3211 Sat 10 th November 2012. Summary. BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards. Swapping of H/V cables on INJ-BPM-01 few times within short time invervals . INJ-BPM-01 signals vs SOL-01 Record AR1 BPM signals to study frequency contents. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/1.jpg)
3211 Sat 10th November 2012
![Page 2: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/2.jpg)
Summary
• BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards.
• Swapping of H/V cables on INJ-BPM-01 few times within short time invervals.
• INJ-BPM-01 signals vs SOL-01• Record AR1 BPM signals to study frequency contents.• INJ-BPM-03 signals simultaneously with INJ-FCUP and PI
laser power trace. • Key finding: The 6 MHz seen in October ‘12 data is not
present now.
![Page 3: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/3.jpg)
BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards.
With the ‘normal’ rack room card (08) this is an example of what the x,y, charge signals look like
Note:-Droop on x and chargespikes on y
![Page 4: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/4.jpg)
BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards• Take fourier of the bunch train signals with initial transient
(6.25 μs) and final droop (25 μs) removed => 70 μs section of the train
whole spectrum including aliasing, no 6 MHz evident
minimum frequency resolvable for 70 μs train is 1/70 μs = 15 kHz
![Page 5: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/5.jpg)
BPM normalisation error studies on INJ-BPM-01 : CARD 06
![Page 6: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/6.jpg)
BPM normalisation error studies on INJ-BPM-01 : CARD 04
![Page 7: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/7.jpg)
BPM normalisation error studies on INJ-BPM-01 : CARD 08
NB mistake here
![Page 8: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/8.jpg)
Conclusions on INJ-BPM-01 vs. BPM attentuation
• The 300 kHz amplitude in the sum_voltage signal seems to depend on the BPM attenuation. Higher attenuation, lower amplitude.
• Behaviour of other low frequency components not very clear.
![Page 9: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/9.jpg)
Swap Cables – X, Y, CHARGE • Switch cables for H pickups to V pickups; and vice versa.
attenuation = 15 attenuation = 18reference
swap cables
swap cables back
![Page 10: 3211 Sat 10 th November 2012](https://reader036.vdocuments.mx/reader036/viewer/2022062501/568161cc550346895dd1b7bf/html5/thumbnails/10.jpg)
Swap Cables – fourier transforms
attenuation = 15 attenuation = 18reference
swap cables