2/4 weru afino tec md - passive house · phe phd phc phb pha. ... the window u-values were...
TRANSCRIPT
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 1092wi04 valid until 31st December 2018
www.passivehouse.com
Category: Window FrameManufacturer: WERU Group Spain,
Cabanas de Ebro (Zaragoza),Spain
Product name: WERU AFINO TEC MD
This certificate was awarded based on the followingcriteria for the warm, temperate climate zone
Comfort UW = 1.00 ≤ 1.00 W/(m2 K)UW ,installed ≤ 1.05 W/(m2 K)with Ug = 0.90 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.65
CERTIFIEDCOMPONENTPassive House Institute
warm, temperate climate
phBPassive House
efficiency class phE phD phC phB phA
WERU Group SpainBarrio Estacion, Nave 2, 50638 Cabanas de Ebro (Zaragoza), SpainT +34 628 01 04 05 |B [email protected] | Í http://www.weru.es |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
PVC-frame with reinforcement inside the blind-frame. Pane thickness: 48 mm (4/18/4/18/4), rebatedepth: 19 mm, spacer: TGI-Spacer P
Explanation
The window U-values were calculated for the test window size of 1.23 m× 1.48 m with Ug = 0.90 W/(m2 K).If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.90 0.74 0.70 0.64 W/(m2 K)↓ ↓ ↓ ↓
Window UW = 1.00 0.89 0.86 0.82 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.
The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/4 WERU AFINO TEC MD
www.passivehouse.com
Frame width U-value frame Ψ -panel edge Temp. Factorbf Uf Ψg fRsi=0.25
Framevalues mm W/(m2 K) W/(m K) [-]
Top (to) 115 1.04 0.021 0.69
Side (s) 115 1.04 0.021 0.69
Bottom (bo) 115 1.04 0.021 0.69
Mullion1 casement
(m1) 118 1.02 0.021 0.71
Spacer: TGI-Spacer Precision Secondary seal: Polyurethane
Validated installations
Timber frame
UWall = 0.17 W/(m2 K)
Ψinstall W/(m K)Top 0.014Side 0.014Bottom 0.026
UW ,installed = 1.05 W/(m2 K)
EIFS
UWall = 0.23 W/(m2 K)
Ψinstall W/(m K)Top 0.000Side 0.000Bottom 0.013
UW ,installed = 1.00 W/(m2 K)
Cavity wall
UWall = 0.21 W/(m2 K)
Ψinstall W/(m K)Top 0.003Side 0.003Bottom 0.014
UW ,installed = 1.01 W/(m2 K)
3/4Component-ID: 1092wi04
www.passivehouse.com