220 EXPRESS CASH DISPENSER
(5) OR (6) DENOMINATION IN A UL SAFE
FRONT LOAD
PLAN VIEW
PERSPECTIVE
FRONT VIEW
CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR
ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING
AND SITE PREPARATION GUIDE, TP-821268-001
SIDE VIEW
SH
OW
N
572
")4
3(61
72
")2
1(1’-10
744
")4
1(2’-5
440
")165
(1’-5
1079
")2
1(3’-6
52
")1611
(6
170
(2")
51
")87
(1’-2
377
")161
(2
650
")1611
(3
94
")169
(2’-1
572
")43
(6
172
")21
(1’-10
744
")41
(2’-5
1079
")2
1(3’-6
89
")4
3(4
121
")4
1(2’-10
871
")2
1(3
")8
7 (22
440
")165
(1’-5
LEVELING LEGS
KEY LOCK DOOR
OPTIONAL MANUAL
DROP SLOT STORAGE BINS
CASH PRESENTER
LIGHTS "GREEN OR RED"OPERATOR DISPLAY
0mm (WITHOUT LEVELING
LEGS) TO 22mm (78") MAXIMUM
ADJUSTMENT 0mm TO 22mm (78")
LIGHTS "GREEN OR RED"
898
(2’-1138")
POWER CORD LENGTH
2438mm (8’-0")
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
( DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S )
"ALL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E."
PA
GE 2 O
F 4
FIL
E N
O. 177-5
32 R
EV. 3
SPECIFICATIONS
POWER OF ELECTRICAL RUN
2-5 KVA
MACHINE STATUS
IDLE (NO TRANSACTION)
TRANACTION (DISPENSE IN PROGRESS)
70 WATTS
190 WATTS
OPERATING ENVIRONMENT:
FINISH:
WEIGHT:
PHYSICAL SECURITY:
ALARM PROTECTION:
POWER REQUIREMENTS:
COMMUNICATIONS CABLING:
SIGNAL CABLE RUN CONSTRAINTS:
SIGNAL CABLE INSTALLATION CONSTRANTS:
POWER USAGE (@ 120V)
REAR VIEW SIDE VIEW
104-122 VAC 60Hz (+/-1%) SINGLE-PHASE
207-214 VAC 50Hz (+/-1%) SINGLE-PHASE
POWER TO THE CASH DISPENSER MUST BE PROTECTED BY A
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE
(SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE
PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER)
MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
104-122 VAC 60Hz SERVICE, DISCONNECT AT 20 AMPERES
207-214 VAC 50Hz SERVICE, DISCONNECT AT 10 APRERES
TEMPERATURE 10°C TO 40°C (50°F TO 104°F) MAXIMUM
TEMPERATURE CHANGE RATE:
� 8°C (18°F) IN 60 MINUTES.
RELATIVE HUMDITY 20 TO 80% NON-CONDENSING MAXIMUM
RELATIVE HUMDITY CHANGE RATE:
10% IN 60 MINUTES.
SAFE
INTERFACE BEZEL
TEXTURED ASPEN WHITE
TEXTURED MINERAL GRAY
386kg (850 LBS.)
THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR
PACKAGE. THE BASIC PACKAGE INCLUDES A SAFE DOOR OPEN
SWITCH, ALARM SHUNTING SWITCH, AND RATE-OF-RISE HEAT SENSOR.
SERIAL 6 METRES (20’-0")
15 METRES (50’-0")
SERIAL
USB 5 METRES (16’-0")
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS
OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND
ELECTRICAL EQUIPMENT CABLE RUN.
BELOW
2 KVA
127mm
(5")
ABOVE
5 KVA
127mm
(5")
TYPE OF ELECTRICAL RUN
FLUORESCENT, NEON OR INCANDESCENT
LIGHTING FIXTURES127mm
(5")
UNSHIELDED POWER LINE OR
ELECTRICAL EQUIPMENT
127mm
(5")
305mm
(1’-0")
610mm
(2’-0")
UNSHIELDED POWER LINES OR
ELECTRICAL EQUIPMENT WITH
SIGNAL CABLES ENCLOSED IN
GROUNDED CONDUIT
305mm
(1’-0")
152mm
(6")
76mm
(3")152mm
(6")
POWER LINES IN GROUNDED
CONDUIT WITH SIGNAL CABLES
IN GROUNDED CONDUIT
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN
CONDUITS. UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE
SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND
AS MUCH STRAIN IN INSTALLATION.
THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE WIRE
UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE
MUST INCLUDE A THRID-WIRE EARTH GROUND (CONDUIT GROUND
NOT ACCEPTABLE). THE CASH RECYCLER WILL PROVIDE A POWER
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED
MUST BE AS SPECIFIED BELOW.
APPEARANCE DOOR TEXTURED GRANITE GRAY
400
")169
(1
40
")43
(1’-3
440
")165
(1’-5
89
")4
3(4
121
")4
1(2’-10
871
")2
1(3
650
")1611
(3
94
")169
(2’-1
960
")4
3(4
121
")16
13
(3’-1
1081
")16
9(3’-6
744
")41
(2’-5
572
")43
(6
172
")21
(1’-10
1079
")2
1(3’-6
64mm
(2 12")
30mm
(1 316")
THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295.
12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE
DOOR HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS
CONTROLLED BY A GROUP 2 COMBINATION LOCK WITH KEYLOCKING
DIAL CAPABILITY OR OPTIONAL ELECTRONIC LOCK.
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N"A
LL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E."
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
( DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S )
R
CALL 1-800-999-3600
PA
GE 3 O
F 4
FIL
E N
O. 177-5
32 R
EV. 3
PLAN/SECTION VIEW
PLAN VIEW SERVICE AREA
220 EXPRESS CASH DISPENSER
5 OR 6 DENOMINATION IN A UL SAFE
(FRONT LOAD)
FOR ADDED SECURITY:
ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS:
ANCHORING THE CASH DISPENSER TO WOOD FLOORING:
ANCHORING THE CASH DISPENSER TO STEEL FLOORS:
NOTES:
MINIMUM SERVICE AREA
RECOMMENDED SERVICE AREA
ALL ELECTRICAL AND DATA
CABLES MUST ENTER UNIT IN
THIS AREA
12 2 1
2
2
1 1
MINIMUM
RECOMMENDED
MINIM
UM
RE
CO
MM
EN
DE
D
1202
")165
(3’-11
1507
")165
(4’-11
648
")2
1(2’-1 6
00
")8
5(1’-11
(1’-4")
406
")165
(1’-5
440
(1’-2")
356
(1’-10")
558
")165
(1’-5
440
(1’-8")
508(3’-1")
940
(3’-7")
1092
(3")
76
")2
1(1’-318
(4")
102
(3")
76
")83
(2
60
")1613
(9
250
")43
(3
95")8
3(1
35
650
")16
9(2’-1
")8
1(3
80
")16
11
(1’-7500
")4
3(2
70
")16
11
(6
170
(2")
51
(1’-5")
431
140
")16
5(4
110
")4
3(1’-3
400
")2
1(5
20
")1613(
20
")43
(1’-3
400
")1613(
440
")165
(1’-5
ALLOW 25mm (1") MINIMUM
VENTILATION CLEARANCE
CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODED BEAMS
CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT
THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING
CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED
REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL
STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (14") THICK. IT IS IMPORTANT TO
NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT
OF CONCRETE FLOORS.
CASH DISPENSERS INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED
METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS
OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO
A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO
PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST
BE AT LEAST 13mm (12").
IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS
WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (34") ANCHOR BOLT THAT
IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm
(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.
ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS
EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS
ANCHORED.
IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH
ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD
FOR YOUR INSTALLATION.
(4")
102
(3")
76
THIR
D
AN
GL
E
PR
OJ
EC
TIO
N"A
LL DIM
EN
SIO
NS A
ND D
ESIG
N C
RIT
ERIA
SU
BJE
CT T
O C
HA
NG
E W
ITH
OU
T N
OTIC
E."
DIM
EN
SIO
NS I
N M
ILLIM
ET
RE
S
( DIM
EN
SIO
NS I
N F
EE
T-I
NC
HE
S )
PA
GE 4 O
F 4
FIL
E N
O. 177-5
32 R
EV. 3
PLAN VIEW
ELEVATION
PLAN VIEW
ELEVATION
PERSPECTIVE
SIDE/SECTION
PERSPECTIVE
SIDE/SECTION
EXPRESS CASH DISPENSER - MCS 3000 APPLICATION
EXPRESS CASH DISPENSER - DRIVE-UP APPLICATION
1344
")1613
(4’-4
1341
")165
(1’-5
440
")1611
(8’-9
2684
")165
(1’-5
440
")87
(4’-4
")4
3(6
171")
43
(6
171
475
")1611
(1’-6
475
")83
(2’-9
847
")165
(1’-5
440
")167
(2’-9
850
")1611
(1’-6
475
")43(
19
")43(
19")16
11(1’-6
475
")165
(2’-9
847
")165
(1’-5
440
")167
(2’-9
850
")1611
(1’-6
")43(
19
")43(
19")2
1(20’-4
6210
")43(
19
")43(
19
27
(1")
25
")1611
(1’-6
475
")85
(1’-10
575
")165
(1’-5
440
")85
(2’-4
727
")1611
(1’-6
475
")161
(1
(9’-0")
2743
(2’-2")
660
475
")1611
(1’-6
475
")85
(1’-10
575
")165
(1’-5
440
")85
(2’-4
727
")1611
(1’-6
2691
")1615
(8’-9
")2
1(1’-2
368")
43
(6
171