdirection,designed specifically for analyzing the temporomandibular joint

• Choose desired slice thickness, width, number and direction(coronal, sagittal, or patent-pending circular)

• Viewkeycrosssectionsofthechosenaxes

Cross Section View

• Chooseapath

• Choosedesiredslicethickness,width,number,and direction (linear or patent-pending circular)

• Viewkeycrosssectionsalongthechosenpath

• Examinegroupsofslices

(06/15)

Dolphin Imaging software is designed for use by specialized dental practices for capturing, storing and presenting patient images and assisting in treatment planning and case diagnosis. Results produced by the software’s diagnostic and treatment planning tools are dependent on the interpretation of trained and licensed practitioners.

System requirements:

Windows Vista, 7, 8, 8.1, 2003 Server, 2008 Server, or2012Server.Standalone or server installs requireWindows7SP1,Server2008R2orabove.Foralloperatingsystems,Dolphin supports both 32- and 64-bit versions, and supports Business, Pro, Enterprise, and Ultimate editions. Dolphin recommendsWindows7,8,or8.1.TheDolphin3Dsystemrequires4GBofRAM,andworksbestwith8GB.Thefastestand highest quality rendering modes of Dolphin 3D require a 512MBormorevideocard,basedononeoftheseDirectXgraphicsenginesorbetter:NVIDIA87400GS,ATIHD5450orIntelHD4600.Seewww.dolphinimaging.comforadditionalrequirements.

NOTE: Dolphin 3D is not supported under terminal services.

Verified compatibility list (asofJune2015): CT (DICOM 3 multi-file or single file)

— Alphabetically listed —

• ActeonGroup-WhiteFoxscanner• Asahi/BelmontAlphardseries• CarestreamHealthKodak9000• GE3Dmedicaldevices• GendexDentalGXCB-500™

• HitachiMercuRay• ImagingSciencesInternational(ISI)i-CAT• Instrumentarium/PaloDExGroup/SOREDEXdental

imaging lines• IMTECImagingILUMA• J.Morita3DAccuitomo80andVeraviewepocs® 3D• MyRaySkyView• NewTom3G,VGand9000• PlanmecaProMax3D,ProMax3DMax• PreXion3D• SironaGALILEOSComfort,GALILEOSComfortPlus

• VatechTechnologyPicassoTrioseries• Anyothersystemthatiscapableofgeneratinga

DICOM compliant data set.

3D Facial Camera (Wavefront .OBJ format) • 3d-Shape• 3dMD• CanfieldScientificVectra3D• Di3D

Hounsfield Unit Color Mapping

New in Dolphin 3D is the Hounsfield Unit Color Mapping tool, whichhelps you distinguish between different biological structures according to their radiolucency measurements. A graph displays the colors as theyfallontheHounsfieldScaleasareference,whiletheimageonthescreen is colored in accordingly.

Dolphin 3D

The Dolphin 3D software module is a powerful tool that makes processing 3D data

extremely simple, enabling dental specialists from a wide variety of disciplines to

diagnose, plan treatment, document and present cases. Dolphin 3D allows visualization

and analysis of craniofacial anatomy from data produced by cone beam computed

tomography (CBCT), MRI, medical CT and 3D facial camera systems.

Dolphin Imaging software is an FDA-cleared Class II medical device.

© 2015 Patterson Dental Supply, Inc. All rights reserved.

Imaging 11.8

All trademarks are the property of their respective owners.

Page 6: 3D Nerve Marking Imaging 11 - Dolphin Imag resolution, ... Imaging 11.8 All trademarks are ... Lateral x-ray generated by Dolphin 3D Generated ceph brought into Dolphin’s 2D Ceph

Generate movies

2D Facial Photo Wrap

Cross Sections Map

Cross Sections Projection Guide

Cross Sections Slice

Perform progress superimpositions in 3D

© 2015 Patterson Dental Supply, Inc. All rights reserved. 800.548.7241 +1.818.435.1368 [email protected] www.dolphinimaging.com

Movie Scripts

Automatically create animated movies by collecting “key frames” from your 3D volume or slice views. By altering the volume’s position, zoom factor, translucency, segmentation, clipping and timing attributes, create a movie script which may be reused for volumes of other patients.

Dolphin 3D then creates a smooth animated movie from your script. Spin, fly-by and see-through your volumetric object. Distribute movie files, add them to your Microsoft PowerPoint presentation, or play them on your iPod or other portable media player. You control the movie’s speed, resolution, quality and file size with selectable video settings.

You can also export the script’s key frames as individual images. Create a composite set of image layouts of your 3D volume for later viewing or for transfer to referring clinicians.

Reports

Create diagnostic reports from your volumetric dataset. You build a workup report specific to a patient’s indication and the specialty of the referral. Build your own library of templates for implant sites, TMJ, impaction studies, tissue pathology, sinus and airway evaluation, and more; a library of existing templates is provided. The template is easily populated on the fly with desired images and cross sections from the volume. Reports can be exported to a document file or hardcopy printout.

2D Facial Photo Wrap

Easily create a texture map on the facial surface of any CBCT, CT or MRI scan. Simply import the 2D frontal photo, and Dolphin 3D guides you through a quick and simple step-by-step process to add the photo to the 3D volume. No additional devices or add-ons are needed to create this wonderful visual identity for any patient’s 3D volume.

Dual Volume Superimposition

Superimpose volume scans from different time points to visually track and accurately measure treatment changes in bones and in airways.

View groups of cross section slices

View group of TMJ slices

Easily locate and mark nerve

Overview resulting TMJ

Isolate desired TMJ area

Select TMJ slicing position and parameters

View marked nerve under 3D

Overview of resulting cross section

Select cross section position and parameters

Isolate desired cross section area

Frontal cross section view

Hounsfield Unit colorization

3D Nerve Marking

• Patent-pending interactive tool tolocate and isolate the nerve canal on a panoramic projection

• Clearlydrawthevisiblenervecanalswithyour choice of width and color

• View/editcorrespondingnervepositionson cross sections

• View themarkednervecanalwithin3Drendering of the skull volume

TMJ View

• Chooseanareaof interest; set centerpoint andaxisdirection,designed specifically for analyzing the temporomandibular joint

• Choose desired slice thickness, width, number and direction(coronal, sagittal, or patent-pending circular)

• Viewkeycrosssectionsofthechosenaxes

Cross Section View

• Chooseapath

• Choosedesiredslicethickness,width,number,and direction (linear or patent-pending circular)

• Viewkeycrosssectionsalongthechosenpath

• Examinegroupsofslices

(06/15)

Dolphin Imaging software is designed for use by specialized dental practices for capturing, storing and presenting patient images and assisting in treatment planning and case diagnosis. Results produced by the software’s diagnostic and treatment planning tools are dependent on the interpretation of trained and licensed practitioners.

System requirements:

Windows Vista, 7, 8, 8.1, 2003 Server, 2008 Server, or2012Server.Standalone or server installs requireWindows7SP1,Server2008R2orabove.Foralloperatingsystems,Dolphin supports both 32- and 64-bit versions, and supports Business, Pro, Enterprise, and Ultimate editions. Dolphin recommendsWindows7,8,or8.1.TheDolphin3Dsystemrequires4GBofRAM,andworksbestwith8GB.Thefastestand highest quality rendering modes of Dolphin 3D require a 512MBormorevideocard,basedononeoftheseDirectXgraphicsenginesorbetter:NVIDIA87400GS,ATIHD5450orIntelHD4600.Seewww.dolphinimaging.comforadditionalrequirements.

NOTE: Dolphin 3D is not supported under terminal services.

Verified compatibility list (asofJune2015): CT (DICOM 3 multi-file or single file)

— Alphabetically listed —

• ActeonGroup-WhiteFoxscanner• Asahi/BelmontAlphardseries• CarestreamHealthKodak9000• GE3Dmedicaldevices• GendexDentalGXCB-500™

• HitachiMercuRay• ImagingSciencesInternational(ISI)i-CAT• Instrumentarium/PaloDExGroup/SOREDEXdental

imaging lines• IMTECImagingILUMA• J.Morita3DAccuitomo80andVeraviewepocs® 3D• MyRaySkyView• NewTom3G,VGand9000• PlanmecaProMax3D,ProMax3DMax• PreXion3D• SironaGALILEOSComfort,GALILEOSComfortPlus

• VatechTechnologyPicassoTrioseries• Anyothersystemthatiscapableofgeneratinga

DICOM compliant data set.

3D Facial Camera (Wavefront .OBJ format) • 3d-Shape• 3dMD• CanfieldScientificVectra3D• Di3D

Hounsfield Unit Color Mapping

New in Dolphin 3D is the Hounsfield Unit Color Mapping tool, whichhelps you distinguish between different biological structures according to their radiolucency measurements. A graph displays the colors as theyfallontheHounsfieldScaleasareference,whiletheimageonthescreen is colored in accordingly.

Dolphin 3D

The Dolphin 3D software module is a powerful tool that makes processing 3D data

extremely simple, enabling dental specialists from a wide variety of disciplines to

diagnose, plan treatment, document and present cases. Dolphin 3D allows visualization

and analysis of craniofacial anatomy from data produced by cone beam computed

tomography (CBCT), MRI, medical CT and 3D facial camera systems.

Dolphin Imaging software is an FDA-cleared Class II medical device.

© 2015 Patterson Dental Supply, Inc. All rights reserved.

Imaging 11.8

All trademarks are the property of their respective owners.