333 mann st_arch_issue a

24
PROJECT: CLIENT: ARCHITECT: ISSUE DATE: chapman architecture ARCHITECTURAL DRAWINGS COVER SHEET NOTES: MANN ST (NSW) Pty Ltd THESE DOCUMENTS ARE FOR COORDINATION PURPOSES ONLY. THESE DOCUMENTS DO NOT FORM PART OF A CONTRACT SET OF DOCUMENTS. ALL STRUCTURAL, HYDRAULIC, ELECTRICAL & MECHANICAL INFORMATION SHOWN IN ARCHITECTURAL DOCUMENTS IS INDICATIVE ONLY - REFER TO ENGINEER’S SEPARATE DOCUMENTATION. REPORT DISCREPANCIES WITH ARCHITECTURAL & SERVICES DOCUMENTS IMMEDIATELY TO ARCHITECT BEFORE PROCEEDING WITH WORKS. SHOP DRAWINGS TO BE COMPLETED FOR ALL STEELWORK, JOINERY & OTHER NOMINATED ITEMS PRIOR TO COMMENCEMENT OF CONSTRUCTION AND WITH ADEQUATE TIME ALLOWED FOR REVIEW BY ARCHITECT AND ENGINEER. COMPLY WITH THE BUILDING CODE of AUSTRALIA 2010, DEVELOPMENT CONSENT & APPLICABLE AUSTRALIAN STANDARDS. IKON TOWER ADDRESS 333 MANN ST GOSFORD DECEMBER 2015 DA-001 DA - 001 DA - 002 DA - 003 DA - 004 DA - 005 DA - 006 DA - 007 DA - 008 DA - 101 DA - 102 DA - 103 DA - 104 DA - 105 DA - 106 DA - 107 DA - 108 DA - 109 DA - 110 DA - 111 DA - 112 DA - 201 DA - 202 DA - 301 DA - 302 TITLE SHEET PROJECT OUTLINE BASIX COMMITMENTS SITE ANALYSIS DEMOLITION PLAN SHADOW DIAGRAMS APARTMENT COMPLIANCE DIAGRAMS VIEW ANALYSIS B5 BASEMENT PLAN B4 BASEMENT PLAN B3 BASEMENT PLAN B2 BASEMENT PLAN B1 BASEMENT PLAN LOWER GROUND PLAN GROUND FLOOR PODIUM PLAN LEVEL 1 PODIUM PLAN LEVEL 2 PLAN - APARTMENTS TYPICAL PLAN - APARTMENTS ROOFTOP PLAN ROOF PLAN SECTIONS SECTIONS ELEVATIONS ELEVATIONS chapman 0m 1m 2m 5m DRAWING TITLE: DRAWING NO.: DATE: SCALE: PROJECT: CLIENT: 17.12.2015 A ISSUE: NOT FOR CONSTRUCTION 1:100 @ A1 ISSUE DESCRIPTION DATE A architecture 17.12.2015 IKON MANN ST (NSW) Pty Ltd 162 EBLEY ST BONDI JUNCTION T: 0420 382 700 E: [email protected] ARCHITECTS: IN COLLABORATION WITH DRAFT DA SUBMISSION THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL, ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC. DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE USED. REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS DOCUMENTS FOR ALL SIZES.

Upload: ethaniel-brunson

Post on 12-Apr-2017

176 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 333 Mann St_Arch_Issue A

PROJECT:

CLIENT:

ARCHITECT:

ISSUE DATE:

chapmanarchitecture

ARCHITECTURAL DRAWINGS

COVER SHEET

NOTES:

MANN ST (NSW) Pty Ltd

THESE DOCUMENTS ARE FOR COORDINATION PURPOSES ONLY. THESE DOCUMENTS DO NOT FORM

PART OF A CONTRACT SET OF DOCUMENTS.

ALL STRUCTURAL, HYDRAULIC, ELECTRICAL & MECHANICAL INFORMATION SHOWN IN ARCHITECTURAL

DOCUMENTS IS INDICATIVE ONLY - REFER TO ENGINEER’S SEPARATE DOCUMENTATION. REPORT

DISCREPANCIES WITH ARCHITECTURAL & SERVICES DOCUMENTS IMMEDIATELY TO ARCHITECT BEFORE

PROCEEDING WITH WORKS.

SHOP DRAWINGS TO BE COMPLETED FOR ALL STEELWORK, JOINERY & OTHER NOMINATED ITEMS PRIOR

TO COMMENCEMENT OF CONSTRUCTION AND WITH ADEQUATE TIME ALLOWED FOR REVIEW BY

ARCHITECT AND ENGINEER.

COMPLY WITH THE BUILDING CODE of AUSTRALIA 2010, DEVELOPMENT CONSENT & APPLICABLE

AUSTRALIAN STANDARDS.

IKON TOWERADDRESS

333 MANN ST GOSFORD

DECEMBER 2015

DA-001

DA - 001

DA - 002

DA - 003

DA - 004

DA - 005

DA - 006

DA - 007

DA - 008

DA - 101

DA - 102

DA - 103

DA - 104

DA - 105

DA - 106

DA - 107

DA - 108

DA - 109

DA - 110

DA - 111

DA - 112

DA - 201

DA - 202

DA - 301

DA - 302

TITLE SHEET

PROJECT OUTLINE

BASIX COMMITMENTS

SITE ANALYSIS

DEMOLITION PLAN

SHADOW DIAGRAMS

APARTMENT COMPLIANCE DIAGRAMS

VIEW ANALYSIS

B5 BASEMENT PLAN

B4 BASEMENT PLAN

B3 BASEMENT PLAN

B2 BASEMENT PLAN

B1 BASEMENT PLAN

LOWER GROUND PLAN

GROUND FLOOR PODIUM PLAN

LEVEL 1 PODIUM PLAN

LEVEL 2 PLAN - APARTMENTS

TYPICAL PLAN - APARTMENTS

ROOFTOP PLAN

ROOF PLAN

SECTIONS

SECTIONS

ELEVATIONS

ELEVATIONS

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

Page 2: 333 Mann St_Arch_Issue A

PLANNING CONTROLS

PROJECT OUTLINE

DA-002

SITE LOCATION AERIAL PHOTOGRAPH 1:10001:4000 CONSULTANT TEAM

PLANNING CALCULATIONS

01 SITE DETAILS

SITE AREA 1778 m2

6.5:1

02 CAR PARKING

11558 m2

APARTMENT CALCULATIONS

RESIDENTIAL @ 1 PER UNIT 102 SPACES

COMMERCIAL/RETAIL @ 1 PER 40 m2

GFA 11558 m2

FSR (INCL. 30% BONUS)

BUILDING HEIGHT (INCL. 30% BONUS) 78 m

AREA CALCULATIONS

REFER TO SCHEDULE

REFER TO SCHEDULE

REFER TO PLANNING REPORT

REFER TO PLANNING REPORT

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

Page 3: 333 Mann St_Arch_Issue A

BASIX COMMITMENTS

BASIX COMMITMENTS

DA-003

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

Page 4: 333 Mann St_Arch_Issue A

DA - 004

SITE ANALYSIS PLAN

0m 2m 5m

N1:200 @ A1

10m

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

SUMMER SUN PATH

WINTER SUN PATH

WINTER SUN PATH

SUMMER SUN PATH

NORTH EAST BREEZE

STRONG SOUTHERLYWINDS

WATER VIEWS

DISTRICTVIEWS

DISTRICTVIEWS

DISTRICTVIEWS

TRAF

FIC N

OISE

FUTU

RE

CHAR

ACTE

R A

CTIVE STR

EET FR

ONTA

GE

FUTU

RE

CHAR

ACTE

R A

CTIVE STR

EET FR

ONTA

GE

DISTRICTVIEWS

PROMINENT CORNER

’GATE WAY’ SITE

ETNA

STREET

MA

NN

BK

TEL

BK

PP

W.M.

LID

LAWN

TEL

LAWN

CONC.

PATH

TEL

LP

LP W.M.

LID

"SUZUKI" SIGN

LP

W.M.

LID

TEL

LP

LP

PP

BK

BRIC

KR

ET

AININ

GW

ALL

BK

BK

BK

BK

BK

BK

BK

PP

TRAFFICLIGHT

TRAFFICLIGHT

ELEC

TEL

SV

SV

HYD LID

KERB

TIM

BER

DEC

K

KE

RB

W.M.

LID

GA

RD

EN

LA

WN

GRATED PITINV.20.54

GRATED PITINV.20.8

GRATED PIT

CARPORT

GRATED PITINV.22.74

MESH

FENCEBRICK PAVED CARPARK

VE

HIC

LE

CR

OS

SIN

G

GRATED PITINV.21.86

LAWN

MESH

FENCE

CONC.

PATH

CO

NC.

PA

TH

GA

RD

EN

METAL

FENCE

ON

TOP

OF

BRICK

RET.WALL

ME

TA

L

FE

NC

E

ON

TO

P

OF

BRIC

KR

ET.

WA

LL

METAL FENCE ON TOP

OF BRICK RET. WALL

PP

LID

ELECLID

SV

ON

TO

P

OF

FE

NC

E

ME

TA

L

W.M.

LID

APPROX. L

OCATION

OF UNDERGROUND

NBN CABLE

BM ONTOP OF KERBRL 24.01

1

D.P. 787759SITE AREA

TREE

5 S 4 H

TREE

6 S 6 H

TREE

6 S 6 H

C

D.P. 330139

SEC 1D.P. 1591

13

ME

TA

L

TIMBER

FENCE

METAL

FENCE

PA

LIN

G

FE

NC

E

METAL GARAGE

HEAD 27.98SILL 26.54

HEAD 28.10SILL 26.51

HEAD27.70SILL 27.10

No. 33WEATHERBOARD DWELLINGTILE ROOF

SMH

TREE

6 S 6 H

TREE

6 S 6 H

CONC. CARPARK

PATIO

CONC.

PA

NE

L

SEP

AR

ATIO

N

CONC & BITUMENCARPARK

18.2

918.45

18.47

18.6

6

18.7

8 18.9

7

19.0319

.03 19

.19

19.2

3

19.2

9TEL

TEL

ROCK

LOG

WALL

CONC

DRIVEWAY

BITUMEN CARPARK

BITUMEN

GARDEN

CARPARK

RAISED

RAISED

GARDEN

BITUMEN CARPARK BITUMEN CARPARK

BITUMEN CARPARK

19.32

19.33

19.3

3

19.33

19.38

19.40

19.4

3

19.48

19.49

19.53

19.53

19.54

19.57

19.57

19.58

19.58

19.58

19.59

19.59

19.6

3

19.6

4

19.6

8

19.79

19.81

19.84

19.8

6

19.87

19.9

1

OUTL

ET

19.9

4

19.9

5

19.9

7

20.04

20.05OUTLET

20.12

20.12

20.16

20.16

20.18

20.2

3

20.2

4

20.2

7

20.2

8

OUTL

ET

20.33

20.39

20.39

20.41

20.42

20.4

3

20.49

20.50

20.51

20.51

20.51

20.52

20.54

20.56

20.56

20.56

20.58

20.58

20.6

8

20.6

8

20.6

8

20.74

20.77

20.77

20.78

20.78

20.78

20.79

20.7920.80

20.81

20.84

20.8

4

20.84

20.85

20.85

20.9

0

20.9

2

20.9

6

20.9

6

20.9

7

20.98

21.00

21.00

21.04

21.05

21.08

21.12

21.12

21.1

4

21.14

21.16

21.18

21.2

4

21.2

4

21.2

5

21.2

7

21.2

8

21.2

9

21.30

21.33

21.37

21.38

21.46

21.46

21.54

21.54

21.55

21.5921.6

1

21.6

3

21.6

5

21.6

6

21.6

6

21.6

6

21.6

7

21.74

21.74

21.76

21.8

1

21.82

21.82

21.85

21.87

21.8

8 21.9

0

21.9

1

21.9

5

21.9

5

21.9

9

21.9

9

22.00

22.01

22.01

22.04

22.07

22.07

22.07

22.08

22.10

22.13

22.14

22.17

22.18

22.18

22.18

22.19

22.2

5

22.2

7

22.30

22.32

22.33

22.34

22.35

22.37

22.37

22.40

22.45

22.45

22.46

22.46

22.49

22.49

22.52

22.53

22.54

22.54

22.54

22.54

22.55

22.58

22.6

3

22.65

22.6

7

22.6

8FL

FL

FL

FL

GUTTER

GUTTER

GUTTER

GU

TTE

R

GU

TTE

R

CO

NC.

CO

NC.

GU

TT

ER

GU

TT

ER

RID

GE

CONC.

CONC.

GA

RD

EN

W

W

W

RID

GE

GU

TT

ER

MES

H

GA

TE F

EN

CE

MES

H

GA

TE FE

NC

E

22.69

22.70

22.72

22.73

22.73

22.74

22.76

22.79

22.81

22.84

22.85

22.88

22.9

6

22.97

22.9

7

22.9

7

22.9

7

22.9

8

22.9

9

22.9

9

23.02

23.05

23.06

23.06

23.07

23.11

23.12

23.12 23

.14

23.14

23.15

23.15

23.16

23.16

23.1

8

23.2

0

23.2

1

23.22

23.2

4

23.2

6

23.2

7

23.2

9

23.30

23.3

0

23.32

23.33

23.35

23.37

23.39

23.40

23.42

23.44

23.45

23.47

23.47

23.48

23.51

23.53

23.54

23.55

23.56

23.5

8

23.6

1

23.61

23.6

2

23.6

2

23.67

23.68

23.6

9

23.71

23.71

23.72

23.73

23.73

23.73

23.75

23.76

23.79

23.79

23.79

23.80

23.81

23.83

23.83

23.83

23.83

23.88

23.88

23.9

0

23.9

2

23.9

2

23.9

3

23.9

3

23.9

3

23.9

6

23.9

7

23.9

823.9

924.01

24.01

24.01

98°30’30"

45.28

8°2

9’1

0"

40.6

65

278°28’35" 28.325

268°25’10"

9.2

239°24’10"

4.32

210°14’2

5"

12.3

35

188°2

5’2

5"

24.8

55

24.0224.02

24.05

24.05

24.08

24.09

24.11

24.1

4

24.15

24.17

24.18

24.2

3

24.30

24.30

24.33

24.36

24.37

24.50

24.6

0

24.6

0

24.6

224.6

3

24.7

3

24.77

24.82

24.8

2

25.09

26.01

26.41

26.41

26.41

26.41

26.70

26.71

26.74

27.73

27.76

28.24

28.2

5

28.31

28.31

28.69

30.6

1

1778 m†

ST

RE

ET

VEHICLE CROSSING

MA

NN

Page 5: 333 Mann St_Arch_Issue A

ETNA STREET

BK

TEL

BK

PP

W.M.

LID LAWN

TEL

LAWN

CONC.

PATH

TEL

LP

LP

W.M.

LID

"SUZUKI" SIGN

LP

W.M.

LID

TEL

LP

LP

PP

BK

BK

BK

BK

BK

BK

BK

PPTRAFFIC

LIGHT

TRAFFICLIGHT

ELEC

TEL

SV

SV

HYD LID

KERB

TIM

BER

DEC

K

W.M.

LID

GA

RD

EN

LA

WN

GRATED PIT

INV.20.54GRATED PIT

INV.20.8

GRATED PIT

CARPORT

GRATED PIT

INV.22.74

MESH FENCE

BRICK PAVED CARPARK

VE

HIC

LE

CR

OS

SIN

G

GRATED PIT

INV.21.86

LAWN

MESH FENCE

CONC. PATH

CO

NC.

PA

TH

GA

RD

EN

METAL FENCE ON TOP OF BRICK RET. WALL

ME

TA

LF

EN

CE

ON

TO

PO

FB

RIC

KR

ET.

WA

LL

METAL FENCE ON TOP OF BRICK RET. WALL

LID

ELECLID

SV

ON

TO

P

OF

FE

NC

EM

ET

AL

W.M.

LID

APPR

OX. L

OC

ATI

ON O

F U

NDER

GR

OU

ND N

BN C

ABLE

BM ON

TOP OF KERB

RL 24.01

1

D.P. 787759

SITE AREA

TREE

5 S

4 H

TREE

6 S

6 H

TREE

6 S

6 H

C

D.P. 330139

ME

TA

L

TIMBER

FENCEMETAL

FENCE PA

LIN

GF

EN

CE

METAL GARAGE

HEAD 27.98

SILL 26.54

HEAD 28.10

SILL 26.51

HEAD27.70

SILL 27.10

No. 33

WEATHERBOARD

DWELLING

TILE ROOF

SMH

TREE

6 S

6 H

TREE

6 S

6 H

CONC. CARPARK

PATIO

18.7

8

18.9

7

19.0319

.03 19

.19

19.2

319.2

9TEL

TEL

ROCK LOG

WALL

CONC DRIVEWAY

BITUMEN CARPARK

BITUMEN

GARDENRAISED

RAISEDGARDEN

BITUMEN CARPARK

BITUMEN CARPARK

BITUMEN CARPARK

19.32

19.33

19.33

19.38

19.40

19.4

3

19.48

19.49

19.53

19.53

19.54

19.57

19.57

19.58

19.58

19.58

19.59

19.59

19.6

3

19.6

4

19.6

8

19.79

19.81

19.84

19.8

6

19.87

19.9

1

OUTLET

19.9

4

19.9

5

19.9

7

20.04

20.05OUTLET

20.12

20.12

20.16

20.16

20.18

20.2

3

20.2

420.2

7

20.2

8

OUTLET

20.33

20.39

20.39

20.41

20.42

20.4

3

20.49

20.50

20.51

20.51

20.51

20.52

20.54

20.56

20.56

20.56

20.58

20.58

20.6

8

20.6

8

20.6

8

20.74

20.77

20.77

20.78

20.78

20.78

20.79

20.79

20.802

0.81

20.84

20.8

4

20.84

20.85

20.85

20.9

0

20.9

2

20.9

6

20.9

6

20.9

7

20.98

21.00

21.00

21.04

21.05

21.08

21.12

21.12

21.1

4

21.14

21.16

21.18

21.24

21.24

21.25

21.27

21.28

21.29

21.30

21.33

21.37

21.38

21.46

21.46

21.54

21.54

21.55

21.5921.61

21.63

21.65

21.66

21.66

21.66

21.67

21.74

21.74

21.76

21.8

1

21.82

21.82

21.85

21.87

21.8

8

21.90

21.91

21.95

21.95

21.99

21.99

22.00

22.01

22.01

22.04

22.07

22.07

22.07

22.08

22.10

22.13

22.14

22.17

22.18

22.18

22.18

22.19

22.2

5

22.2

7

22.30

22.32

22.33

22.34

22.35

22.37

22.37

22.40

22.45

22.45

22.46

22.46

22.49

22.49

22.52

22.53

22.54

22.54

22.54

22.54

22.55

22.58

22.6

3

22.65

22.6

7

22.6

8FL

FL

FL

FL

GUTTER

GUTTER

GUTTER

GU

TT

ER

GU

TT

ER

CO

NC.

CO

NC.

GU

TT

ER

GU

TT

ER

RID

GE

CONC.

CONC.

GA

RD

EN

W

W

W

RID

GE

GU

TT

ER

ME

SH

GA

TE

FE

NC

E

MES

H

GA

TE F

EN

CE

22.69

22.70

22.72

22.73

22.73

22.74

22.76

22.79

22.81

22.84

22.85

22.88

22.9

6

22.97

22.9

7

22.9

7

22.9

7

22.9

8

22.9

9

22.9

9

23.02

23.05

23.06

23.06

23.07

23.11

23.12

23.12

23.14

23.14

23.15

23.15

23.16

23.16

23.1

8

23.2

0

23.2

1

23.22

23.2

4

23.2

6

23.2

7

23.2

9

23.30

23.3

0

23.32

23.33

23.35

23.37

23.39

23.40

23.42

23.44

23.45

23.47

23.47

23.48

23.51

23.53

23.54

23.55

23.56

23.58

23.6

1

23.61

23.6

2

23.6

2

23.67

23.68

23.6

9

23.71

23.71

23.72

23.73

23.73

23.73

23.75

23.76

23.79

23.79

23.79

23.80

23.81

23.83

23.83

23.83

23.83

23.88

23.88

23.9

0

23.9

2

23.9

2

23.9

3

23.9

3

23.9

3

23.9

6

23.9

7

23.9

8

23.9

924.01

24.01

24.01

98°30’30"

45.28

8°2

9’1

0"

40.6

65

278°28’35"

28.325 268°

25’10"

9.2

239°24’10"

4.32

210°1

4’2

5"

12.3

35

188°2

5’2

5"

24.8

55

24.0224.02

24.05

24.05

24.08

24.09

24.11

24.1

4

24.15

24.17

24.18

24.2

3

24.30

24.30

24.33

24.36

24.37

24.50

24.6

0

24.6

0

24.6

224.6

3 24.7

3

24.77

24.82

24.8

2

25.09

26.01

26.41

26.41

26.41

26.41

26.70

26.71

26.74

27.73

27.76

28.24

28.2

5

28.31

28.31

28.69

30.6

1

1778 m†

ST

RE

ET

VEHICLE CROSSING

MA

NN

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

DEMOLITION PLAN

BUILDING TO BE DEMOLISHED

TREE TO BE REMOVED

TREE TO BE REMOVED

TREE TO BE REMOVED

TREE TO BE REMOVED

BUILDING TO BE DEMOLISHED

DA - 005

Page 6: 333 Mann St_Arch_Issue A

SHADOW DIAGRAMS

10am JUNE 21st 12pm JUNE 21stPROPOSED

DA-006

0m

1:1000 @ A1

10m 20m 50m

9am JUNE 21st PROPOSED PROPOSED 11am JUNE 21st

2pm JUNE 21stPROPOSED 3pm JUNE 21st PROPOSED PROPOSED 1pm JUNE 21st

PROPOSED

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

Page 7: 333 Mann St_Arch_Issue A

UNIT 1 UNIT 2 UNIT 3

UNIT 6 UNIT 5 UNIT 4

DA-007

MIN. 3 HOURS OF DIRECT SUN TO

LIVING & OUTDOOR AREAS

MIN. 3 HOURS OF DIRECT SUN TO

LIVING & OUTDOOR AREAS

MIN. 3 HOURS OF DIRECT SUN TO

LIVING & OUTDOOR AREAS

MIN. 3 HOURS OF DIRECT SUN TO

LIVING & OUTDOOR AREAS

MIN. 3 HOURS OF DIRECT SUN TO

LIVING & OUTDOOR AREAS

BALCONY AREA = 13.6 sqm

APARTMENT AREA = 118.5 sqm

BALCONY AREA = 11.2 sqm

APARTMENT AREA = 84.2 sqm

BALCONY AREA = 13.4 sqm ADAPTABLE APARTMENT

APARTMENT AREA = 113.2 sqm

CROSS VENTIALTED APARTMENT

2 BEDROOM APARTMENT 1 BEDROOM APARTMENT 1 BEDROOM APARTMENT

2 BEDROOM APARTMENT3 BEDROOM APARTMENT3 BEDROOM APARTMENT

CROSS VENTIALTED APARTMENT CROSS VENTIALTED APARTMENT CROSS VENTIALTED APARTMENT

SUNLIGHT ACCESS

10am - 1pm JUNE 21

SUNLIGHT ACCESS

12pm - 3pm JUNE 21

SUNLIGHT ACCESS

10am - 1pm JUNE 21

SUNLIGHT ACCESS

10am - 1pm JUNE 21

SUNLIGHT ACCESS

10am - 1pm JUNE 21

APARTMENT AREA = 74.3 sqm

BALCONY AREA = 12.9 sqm

APARTMENT AREA = 53.1 sqm

BALCONY AREA = 8.2 sqm BALCONY AREA = 8.2 sqm

APARTMENT AREA = 53.1 sqm

TYPICAL FLOORAPARTMENT COMPLIANCE DIAGRAMS

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

3000

1700

1500

600

3600

2350

10700

6275

2500 1000

7700

7175

3050

600

700

4950

3050

600

2600

3775 2200 1900 1600

600

5150

3550

2700 4075 2200 900 600 3000 3000

4975 3600

3400

2350

3550

3050

600

2600

3050

600

700

1300

2450

1000

1900 2100 1600 1900 2200 4575

2600

600

3450

650

3500

2525 1075 1000 1975

8100

2350

3600 3075

1575 2025

2250

750

2950

5150

2350

2600

600

3450

650

3500

3075 3600

3900 3800

2925 1075 1000 2500

4000 3600

2400

6450

2350

3000

1700

1500

600

3450

650

10550

8600

6775 6775

14775

1750

750

8100

3000 600 4000 1125

8100

6450

1650

750

3000 3000 4775 3800

750

1000

600

2450

1000

BED 2

BATH

ENSUITE

BED 1

STUDY

KITCHEN

DINING

LIVING

LDYLDY

DINING

KITCHEN

LIVING

BED 1

BATH

LIVING

DINING

KITCHEN

LDY

BED 1

BATH

BED 1

ENSUITE

BATH

LDY

LIVING

DINING

KITCHENBED 2

ST

OR

AG

E

ST

OR

AG

E

ST

OR

AG

E

KITCHEN

BED 2 BED 3

BATH

STUDY

BED 1ENSUITE ROBE

ST

OR

AG

E

LIVING

DINING

ENSUITEROBEBED 1

KITCHEN

DININGLIVING

STORAGE

BED 3

STUDY

BATH

BED 2

LDYLDY

BALCONY

BALCONY

BALCONY

BALCONY

BALCONY

BALCONY

Page 8: 333 Mann St_Arch_Issue A

VIEW 1 VIEW 2 VIEW 3

VIEW 4 VIEW 5 VIEW 6

VIEW ANALYSIS

DA-008

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

Page 9: 333 Mann St_Arch_Issue A

RESIDENTIAL LIFTS

B5 BASEMENT PLAN

RESIDENTIAL PARKING

SERVICES

DEEP SOIL

69

S69

RL 6.00

70

S70S71S72

S73

S74

S75

S76

S77

S78

S79

S80 S81 S82 S83 S84 S85 S86 S87

S88

S89

S90

S91

S92

S93

S94

S95

S96

S97

S98 S99 S100

S101

S102

71

72

73

74

75

76

77

78 79 80 81 82 83 84 85 86 87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

DA - 101

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 10: 333 Mann St_Arch_Issue A

RESIDENTIAL LIFTS

B4 BASEMENT PLAN

RESIDENTIAL PARKING

SERVICES

DEEP SOIL

35

S35

RL 8.70

36

37

38

39

40

41

42

43

44 45 46 47 48 49 50 51 52 53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

S36S37S38

S39

S40

S41

S42

S43

S44

S45

S46 S47 S48 S49 S50 S51 S52 S53

S54

S55

S56

S57

S58

S59

S60

S61

S62

S63

S64 S65 S66

S67

S68

DA - 102

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

GIVE

WAY

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 11: 333 Mann St_Arch_Issue A

RESIDENTIAL LIFTS

B3 BASEMENT PLAN

RESIDENTIAL PARKING

SERVICES

DEEP SOIL

12

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

S1S2S3S4

S5

S6

S7

S8

S9

S10

S11

S12 S13 S14 S15 S16 S17 S18 S19

S20

S21

RL 11.40

S22

S23

S24

S25

S26

S27

S28

S29

S30 S31S32

S33

S34

DA - 103

AU

TO P

AN

EL LIF

T

SE

CU

RIT

Y D

OO

R

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

GIVE

WAY

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 12: 333 Mann St_Arch_Issue A

37

RESIDENTIAL LIFTS

38

39

40

41

B2 BASEMENT PLAN

COMMERCIAL PARKING

SERVICES

SERVICES

BIKES

COMMERCIAL LIFT

COMMERCIAL STAIR

DEEP SOIL

42

43

44

45

46 47 48 49 50 51 52 53 54 55

56

57

5859

60

61

V1

U-TURN BAY

RL 14.10

V2

V3

V4

V5

V6

62

DA - 104

V7

V8

V9

V10

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

GIVE

WAY

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 13: 333 Mann St_Arch_Issue A

1

RESIDENTIAL LIFTS

2

3

4

5

6

7

8

9

10

B1 BASEMENT PLAN

COMMERCIAL PARKING

SERVICES

SERVICES

OSD TANK HATCHED OVER

BIKES

11 12 13 14 15 16 17 18 19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

COMMERCIAL LIFT

COMMERCIAL STAIR

DEEP SOIL

+RL 16.80

DA - 105

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

GIVE

WAY

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 14: 333 Mann St_Arch_Issue A

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

EXIT

RESIDENTIAL LIFTS

DEEP SOIL

LOWER GROUND PLAN

EXIT

500sqm

SERVICES

ENTRY

+RL 21.50

RAMP

RAMP

+RL 20.60

+RL 20.40

+RL 20.40

160sqm

COMMERCIAL LOBBY

COMMERCIAL LIFT

GOODS LIFT

+RL 20.40

MALE

FEMALE

+RL 19.50

+RL 19.50

DA - 106

COMMERCIAL TENANCY A

CURVED CONCRETE STAIR

OSD TANK DOTTED UNDER

+RL 19.50

METAL AWNING DOTTED OVER

GLASS CANOPY DOTED OVER

VOID TO BASEMENT

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

BM ON

TOP OF KERB

RL 24.01

C

D.P. 330139

18.7

8

19.03

19.19

19.2

9

19.33

19.38

19.49

19.6

4

19.6

8

19.81

20.04

20.12

20.12

20.16

20.16

20.2

420.2

7

20.39

20.41

20.42

20.50

20.51

20.51

20.58

20.74

20.85

20.9

0

20.9

2

20.9

7

20.98

21.00

21.04

21.1421.33

21.65

21.66

21.95

22.13

22.45

22.45

22.9

7

23.06

23.33

23.80

23.9

8

24.01

98°30’30"

8°2

9’1

0"

24.1

4

24.17

24.30

24.6

0

27.76

28.69

30.6

1

ETNA STREET

ST

RE

ET

MA

NN

Page 15: 333 Mann St_Arch_Issue A

BM ON

TOP OF KERB

RL 24.01

C

D.P. 330139

18.7

8

19.03

19.19

19.2

9

19.33

19.38

19.49

19.6

4

19.6

8

19.81

20.04

20.12

20.12

20.16

20.16

20.2

420.2

7

20.39

20.41

20.42

20.50

20.51

20.51

20.58

20.74

20.85

20.9

0

20.9

2

20.9

7

20.98

21.00

21.04

21.1421.33

21.65

21.66

21.95

22.13

22.45

22.45

22.9

7

23.06

23.33

23.80

23.9

8

24.01

98°30’30"

8°2

9’1

0"

24.1

4

24.17

24.30

24.6

0

27.76

28.69

30.6

1

ETNA STREET

ST

RE

ET

MA

NN

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

TURNTABLE

COMMERCIAL GARBAGE

RESIDENTIAL LOBBY

BASEMENT RAMP

LOADING DOCK

GROUND LEVEL PLAN

EXIT

VEHICLE ENTRY

+RL 24.00

+RL 24.00

+RL 22.50

SPRINKLER

VALVE

+RL 24.00

SPRINKLER

PUMP

SPRINKLER

BOOST

HYDRANT

BOOST

+RL 24.00

+RL 24.00

RESIDENTIAL GARBAGE

+RL 24.00

FIRE

CONTROL

+RL 23.50

+RL 23.50

+RL 23.50

RESIDENTIAL LIFTS

EXIT

+RL 24.00

+RL 24.00

COMMERCIAL CIRCULATIONGOODS

LIFTS

CAFE

+RL 22.50

+RL 23.00

+RL 24.00

+RL 23.00

MALE FEMALE

DA - 107

DRIVEWAY

+RL 24.00

TH

RO

UG

H SIT

E LIN

K

MAIL B

OXES

ELEVATEDOUTDOOR LANDING

COMMUNAL OPEN SPACE &

DEEP SOIL PLANTING

195sqm

ESCALATORS TO/FROM

LOWER GROUND

ESCALATORS TO/FROM

PODIUM LEVEL 1

LIFT

+RL 23.50

+RL 23.80

COMMERCIAL TENANCY B

350sqm

190sqm

100sqm 60sqm

OUTDOOR SEATING SUBJECT TO FUTURE LICENSING APPROVAL

TIMBER CLADDING & SIGNAGE WALL

METAL ROLLER DOORS

METAL AWNING DOTTED OVER

GLASS CANOPY DOTTED OVER

METAL AWNING BELOW

GLASS CANOPY DOTTED OVER

METAL AWNING DOTTED OVER

1.5m BOUNDARY WALL

OUTDOOR SEATING

REFER TO LANDSCAPE PLAN

DISABLED ACCESS RAMP

REFE

R T

O L

AN

DS

CAP

E P

LA

N

TEXTURED CONCRETE WALL

1.5m BOUNDARY WALL

CURVED CONCRETE STAIR

CURVED CONCRETE STAIR

NEW CONCRETE DRIVEWAY

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

33825

6000

4000

2550

4050

2000

10900

10350

11800

1450

Page 16: 333 Mann St_Arch_Issue A

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

LEVEL 1 PODIUM PLAN

COMMERCIAL LIFT

RESIDENTIAL LIFTS

GOODS LIFT

+RL 28.80

530sqm

420sqm

220sqm

COMMERCIAL CIRCULATION

+RL 28.80

MALE FEMALE

DA - 108

+RL 28.80

OUTDOOR LANDING

+RL 28.80

OUTDOOR LANDING

+RL 28.80

SHOWERS

SHOWERS

COMMERCIAL TENANCY C

COMMERCIAL TENANCY D

ESCALATORS TO/FROM

GROUND

VOID

METAL AWNING

GLASS CANOPY

GLASS CANOPY

METAL AWNING

METAL AWNING

VERTICAL COLOURED GLASS FINS

VERTICAL COLOURED GLASS FINS

GLASS CURTAIN WALL

GLASS CURTAIN WALL

TEXTURED CONCRETE WALL

CURVED CONCRETE STAIR

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

6050

4000

2550

11050

16900

5684 4925 4100 7100 20250

42059

4050

2000

13750

7500

13250

34500

11034 22325 8700 3252

42022

34500

Page 17: 333 Mann St_Arch_Issue A

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

LANDSCAPING+RL 33.60

LANDSCAPING+RL 33.60

UNIT 1

LOBBY

KITCHEN

BATH

LIVING

DINING

BED 1

BED 2

TERRACE

LIVING

DINING

BATH

BED 1

UNIT 2

TERRACE

LDYLDY

UNIT 4

KITCHEN

BATH

LIVING

DINING

BED 1

BED 2

LIVING

DINING

BATH

BED 1

UNIT 3

TERRACE

LDY

LDY

UNIT 6 UNIT 5

BED 2

BATH

LDY

ENSUITE BED 1

KITCHENDINING

LIVING

GARBAGE

TERRACE

KITCHEN KITCHEN

BED 3BED 2

BATH

LDY

ENSUITEBED 1

KITCHEN

DININGLIVING

TERRACE

BED 3

ROBE

+RL 33.60

ROBE

STUDY STUDY

DA - 109

LEVEL 2 PLAN - PODIUM

LANDSCAPING

LANDSCAPING

LANDSCAPING LANDSCAPING

LANDSCAPING LANDSCAPING

TERRACE

4M SETBACK LINE

450MM OVER BOUNDARY LINE

12

M S

ETB

AC

K LIN

E

12M SETBACK LINE

COMMUNAL OPEN SPACE

375sqm

STUDY

SPLAYED BALCONY DOTTED OVER

REFER TO LANDSCAPE PLAN

REFE

R T

O L

AN

DS

CAP

E P

LA

N

OFFSET SPLAYED PLANTER BOXES DOTTED OVER

2m GLASS VISUAL & ACOUSTIC PRIVACY SCREEN

GREEN WALL

2m GLASS VISUAL & ACOUSTIC PRIVACY SCREEN

2m GLASS VISUAL & ACOUSTIC PRIVACY SCREEN

SPLAYED PLANTER BOXES DOTTED OVER

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

6484 21525 1400 7850

4050

2000

3750

2200

3409 29400 12494

1250

27750

1800

3750

6050

12000

9600

11150

3850

3950

Page 18: 333 Mann St_Arch_Issue A

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

UNIT 1

LOBBY

KITCHEN

BATH

LIVING

DINING

BED 1

BED 2

BALCONY

LIVING

BATH

BED 1

UNIT 2

BALCONY

LDY

LDYUNIT 4

KITCHEN

BATH

LIVING

DINING

BED 1

BED 2

BALCONY

LIVING

DINING

BATH

BED 1

UNIT 3

BALCONY

LDY

LDY

UNIT 6

DINING

UNIT 5

BED 2

BATH

LDY

ENSUITEBED 1

KITCHENDINING

LIVING

GARBAGE

BALCONY

KITCHEN KITCHEN

LEVEL 3-18 PLAN - TYPICAL

ENSUITE

ENSUITE

BED 3BED 2

BATH

LDY

ENSUITEBED 1

KITCHEN

DININGLIVING

BALCONY

BED 3

ROBE ROBE

LIFT LIFT

ADAPTABLE

DA - 110

PLANTING PLANTING

PLANTINGPLANTINGPLANTING

FR

ON

T S

ETB

AC

K

450MM OVER BOUNDARY LINE

4M SETBACK LINE

12

M S

ETB

AC

K LIN

E

12M SETBACK LINE

SIDE/REAR SETBACK

SIDE/REAR SETBACK

SID

E/R

EA

R S

ETB

AC

K

SID

E/R

EA

R S

ETB

AC

K

STUDY STUDY

STUDY

SLIDING LOUVRE SCREENS

SLIDING LOUVRE SCREENS

SLIDING LOUVRE SCREENS

SLIDING LOUVRE SCREENS

SLIDING LOUVRE SCREENS

LINE OF BALUSTRADE

FRONT SETBACK

OFFSET SPLAYED PLANTER BOXES. PROFILE FOR ODD NUMBER LEVELS ONLY

OFFSET SPLAYED PLANTER BOXES. PROFILE DOTTED FOR EVEN NUMBER LEVELS ONLY

FRONT SETBACK

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

12102

5207

12000

20750

2700

5199

1000

12000

9850

1600

12000

5215

3009 30200 12094

1450

3790 29400 12102

3000

Page 19: 333 Mann St_Arch_Issue A

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

LEVEL 19 ROOFTOP PLAN

PATH

SPRINKLER TANK

HYDRANT TANK

HYDRANT PUMP

DA - 111

LANDSCAPING

LIFTS

LANDSCAPING

REFER TO LANDSCAPE PLAN

REFER TO LANDSCAPE PLAN

REFE

R T

O L

AN

DS

CAP

E P

LA

N

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

3009 30200 12094

5199

24450

11000

12450

1400

1450

5215

24450

11000

2900

9100

1600

10030

820

3790 29400 12102

Page 20: 333 Mann St_Arch_Issue A

chapman

0m 1m 2m 5m

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

N1:100 @ A1

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D EA B

03

02

04

03

02

04

0101

0505

0606

F

01

1202

02

1202

02

201

01

201

01

201

02

201

01

202

02

202

PEBBLES

PEBBLES

LEVEL 19 ROOF PLAN

DA - 112

ROOFTOP LANDSCAPING

ROOFTOP LANDSCAPING

PODIUM LANDSCAPING

PODIUM LANDSCAPING

GROUND LEVEL LANDSCAPING

GR

OU

ND L

EVE

L L

AN

DS

CAPIN

G

REFER TO LANDSCAPE PLAN

REFER TO LANDSCAPE PLAN

REFER TO LANDSCAPE PLAN

DEEP SOIL PLANTING

195sqm

7500 7500 7500 7500 8950 3244

4350

7950

7500

7500

7050

6200

4350

7950

7500

7500

7050

6200

Page 21: 333 Mann St_Arch_Issue A

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

C D E FA B C D E FA B

COMMERCIAL TENANCY

COMMERCIAL TENANCY

- 1:100

01 SECTION

RAMP

COMMERCIAL TENANCY

SECTIONS

- 1:100

02 SECTION

0m

1:200 @ A1

4m2m 10m

MA

NN

S

TR

EE

T

COMMERCIAL TENANCY

COMMERCIAL TENANCY

COMMERCIAL TENANCY

COMMERCIAL TENANCY

EXIT

RAMP

COMMERCIAL PARKING

COMMERCIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

COMMERCIAL PARKING

COMMERCIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

COMMERCIAL TENANCY

DA -201

RENDERED MASONRY BALCONY UPTURN

RL 20.40

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 24.00

GROUND

RL 91.60

ROOF

RL 88.00

ROOFTOP

LOWER GROUND

B1

RL 16.80

B2

RL 14.10

B3

RL 11.40

B4

RL 8.70

B5

RL 6.00

RL 20.40

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 24.00

GROUND

RL 91.60

ROOF

RL 88.00

ROOFTOP

LOWER GROUND

B1

RL 16.80

B2

RL 14.10

B3

RL 11.40

B4

RL 8.70

B5

RL 6.00

FIXED LOUVRE SCREENS ON SLIDING TRACK

FIXED GLASS BALUSTRADE WITH SS HANDRAIL

FIXED LOUVRE SCREENS ON SLIDING TRACK

RENDERED MASONRY SPANDREL

Page 22: 333 Mann St_Arch_Issue A

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

PLANT, PARKING, STORAGE (NON GFA AREAS)

1 BEDROOM UNIT/STUDIO

2 BEDROOM UNIT

3 BEDROOM

RESIDENTIAL CIRCULATION

RETAIL/COMMERCIAL TENANCY

RETAIL/COMMERCIAL CIRCULATION

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

03 0204 01050603 0204 010506

SECTIONS

- 1:100

02 SECTION

0m

1:200 @ A1

4m2m 10m

COMMERCIAL TENANCY

RAMP

RL 24.00

GROUND

ET

NA

S

TR

EE

T

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

RL 89.80

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

ROOF

RL 20.40

LOWER GROUNDSERVICES

TOILETS

STAIR

B1

RL 16.80

B2

RL 14.10

B3

RL 11.40

B4

RL 8.70

B5

RL 6.00

COMMERCIAL PARKING

COMMERCIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

DA - 202

- 1:100

01 SECTION

COMMERCIAL TENANCY

RL 24.00

GROUND

ET

NA

S

TR

EE

T

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

RL 89.80

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

ROOF

RL 20.40

LOWER GROUND

STAIR

B1

RL 16.80

B2

RL 14.10

B3

RL 11.40

B4

RL 8.70

B5

RL 6.00

COMMERCIAL PARKING

COMMERCIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

RESIDENTIAL PARKING

STAIR COMMERCIAL TENANCY

STAIR

ESCALATORS

OSD

COMMERCIAL TENANCY

CAFE

COMMERCIAL

Page 23: 333 Mann St_Arch_Issue A

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

LO LOUVRE SCREEN OPERABLE

GO GLAZING OPERABLE

GLAZING FIXEDGF

RENDER AND PAINTRP

CN OFF FORM CONCRETE

OFF FORM CONCRETE - TEXTUREDCNT

GB GLASS BALUSTRADE

CT CERAMIC TILE

TIMBER PANELLINGTP

MD METAL ROLLER DOOR

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

IKONCORNER CAFE

CDEF ABC D E FA B

- 1:100

02

0m

1:200 @ A1

4m2m 10m

MA

NN

S

TR

EE

T

- 1:100

01 SOUTH ELEVATION NORTH ELEVATION

MA

NN

S

TR

EE

T

78m HEIGHT LINE

78m HEIGHT LINE

GO

RP

RP

RPGF

GO GO GO GO

GF

RP RP RPRP

RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

RP GO

GF

GOGOGOGORP

RPRP RP RP RP

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

GF

RP

METAL AWNING

VERTICAL COLOURED GLASS FINS

LANDSCAPED PLANTER BOXES

RP

RP

RP

RP

GO GO GO LO GO LO GO LO

RP

GO RENDER & PAINT BLADE WALL

FIXED GLASS BALUSTRADE WITH SS HANDRAIL

RENDERED MASONRY BALCONY UPTURN

LANDSCAPED PLANTER BOXES

RP

RP

RP

LO

GO GOLO GOLO GOLO GO LO

GO

GO GOLO GO LO LO GO LO

GO

GOLO GO LO LO GO LO

GO

GO GO GO GO GO GO

GOLO GO LO GOLO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GO GO LO GO LO GO LO

GO

GO GO LO GOLO LO

GO

GO GOLO GOLO GOLO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GOLO GO LO GO LO GO LO

GO

GO GO GO GO GO

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

GO GO

GO

GO

RP

GO GO GO GO GO GO GO GO

LO

LO

GO GO GO

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CN

CURVED STAIR

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

RL 91.60

ROOF

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 20.40

RL 24.00

GROUND

RL 88.00

LEVEL 19

LOWER GROUND

RL 20.40

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 24.00

GROUND

RL 91.60

ROOF

RL 88.00

ROOFTOP

LOWER GROUND

CT

CT

CT

CT

CT

GF

GF

GLASS CANOPY OVER ENTRY

DA - 301

OFFSET SPLAYED PLANTER BOXES ON ODD LEVELS

OFFSET SPLAYED PLANTER BOXES ON EVEN LEVELS

VERTICAL COLOURED GLASS FINS

GF GF GF GF GF GF

GF

GO

RP

RP MDMD TP

GF GF

GO

NORTH & SOUTH ELEVATIONS

METAL AWNING

EXISTING GROUND LINE

1.5m BOUNDARY WALL

RL 19.50V

RL 23.00V

RL 21.50V

RL 23.00V RL 22.50

V

RL 20.40V

RL 21.50V

RL 23.00V

OUTDOOR SEATING & SOFT LANDSCAPING

TIMBER PANELLING & SIGNAGE WALL

GF

Page 24: 333 Mann St_Arch_Issue A

chapman

DRAWING TITLE:

DRAWING NO.: DATE:

SCALE:

PROJECT:

CLIENT:

17.12.2015A

ISSUE:

NOT FOR CONSTRUCTION

ISSUE DESCRIPTION DATE

A

architecture

17.12.2015

IKON

MANN ST (NSW) Pty Ltd

162 EBLEY ST BONDI JUNCTION

T: 0420 382 700

E: [email protected]

ARCHITECTS:

IN COLLABORATION WITH

LEGEND

LO LOUVRE SCREEN OPERABLE

GO GLAZING OPERABLE

GLAZING FIXEDGF

RENDER AND PAINTRP

CN OFF FORM CONCRETE

OFF FORM CONCRETE - TEXTUREDCNT

GB GLASS BALUSTRADE

CT CERAMIC TILE

TIMBER PANELLINGTP

MD METAL ROLLER DOOR

DRAFT DA SUBMISSION

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT PROJECT

DOCUMENTATION (INCL WRITTEN ARCHITECTURAL SPECIFICATIONS) & ALL

SPECIALIST CONSULTANT DOCUMENTATION INCL STRUCTURAL, MECHANICAL,

ELECTRICAL & HYDRAULIC ENGINEERING DOCUMENTATION ETC.

DO NOT SCALE FROM THIS DRAWING. ONLY FIGURED DIMENSIONS SHALL BE

USED.

REPORT ANY DISCREPANCY BETWEEN THIS DRAWING & OTHER PROJECT

DOCUMENTATION IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION PRIOR TO

COMMENCEMENT OF WORKS ON SITE. ALL STRUCTURAL ELEMENT (LOAD

BEARING COLUMNS, BEAMS, WALLS ETC) SIZES SHOWN ON THESE

ARCHITECTURAL DOCUMENTS ARE INDICATIVE ONLY. REFER ENGINEERS

DOCUMENTS FOR ALL SIZES.

03 0204 0105060302 0401 05 06

333 MANN ST

- 1:100

02

0m

1:200 @ A1

4m2m 10m

ET

NA

S

TR

EE

T

- 1:100

01

ET

NA

S

TR

EE

T

WEST ELEVATION EAST ELEVATION

78m HEIGHT LINE

ELEVATIONS

78m HEIGHT LINE

RL 20.40

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 24.00

GROUND

RL 91.60

ROOF

RL 88.00

ROOFTOP

LOWER GROUND

RL 84.80

RL 81.60

RL 78.40

RL 75.20

RL 72.00

RL 68.80

RL 65.60

RL 62.40

RL 59.20

RL 56.00

RL 52.80

RL 49.60

RL 46.40

RL 43.20

RL 40.00

RL 36.80

RL 33.60

LEVEL 18

LEVEL 17

LEVEL 16

LEVEL 15

LEVEL 14

LEVEL 13

LEVEL 12

LEVEL 11

LEVEL 10

LEVEL 9

LEVEL 8

LEVEL 7

LEVEL 6

LEVEL 5

LEVEL 4

LEVEL 3

LEVEL 2

RL 28.80

LEVEL 1

RL 20.40

RL 24.00

GROUND

RL 91.60

ROOF

RL 88.00

ROOFTOP

LOWER GROUND

FIXED LOUVRE SCREENS ON SLIDING TRACK

RENDERED MASONRY BALCONY UPTURN

FIXED GLASS BALUSTRADE WITH SS HANDRAIL

RP

GO

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

VERTICAL COLOURED GLASS FINS

GLASS CANOPY OVER ENTRY

CN

RP

RP

RP

GF

GF

GO

GF GF GF

GO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

LO

GO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GOGO GO GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO

GO GO LO

GO GO LO

GO GO LO

GO GO LO

GO GO LO

GO GO LO

GO GO LO

GO GOLO

GO GO LO

GO GO LO

GO GO LO

GO GO LO

GO GOLO

GO GO LO

GO GO LO

GO GOLO

GO GO LO

GO

GO

GO

GO

GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

GO GO GO GO

RP RP

CN

GO

CN

CN

RP

CN

RP

RP

CN

RP

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CN

GO

CNT

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RP

RENDERED MASONRY BALUSTRADE

FIXED LOUVRE SCREENS ON SLIDING TRACK

RENDERED MASONRY BALUSTRADE

GO

CN CN

TEXTURED CONCRETE WALL

CURVED STAIR

AWNING

AWNING

AWNING

CNT

CNT

CURVED STAIR

CT CTCNT

CNT

CNT

RL 22.50V

PODIUM

RL 34.80

PODIUM

RL 34.80

DA - 302

RL 22.00V

RL 19.50V

STAIR TO OUTDOOR SEATING & SOFT LANDSCAPING

1.5m BOUNDARY WALL

EXISTING GROUND LINE

RL 24.50V

GF

GOGF GF

GF

GF