22sv06f075t riego jpii -2
TRANSCRIPT
-
7/21/2019 22sv06f075t Riego Jpii -2
1/3
Fluid
pH-value at t A
Operating temperature t A
Density at t A
Vapor pressure at t A
Kin. viscosity at t A
Nominal flow
Nominal head
Static head
Inlet pressure
Altit udeAv ailable sy stem NPSH
C
bar
kg/dm
mm/s
l/s
m
m
bar
mm
Water
7,2
57
0
7
0
Solids
4
1
0
0,098 0,0234
1000
1,569
Env ironmental temperature 20
C
22SV06F075T
1 0No. of pumps Reserv e //
Single head pumpPumpe ty pe
Operating data
Impeller R
Max.
designed
Min.
Speed
Max. working pressure
Nominal
Max-
Min-
Flow
Number of st ages
Nominal
at Qmax
at Qmin
Head
Head H(Q=0)
NPSH 3%
Shaf t power
Max. shaft power
Eff iciency
bar
mm
mm
mm
l/s
l/s
l/s
m
m
m
kW
kW
%
m
m
2900
9,2
Make
Max. casing pressure bar
108
108
108
8,1
42,3
93,293
3,6
6,4
63,23
6
7,2
56,4
7,2( )
6,3
Pump data
1/min
6,3( )Weight
MaterialsPump Shaft Seal
Q1-Silicon carbide
Fixed Assembly
Elastomers
Springs
Other Components
Rotating Assembly
B-Resin impregnated carbon
E - EPDM
G-AISI 316
G-AISI 316
Single seal
SV - Uniten
Stainless steel / AISI 304
Stainless steel / AISI 304
Stainless steel / AISI 304
Stainless steel / AISI 304
Stainless steel / AISI 304
Cast iron
Aluminium
Aluminium
Stainless steel / AISI 304
EPDM
Stainless steel / AISI 304
Tungsten carbide
Stainless steel / AISI 304
Stainless steel
Technopoly mer PPS
Pump body
impeller
Diffuser
Outer sleev e
Shaft
Adapter
Base
Coupling
Seal plate
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring
Motor data
Manuf acturer
Specif ic design
Rated power
SpeedElectric v oltage
Electric current
Degree of protection
Frame size
Lowara
Ty pe PLM132.../375 E3
3 phase IE3 motors (premium ef f iciency )
7,5 kW
400 V F
IP 55
2935 1/min
14,1 A
132
kg 84
Remarks:
Project no.
Project
Customer
Contact
Phone number
Email
2015-03-11Date
+34-28022 Madrid
913297899
XYLEM WATER SOLUTIONS
1016LD661
Page 1 / 3
Insulation class
RAL 5010
Roten
TechnicalData
Colour
Lowara
-
7/21/2019 22sv06f075t Riego Jpii -2
2/3
22SV06F075T
Project no.
Project
Customer
Contact
Phone number
Email
2015-03-11Date
Head
Efficiency
NPSH-values
Shaft power P2
22SV06
69,7% Eff.
Application range
56,4 m
63,2 %
3,61 m
6,3 kW
7,16 l/s
22SV06
56,4 m
63,2 %
3,61 m
6,3 kW
7,16 l/s
22SV06
56,4 m
63,2 %
3,61 m
6,3 kW
7,16 l/s
22SV06 (P2)
56,4 m
63,2 %
3,61 m
6,3 kW
7,16 l/s
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
76
80
84
88
92
96
100
104
[m]
0
10
20
30
40
50
60
[%]
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
[m]
4,0
4,4
4,8
5,2
5,6
6,0
[kW]
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0 7,5 8,0 8,5 [l/s]
1
Power datas referced to:
Water [100%] ; 4C; 1kg/dm; 1,57mm/s
Operating Data Specification
Flow
Head
Hydraulic data (duty point)
Flow
Head57 m
7,2 l/s 7,16 l/s
56,4 m
Impeller R
Frequency
Speed
Impeller design
50
2900 1/min
108 mm
0 mStatic head
Performanc e according to ISO 9906 - Annex A
Hz
1016LD661
+34-28022 Madrid
913297899
XYLEM WATER SOLUTIONS
TenderHydrau
lic
Hydraulic data
MEI >= 0,7
-
7/21/2019 22sv06f075t Riego Jpii -2
3/3
Dimensions
Weight
kg
D1 256D2 350L1 734L2 428M 191
mm
84
22SV06F075T
Project no.
Project
Customer
Contact
Phone number
Email
2015-03-11Date
1016LD661
+34-28022 Madrid
913297899
XYLEM WATER SOLUTIONS
DimensionalData
Drawing