300-54372 solix marketing presentation - boc instruments

42
Introducing FullRange OCT PN 300-54372

Upload: others

Post on 29-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 300-54372 Solix Marketing Presentation - BOC Instruments

Introducing

FullRange™ OCT

PN 300-54372

Page 2: 300-54372 Solix Marketing Presentation - BOC Instruments

• FullRange Field of View

Wide: up to 18mm

Deep: up to 6.25mm

Uncompromised 5µm image quality

• FullRange of Clinical Applications

Retina, Glaucoma, Anterior Chamber, Ocular Surface, Wellness

• FullRange of Cutting Edge Technologies

Ultra-high-speed 120kHz scanning

FullRange retina and anterior chamber scans

3D-PAR 2.0

Multi-volume averaging

3D vessel rendering

Single scan protocol for structural and vascular data

FullRange is the Future of OCT

Page 3: 300-54372 Solix Marketing Presentation - BOC Instruments

• FullRange anterior segment imaging captures entire anterior chamber in a single scan

• External IR imaging enables evaluation of Meibomian glands of the upper and lower lids without a dedicated imaging device

• Proven glaucoma analytics combine structural and vascular images and measurements

• FullRange retinal imaging allows wide and deep imaging of the retina, choroid and vitreous…even in highly myopic patients

• AngioVue® OCT Angiography (OCTA) for non-invasive 3D visualization and quantification of retinal vasculature*

• Fundus and external color photography

• Wellness capabilities or patients suspected of retinal pathologies and glaucoma

Multi-Functional Platform Provides Comprehensive Diagnostic Tools

Page 4: 300-54372 Solix Marketing Presentation - BOC Instruments

Solix TechnologySolix is a new class of OCT based on 27 years of experience in OCT innovation.

Page 5: 300-54372 Solix Marketing Presentation - BOC Instruments

Ultra-High-Speed Scanning Produces Large Field of View and Outstanding Resolution

Images courtesy of Alexandra Miere, MD, Créteil University Hospital, France

Page 6: 300-54372 Solix Marketing Presentation - BOC Instruments

4 Volumes Merged

Single Volume

Multi-Volume Averaging Delivers High-Density Images with Pristine Clarity

Page 7: 300-54372 Solix Marketing Presentation - BOC Instruments

3D PAR 2.0 Improves Artifact Removal in the Deep Plexus

Optovue 3D PAR 2.0Optovue 3D PARNo PAR

Page 8: 300-54372 Solix Marketing Presentation - BOC Instruments

New Segmentation Algorithms Improve RPE and BRM Segmentation…Even in Diseased Eyes

Auto Manual Auto Manual

Auto Manual Auto Manual

Page 9: 300-54372 Solix Marketing Presentation - BOC Instruments

3D Vessel Rendering Enables Real-Life Visualization of Vascular Connectivity

MacTel with Type 3 NV Type 1 CNV

Page 10: 300-54372 Solix Marketing Presentation - BOC Instruments

Anterior Segment

SOLIX FullRange anterior imaging provides stunning views of the entire anterior chamber.

A comprehensive anterior segment package expands the clinical utility of the system to address a broad range of patients.

Page 11: 300-54372 Solix Marketing Presentation - BOC Instruments

• Image the entire anterior chamber with the FullRange scan and use the caliper tools to measure ocular structures.

FullRange Anterior Chamber Scan | 18 x 6.25mm

Image courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 12: 300-54372 Solix Marketing Presentation - BOC Instruments

• Shift the scan depth to evaluate opacities and measure the size of the lens prior to cataract surgery.

FullRange Anterior Chamber Scan | 18 x 6.25mm

Page 13: 300-54372 Solix Marketing Presentation - BOC Instruments

• Quantify epithelial, stromal and total corneal thickness with the 10mm Corneal Layer Map, which features 16 meridians to fully cover the LRS transition zone.

10mm Corneal Layer Map

Dry Eye Total Corneal & Epithelial Thickness

KeratoconusTotal Corneal & Epithelial Thickness

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 14: 300-54372 Solix Marketing Presentation - BOC Instruments

• Use the Highlight Tool to further appreciate subtle changes in thickness. The Change Analysis report measures changes in thickness between visits.

Corneal Layer Map Highlight Tool

Epithelial Thickness Map Epithelial Thickness Map with Highlight Tool

Page 15: 300-54372 Solix Marketing Presentation - BOC Instruments

• Evaluate Meibomian gland structure of the upper and lower lids without a dedicated instrument.

External IR Imaging

Page 16: 300-54372 Solix Marketing Presentation - BOC Instruments

• Document ocular surface conditions without moving the patient to the slit lamp for examination.

External Color Photography

External Color Photograph External Color Photograph with Red Reflex

Page 17: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Dry Eye

10mm Epithelial Thickness Map

Cornea Line Scan External IR Image

• Add new information to the diagnosis and management of dry eye patients.

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 18: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Conjunctival Chalasis

10mm Epithelial Thickness Map

Cornea Line Scan External IR ImageCornea Cube Scan

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 19: 300-54372 Solix Marketing Presentation - BOC Instruments

Glaucoma

The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature.

A single scan protocol generates both OCT and OCTA images with AngioAnalytics® metrics to help you quickly understand each patient’s rate of change.

Page 20: 300-54372 Solix Marketing Presentation - BOC Instruments

Optic Disc Analysis | Disc Combo Report

• Comprehensive GCC and ONH analysis for baseline glaucoma assessments.

Page 21: 300-54372 Solix Marketing Presentation - BOC Instruments

Anterior Segment Analysis | FullRangeAnterior Chamber Scan

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 22: 300-54372 Solix Marketing Presentation - BOC Instruments

• Track change and estimate the rate of change in both GCC and RNFL thickness with unparalleled reproducibility to easily assess how quickly a patient’s disease is progressing.

ONH + GCC Trend Analysis

Page 23: 300-54372 Solix Marketing Presentation - BOC Instruments

AngioDisc Trend Analysis

• Measure the vessel density of the RPCs, assess visit-to-visit change and estimate rate of change in glaucoma patients and suspects. Vessel density analysis complements RNFL and GCC analysis and aids in the management

of advanced glaucoma – especially in cases where neural structural measurements have reached the measurement floor.

Page 24: 300-54372 Solix Marketing Presentation - BOC Instruments

Multi-Visit Reports

Page 25: 300-54372 Solix Marketing Presentation - BOC Instruments

Retina

SOLIX delivers unprecedented views of the vitreous and choroid – even in highly myopic patients.

A single scan protocol generates all necessary images and data for comprehensive retinal analysis to quickly provides the clinical data your practice demands.

Page 26: 300-54372 Solix Marketing Presentation - BOC Instruments

Vitreous Liquefaction and Contraction

• Wide and deep retina scan displays from vitreous to choroid without sacrificing depth resolution…even in highly myopic eyes.

FullRange Retina Scan | 16mm x 6.25mm

Solix: 16mm Wide x 6.25mm Deep

Normal Eye PVD with Traction & ERM

CNV in High Myopia

Images courtesy of Explore Vision Clinic, Paris, France, dil El Maftouhi, Centre Rabelais, Lyon, France and Julie Rodman, NOVA Southeastern University, Ft. Lauderdale, USA

Page 27: 300-54372 Solix Marketing Presentation - BOC Instruments

En Face OCT

6.4 x 6.4mm

9 x 9mm

12 x 12mmMontage of Two 9 x 9mm Scans

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France and Alexandra Miere, MD, Créteil

University Hospital, France

Page 28: 300-54372 Solix Marketing Presentation - BOC Instruments

Retina Line Scans

Line Scan6-12mm Width, 3mm Depth

21 Line Raster Scan6-12mm Width, 2-10mm Height, 3mm Depth

12 Line Radial Scan6-12mm Width, 3mm Depth Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 29: 300-54372 Solix Marketing Presentation - BOC Instruments

• Single scan protocol provides all images and data necessary for comprehensive retinal analysis.

3D Volume Scan

Page 30: 300-54372 Solix Marketing Presentation - BOC Instruments

• Measure retinal thickness and GCC thickness maps and compare to a reference database.

Retinal & GCC Thickness Maps

Page 31: 300-54372 Solix Marketing Presentation - BOC Instruments

• View retinal photos in color, grayscale and inverse modes.

Fundus Photography

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 32: 300-54372 Solix Marketing Presentation - BOC Instruments

AngioVue® OCT Angiography

6.4 x 6.4mm

9 x 9mm

12 x 12mm

Montage of Four 9 x 9mm ScansImages courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France and Alexandra Miere, MD, Créteil

University Hospital, France

Page 33: 300-54372 Solix Marketing Presentation - BOC Instruments

• Real-life visualization of neovascularization

3D OCTA Volume Rendering

MacTel with Type 3 NV Type 1 CNV

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 34: 300-54372 Solix Marketing Presentation - BOC Instruments

AngioAnalytics™ OCTA Metrics

Flow Area Measurements

Non-Flow Area Measurements

FAZMetrics

Retina Vessel Density

Disc Vessel Density

Page 35: 300-54372 Solix Marketing Presentation - BOC Instruments

AngioVue Retina Reports

Page 36: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | MacTel with Type 3 CNV

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 37: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Posterior Vitreous Detachmentwith Epiretinal Membrane

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 38: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Vein Occlusion

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 39: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Diabetic Retinopathy

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 40: 300-54372 Solix Marketing Presentation - BOC Instruments

Case Study | Type 1 CNV

Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France

Page 41: 300-54372 Solix Marketing Presentation - BOC Instruments

WellnessThe SOLIX wellness protocol can reveal the need for more extensive imaging and streamline the exam process by quickly confirming normal or aiding in more efficient diagnosis of pathology.

Page 42: 300-54372 Solix Marketing Presentation - BOC Instruments

Solix Wellness Scan | 12 x 9mm with Fundus Overlay