Page 1: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

Workshop

30MeV Proton Cyclotron for neutron source

30MeV Proton Cyclotron for neutron source

Page 2: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

1.Introduction2.Specification of the system3.Layout4.Shedule

1.Introduction2.Specification of the system3.Layout4.Shedule

Neutron source by accelerator

Page 3: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

1.Introduction1.Introduction

Page 4: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

AutoAutoInjectorInjectorCyclotron TargetTarget SynthesizerSynthesizer Auto QCAuto QC

Hot Cell

All-in-One Hot CellSynthesizers / Auto QC / Dispenser

AutoAutoDispenserDispenser

HM-18 HM-10HM-12HM-7

1-1.PET System

Page 5: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

1-2.Historical order of Compact Cyclotron

0

50

100

150

200

250

Total No.

81 83 85 87 89 91 93 95 97 99 01 03 05 07

Year

Trend for orders of Compact Cyclotron at SHI.

HM7HM10

HM12

HM18other

FDG applied to Health insurance in the 2001.

PET market of Japan made rapid progress.

Now?

Page 6: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

1-3.Our Vision of Compact Cyclotron

Diagnosis ⇒ Therapy(Heavy ion,Proton,・・・)

+ αHM-12

Proton Therapy System (1997,NCC KASHIWA) Proton:70-230MeV,max300nA

Page 7: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.Specification of the system2.1 Accelerator system2.2 Irradiation system

2.Specification of the system2.1 Accelerator system2.2 Irradiation system

Page 8: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

Schematics of the system

Proton beam

Neutron beamAccelerator

Irradiation system

Page 9: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1 Accelerator system2.1 Accelerator system

Page 10: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1.1.Specification of the accelerator

Accelerator

Type : AVF Cyclotron

External injection type

Acceleration ion : H-

Extraction ion : H+

Energy : 30MeV

Beam current (Design) : 2mA

Ion source : Multi cusp ion source

Page 11: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1.2.View of Cyclotron

Injection line

Main coil

30MeV Proton Cyclotron

Ion source

Page 12: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1.3.Ion source

Body of the source

TRIUMF type ion source

Page 13: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1.4.Cyclotron

共振器

RF Amplifier

Resonator

Foil stripper

Page 14: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.1.5.Beam transport

Scanner magnets

Bending magnet

CT

QT1

0.900

QT2

-3.000

QT3

3.500

BM

11.357

QC1

3.000

QC2

-3.200

TL1

QL1

TL2

TL3

CL1

CL2

QL1

TL4

TL5

TL6

10

20

30

40

50

10

20

30

40

50

垂直

水平

10

20

30

40

50

10

20

30

40

50

垂直

水平

ビームエンベロープ(mm)

Page 15: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2. Irradiation system2.2. Irradiation system

Page 16: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.1.Specification of irradiation system

Specifications

Fixed port

Production rate of epi-thermal neutronNominal : 2×10 9 neutron/cm2/sec(Maximum : 5×10 9 neutron/cm2/sec)

Irradiation area :250mm×250mmBed : Sitting and Sleeping positionPositioner : Laser markers, CR system

Page 17: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.3. Feature of the target

①Pure Berilium is used for the target→Large production rate and small activation

②Direct cooling by de-ionized water→The target is effectively cooled by spiral cooling routes

③Optimum thickness of the target

→In order to prevent blistering, proton stops in the water layer.

①Pure Berilium is used for the target→Large production rate and small activation

②Direct cooling by de-ionized water→The target is effectively cooled by spiral cooling routes

③Optimum thickness of the target

→In order to prevent blistering, proton stops in the water layer.

Page 18: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.4. Irradiation system (3D view)

Target

Reflector(Leed)

Moderator(Iron)

Moderator(Al)

Moderator(CaF2)

Collimator (LiF+PE)

Base

Page 19: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.5. Collimator

380

380

・Material:LiF+PE・Stacked plates in Aluminum case・Hole shape is made by selection of plates

Page 20: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.7. Irradiation system(Pain view)

Beam duct in not shown

Bed and chairCollimator

Target, Moderator and Reflector

Target case

Pit

Page 21: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.7. View of irradiation (with bed)

Page 22: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

2.2.8. View of irradiation (with chair)

Page 23: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

3.Layout3.Layout

Page 24: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

3.1.Layout (1st Floor)

Page 25: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

3.2.Layout (2nd Floor)

Power supply room

Page 26: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

3.3.Layout (3rd Floor)

Elevator

Patients room

Medical room

Nurse room

Waiting room

Page 27: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

4.Schedule4.Schedule

Page 28: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

4.1.Schedule

3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12

 

 

 

 

 

 (住友重機械)

2007 2008 2009 2010

4.受託研究

(大分類)

1.加速器中性子源

 (住友重機械)

 

3.共同研究

(住友重機械&京都大学)

 

2.治験用設備

製   作据付・調整

前臨床

 治験期間(目標:'09/12/E)

受託研究

       共同研究(照射系の開発+ビーム調整、中性子発生)

予備検討

設計 工事

変更契約

イオン源

磁石組立

磁場測定

全体組立

社内試験

RF 系、電源・制御系

京都大学原子炉実験所殿

Installation & Commissioning

Biological Experiments

Clinical trial

Page 29: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders
Page 30: 30MeV Proton Cyclotron for neutron source...1-2.Historical order of Compact Cyclotron 0 50 100 150 200 250 Total No. 81 83 85 87 89 91 93 95 97 99 01 03 05 07 Year Trend for orders

Today, 3rd March is the Girls’festival (HINAMATSURI) in JAPAN.

You may be back A.S.P, if you have a doughter・・・

Thank you for your attention!