Force
3-Component Force Link25x25x30 mm up to 2 kN
9317
C_0
03-1
24e-
01.1
4
©2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, SwitzerlandTel. +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.comKistler is a registered trademark of Kistler Holding AG.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 9317C
Fz
Fx
Fy
Miniature force link for measuring the three orthogonal com-ponents of a dynamic or quasistatic force acting in any direc-tion.
• Large measuring range•High rigidity•Very high sensitivity •Calibrated force link• Simple installation•Multipole connector
DescriptionThe force link consists of a piezoelectric 3-component force sensor which is mounted under preload between two mount-ing flanges. This results in a very stiff structure for high natural frequency. Compression and tensile forces can be measured. Ground insulated design for eliminating ground loop prob-lems. The 3-component force sensor has three quartz ele-ments, each is sensitive in X, Y or Z-direction. By applying a force, the quartz elements are creating a charge output. This charge is proportional to the applied force. The charge is trans-ferred to the corresponding pin of the V3 connector (protected design), where the cable can be connected.
The unique manufacturing process and high quality materials results in excellent electrical insulation, allowing also quasi-static measurements.
The force link is supplied calibrated. After correct installation, it is immediately ready for use without re-calibration.
ApplicationThe force links can meas ure the 3 ortho g o nal force com po-nents eas i ly, di rect ly and pre cise ly. Suitable for very low forces, thanks to its very high sensitivity.
Application examples•Crash forces•De ter mi na tion of co ef fi cients of fric tion• Forces at wind tunnel balances•Vibration forces
Technical Data
Range Fx, Fy kN –1,5 ... 1,5
(Without moments if e.g. four
force links are mounted into
one force plate)
Range Fx, Fy kN –0,2 … 0,2
(Example with point of force
application 12 mm above
top plate)
Range Fz kN –3 … 3
(Point of force application
centric)
Overload Fx, Fy, Fz % 10
Calibrated range Fx, Fy kN 0 … 0,5
(Point of force application 0 … 0,05
7,5 mm below top plate surface)
Calibrated range Fz kN 0 … 3
(Point of force application 0 … 0,3
centric)
Max. moments
(Mz = 0; Fz = 0) Mx, My N·m –8/8
(Mx,y = 0, Fz = 0) Mz N·m –6/6
Threshold N <0,01
Axial rigidity N/µm 900
Shear rigidity * N/µm 190
* Without taking bending into account (Force Link installed in ideally stiff base and cover plate)
Page 2/4
3-Component Force Link - 25x25x30 mm up to 2 kN – Type 9317C93
17C
_003
-124
e-12
.14
©2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, SwitzerlandTel. +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.comKistler is a registered trademark of Kistler Holding AG.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Technical Data (Continuation)
Sensitivity Fx, Fy pC/N ≈–26
Fz pC/N ≈–11
Linearity incl. hysteresis %FSO ≤±0,5
each axis
Cross talk Fz → Fx, Fy % ≤±1
(Cross talk Fx, Fy → Fz Fx ↔ Fy % ≤±3
is ≤±3 % if e.g. four force Fx, Fy → Fz % ≤±3
links are mounted in to one
force plate)
Natural frequency fn (x) kHz ≈5
fn (y) kHz ≈5
fn (z) kHz ≈20
Operating temperature range °C –40 … 120
Insulation resistance at 20 °C Ω >1013
Ground insulation Ω >108
Capacitance, each channel pF ≈35
Connector 3-polig, V3-A neg.
M9x0,75
Weight g 85
Fig. 1: Dimensions Typ 9317C
InstallationThe contact surfaces that transfer the forces to the measuring element must be flat, rigid and clean.
If four force links are used for the construction of a measure-ment platform, the following must be observed:•Measuring elements must be ground to the same height• Same material for base and top plate• Base and top plate of sufficient rigidity•Max. temperature 80 °C
The measuring element can be fastened either from outside with four M4 screws each, or from the center with four M3 screws each.
The screws must be tightened sufficiently to ensure that no gap can appear between the contact surfaces, even when the greatest force is applied.
Fig. 2: Mounting example: Force measurement on vibrating tables
Page 3/4
3-Component Force Link - 25x25x30 mm up to 2 kN – Type 9317C93
17C
_003
-124
e-12
.14
©2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, SwitzerlandTel. +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.comKistler is a registered trademark of Kistler Holding AG.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Measuring System with 3-Component Quartz Force Link
3-Component Degree of protection Connecting cable1) Multichannel Meas. quartz force link EN60529 charge amplifier2) value
with V3 neg. connector
Type 1698AA…
V3 pos. 3 x BNC pos.
Fx
Fy
Fz
Type 1698AB…
V3 pos. Fischer 9 pole pos
IP65
IP67
Cable welded to sensor
V3 neg.
1) see Cables for multicomponent force sensors, dynamometer and measuring platforms data sheet 1687B_000-5452) see Multichannel charge amplifier for multicomponent force measurement data sheet 5070A_000-485
Type 9317C
Type 1698ACsp
V3 pos. Fischer 9 pole pos.
Type 5070Ax00xx
Type 5070Ax01xx
Measuring System with four 3-Component Quartz Force Links (Dynamometer)
Fx
Fy
Fz
IP65
Type 1698AB…
4 pieces
Type 5417
IP65
148x62x35 mm
4 x Fischer Fischer Flange 9 pole neg. 9 pole neg.
3-Component quartz Degr. of prot. Connecting cable1) Summing box Conn. cable1) Multichannel Meas. force link with EN60529 charge amplifier2) value
V3 neg. connector
V3 pos. Fischer 9 pole pos.
pos. pos.
Type 1687B…
3-core
Type 5070Ax01xxType 9317C
4 pieces
Fx12
Fx34
Fy14
Fy23
Fz1
Fz2
Fz3
Fz4
IP67
Cable welded to
sensor
Type 1698ACsp
4 pieces
V3 pos. Fischer 9 pole pos.
pos. pos.
Type 1677A…
8-core
Type 5070Ax11xx
Type 5070Ax21xxFx
Fy
Fz
Mx
My
Mz
4 x V3 neg.
Page 4/4
3-Component Force Link - 25x25x30 mm up to 2 kN – Type 9317C93
17C
_003
-124
e-12
.14
©2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, SwitzerlandTel. +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.comKistler is a registered trademark of Kistler Holding AG.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Measuring Signal ProcessingFor the measuring system a charge amplifier is needed. This converts the measuring signal (charge) into a voltage. The value that is output is exactly proportional to the force.Type 5070A... multichannel charge amplifier was built specifi-cally for the multicomponent force measuring system.
Fig. 4: Multichannel charge amplifier Type 5070A…
Included Accessories•None
Optional Accessories Type•Connecting cable, 3-core 1698AA…•Connecting cable, 3-core 1698AB…•Connecting cable, 3-core 1698ACsp• Summing box 5417
Ordering Key Type• 3-Component quartz force link 9317C
25x25x30 mm, –3 … 3 kN
Force ApplicationIf a single quartz force link is used, the resulting force vector should pass through the center of the sensor where possible. Eccentric force application creates a moment loading on the sensor. This is only permissible up to the specified values. The maximum force ranges must be reduced correspondingly.A dynamometer of sufficiently rigid structure with four quartz force links prevents too great moment loading on the single sensor element.
ParallelingWhen building a dynamometer, the four quartz force links are mechanically paralleled. The measuring signals (electric char-ge) of the four sensors can also be paralleled (summated). The summated signal corresponds to the algebraic total of the individual forces.Type 5417 summing box facilitates the simple and reliable interconnection of measuring signals.
Fig. 3: Summing box Type 5417
There is also Type 5080A... charge amplifier. This provides an extended measuring range and a higher degree of accuracy, particularly when measuring low forces.