3d ir30 slides 1-15

Upload: romero-andrade

Post on 02-Jun-2018

287 views

Category:

Documents


12 download

TRANSCRIPT

  • 8/10/2019 3d IR30 Slides 1-15

    1/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    SPM, Vibration Measurement,Datalogging with IR30

  • 8/10/2019 3d IR30 Slides 1-15

    2/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    What is an IR30?

    Hand held - predictive maintenance tool

    Shock Pulse Bearing Monitoring Device

    (IR30 Sentinel)

    Vibration Severity Meter

    (IR30 Logger)

    Condition Monitoring Instrument

    Data logger

  • 8/10/2019 3d IR30 Slides 1-15

    3/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Que es una Herramienta IR30?

    Herramienta Manual de MantenimientoPredictivo

    Dispositivo de medicion de pulsos de choqueen rodamientos

    (IR30 Sentinel) Medidor de Vibracion

    (IR30 Logger)

    Instrumento de Monitoreo Dispositivo de Almacenamiento de Datos

  • 8/10/2019 3d IR30 Slides 1-15

    4/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Logger- Vibration Measurement with

    Accelerometer

  • 8/10/2019 3d IR30 Slides 1-15

    5/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Medicion de Vibracion con

    Acelerometro

  • 8/10/2019 3d IR30 Slides 1-15

    6/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Data Logger Kit CCN 39263009

    CCN: 39263009

    Includes:

    I-R 30 Instrument

    Condmaster Pro Software Instruction Manual

    PC cables & hardware key

    Vibration probes

    Batteries Carrying case

  • 8/10/2019 3d IR30 Slides 1-15

    7/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Data Logger Kit CCN 39263009

    CCN: 39263009

    Includes:

    I-R 30 Instrument

    Condmaster Pro Software Instruction Manual

    PC cables & hardware key

    Vibration probes

    Batteries Carrying case

  • 8/10/2019 3d IR30 Slides 1-15

    8/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Logger, Sentinel & Compact

    C f

  • 8/10/2019 3d IR30 Slides 1-15

    9/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Vibration readings with accelerometer

    SPM with manual probe

    PC communication

    Preloads machine data prior to visitand produces trend analysis.

    Have route capability

    IR30 Logger - features

    Di t i C t if i t i T i i

  • 8/10/2019 3d IR30 Slides 1-15

    10/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Lectura de Vibraciones con Acelermetro

    Lectura de Pulsos de Choque en forma

    manual

    Comunicacion con PC

    Precarga de Parametros de cada Maquinasegun programa de visitas.

    Have route capability

    IR30 Logger - features

    Di t i C t if i t i T i i

  • 8/10/2019 3d IR30 Slides 1-15

    11/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30-Sentinel

    IR30 Sentinel Takes SPM readings and it

    does not have route capability.

    Readings are taken and then documented.

    Data is then transferred to either Condmaster

    Pro or Excel trending files manually.

    Sentinel may be upgraded to logger for fee.

    CCN 38332284

    Di t i C t if i t i T i i

  • 8/10/2019 3d IR30 Slides 1-15

    12/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30-Sentinel

    IR30 Sentinel toma lecturas de Pulsos .

    Lectura y almacenamiento en un documento.

    Data es transferida del Condmaster Pro a

    documento Excel manualmente.

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    13/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Compact

    IR30 Compact uses same technology as sentinelto take SPM readings

    Compact does not have Vibration capability.

    Compact can store ten readings

    Can take set of readings on one or two machines and then recorddata on inspection sheets

    Compact has Infrared temperature reading

    Compact has Electronic Stethoscope capability with

    standard set of headphones.

    Compact significantly less expensive than Sentinel.

    Compact is not intended as a replacement for

    Sentinel and logger but as another tool to

    accomplish Shock pulse monitoring and trending.

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    14/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR30 Compact

    IR30 utiliza la misma tecnologia que el sentinelpara tomar lecturas de Pulso de Choque

    Compact does not have Vibration capability.

    Compact can store ten readings

    Can take set of readings on one or two machines and then recorddata on inspection sheets

    Compact has Infrared temperature reading

    Compact has Electronic Stethoscope capability with

    standard set of headphones.

    Compact significantly less expensive than Sentinel.

    Compact is not intended as a replacement for

    Sentinel and logger but as another tool to

    accomplish Shock pulse monitoring and trending.

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    15/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Evaluation in green,

    yellow and red

    Five buttons

    SPM transducer,

    dBm/dBc

    Display with backlight

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    16/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Headphone connection

    for listening toshock pulses or

    machinery noise

    LEMO connector for

    external SPM transducers

    Blue LED

    indicating measurement

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    17/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR 30 - Two Different Types of Measurements

    (IR30 Sentinel)(IR30 Logger)

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    18/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    IR 30 - Shock Pulse Method

    Piezo-electric transducer

    approx. 30kHz natural frequency

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    19/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    SPM Shock Pulses

    Pressure waves, generated by rollingelements and the raceway.

    Measured by transducer which amplifies the

    shock signal and filters out machine

    vibration. Pattern consists of a rapid sequence of

    strong and weak pulses

    dBc decibel carpet - the large number ofrelatively weak shock pulses

    dBm ( decibel max) - few strong pulses in

    the pattern

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    20/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    Ingersoll-Rand Proprietary Information. Rev. Jan. 2010

    Normalized & Absolute readings

    dBi=initial value of a bearing

    (Function ofRotor Diameter & Rotor

    Speed). If dBi is not known, use

    25 as default to Oil Injected

    units and 35 to Oil Free units.

    dBc=Carpet value (weak pulses)

    dBm=Maximum value (strongpulses)

    dBn=Unit for normalized shock

    level

    dBsv=Unit for absolute shockleveldB=20Lg10Vin

    Vcc

    Lg100,1=-1; Lg101=0; Lg1010=1; Lg10100=2;

    Diagnos t ics Cert if icat ion Training

  • 8/10/2019 3d IR30 Slides 1-15

    21/21

    Diagnos t ics Cert if icat ion Training

    IR30

    IR Global Service Education Team

    I ll R d P i I f i R J 2010

    IR 30 - Shock Pulse Method